축사 규모별 누전성분 특성 분석 (Analysis of Characteristic for Electric Leakage Component at Stable Size)

  • 김성철;김두현
    • 한국안전학회지
    • /
    • 제27권6호
    • /
    • pp.54-58
    • /
    • 2012
  • This paper is purposed to analyze electric leakage component which can prevent electrical fires on breaker capacity expansion and power failure by operation of ELB(Earth leakage breaker) for stable sizes. In order to analysis for electric leakage component for stable sizes, this paper studied field state investigation which are at stable companies( 10 companies) in cheong-won location to deduce the problems of electric leakage component is analyzed. The field state experiment method is measured with electric leakage component which load part of ELB detected by electric loads(electrical fan, lighting, auto waterer, feeder and halogen lighting) and stable sizes. Results show that electric leakage component suggested in this paper are valuable and usable to electrical fire in leakage current based on environment factor, which will prevent severe damage to human beings and properties and reduce the electrical fires in stable.

우사(牛舍)에서 전기배선의 종류와 길이에 따른 저항성 및 용량성 누전전류 분석 (Analysis of Resistive and Capacitive Leakage Current according to Wiring Type and Length at Cattle Barn)

  • 유상옥;김두현;김성철
    • 한국안전학회지
    • /
    • 제29권6호
    • /
    • pp.34-39
    • /
    • 2014
  • This paper is aimed to prevent danger of electrical fire at cattle barn to detect resistive and capacitive leakage current component for wiring type and length. In order to analysis for electric leakage component for cattle barn sizes and normal buildings, this paper was studied field state investigation which are at cattle barn companies(10 companies) in Cheong-won location and normal buildings at Nam-bu market in Jeon-ju location. Market to deduce the problems of electric leakage component is analyzed. The resistive and capacitive leakage current component for wiring type and length is analyzed at Beon-young cattle barn. Results show that electric leakage component suggested in this paper are valuable and usable to electrical fire in leakage current based on environment factor, which will prevent severe damage to human beings and properties and reduce the electrical fires in cattle barn. It is acceptable for electrical equipment use in an cattle barn.

새로운 저항성 누전전류 측정 방법 (A New Method for Resistive Leakage Current Measurement)

  • 함승진;한송엽;고창섭
    • 전기학회논문지
    • /
    • 제56권8호
    • /
    • pp.1397-1404
    • /
    • 2007
  • It is important to measure the resistive component separately from the total leakage current at power distribution line. It is because electric disasters such as electric shock and fire are caused mainly by the resistive component of the total leakage current. In this paper, a new theory for measuring the resistive component separately from the total leakage current is suggested, and is embodied to an actual circuit using operational amplifiers, analog switch and R-C low pass filter. Through experiments for various cases containing both the resistive and capacitive leakage currents, the suggested algorithm is confirmed to be able to measure the resistive leakage current within 4.1% of error even when the capacitive leakage current is much bigger than the resistive one. The suggested method is expected to lower the total cost because it can be realized using simple and cheap devices, and implies the measuring time can be possibly reduced because the resistive leakage current is computed exactly from the signals during only a half period of power voltage.

실리콘 산화막의 저레벨 누설전류에 관한 연구 (A Study on the Low Level Leakage Currents of Silicon Oxides)

  • 강창수;김동진
    • 전자공학회논문지T
    • /
    • 제35T권1호
    • /
    • pp.29-32
    • /
    • 1998
  • 실리콘 산화막에서 저레벨 누설전류를 조사하였다. 저레벨 누설전류는 전이요소와 직류요소로 구성되어 있다. 전이요소는 스트레스에 의해 두 계면트랩 가까이 발생된 트랩의 충방전에 의한 터널링으로 나타났으며 직류요소는 산화막을 통한 트랩 어시스트 터널링으로 나타났다 그리고 저레벨 누설전류는 산화막에서 발생된 트랩의 수에 비례하였다. 저레벨 누설전류는 트랩의 충방전 누설전류이며 비휘발성 소자의 데이터 유지능력에 영향을 주었다.

  • PDF

저항성 누전전류에 의하여 동작하는 새로운 누전차단기 (The New Residual Current Protective Devices Operating by Resistive Leakage Current)

  • 함승진;한송엽;고창섭
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.198-207
    • /
    • 2008
  • The conventional Residual Current Protective Devices(RCD, or earth leakage circuit breaker, ELB) operates depending on the total leakage current which is the vector-sum of resistive and capacitive components of a leakage current. However, the electric disaster such as electric shock or fire is mainly caused by the resistive component. Therefore, in this view point, the RCD is more realistic when it operates by the resistive component of the leakage current. In this paper, a new algorithm for measuring the resistive leakage current from the total leakage current is suggested, and is realized to an actual circuit. According to the suggested algorithm, the resistive component of the leakage current can be found by integrating the total leakage current over only a half cycle of the line voltage, and it is realized by using analog switches and resettable integrators. It is confirmed through experiments that the suggested algorithm detects, within maximum average error of 6.74%, the resistive leakage current from the total leakage current, and the RCD employing the suggested algorithm brakes the circuit within the regular interrupt time(30msec).

