• Title/Summary/Keyword: leakage ability

Search Result 140, Processing Time 0.032 seconds

COMPARISON OF THE SEALING ABILITY OF VARIOUS ROOT CANAL FILLING TECHNIQUES (근관충전방법에 따른 폐쇄효과의 비교)

  • Lee, Dong-Kyoung;Yoon, Soo-Han;Bae, Kwang-Shik
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.346-356
    • /
    • 1998
  • The purpose of this study was to evaluate the sealing ability of various canal filling methods. Palatal roots of ninety extracted human maxillary molar teeth were resected at cementoenamel junction. Eighty of them were randomly assigned to four experimental groups, ten were served as positive and negative controls. All canals were prepared to # 40 using Profile. Experimental groups were obturated by lateral condensation technique, Thermafil technique, Continuous Wave of Condensation Technique, and down-pack & back-fill technique of Obtura-II, each with root canal sealer. Control groups were not obturated. Teeth were immersed in resorcinol-formaldehyde resin for 5 days at $4^{\circ}C$, and the resin was allowed to polymerize completely for 4 days at room temperature. Teeth were then ground horizontally at 1.5mm(level 1), 2.5mm(level 2), 3.5 mm(level 3) from the anatomical apex and examined with a stereomicroscope at ${\times}40$ magnification. The gap between the canal wall and the filling material, which was filled with the resin, was measured at each of the three levels. Each ratio of leakage was obtained by calculating the ratio of the area of the resin to the total area of the canal and was analyzed statistically (Rank-sum test). The results were as follows : 1. At the level 1, there was the greatest leakage in the Thermafil group and Obtura-II group, and the difference between the Obtura-II group and Continuous Wave of Condensation Technique group was statistically significant(p<0.05). 2. At the level 2, there was the least leakage in the Continuous Wave of Condensation Technique group, but there was no statistically significant difference between each group (p>0.05). 3. At the level 3, there was no statistically significant difference between each group(p>0.05).

  • PDF

LEAKAGE EVALUATION OF SEVERAL SEALERS USING ANAEROBIC BACTERIAL LEAKAGE MODEL (혐기성세균모델을 이용한 봉함제(Sealer)의 미세누출에 관한 연구)

  • Bae, Yong-Kue;Oh, Tae-Suk;Yoon, Soo-Han
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.2
    • /
    • pp.235-242
    • /
    • 2000
  • The purpose of this in vitro study was to evaluate the sealing ability of three sealers(Sealapex, Pulp canal sealer, AH26) used with continuous wave method using an anaerobic bacterial leakage model. 53 extracted human teeth with straight and single canals were prepared with crown-down pressureless technique using .04, .06 taper Profile(Maillefer, Swiss). Master apical file was maintained as #35 K-file. All canals of the experimental teeth were obturated with continuous wave method using System B(Analytic technology, U.S.A.) The teeth were randomly divided into three experimental groups of 15 and two control groups of 4. Experimental group 1 was obturated with Sealapex and group 2 with Pulp canal sealer, and group 3 with AH26. A dual chamber anaerobic bacterial leakage model was assembled. Brain heart infusion with yeast extract, hemin, menadion, and the chromogenic indicator bromocresol purple was used as the culture broth for Fusobacterium nucleatum(VPI 10197), The specimens were incubated in anaerobic chamber at $37^{\circ}C$ and were observed every 2 to 3 clays, The coronal leakage was evaluated through the color change of culture broth in lower chamber for 60 days. The results were as follows: 1. The incidence of bacterial leakage in group 1 (Sealapex group was 80%, 53% in group 2 (Pulp canal sealer), 27% in group 3 (AH26). 2. There were statistically significant differences in leakage scores between group 1 and group 2, and between group 1 and group 3, respectively. (P<0.05) 3. There was no significantly difference in leakage score between group 2 and group 3. (P>0 05)

  • PDF

AN IN VITRO STUDY ON MARGINAL LEAKAGE PREVENTION WITH AN ADHESIVE SEALANT (NUVA-SEAL) (변연누출방지(邊緣漏出防止)를 위한 전색재(塡塞材)[NUVA-SEAL]의 이용(利用)에 관(關)한 실험적(實驗的) 고찰(考察))

  • Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.3 no.1
    • /
    • pp.33-39
    • /
    • 1976
  • The present in vitro study was undertaken to evaluate the initial marginal sealing ability of the sealant known as Nuva-Seal to seal cavity margins when used in conjunction with Adaptic and Nuva-Fil restorative materials. The results were as follows; 1. Where each Adaptic and Nuva-Fil restorative material was filled, showed the greatest degree of marginal leakage. 2. Where Adaptic and Nuva-Fil restorative materials were filled after acid etched surrrounding enamel surface adjoining the cavity margins, showed some degree of marginal leakage. 3. Where the Nuva-Seal was applied after acid etching a) to the cavity walls and the peripheral enamel surface adjoining the cavity margins, b) only to the surrounding enamel surface adjoining the cavity margins, and c) over the restorations and the peripheral enamel surface, showed complete absence of marginal leakage of Adaptic and Nuva-Fil restorative materials. 4. Where the Nuva-Seal was applied with the same methods as above, and restorations were placed on thermal stress also showed complete absence of marginal leakage of Adaptic and Nuva-Fil restorative materials.

