• Title/Summary/Keyword: leak

Search Result 1,484, Processing Time 0.025 seconds

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Outpatient Chest Tube Management with Using a Panda Pneumothorax Set with a Heimlich Valve (Panda Pneumothorax Set with Heimlich Valve에 의한 외래에서의 흉관 관리)

  • Choi, Soon-Ho;Lee, Mi-Kyung;Ryu, Dae-Woong
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.497-501
    • /
    • 2009
  • Background: Prolonged air leakage and pleural fluid drainage from a chest tube may delay removing the chest tube after a patient undergoes video-assisted thoracoscopic wedge resection and the patient is otherwise ready for discharge. We reviewed 37 outpatients patients who were being managed with a postoperative chest tube (a Panda Pneumothorax set with a Heimlich valve). Material and Method: From January 2005 to December 2007, 294 patients underwent video-assisted thoracoscopic wedge resections & pleurodesis. Of them, 37 patients met the criteria for outpatient chest drainage management with using a Panda Pneumothorax set with a Heimlich valve. The patients received written instructions, and they demonstrated competence with using the Panda system. The patients returned for chest tube removal after satisfactory resolution of their air leak and pleural fluid drainage. Result: The patients discharged with a Panda pneumothorax set had a longer duration of hospital stay (mean: 10.3$\pm$1.7 days, range: 11 to 17 days) as compared with the patients without a Panda pneumothorax set (mean: 6.2$\pm$1.5 days, range: 4 to 7 days). The chest tube was removed successfully from the patients with a Panda pneumothorax set at an average of 9.8$\pm$1.6 days (range: 9$\sim$18 days) after discharge. There were no major complications. Four patients experienced minor complications. Thirty six patients (97.3%) experienced uneventful and successful outpatient chest tube management. Conclusion: Successful postoperative outpatient chest tube management with using the Panda set was accomplished in 36 selected patients. This program resulted in a substantially reduced hospital cost and enhanced patient satisfaction by allowing earlier discharge.

Retrospective Study of Thoracoscopic Apical Pleurectomy and Mechanical Pleural Abrasion for Spontaneous Pneumothorax (기흉 수술시 흉강경하 첨부 늑막 절제술과 기계적 흉막 유착술의 후향적 비교)

  • Kim, Dong-Hyun;Kim, Hyun-Jo;Han, Jung-Wook;Youm, Wook
    • Journal of Chest Surgery
    • /
    • v.43 no.4
    • /
    • pp.404-408
    • /
    • 2010
  • Background: Pleural symphysis is regarded as an important treatment option in reducing recurrence rates after surgical treatment of spontaneous pneumothorax. However, there is much debate over the best method for achieving pleural symphysis. We retrospectively compared apical pleurectomy (AP) with mechanical pleural abrasion (MPA). Material and Method: Between January 2000 and December 2007, 83 patients underwent video-assisted thoracoscopic surgery (VATS) for spontaneous pneumothorax. In addition to wedge resection of bullae, MPA was performed in 21 patients (group A) and AP in 62 patients (group B). Result: There were no significant differences in age, gender and site of pneumothorax between the two groups. Operative time was $97{\pm}44$ minutes in group A and $77{\pm}18$ minutes in group B (p>0.05). The mean amount of pleural drainage through the chest tube on the first postoperative day was $156{\pm}87 cc$ in group A and $147{\pm}87 cc$ in group B (p>0.05). There was no mortality or significant morbidity in all patients with the exception of reoperation for bleeding in two patients in group B. In the postoperative course, there were no statistical differences between the two groups in the rate of residual air space, air leak and indwelling time of chest tube, and hospital stay. Mean follow up time was $31.7{\pm}25.3$ months, and the recurrence rate of pneumothorax was 9.5% (2/21) in group A and 6.5% (4/62) in group B, without statistical significance. Conclusion: AP was no more advantageous than MPA in terms of operative time, postoperative course and prevention of recurrent pneumothorax. Therefore, complete resection of bullae and existence of residual bullae are more important factors in reducing the incidence of recurrent pneumothorax than pleural symphysis.

