• 제목/요약/키워드: leakage checking

검색결과 47건 처리시간 0.039초

LFSM기한의 비선형 필터 모델의 특성 (A Characteristic of Nonlinear Filter Models based on LFSMs)

  • 홍진;이동훈;지성택
    • 정보보호학회논문지
    • /
    • 제14권2호
    • /
    • pp.75-83
    • /
    • 2004
  • 본 논문에서는 잘 알려진 선형 대수 이론을 이용하여 LFSR을 활용한 LFSM의 구현 방법을 제시한다. 이를 사용하여 셀룰라 오토마타를 MFSR대신 사용하여 Anderson 정보누출과 같은 스트림 암호의 좋지 않은 성질을 제거하고자 하는 시도로는 안전성을 높일 수 없음을 보인다. 또한 LFSM에 기반한 비선형 필터 생성기가 Anderson 정보 누출의 위험성이 있는 형태로 변형 가능한지 확인하는 방법을 제시한다.

그리스 충전 덕트 내 탐상을 위한 스크류 추진 로봇 (Screw-Propelled Robot for Detecting Grease Pipe)

  • 김호중;김동선;김진현
    • 로봇학회논문지
    • /
    • 제17권2호
    • /
    • pp.178-182
    • /
    • 2022
  • Post-tension duct in nuclear reactor containment building is filled with grease to prevent steel strand from corroding. If grease leaks by break of duct, steel strand will corrode and cause problem in building safety. Therefore, grease leak should be checked preventatively. But currently used method is inefficient, since it has to remove grease and strand to check. And other methods for checking post-tension dust are not well-researched. In this paper, we develop screw-propelled robot that can move in grease and detect grease duct directly. Also, we make the test environment that is similar to real post-tension duct of containment building and test robot in that environment to verify that our robot is feasible in the post-tension duct. The robot can move forward and backward in grease duct by twin screw mechanism and has mount for sensors to detect grease leakage and strand corrosion.

옥외저장탱크 누출, 폭발 및 화재사고 대응방안에 관한 고찰 (The Study on the Countermeasure Plans about Leakage, Explosion and Fire Accidents of Atmospheric Storage Tank)

  • 이갑규
    • 한국화재소방학회논문지
    • /
    • 제30권6호
    • /
    • pp.48-56
    • /
    • 2016
  • 지난 2014.4.4.(금)14:50, 울산소재 대형 옥외저장탱크에 원유 충전 중 누출사고가 발생하여 사고현장에 긴급구조통제단이 가동됐다. 사고업체, 소방기관 및 유관기관이 지휘소에 모여 대응과 수습방안을 논의한 뒤 전원차단 및 시설작동금지, 가스농도 측정, 유증기 발생 억제, 누출 원유를 타탱크와 공정과정으로 이송, 해양오염 방지조치 등의 협업체계를 구축하여 수습하였다. 이 수습과정에서 유증기 발생방지와 점화원 차단을 가장 중시하여 조치함으로써 사고업체와 소방기관이 가장 우려했던 폭발과 화재사고는 발생하지 않았다. 이에 본 연구는 일반적인 재난의 긴급구조통제단과는 달리 운영해야 할 옥외탱크의 유류 누출, 폭발 및 화재 시의 긴급구조통제단 운영체계개선을 제시하고, 옥외탱크 유류 누출로 인한 폭발과 화재사고로 전이했을 경우를 가정한 방유제 바닥 종류에 따른 화염 확산속도와 연소시간을 실험 비교하였다. 또한, 소방차 포 노즐의 방사각도와 펌프압력에 따른 방사거리와 포의 도포면적을 실험 분석하여, 이후 옥외저장탱크의 유류 누출로 인한 폭발과 화재 시를 대비한 효과적인 현장대응과 수습방안을 제시하는 데 중점을 두었다.

자동차 에어컨 냉매 가스 누설에 대한 고장사례 고찰 (A Study of Failure Examples for Refrigerant Gas Leakage in Automotive Air Conditioner System)

