• 제목/요약/키워드: law voltage

검색결과 212건 처리시간 0.024초

Estimation of Effective Coil Length of Superconducting Generator using 3D FEM

  • Shin, Pan-Seok;Park, Doh-Young
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제12B권1호
    • /
    • pp.7-12
    • /
    • 2002
  • This paper presents a method to estimate an effective length of a 1000-kVA superconducting generator using three-dimensional FE analysis. Flux linkage of stator coil and the induced voltage are calculated with FEM program and Faraday's law. An effective length of the stator coil is estimated using the calculated voltage and geometric configurationn of the machine. In order to verify the estimation method, 30-kVA superconducting generator is built and tested. The test result agrees reasonably well with the estimation.

유기 가스중 고주파 글로우가전 특성에 관한 연구 (The Study on Characteristics of High Frequency Glow Discharge in Organic Vapor)

  • 이덕출;김은배;박상현;박종대
    • 대한전기학회논문지
    • /
    • 제34권9호
    • /
    • pp.355-360
    • /
    • 1985
  • In this paper, the discharge phenomena of high frequency glow discharge in organic vapor are basically investigted to establish the growth mechanism and preparation technique for organic thin film. According to the increasing of discharge frequency, the discharge firing voltage(Vs) of organic vapor decreases. The dependence of discharge voltage(Vd) on gas pressure is generally in accord with Paschen's Law and Vd decreases as gas flow rate become larger, but increases as dischange current density become higher. And the values of Vd in organic vapor are generally higher than those of inorganic gas.

  • PDF

도시철도역사의 저압선로 및 기기에서의 지락사고 방지 방안에 관한 검토 (A Study on ground fault at low voltage line and apparatus in urban railway station)

  • 민경윤;김진호;한학수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.699-704
    • /
    • 2005
  • In the station of the railway and the subway various illumination equipment and a general power equipment for a passenger convenience, the signal equipment and the communication equipment which is necessary to the train operation provided. At the all of like this equipment from the electric room which is established in each station by changing from high voltage to low voltage and it supplies from the illumination transformer, the power transformer and the signal transformer. If it supplies to the equipment from the high voltage to the low voltage, it must be established to contact protection device in between the high voltage coil and the low voltage coil. Also it must do the grounding faulting device at the low voltage lines, the earthing devices at apparatus for the protection of an electric shock and an electric fire by the electric relation law. Compared the related regulations between the facilities which require protective functions such as grounding fault or earthing in public utilities like subway stations, and the facilities which do not require line earthing or protective functions such as electricity supplied for signalling the train. Also, will describe a countermeasure for the accident from a grounding fault.

  • PDF

에너지보존법칙을 이용한 전력계통 안정도 직접 해석법에서의 응용 (Direct Energy Method of Power System Stability Analysis and its Application by using Energy Conservation Law)

  • 이용훈;조병훈;류헌수;문영현
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권10호
    • /
    • pp.1207-1214
    • /
    • 1999
  • Many papers have recently been presented to develop energy functions for power systems. However, earlier studies adopted case-by-case approaches, which failed to give a general approach to deal with various kinds of generator models. In this paper, two useful theorems are developed regarding the integral relationships of the generator power versus its phasor current and voltage. By using the proposed theorems, an exact energy conservation law can be derived from the complex integral. The proposed energy conservation law, which is free of the generator model, can be utilized to develop energy functions for various kinds of generator models including the speed governors and exciters. An illustrative example is given for a multimachine system with the Eq' model of generator. This thesis also shows a possibility of more accurate and fast stability analysis by using the proposed Energy Conservation Law.

  • PDF

에너지 보존법칙과 전력계통 안정도 직접 해석법에서의 응용 (Energy Conservation Law and its application for Direct Energy method of Power System Stability)

  • 문영훈;이용훈;조병훈;류헌수;최병곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.263-268
    • /
    • 1998
  • Many papers have recently been presented to develop energy functions for power systems. However, earlier studies adopted case-by-case approaches, which failed to give a general approach to deal with various kinds of generator models. In this paper, two useful theorems are developed regarding the integral relationships of the generator power versus its phasor current and voltage. By using the proposed theorems, an exact energy conservation law can be derived from the complex integral. The proposed energy conservation law, which is free of the generator model, can be utilized to develop energy functions for various kinds of generator models including the speed governors, and exciters. An illustrative example is given for a multimachine system with the Eq' model of generator. This thesis also shows a possibility of more accurate and fast stability analysis by using the proposed Energy Conservation Law.