Surgical Treatment of the Congenital Esophageal Atresia (선천성 식도 폐쇄증의 외과적 치료)

  • 최필조;전희재;이용훈;조광조;성시찬;우종수
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.567-572
    • /
    • 1999
  • Background: Surgical correction of the full spectrum of esophageal atresia with tracheoesophageal fistula has improved over the years, but the mortality and morbidity assoiated with repair of these anomalies still remains high. Material and Method: We retrospectively analyzes 27 surgically treated patients with esophageal atresia and tracheoesophageal fistula at Dong-A University Hospital between January 1992 and March 1997. Result: There were 21 male and 6 female patients. Mean birth weight was 2.62$\pm$.385 kg(2.0~3.4 kg). Twenty- four(88.9%) had esophageal atresia with distal tracheoesophageal fistula, and 3(11.1%) had pure esophageal atresia. Four(14.8%) infants were allocated to Waterston risk group A, 18(66.7%) to group B, and 5(18.5%) to group C. In eighteen(66.7%) infants with associated anomalies, cardiovascular anomalies were the most common. Three had a gap length of 3.5 cm or greater(ultra-long gap) between esophageal segments, 7 had 2.0 to 3.5 cm(long gap), 8 had 1.0 to 2.0 cm(medium gap), and 9 had 1 cm or less(short gap) gap length. Among 27 neonates, 3 cases underwent staged operation, late colon interposition was done in 2, and all other 24 cases underwent primary esophageal anastomosis. Oerative mortality was 2/27(7.4%). Causes of death included acute renal failure(n=1), empyema from anastomotic leak(n=1), necrotizing enterocolitis(n=1), sepsis(n=1), insulin-dependent diabetus mellitus(n=1 . There were 4 anastomosis- related complications including stricture in 3, leakage in 1. Mortality was related to the gap length(p<.05). Conclusion: Although the complication rate associated with surgical repair of these anomalies is high, this does not always implicate the operative mortality. The overall survival can be improved by effective treatment for combined anomalies and intensive postoperatve care.

  • PDF

A Numerical Study on the CO2 Leakage Through the Fault During Offshore Carbon Sequestration (해양지중에 저장된 이산화탄소의 단층을 통한 누출 위험 평가에 관한 수치해석 연구)

  • Kang, Kwangu;Huh, Cheol;Kang, Seong-Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.2
    • /
    • pp.94-101
    • /
    • 2015
  • To mitigate the greenhouse gas emission, many carbon capture and storage projects are underway all over the world. In Korea, many studies focus on the storage of $CO_2$ in the offshore sediment. Assurance of safety is one of the most important issues in the geological storage of $CO_2$. Especially, the assessment of possibility of leakage and amount of leaked $CO_2$ is very crucial to analyze the safety of marine geological storage of $CO_2$. In this study, the leakage of injected $CO_2$ through fault was numerically studied. TOUGH2-MP ECO2N was used to simulate the subsurface behavior of injected $CO_2$. The storage site was 150 m thick saline aquifer located 825 m under the continental shelf. It was assumed that $CO_2$ leak was happened through the fault located 1,000 m away from the injection well. The injected $CO_2$ could migrate through the aquifer by both pressure difference driven by injection and buoyancy force. The enough pressure differences made it possible the $CO_2$ to migrate to the bottom of the fault. The $CO_2$ could be leaked to seabed through the fault due to the buoyancy force. Prior to leakage of the injected $CO_2$, the formation water leaked to seabed. When $CO_2$ reached the seabed, leakage of formation water stopped but the same amount of sea water starts to flow into the underground as the amount of leaked $CO_2$. To analyze the effect of injection rate on the leakage behavior, the injection rate of $CO_2$ was varied as 0.5, 0.75, and $1MtCO_2/year$. The starting times of leakage at 1, 0.75 and $0.5MtCO_2/year$ injection rates are 11.3, 15.6 and 23.2 years after the injection, respectively. The leakage of $CO_2$ to the seabed continued for a period time after the end of $CO_2$ injection. The ratios of total leaked $CO_2$ to total injected $CO_2$ at 1, 0.75 and $0.5MtCO_2/year$ injection rates are 19.5%, 11.5% and 2.8%, respectively.

The Impact of Perceived Risks Upon Consumer Trust and Purchase Intentions (인지된 위험의 유형이 소비자 신뢰 및 온라인 구매의도에 미치는 영향)

