• 제목/요약/키워드: leader discharge

검색결과 18건 처리시간 0.018초

낙뢰 리더의 대지부착과정에 대한 기초적 연구 (A Basic Study on the Attachment Process of Lightning Leader to Ground)

  • 유양우;김승민;김유하;이복희
    • 조명전기설비학회논문지
    • /
    • 제28권10호
    • /
    • pp.82-88
    • /
    • 2014
  • This paper presents the results of model tests for the attachment process of lightning leader to ground which is one of poorly understood processes of cloud-to-ground lightning discharges. In order to simulate the attachment process of lightning leader to ground, we investigated the discharge characteristics of air gap between the tip of needle-shaped electrode and the soil surface as a parameter of moisture content in soils when the positive and negative $1.2/50{\mu}s$ lightning impulse voltages are applied. The breakdown voltage and the discharge light were observed. As a result, the attachment processes of lightning leader to ground are strongly dependent on the grain size and the moisture content of soils. The time to breakdown was shortened with increasing the magnitude of incident impulse voltages. The delay time from application of the highest voltage to breakdown in sand is shortened with increasing the moisture content. The delay time from application of the voltage to breakdown in gravel varied from about $0.5{\mu}s$ to several ${\mu}s$. As the moisture content in soil increases, the breakdown voltages are decreased and the breakdown voltage versus time to breakdown curves are shifted toward the lower side. The results obtained in this work are similar to those for non-uniform air gap stressed by lightning impulse voltages.

초고압 $SF_6$가스중의 선구방전기구 (Precursor Discharge Mechanism under EHV in $SF_6$ Gas)

  • 이형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1807-1809
    • /
    • 1996
  • The axial discharge at switching operations of EHV $SF_6$ disconnector can lead to the breakdown to the enclosure. Precursor in periphery zone leads to formation of leader over some time delay. Injected charge value depends on electric field and gap geometry. The calculation method for parameters of $SF_6$ insulation for DS in EHV-GIS is suggested by using the new criterion of leader inception in connection with periphery field nearby the boundary of streamer zone.

  • PDF

Fast, Upward, Long-Lasting, Transit Echoes as an Evidence of New-Type of Meteor-Trail Leader Discharge in the Summer Polar Upper Mesosphere

  • Lee, Young-Sook;Kirkwood, Sheila;Kwak, Young-Sil
    • Journal of Astronomy and Space Sciences
    • /
    • 제35권2호
    • /
    • pp.93-103
    • /
    • 2018
  • Non-specular, vertically upward transit, fast-moving radar echoes are observed in the summer polar upper mesosphere near 90 km using 52 MHz VHF radar at Esrange, Sweden. By resolving maximum echo power movement, the unusual meteor trails propagate vertically upward with taking horizontal displacements at an initial speed of 10 km/s exponentially decreasing with increasing height from 85-89 km, lasting for 3.5 sec. Another upward transit is observed as following a downward transit echo target in about ~1 sec, lasting over 5 sec. The upward motion cannot be explained with the dynamics of penetrating meteors or by atmospheric dynamics. The observation proposes that secondary produced plasma jets occurring from meteor trail are possibly responsible for upward fast moving echoes. The long-lasting (3-5 sec), ascending meteor trails at speeds of a few $10^4m/s$ are distinctive from any previous occurrences of meteors or upper atmospheric electrical discharges in the aspect of long-lasting upward/downward motions. This result possibly suggests a new type of meteor-trail leader discharge occurring in the summer polar upper mesosphere and lower thermosphere.

