References
- S. S. Kang, J. H. Kim, H. W. Lee, C. W. Mun, and S.H. Nam, 'X-ray response characteristic of Zn in the polycrystalline Cdl_xZnxTe detector for digital radiography', Transactions on Electrical and Electronic Materials, Vol. 3, No 2, p. 28, 2002 https://doi.org/10.4313/TEEM.2002.3.2.028
- J. A. Rowlands and D. M. Hunter, 'X-ray imaging using amorphous selenium: Photoinduced discharge (PID) readout methods for digital general radio-graphy', J. Med. Phys., Vol. 18, p. 1983, 1995
- H. J. Lee, K. T. Lee, S. G. Park, U. S. Park, and H. J. Kim, 'Electrical and leakage current characteristic of high temperature polycrystalline silicon thin film transistor', Transactions on Electrical and Elec-tronic Materials, Vol. 11, No. 10, p. 918, 1998
- J. D. Valentine, D. K. Wehe, G. F. Knoll, and C. E. Moss, 'Temperature dependence of CsI(Tl) ab-solute scintillation yield', IEEE Trans. Nuci. Sci., Vol. 40, No.4, p. 1267, 1993
- J. K. Park, S. S. Kang, J. H. Kim, C. W. Mun, and S.H. Nam, 'Zinc sulfide-selenium X-ray detector for digital radiography', Transactions on Electrical and Electronic Materials, Vol. 3, No.4, p. 16,2002 https://doi.org/10.4313/TEEM.2002.3.2.016
- Fiorini. C, Longoni. A, Perotti. F, and Labanti. C, 'Detectors for high resolution gamma-ray imaging based on a single CsI(Tl) scintillator coupled to an array of silicon drift detectors', J. of IEEE, Vol. 1, No.1, p. 10,2001
- I. Fujieda, G. Cho, J. Drewery, T. Jing, S. N. Kaplan, S. Qureshi, and D. Wildermuth, "Amorphous sili-con based detector', J. Non-crystalline Solid, Vo1.l37, No. 12, p. 1291, 1991 https://doi.org/10.1016/S0022-3093(05)80360-6
- M. Kobayashi and S. Sakuragi, 'Radiation damage of CsI(Tl) crystals above 103 rad', Nucl. instr. and Meth., Vol. A254, p. 275, 1987
- S. O. Kasap and J. A. Rowlands, 'photoconductor selection for digital flat panel x-ray imaging detectors based on the dark current", J. Vac. Sci. Technol., Vol, 18, No, 2, p. 615, 2000 https://doi.org/10.1116/1.582237
- Wei Zhao and J. A. Rowlands, 'X-ray imaging using amorphous selenium: Feasibility of a flat panel self-scanned detector for digital radiology', J. Med. Phys., Vol. 22, p. 1595, 1995 https://doi.org/10.1118/1.597628
- C. Haugen, S. O. Kasap, and J. Rowlands, 'charge transport and electron-hole pair creation energy in stabilized a-Se x-ray photoconductors', J. Phys. D: Appl. Phys., Vol. 32, p. 200, 1999 https://doi.org/10.1088/0022-3727/32/3/004
- Robert E. Johanson, S. O. Kasap, J. Rowlands, and B. Polischuk. 'Metallic electrical contacts to stabilized amorphous selenium for use in X-ray image detectors', J. Non-Crysta. Solids, Vol. 227-230; p.1539,1998
Cited by
- A Study on the Physical Characteristics of Photoconductors for Photon Counting based X-ray Sensor Application vol.8, pp.7, 2014, https://doi.org/10.7742/jksr.2014.8.7.423
- The Fabrication and Property Evaluation of Poly-crystalline CdTe based Photon Counting X-ray Sensor vol.9, pp.7, 2015, https://doi.org/10.7742/jksr.2015.9.7.439
- Design and Fabrication of HgI2 Sensor for Phosphor Screen based flat panel X-ray Detector vol.51, pp.12, 2014, https://doi.org/10.5573/ieie.2014.51.12.189