  • PDF

The effect of thermocycling on the bonding of different restorative materials to access opening through porcelain fused to metal restorations

  • Al-Moaleem, Mohammed M.;Shah, Farhan Khalid;Khan, Nausheen Saied;Porwal, Amit
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.4
    • /
    • pp.186-189
    • /
    • 2011
  • PURPOSE. Porcelain fused to metal (PFM) crowns provide the best treatment option for teeth that have a large or defective restoration. More than 20% of teeth with PFM crowns or bridges require non-surgical root canal treatment (NSRCT). This may be due to the effect of restorative procedures and the possible leakage of bacteria and or their by-products, which leads to the demise of the tooth pulp. Thus, this study was planned to compare the ability of the restorative materials to seal perforated PFM specimens. MATERIALS AND METHODS. The study evaluates the ability of amalgam, composite or compomer restorative materials to close perforated PFM specimen's in-vitro. Ninety PFM specimens were constructed using Ni-Cr alloys and feldspathic porcelain, and then they were divided into 3 groups: amalgam (A), composite + Exite adhesive bond (B) and compomer + Syntac adhesive bond (C). All the PFM samples were embedded in an acrylic block to provide complete sealing of the hole from the bottom side. After the aging period, each group was further divided into 3 equal subgroups according to the thermocycling period (one week for 70 cycles, one month for 300 cycles and three months for 900 cycles). Each subgroup was put into containers containing dye (Pelikan INK), one maintained at $5^{\circ}C$ and the other at $55^{\circ}C$, each cycle for 30 sec time. The data obtained was analyzed by SPSS, 2006 using one way ANOVA test and student t-test and significant difference level at (P<.01). RESULTS. The depth of dye penetration was measured at the interfaces of PFM and filling materials using Co-ordinate Vernier Microscope. The lowest levels of the dye penetration for the three groups, as well as subgroups were during the first week. The values of dye leakage had significantly increased by time intervals in subgroups A and C. CONCLUSION. It was seen that amalgam showed higher leakage than composite while compomer showed the lowest level of leakage.

EVALUATION OF THE SEALING ABILITY OF Microseal® OBTURATION TECHNIQUE (Microseal®을 이용한 근관충전법의 근관폐쇄능력 평가)

  • Oh, Tea-Seok;Yoo, Hyeon-Mee;Hwang, Hea-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.682-689
    • /
    • 1998
  • The purpose of this study was to evaluate the sealing ability of the Microseal$^{(R)}$, which was new obturation system made by Tycom company, U.S.A. Forty-five extracted single-rooted human teeth were resected at cemento-enamel junction and divided three groups. All canals were prepared using Profile system, and then each group was obturated by lateral condensation technique (group 1), vertical condensation technique (group 2) and Microseal$^{(R)}$ condensation technique (group 3) with root canal sealer. Teeth were immersed in resorcinol-formaldehyde resin for 5 days at $4^{\circ}C$ and the resin was allowed to polymerize completely for 4 days at room temperature. Teeth were resected horizontally at 1 mm (level I), 2 mm (level II), 3 mm (level III) from the anatomical root apex using low speed microtome and examined with Image analyzer (IBASR, Zeiss co., Germany.) at ${\times}25$ magnification. The gab between the canal wall and the filling material, which was filled with the resin, was measured at each of the three levels. Each ratio of leakage was expressed percentage by calculating the ratio of the area of the resin to the total area of the canal and was analyzed statistically (one-way ANOVA). The results were as follows; 1. The mean ratio of leakage (%) was 6.46% at group 1, 3.06% at group 2, 11.27% at group 3. 2. When evaluating the ratio of leakage at the three levels, there was level I> level II> level III in all groups. Especially, the difference between level I and level III was statistically significant (p<0.05). 3. When evaluating the ratio of leakage at the three groups, there was group 3> group 1> group 2 at all levels. Especially the difference between group 2 and group 3 was statistically significant (p<0.05).

  • PDF

An Analysis of Compliance with Information Security Policy Effects on Information Security Ability and Behavior : Focused on Workers of Shipping and Port Organization (정보보안정책 준수가 정보보안능력 및 행동에 미치는 영향 분석 : 해운항만조직 구성원을 대상으로)

  • Kang, Dayeon;Chang, Myunghee
    • Journal of Korea Port Economic Association
    • /
    • v.30 no.1
    • /
    • pp.97-118
    • /
    • 2014
  • Recent accidents of customer information leakage increase the necessity of information security for organization and the importance of information security team for it. To strengthen information security, organizations make information security policy and ask the members to comply with it. In this regard, maritime organization also needs to structure information security policy and examine its ability and behavior. The purpose of this study is to analyze the effects of compliance with information security policy on the ability and behavior of workers in shipping and port organization. The results of investigation show that information security education and norm affect compliance with information security of the workers. On the contrary, the punishment of information security is insignificant. It is shown that the degree of compliance with information security significantly affects its ability and behavior of the workers in shipping and port organization.