Performance Evaluation of Early Streamer Emission Lightning Air Terminal

  • Choi, Sang-Won;Her, Yong
    • International Journal of Safety
    • /
    • 제5권2호
    • /
    • pp.18-23
    • /
    • 2006
  • Studies have claimed that ESE (Early Streamer Emission) air terminals offer a vastly increased zone of protection over that of traditional lightning rods (Franklin rods) by causing the emission of an upward streamer/leader: The upward streamer/leader will propagate towards the tip of the downward leader at an early stage in the attachment process.. This paper shows the results of a performance evaluation test of a particular type of the ESE air terminal (called "ElecHippo") with a simple rod tested at the Korea Electrotechnology Research Institute (KERI). The corona emission current of the ElecHippo made by Yong-Jin Enterprise Corp. has also been measured at the Occupational Safety & Health Research Institute (OSHRI). The results show that the ElecHippo meets the French standard of NFC 17-102-1995. The results also verify the ESE performance by measuring the ion emission current generated in the discharge electrode gap as a function of the capacitance and inductance of the equipped devices. Finally, we propose a new method for grounding the system to reduce the lightning damage by combining the ESE air terminal, the early discharge earth plate, the lightning strike recorder and the surge protection device.

$SF_6$ 기체와 $SF_{6}-N_{2}$ 혼합기체의 초기코로나 특성 (The first corona inception characteristics in $SF_6$ gas and $SF_{6}-N_{2}$ mixtures)

  • 이복희;김정일;박성환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2002-2004
    • /
    • 2000
  • The discharge processes in electro-negative gases with non-uniform field gape are composed of the formation of pulsed streamer corona, the transition of the streamers into leader step, the temporal development of the leader channel, and the stepped propagation of leader through the gap. In this paper, the first corona inception characteristics in $SF_6$ gas and $SF_{6}-N_{2}$ mixtures, related to the propagation of loader and the space charge effect, were experimentally investigated with positive and negative transient impulse voltages.

  • PDF

불평등전장에서 $SF_6/CO_2$ 혼합기체의 뇌임펄스 전구방전특성 (Characteristics of lightning impulse preliminary breakdown discharge under non-uniform electric field in $SF_6/CO_2$ mixtures)

  • 이복희;오성균;백영환;안창환;전덕규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2140-2142
    • /
    • 2005
  • This paper presents the experimental results on the preliminary breakdown characteristics under a highly non-uniform electric field in $SF_6/CO_2$ gas mixtures. The impulse preliminary breakdown developments are investigated by the measurements of corona current and light emission images. As a result, the preliminary breakdown development mechanisms for both positive and negative polarities are same. The first streamer corona is initiated at the tip of needle electrode, and the leaders develop with a stepwise propagation and bridge the test gap. The pause time of leader pulses in the positive polarity is significantly shorter than that in the negative polarity. Also, the time interval between the first streamer corona onset and breakdown in the negative polarity was much longer than that in the positive polarity The discharge channel paths in the positive polarity were zigzag. On the other hands, the leader channel in the negative polarity was thicker than that in the positive polarity.

  • PDF

이격거리가 큰 전국의 공기절연파괴 현상시 발생하는 인자측정에 관한 연구 (A Study on the Measurements of Discharge Parameters in Case of the Switching Impulse Breakdown of a Large Air Spacing)

  • 최영욱;조연옥
    • 대한전기학회논문지
    • /
    • 제40권12호
    • /
    • pp.1290-1295
    • /
    • 1991
  • The paper presents the measurement results on the parameters affecting the breakdown mechanism of a large air spacing under switching impulse voltages. Measured parameters are the velocities of leader channels, predischarge currents, electric charges injected into the rod-plane air gap and electric field intensities on the plane. For the 3m air gap under switching impulse voltages, the velocities of leader channel have been measured to be of 1cm/x10S0-6Ts - 5cm/x10S0-6Ts, electric field intensity of 2kv/cm, predischarge current of 1.2-1.6A, the charges injected into the air gap of 11-40x10S0-6TC for 400-887kV impulse voltages.