  • Hong, Il-Yoo B.;Kim, Woo-Sung;Lim, Byung-Ha
    • Asia pacific journal of information systems
    • /
    • v.21 no.4
    • /
    • pp.1-25
    • /
    • 2011
  • Internet-based commerce has undergone an explosive growth over the past decade as consumers today find it more economical as well as more convenient to shop online. Nevertheless, the shift in the common mode of shopping from offline to online commerce has caused consumers to have worries over such issues as private information leakage, online fraud, discrepancy in product quality and grade, unsuccessful delivery, and so forth, Numerous studies have been undertaken to examine the role of perceived risk as a chief barrier to online purchases and to understand the theoretical relationships among perceived risk, trust and purchase intentions, However, most studies focus on empirically investigating the effects of trust on perceived risk, with little attention devoted to the effects of perceived risk on trust, While the influence trust has on perceived risk is worth studying, the influence in the opposite direction is equally important, enabling insights into the potential of perceived risk as a prohibitor of trust, According to Pavlou (2003), the primary source of the perceived risk is either the technological uncertainty of the Internet environment or the behavioral uncertainty of the transaction partner. Due to such types of uncertainty, an increase in the worries over the perceived risk may negatively affect trust, For example, if a consumer who sends sensitive transaction data over Internet is concerned that his or her private information may leak out because of the lack of security, trust may decrease (Olivero and Lunt, 2004), By the same token, if the consumer feels that the online merchant has the potential to profit by behaving in an opportunistic manner taking advantage of the remote, impersonal nature of online commerce, then it is unlikely that the merchant will be trusted, That is, the more the probable danger is likely to occur, the less trust and the greater need to control the transaction (Olivero and Lunt, 2004), In summary, a review of the related studies indicates that while some researchers looked at the influence of overall perceived risk on trust level, not much attention has been given to the effects of different types of perceived risk, In this context the present research aims at addressing the need to study how trust is affected by different types of perceived risk, We classified perceived risk into six different types based on the literature, and empirically analyzed the impact of each type of perceived risk upon consumer trust in an online merchant and further its impact upon purchase intentions. To meet our research objectives, we developed a conceptual model depicting the nomological structure of the relationships among our research variables, and also formulated a total of seven hypotheses. The model and hypotheses were tested using an empirical analysis based on a questionnaire survey of 206 college students. The reliability was evaluated via Cronbach's alphas, the minimum of which was found to be 0.73, and therefore the questionnaire items are all deemed reliable. In addition, the results of confirmatory factor analysis (CFA) designed to check the validity of the measurement model indicate that the convergent, discriminate, and nomological validities of the model are all acceptable. The structural equation modeling analysis to test the hypotheses yielded the following results. Of the first six hypotheses (H1-1 through H1-6) designed to examine the relationships between each risk type and trust, three hypotheses including H1-1 (performance risk ${\rightarrow}$ trust), H1-2 (psychological risk ${\rightarrow}$ trust) and H1-5 (online payment risk ${\rightarrow}$ trust) were supported with path coefficients of -0.30, -0.27 and -0.16 respectively. Finally, H2 (trust ${\rightarrow}$ purchase intentions) was supported with relatively high path coefficients of 0.73. Results of the empirical study offer the following findings and implications. First. it was found that it was performance risk, psychological risk and online payment risk that have a statistically significant influence upon consumer trust in an online merchant. It implies that a consumer may find an online merchant untrustworthy if either the product quality or the product grade does not match his or her expectations. For that reason, online merchants including digital storefronts and e-marketplaces are suggested to pursue a strategy focusing on identifying the target customers and offering products that they feel best meet performance and psychological needs of those customers. Thus, they should do their best to make it widely known that their products are of as good quality and grade as those purchased from offline department stores. In addition, it may be inferred that today's online consumers remain concerned about the security of the online commerce environment due to the repeated occurrences of hacking or private information leakage. Online merchants should take steps to remove potential vulnerabilities and provide online notices to emphasize that their website is secure. Second, consumer's overall trust was found to have a statistically significant influence on purchase intentions. This finding, which is consistent with the results of numerous prior studies, suggests that increased sales will become a reality only with enhanced consumer trust.

The Effects of Diluted Fibrin Glue about Continuous Air Leakage after Lung Surgery (폐수술 후 지속적 공기누출에 희석한 Fibrin Glue의 효과)