열화정도에 따른 배전용 피뢰기의 열화특성 분석 (Analysis of degradation of distribution lightning arresters as degradation degree)

  • 장동욱;박동배;박영국;이용희;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.140-143
    • /
    • 2000
  • The primary function of ZnO lightning arrester is to protect transmission and distribution equipment from overvoltages and to absorb electrical energy resulting from lightning or switching surges and form temporary overvoltage. However, ZnO lightning arrester are known to exhibit an increases in resistive current with time, the rate of increase being exacerbated with increasing applied voltage and ambient temperature. So, it is important to the leakage current measurement of ZnO lightning arrester. In addition, since the resistive leakage current caused by deterioration of ZnO lightning arrester mainly caused an increase of the third harmonic component, thereby it is possible the arrester degradation diagnosis by measuring the third harmonic component in the total leakage current. The leakage current and third harmonic component are measured and used to investigate the degradation diagnosis of ZnO element of arrester. Also the SEM photography is used to investigate the change of crystal structure of ZnO element with degradation.

  • PDF

Electrical Characteristic Changes of ZnO Varistors by Energy Absorption

  • Kim, Woo-Hyun;Hwang, Seong-Cheol;Wang, Guoming;Kil, Gyung-Suk;Ahn, Chang-Hwan
    • 한국전기전자재료학회논문지
    • /
    • 제30권12호
    • /
    • pp.817-821
    • /
    • 2017
  • As a ZnO varistor is subjected to electrical and environmental stresses, it degrades gradually, which may result in power interruption by short circuit. This study investigates changes in the electrical characteristics of ZnO varistors due to deterioration owing to energy absorption, and determines the optimal parameters for on-line diagnosis of the varistor. Two types of varistors were used for an accelerated aging experiment involving the application of the $8/20{\mu}s$ standard lightning impulse current. The electrical characteristics in terms of the reference voltage, total leakage current, resistive leakage current, and third-harmonic component of the total leakage current were measured, and their change rates were analyzed. The results revealed that the total leakage current increased slightly with an increase in the varistor absorbed energy, while the resistive leakage current and the third-harmonic component increased apparently. Therefore, the third-harmonic component of the total leakage current was proposed as the optimal parameter for on-line monitoring of ZnO varistor conditions.

아스팔트 2액형 점착재의 누수보수 평가에 관한 연구 (Ashpalt 2 Component Adhesive Leakage Repair Sealant Evaluation)

  • 조일규;김근허;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.140-141
    • /
    • 2017
  • This study is based on the evaluation of a single component injection type adhesive repair material and a new 2 component type used in leakage of underground concrete structures. The studies showed that based on different mix ratio of the 2 component type adhesive sealant comprised of an asphalt main and latex mixture agent the viscosity of the material compound differed significantly. Based on a permeability testing, injection and economic efficiency, and performance, the appropriate ratio was determined to be 6:1 and was proceeded to the KS F 4935 evaluation method. The 2 component type adhesive sealant uses a static mixer and a cartridge type container for the injection procedure and was able to satisfy the evaluation criteria outlined in the KS F 4935 standard.

  • PDF

열화된 고분자애자의 카올린 오손에따른 표면방전특성 (Characteristics Leakage Current of Surface Discharge according to Kaolin Contamination by Deteriorated Polymer Insulators)

  • 박재준;가평현;서의원;정명연;김희동;송일근
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1100-1103
    • /
    • 2004
  • The paper presents the results of using the fundamental and the low frequency harmonic components of leakage current to study aging of EPDM insulator for contaminated condition by kaolin. The largeer the leakage current during 200ms, the higher harmonic component at 60hz. The harmonic component at 60hz and the odd order harmonics is increase relation without Kaolin Conent. Arcing on the surface was always associated with distortion in the leakage current; hence the low frequency components of the leakage currnent can be used as a means to evaluate the surface degration. Both the fundamental and 3rd & 5th harmonics increase dry-band activity.

  • PDF

Suppression of Leakage Current and Distortion in Variable Capacitance Devices and their Application to AC Power Regulators

  • Katsuki, Akihiko;Oki, Takuya
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.66-73
    • /
    • 2016
  • The quantity of alternating current (AC) leakage and the value of distortion factor in capacitor currents are discussed with regard to a new power component called variable capacitance device (VCD). This component has terminals for controlling its capacitance. Nonlinear dielectric characteristics are utilized in this device to vary the capacitance. When VCD operates in an AC circuit, the AC leakage from this device through direct current (DC) control voltage source increases according to the conditions of DC control voltage and so on. To solve this problem, we propose techniques for suppressing AC leakage. Although VCD has strong nonlinear characteristics, the current through the capacitor is not distorted significantly. The relations between AC leakage and the distortion in current waveforms are investigated. An application example for an AC power regulator is also introduced to evaluate the distortion in waveforms.