  • PDF

On the Voltage-Based Control of Robot Manipulators

  • Fateh, Mohammad Mehdi
    • International Journal of Control, Automation, and Systems
    • /
    • 제6권5호
    • /
    • pp.702-712
    • /
    • 2008
  • This paper presents a novel approach for controlling electrically driven robot manipulators based on voltage control. The voltage-based control is preferred comparing to torque-based control. This approach is robust in the presence of manipulator uncertainties since it is free of the manipulator model. The control law is very simple, fast response, efficient, robust, and can be used for high-speed tracking purposes. The feedback linearization is applied on the electrical equations of the dc motors to cancel the current terms which transfer all manipulator dynamics to the electrical circuit of motor. The control system is simulated for position control of the PUMA 560 robot driven by permanent magnet dc motors.

영전압 Regulation기능을 가진 BUCK 컨버터 (BUCK Converter with Zero Voltage Regulation Function)

  • 박점문;곽동걸;김은수;계문호;강유리;조기연;이현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.447-449
    • /
    • 1996
  • The main objective of this paper is to increase the efficiency, to eliminate the harmonics wave and to acomplish the zero voltage regulation of the output voltage. To accomplish the goal, DC-to-DC converter model with ERS(Energy Recovery Snubber) is developed. And, to realize the detail purpose, we are used ZVS soft switching snubber, ripple steering filter and, function control law etc.. So, we presented to show superior operation of this convertor with the zero voltage regulation function.

  • PDF

Adaptive Controller Design for a Synchronous Generator with Unknown Perturbation in Mechanical Power

  • Jiao Xiaohong;Sun Yuanzhang;Shen Tielong
    • International Journal of Control, Automation, and Systems
    • /
    • 제3권spc2호
    • /
    • pp.308-314
    • /
    • 2005
  • Transient stabilization with voltage regulation is investigated for a synchronous generator when the mechanical power is perturbed to any unknown value within its physical bounds so that the operating point of the system shifts to an unknown point. An adaptive excitation controller is designed based on the backstepping method with tuning functions. It will be shown that the adaptive control law proposed can achieve the convergence of the system states to the new equilibrium point in correspondence with the real value of the unknown mechanical power and the regulation of the terminal voltage to the required value. Simulation results are given to demonstrate the effectiveness of the proposed controller for the transient stabilization and voltage regulation.

단일채널 고온초전도 자속흐름 트랜지스터의 I-V 특성 비교분석 (A Comparative Analysis of I-V Characteristics in a single Channel Superconducting Flux Flow Transistor)

  • 고석철;강형곤;임성훈;최명호;이종화;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.107-110
    • /
    • 2003
  • We have proposed a model to describe the current-voltage characteristics of fabricated devices using the Biot-Savart's law in order to develop superconducting flux flow transistors, The measured and calculated values, including induced voltage, transresistance and current gain were investigated in relation to the parallel flow of the vortices in a single microbridge. The predictions agreed very well with measured results.

  • PDF

다채널 고온 초전도 볼텍스 유동 트랜지스터의 I-V 특성 해석 (Analysis of I-V Characteristics in the Multi-channel Superconducting Vortex Flow Transistor)

  • 고석철;강형곤;임성훈;최효상;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제16권10호
    • /
    • pp.931-937
    • /
    • 2003
  • The principle of the superconducting vortex flow transistor (SVFT) is based on control of the Abrikosov vortex flowing along a channel. The induced voltage is controlled by a bias current and a control current, instead of external magnetic field. The device is composed of parallel weak links with a nearby current control line. We explained the process to get an I-V characteristic equation and described the method to induce the external and internal magnetic field by the Biot-Savarts law in this paper. The equation can be used to predict the I-V curves for fabricated device. From the equation we demonstrated that the current-voltage characteristics were changed with input parameters. I-V characteristics were simulated to analyze a SVFT with multi-channel by a computer program.