  • Choi Chang-Woo;Lee Seong-Jin;Lee Chol-Sae;Lee Kihl-Rho;Lee Seock-Yeol
    • Journal of Chest Surgery
    • /
    • v.39 no.10 s.267
    • /
    • pp.770-774
    • /
    • 2006
  • Background: Continuous air leakage through chest tube after lung surgery may increase pt's hospital stay and lead to many complications including empyema etc. Chemical pleurodesis has frequently been used for prevention of air leakage. Therefore, we performed chemical pleurodesis using diluted fibrin glue in patients with continuous air leak-age and observed the effects and efficiency of treatment. Material and Method: From September, 2001 to August, 2005, 16 patients whose continuous air leakage lasted more than 7 days underwent chemical pleurodesis with diluted fibrin glue. The effects of treatment, complications and recurrences were reviewed. Dissolved fibrinogen 1.0 g and aprotinin 500,000 KIU were mixed in a 50 cc syringe (Mixed solution A). And dissolved thrombin 5,000 IU and Calcium chloride 600 mg were mixed in a 50 cc syringe (Mixed solution B). Cefazolin 1.0 g was mixed in a 50 cc syringe (Mixed solution C). Rubber tube was inserted between the chest tube and the collecting bottle. An inserted rubber tube was positioned 60cm above the patient and forming a loop appearance was done. Mixed solutions A, B and C were injected into the highest rubber tube. Results: Continuous air leakages disappeared in all f6 patients at next day. Chest tubes were removed after 3 days in all patients. Complications were chest pain in 12 patients (75%), leukocytosis in 14 patients (88%), fever and chill in 14 patients (88%). All complications were transient and disappeared without specific treatment. Conclusion: Our findings demonstrated that diluted fibrin glue chemical pleurodesis was effective in patients with continuous air leakage lasting more than 7 days. Diluted fibrin glue chemical pleurodesis had good results with acceptable complications. long term follow-up is necessary to evaluate the accurate effects of treatment and recurrence in a large number of patients.

Numerical Modelling for the Dilation Flow of Gas in a Bentonite Buffer Material: DECOVALEX-2019 Task A (벤토나이트 완충재에서의 기체 팽창 흐름 수치 모델링: DECOVALEX-2019 Task A)

  • Lee, Jaewon;Lee, Changsoo;Kim, Geon Young
    • Tunnel and Underground Space
    • /
    • v.30 no.4
    • /
    • pp.382-393
    • /
    • 2020
  • The engineered barrier system of high-level radioactive waste disposal must maintain its performance in the long term, because it must play a role in slowing the rate of leakage to the surrounding rock mass even if a radionuclide leak occurs from the canister. In particular, it is very important to clarify gas dilation flow phenomenon clearly, that occurs only in a medium containing a large amount of clay material such as a bentonite buffer, which can affect the long-term performance of the bentonite buffer. Accordingly, DECOVALEX-2019 Task A was conducted to identify the hydraulic-mechanical mechanism for the dilation flow, and to develop and verify a new numerical analysis technique for quantitative evaluation of gas migration phenomena. In this study, based on the conventional two-phase flow and mechanical behavior with effective stresses in the porous medium, the hydraulic-mechanical model was developed considering the concept of damage to simulate the formation of micro-cracks and expansion of the medium and the corresponding change in the hydraulic properties. Model verification and validation were conducted through comparison with the results of 1D and 3D gas injection tests. As a result of the numerical analysis, it was possible to model the sudden increase in pore water pressure, stress, gas inflow and outflow rate due to the dilation flow induced by gas pressure, however, the influence of the hydraulic-mechanical interaction was underestimated. Nevertheless, this study can provide a preliminary model for the dilation flow and a basis for developing an advanced model. It is believed that it can be used not only for analyzing data from laboratory and field tests, but also for long-term performance evaluation of the high-level radioactive waste disposal system.