  • PDF

SF6/CO2혼합기체 중에서 뇌임펄스코로나방전의 특성 (Characteristics of lightning Impulse Corona Discharges in SF6/CO2 Mixtures)

  • 이복희;백영환;오성균;안창환
    • 조명전기설비학회논문지
    • /
    • 제20권1호
    • /
    • pp.85-90
    • /
    • 2006
  • 본 논문은 불평등 전계의 $SF_6/CO_2$혼합기체 중에서 전구방전특성에 대한 실험결과를 제시한다. 임펄스 전구방전 진전을 코로나 전류와 방전광 이미지의 측정으로 조사하였다. 정 부극성의 전구방전 진전메커니즘은 기본적으로 같았으며, 초기스트리머코로나는 침전극의 끝단에서 발단되어 계단상으로 진전하는 리더에 의해 시험갭을 교락시킨다. 정극성에서 리더펄스의 휴지시간은 부극성에서보다 매우 짧았다. 또한 부극성에서 초기스트리머코로나와 절연파괴사이의 시간간격은 정극성에서보다 매우 길게 나타났다. 정극성에서 방전채널경로는 임의적으로 나타났으며, 부극성에서 리더 채널은 정극성에서 보다 굵고 밝게 나타났다.

유황전극의 탄소량 변화에 따른 리튬/유황 전지의 방전특성 변화 (Effect of Carbon Content of Sulfur Electrode on the Electrochemical Properties of Lithium/Sulfur Battery Using PEO Electrolyte)

  • 강근영;류호석;김종선;김기원;안주현;이건환;안효준
    • 한국수소및신에너지학회논문집
    • /
    • 제17권3호
    • /
    • pp.317-323
    • /
    • 2006
  • Electric conductive material should be homogeneously mixed with sulfur in sulfur electrode fabrication of lithium/sulfur battery, because sulfur is electric insulator. In this paper electrochemical properties of Li/S battery was studied with various compositions of sulfur electrodes. When content of sulfur changed from 40 wt.% to 80 wt.%, the 60 wt.% sulfur electrode showed the maximum capacity of 1489 mAh/g-sulfur. Electrochemical properties of Li/S battery using 60 wt.% sulfur was also investigated with various carbon contents. The discharge capacity changed as a function of carbon contents. The optimum composition was 25 wt.% carbon for 60 wt.% sulfur electrode.

의학적 충고에 반한 퇴원의 특성과 퇴원결정 요인에 관한 연구 - 사회사업가의 개입사례와 역할을 중심으로 - (A Study on the Characteristics of DAMA(Discharge Against Medical Advice) Case and Causal Factors of DAMA - Perspective of Medical Social Worker's Role and Intervention -)

  • 강흥구;이상진;조경기
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권12호
    • /
    • pp.1620-1627
    • /
    • 2000
  • Objectives : DAMA cases were analyzed to examine what the main casual factors of DAMA were and how to deal with these cases effectively in hospital with the DAMA interdisciplinary team including medical social worker whose role is to perform psycho-social assessment, family counsel, to evaluate family's DAMA need. Patients and Methods : The content analysis of medical record and social work record were reviewed in 37 cases referred by medical doctor to DAMA team. These cases were reported by patients' self discharge request or family's request for discharge from September 1998 to February 2000. The DAMA team consists of Assistant Director of Hospital as team leader, medical staff in-charge, social worker, QI nurse, other staff members who are not involved in direct treatment for patient, and administrative clerk. Results : The results of content analysis are as follows : 1) The most causal factors of DAMA consist of combination of more than 2 factors. 2) The major decision-maker is revealed to be son and daughter of patient. 3) In 59.4% of cases, family was not informed of patients' prognosis, alternatives, the consequence of DAMA at all. 4) In cases of DAMA report, the rapid intervention of social worker is carried out. Conclusion : In this study, we propose the interdisciplinary team approach to make decision legitimately and ethically for DAMA. The suggestions from this study are as follows : 1) To deal with DAMA case properly, the interdisciplinary team approach should be considered. 2) The criteria for DAMA case should be formed carefully. For the explicit selection of DAMA case, preliminary system for high-risk patient screening is recommended. 3) The medical social worker is available for the psycho-social problems of the patient once family members. For the effective family counselling, discharge planning and nursing home placement, the participation of medical social worker should be mandatory.

  • PDF