  • 이일권;국창호;문학훈;유창배
    • 한국가스학회지
    • /
    • 제20권2호
    • /
    • pp.10-15
    • /
    • 2016
  • 이 논문의 목적은 자동차 에어컨 가스 누설에 관련된 고장사례를 분석하고 고찰한 것이다. 첫 번째 사례는 냉매가 누설된 상태에서 에어컨 컴프레서가 계속 작동되었다. 이로 인해 에어컨 컴프레서 내부의 피스톤이 윤활부족으로 인해 피스톤이 부분적으로 에어컨 컴프레서 내부의 실린더에 소착되는 현상이 발생하였다. 이것이 엔진작동 중 부하를 증대시켜 엔진의 회전수 변동과 함께 엔진의 작동이 정지되는 현상이 발생된 것으로 확인되었다. 두 번째 사례는 에어컨 라인과 관련 시스템을 확인한 결과 에어컨 컴프레서에서 뒤쪽으로 가는 컨덴서 고압파이프에서 미세한 균열에 의해 에어컨 냉매 가스가 누설되는 것을 확인하였다. 세 번째 사례는 에어컨 컨덴서 핀 부에서 육안으로 확인하기 어려운 미세한 크랙에 의해 컨덴서 내부 안쪽에서 에어컨 가스가 미세하게 누설되는 것을 확인하였다. 따라서, 에어컨 시스템은 에어컨 냉매가스에 의해 자동차의 실내의 온도를 낮춰 공기조화를 하는 시스템이므로 최적의 상태를 유지할 수 있도록 철저한 관리를 하도록 하여야 한다.

SAT를 이용한 정보흐름의 안전성 분석 (Security Analysis of Information Flow using SAT)

  • 김제민;고훈준
    • 디지털융복합연구
    • /
    • 제14권6호
    • /
    • pp.253-261
    • /
    • 2016
  • PC 와 모바일 기기에 있는 다양한 프로그램을 이용하여 인터넷을 이용하는 사람들이 늘어날수록 프로그램에서 개인정보 등이 유출될 가능성은 매우 높아지고 있다. 따라서 인터넷을 사용하는 프로그램에서 정보흐름의 안전성 분석을 한 후에 개인정보의 유출이 없는 안전한 프로그램을 사용해야 한다. 정보흐름의 안전성 분석은 프로그램 내에서 정보의 흐름이 안전한지 분석하는 방법으로 정보흐름이 안전하면 개인정보 유출이 없고 안전하지 않으면 개인정보 유출이 발생할 수 있다. 본 논문에서는 SAT 해결기를 활용하여 정보흐름 분석을 수행하는 방법을 제시한다. 이 방법은 보안 수준이 설정된 변수를 포함하는 프로그램을 제어와 정보흐름을 나타내는 명제 논리식으로 변환하고, SAT 해결기를 이용해 명제 논리식으로부터 만족가능성 여부를 판단한다. 판단된 결과를 통해 프로그램에서 정보흐름이 안전한지 알 수 있으며, 안전하지 않은 경우 반례를 생성하여 어느 부분에서 안전하지 않은 지 알 수 있다.

과도서지에 의한 견인전동기 고정자 코일의 상태진단 연구 (A Study on the Condition Diagnosis for the Stator Coil of Traction Motor by Transient Surge)

  • 박현준;장동욱;김길동;최종선;김정수
    • 전력전자학회논문지
    • /
    • 제8권3호
    • /
    • pp.247-252
    • /
    • 2003
  • 전동기 절연열화와 파괴는 전동기에 가해지는 스트레스에 영향을 받는다. 즉 절연물의 수명은 주어지는 스트레스의 심한 정도에 따라서 좌우된다. 전동차용 견인전동기에서도 과도서지에 의한 전기적인 열화를 검토하는 것은 매우 중요한 요소이다. 본 논문에서는 인버터에서 발생되는 과도서지에 의한 고정자 코일의 절연특성을 고찰해 보았다. 전동기의 절연상태, 열화진전도, 열화발생 범위 등을 측정하는 유용한 비파괴시험 방법에는 여러 가지가 이용되고 있다. 누설전류, 유전손실(tan$\delta$), 정전용량, 성극지수(PI), 부분방전 등의 방법들을 통하여 고정자 코일의 절연상태를 분석하였다. 이러한 진단 방법들은 전동차의 견인전동기에 대한 열화상태와 수명예측에 유용한 방법이 될 것으로 여겨진다.

크리이프를 고려한 매스콘크리트의 수화열에 대한 온도응력 해석 (Thermal Stress Analysis on ike Heat of Hydration for Mass Concrete Considering Creep Effect)

  • 김진근;이종대;김국한
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.67-72
    • /
    • 1992
  • The heat of hydration of cement causes the internal temperature rise at early age, particulary in massive concrete structures such as a footing of nuclear reactor building or a dam. As the result of the temperature rise and restraint of foundation, the thermal stress may induce cracks in concrete. Therefore, the prediction of the thermal stress is very important in the design and construction stages in order to control the cracks developed in massive concrete structures. And, in case of young concrete, creep effect by the temperature load is larger than That of old concrete. Thus the effect of creep must be considered for checking the cracks, serviceability, durability and leakage. This study is composed of two items. The first, it is to develop a finite element program which is capable of simulating the temperature history in mass concrete. The second, when the thermal stress of mass concrete structures considering creep is calculated by using the modified elastic modulus due to the inner temperature change. It is shown that the analytical results of this study is in comparably good agreement with JCI's analytical results.