Wearable Computers

  • Cho, Gil-Soo;Barfield, Woodrow;Baird, Kevin
    • Fiber Technology and Industry
    • /
    • v.2 no.4
    • /
    • pp.490-508
    • /
    • 1998
  • One of the latest fields of research in the area of output devices is tactual display devices [13,31]. These tactual or haptic devices allow the user to receive haptic feedback output from a variety of sources. This allows the user to actually feel virtual objects and manipulate them by touch. This is an emerging technology and will be instrumental in enhancing the realism of wearable augmented environments for certain applications. Tactual displays have previously been used for scientific visualization in virtual environments by chemists and engineers to improve perception and understanding of force fields and of world models populated with the impenetrable. In addition to tactual displays, the use of wearable audio displays that allow sound to be spatialized are being developed. With wearable computers, designers will soon be able to pair spatialized sound to virtual representations of objects when appropriate to make the wearable computer experience even more realistic to the user. Furthermore, as the number and complexity of wearable computing applications continues to grow, there will be increasing needs for systems that are faster, lighter, and have higher resolution displays. Better networking technology will also need to be developed to allow all users of wearable computers to have high bandwidth connections for real time information gathering and collaboration. In addition to the technology advances that make users need to wear computers in everyday life, there is also the desire to have users want to wear their computers. In order to do this, wearable computing needs to be unobtrusive and socially acceptable. By making wearables smaller and lighter, or actually embedding them in clothing, users can conceal them easily and wear them comfortably. The military is currently working on the development of the Personal Information Carrier (PIC) or digital dog tag. The PIC is a small electronic storage device containing medical information about the wearer. While old military dog tags contained only 5 lines of information, the digital tags may contain volumes of multi-media information including medical history, X-rays, and cardiograms. Using hand held devices in the field, medics would be able to call this information up in real time for better treatment. A fully functional transmittable device is still years off, but this technology once developed in the military, could be adapted tp civilian users and provide ant information, medical or otherwise, in a portable, not obstructive, and fashionable way. Another future device that could increase safety and well being of its users is the nose on-a-chip developed by the Oak Ridge National Lab in Tennessee. This tiny digital silicon chip about the size of a dime, is capable of 'smelling' natural gas leaks in stoves, heaters, and other appliances. It can also detect dangerous levels of carbon monoxide. This device can also be configured to notify the fire department when a leak is detected. This nose chip should be commercially available within 2 years, and is inexpensive, requires low power, and is very sensitive. Along with gas detection capabilities, this device may someday also be configured to detect smoke and other harmful gases. By embedding this chip into workers uniforms, name tags, etc., this could be a lifesaving computational accessory. In addition to the future safety technology soon to be available as accessories are devices that are for entertainment and security. The LCI computer group is developing a Smartpen, that electronically verifies a user's signature. With the increase in credit card use and the rise in forgeries, is the need for commercial industries to constantly verify signatures. This Smartpen writes like a normal pen but uses sensors to detect the motion of the pen as the user signs their name to authenticate the signature. This computational accessory should be available in 1999, and would bring increased peace of mind to consumers and vendors alike. In the entertainment domain, Panasonic is creating the first portable hand-held DVD player. This device weight less than 3 pounds and has a screen about 6' across. The color LCD has the same 16:9 aspect ratio of a cinema screen and supports a high resolution of 280,000 pixels and stereo sound. The player can play standard DVD movies and has a hour battery life for mobile use. To summarize, in this paper we presented concepts related to the design and use of wearable computers with extensions to smart spaces. For some time, researchers in telerobotics have used computer graphics to enhance remote scenes. Recent advances in augmented reality displays make it possible to enhance the user's local environment with 'information'. As shown in this paper, there are many application areas for this technology such as medicine, manufacturing, training, and recreation. Wearable computers allow a much closer association of information with the user. By embedding sensors in the wearable to allow it to see what the user sees, hear what the user hears, sense the user's physical state, and analyze what the user is typing, an intelligent agent may be able to analyze what the user is doing and try to predict the resources he will need next or in the near future. Using this information, the agent may download files, reserve communications bandwidth, post reminders, or automatically send updates to colleagues to help facilitate the user's daily interactions. This intelligent wearable computer would be able to act as a personal assistant, who is always around, knows the user's personal preferences and tastes, and tries to streamline interactions with the rest of the world.

  • PDF

Cytosolic Phospholipase A2 Activity in Neutrophilic Oxidative Stress of Platelet-activating Factor-induced Acute Lung Injury (Platelet-activating Factor에 의한 급성폐손상에서 호중구성 산화성 스트레스에 관여하는 Cytosolic Phospholipase A2 활성도의 변화)

  • Kwon, Young Shik;Hyun, Dae Sung;Lee, Young Man
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.6
    • /
    • pp.497-506
    • /
    • 2007
  • Background: The present investigation was performed in rats and isolated human neutrophils in order to confirm the presumptive role of the positive feedback loop of cytosolic phospholipase $A_2$ ($cPLA_2$) activation by plateletactivating factor (PAF). Methods: The possible formation of the positive feedback loop of the $cPLA_2$ activation and neutrophilic respiratory burst was investigated in vivo and in vitro by measurement of the parameters denoting acute lung injury. In addition, morphological examinations and electron microscopic cytochemistry were performed for the detection of free radicals in the lung. Results: Five hours after intratracheal instillation of PAF ($5{\mu}g/rat$), the lung leak index, lung myeloperoxidase (MPO) activity, the number of neutrophils and the concentration of cytokine-induced neutrophil chemoattractant (CINC) in bronchoalveolar lavage fluid were increased by PAF as compared with those of control rats. The NBT assay and cytochrome-c reduction assay revealed an increased neutrophilic respiratory burst in isolated human neutrophils following exposure to PAF. Lung and neutrophilic $cPLA_2$ activity were increased following PAF exposure and exposure to hydrogen peroxide increased $cPLA_2$ activity in the lung. Histologically, inflammatory findings of the lung were observed after PAF treatment. Remarkably, as determined by $CeCl_3$ cytochemical electron microscopy, increased production of hydrogen peroxide was identified in the lung after PAF treatment. Conclusion: PAF mediates acute oxidative lung injury by the activation of $cPLA_2$, which may provoke the generation of free radicals in neutrophils.