FinFET SRAM Cells with Asymmetrical Bitline Access Transistors for Enhanced Read Stability

  • Salahuddin, Shairfe Muhammad;Kursun, Volkan;Jiao, Hailong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.6
    • /
    • pp.293-302
    • /
    • 2015
  • Degraded data stability, weaker write ability, and increased leakage power consumption are the primary concerns in scaled static random-access memory (SRAM) circuits. Two new SRAM cells are proposed in this paper for achieving enhanced read data stability and lower leakage power consumption in memory circuits. The bitline access transistors are asymmetrically gate-underlapped in the proposed SRAM cells. The strengths of the asymmetric bitline access transistors are weakened during read operations and enhanced during write operations, as the direction of current flow is reversed. With the proposed hybrid asymmetric SRAM cells, the read data stability is enhanced by up to 71.6% and leakage power consumption is suppressed up to 15.5%, while displaying similar write voltage margin and maintaining identical silicon area as compared to the conventional memory cells in a 15 nm FinFET technology.

Effect of moisture on sealing ability of root canal filling with different types of sealer through the glucose penetration model (수종의 실러를 이용한 근관 충전 시 근관 내 수분이 치근단 폐쇄효과에 미치는 영향)

  • Jang, Jin-Ah;Kim, Hee-Lyang;Her, Mi-Ja;Lee, Kwang-Won;Yu, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.335-343
    • /
    • 2010
  • Objectives: To compared the effect of different levels of moisture of root canal on the sealing ability after filling with four different types of sealer. Materials and Methods: Single-rooted teeth (n = 90) instrumented to and apical size of 0.06 / 45 were randomly assigned to 12 experimental groups (n = 7 per group), positive/negative control groups (n = 3 per group). The teeth of the experimental groups (a. DRY; b. PAPER POINT DRY; c. WET) were obturated with sealer (Group 1-3: Sealapex; Group 4-6: AH plus; Group 7-9: Tubuli-seal; Group 10-12: EndoRez) and warm vertical compaction method. After 7 days in $37^{\circ}C$, 100% humidity, the coronal-to-apical microleakage was evaluated quantitatively using a glucose leakage model. The leaked glucose concentration was measured with spectrophotometer at 1, 3, 7, 14, 21, and 30 days. Data were recorded ad mmol/L and statistically analysed with the two-way ANOVA and Duncan test (p = 0.05). Results: Throughout the experimental period Tubuli-seal/WET (Group 9) showed the highest mean cumulative glucose penetration (178.75 mmol/L), whereas AH plus/DRY (Group 4) had the least (20.78 mmol/L). Conclusions: The results of this study demonstrated that the moisture condition of root canals at the time of obturation and the type of sealer that was used had a significant effect on leakage and sealing ability. Thus drying procedure according to sealer types is a critical step and should not be missed in endodontic treatment.

A Study on a Leakage Sensing Pipe and Monitoring System Using TDR in GIS (GIS상에서 TDR을 사용한 누수감지관과 모니터링 시스템에 관한 연구)

  • 강병모;홍인식
    • Journal of Korea Multimedia Society
    • /
    • v.7 no.4
    • /
    • pp.567-578
    • /
    • 2004
  • GIS technique enhanced a space data manipulation ability and we are offering a geographic information service through various analysis. The quantity used of the water was increased in such situation according to a population increase and a city concentration phenomenon. But, to secure clear water are difficult, owing to the water shortage phenomenon, seepage and the quality of water change for worse. We decide the seepage and the system to retrieve the seepage location using GIS in order to reduce vast loss from the seepage. In this paper we proposed Leakage Sensing System using TDR technology in GIS, constructed a GIS database and pilot system to prove the validity, and simulated it using TDR in GIS.

  • PDF

A Study on the Explosive Plugging of A Repair for Defective Tube/Tubeplate on the Nuclear Steam Generator (원자력 증기발생기 결함 세관 보수용 폭발 Plugging에 관한 연구)

  • 이병일;심상한;강정윤;이상래
    • Explosives and Blasting
    • /
    • v.17 no.4
    • /
    • pp.18-31
    • /
    • 1999
  • The explosive forming has been used for many year to expand tubes into tubesheets. this process has demonstrated ability to direct carefully the energy of an explosive to expand tubes into tubesheet holes without damaging the tubesheet and without causing the excessive cold work at the tube I.D. that is normally associated with mechanical expansion. The success of explosive tube expansion provided the background for the development of the explosive tube plug. The main results are as follows : (1) The optimum explosives and explosive qualities are PETN, RDX, HMS and about 18~31gr/ft of explosive plugging in nuclear steam generator. (2) Explosive plugging's thickness is 0.9~1.8mm. If groove of 0.4 mm formed in plug outside, For the hydraulic leakage is go up, explosive plugging of formed groove are applicate tube and tubrplate. (3) Sheath is designed on the polyethylene of low density, In thermal impact test of the $430^\circ{C}$, hydraulic leakage is $300kg/cm^2$. (4) About 10~60mm oxide inclusions are existed on the space of explosive plug and tube protect to the leakage.

  • PDF