  • PDF

다구찌 기법을 통한 LPG 저장탱크시공방법의 최적화에 관한 연구 (A Study on the Optimal Installation Technology of LPG Storage Tank through Taguchi Method)

  • 임사환;허용정;백승철;이종락
    • 한국안전학회지
    • /
    • 제25권6호
    • /
    • pp.98-102
    • /
    • 2010
  • LPG (Liquefied Petroleum Gas) vehicles in metropolitan area are being applied to improve air quality and have been proven effective for the reduction of air pollutant. In addition, the demand of gas as an eco-friendly energy source has being increased. With the LPG filling station is also increasing every year. These gas stations are required to install the securest storage tank because of possibility of causing huge loss of life and property. Therefore, in this paper, underground containment type is proposed as installation of the LPG storage tank using Taguchi method, which is considered to be more safe, economical, efficient, easy checking and simple construction method than any other. If leakage, economics, real estate utilization rate, safety, easy to check, simple construct about above ground, buried underground and underground containment storage tank are analyzed by Taguchi method, real estate utilization rate, economic and safety in turn are improved. Therefore, the underground containment storage tank is a optimal installation technology.

Leak flow prediction during loss of coolant accidents using deep fuzzy neural networks

  • Park, Ji Hun;An, Ye Ji;Yoo, Kwae Hwan;Na, Man Gyun
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2547-2555
    • /
    • 2021
  • The frequency of reactor coolant leakage is expected to increase over the lifetime of a nuclear power plant owing to degradation mechanisms, such as flow-acceleration corrosion and stress corrosion cracking. When loss of coolant accidents (LOCAs) occur, several parameters change rapidly depending on the size and location of the cracks. In this study, leak flow during LOCAs is predicted using a deep fuzzy neural network (DFNN) model. The DFNN model is based on fuzzy neural network (FNN) modules and has a structure where the FNN modules are sequentially connected. Because the DFNN model is based on the FNN modules, the performance factors are the number of FNN modules and the parameters of the FNN module. These parameters are determined by a least-squares method combined with a genetic algorithm; the number of FNN modules is determined automatically by cross checking a fitness function using the verification dataset output to prevent an overfitting problem. To acquire the data of LOCAs, an optimized power reactor-1000 was simulated using a modular accident analysis program code. The predicted results of the DFNN model are found to be superior to those predicted in previous works. The leak flow prediction results obtained in this study will be useful to check the core integrity in nuclear power plant during LOCAs. This information is also expected to reduce the workload of the operators.

도시철도 친환경 지하터널 배수형식의 효율적인 유지관리 방안 검토 (A study on efficient management of the drainages of underground tunnels for environmentally friendly urban railway systems)

  • 백종명;홍종헌;김한배
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1982-1990
    • /
    • 2010
  • 서울지하철 1~4호선 구간에서 부분적으로 도시터널공법을 채택하여 건설한 노선은 2~4호선으로서, 2호선 구간은 2기 지하철 건설시 시공된 신정기지 인입선 도림천~까치산역 구간 터널을 제외하고는 전체가 재래식 공법(ASSM)을 3~4호선 터널은 지형적인 여건 및 토압의 영향에 따라서 ASSM공법과 NATM공법을 병행하여 건설하였으며, 지하수 처리 형식은 지반조건과 지형적인 조건, 지하수위 저하에 의한 영향, 장기적인 운전 유지비 등을 감안하여 배수 및 비배수 형식을 적용하여야 하나, 이에 대한 충분한 사전검토 없이 채택하므로서 완전방수(비배수) 형식은 건설시에도 시공성이 떨어지고 기술적으로도 불합리한 요소를 지닌 채 설치되었으며, 부분방수(배수)형식은 배수관 기능저하, 배수구배 부적정 등으로 인해서 터널 구조물의 유지관리에서 누수와 수압에 의한 라이닝 콘크리트 균열, 박리 현상이 지속적으로 발생하여 보수 및 보강공사에 많은 비용이 소요되고 또한 터널 안정성 확보에 어려움이 있는 실정이다. 그러므로 터널 방수 형식에 대한 설계 및 시공 개념을 고찰함으로서 기술적인 문제점 등을 파악해서 유지관리의 개선 방향을 제안하고자 한다.

  • PDF