• 제목/요약/키워드: laser particle counter

검색결과 26건 처리시간 0.018초

광학 입자 계수기의 응답특성 및 오계수에 관한 연구 (A Study of Response Characteristics and False Counts in Optical Particle Counter)

  • 안강호;이재헌
    • 대한기계학회논문집
    • /
    • 제16권3호
    • /
    • pp.547-554
    • /
    • 1992
  • 본 연구에서는 Climet사의 백색광원 OPC인 CI226와 PMS사의 laser 광원 OPC인 LAS-X 및 HS-LAS의 응답특성을 측정하여 제작사가 제시한 응답특성과 비교하여 그 정 확성을 논하였으며 아울러 고유량(high flow rate) Clean Room용 OPC인 Climet CI- 7300, Met One 200, Hiac/Royco5120 등 3가지 장치에 관한 오계수의 원인을 박히고자 하였다.

The BASF Laser Optical Pitch Particle Counter - Current Applications and Future Developments

  • Champ Simon;Hughes David;Lee Woo-Suk;Esser Anton;Kaub Hans Peter
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2006년도 PAN PACIFIC CONFERENCE vol.1
    • /
    • pp.73-78
    • /
    • 2006
  • The occurrence of detrimental substances in the paper machine leads to reduced economic performance of paper mills through reduced capacities due to increased paper breaks and cleaning times. In this article the latest generation of BASF's laser optical pitch particle counter is employed in the examination of a paper mill operating two paper machines and using a mixture of thermo-mechanical pulp and recycled fibres. The potential of the new instrument to differentiate between particles on the basis of size and chemical composition is discussed. In addition, direct evidence of the periodic and locational variation of detrimental substances in the paper machine is given. Finally, an example of the application of BASF's laser optical pitch particle counter in the selection of a suitable fixative system for a complex furnish is presented.

  • PDF

미세 입자 계수기를 위한 입자 검출 챔버 개발 (Development of Particle Detection Chamber for Particle Counter)

  • 엄우용
    • 전자공학회논문지
    • /
    • 제51권1호
    • /
    • pp.219-224
    • /
    • 2014
  • 본 논문에서는 미세 입자의 크기와 굴절률, 그리고 레이저 파장과 산란광을 얻는 수신단의 각도 등 여러 변수에 대하여 Mie 산란 이론을 적용하여 미세 입자의 산란 특성에 대하여 연구하였고, 이를 바탕으로 미세 입자 검출을 위한 광학계를 구성하고 산란 신호를 획득하여 그 특성을 분석하였다. 그리고 이러한 특성들을 바탕으로 미세 입자 검출기를 위한 입자 검출 챔버를 개발하고 성능을 분석한다.

Spatiotemporal behavior of excited Xe atoms density in Counter discharged type AC-PDP

  • Hong, Young-June;Oh, Phil-Yong;Jeong, Se-Hoon;Hong, Jong-Hwa;Kim, Jung-Hyun;Gyu, Yong;Cho, Seok-Ho;Hong, Sung-Hee;Hong, Byoung-Hee;Choi, Eun-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.574-577
    • /
    • 2007
  • We have measured the excited Xe atoms density in the $1s_5$ metastable states by laser absorption spectroscopy in counter discharged type AC-PDP. This experiment has shown the characteristic of the excited Xe atoms density which is relation to the visible light efficiency of PDP. The density of counter discharged AC-PDP have measured to be $9.47\;{\times}\;10^{13}\;cm{-3}$. The result has been shown to higher value than $1.45\;{\times}\;10^{13}\;cm^{-3}$ of conventional AC-PDP.

  • PDF

광학식 입자 계수기 내 샘플 노즐 직경이 측정 효율 및 특성에 미치는 영향에 대한 실험적 연구 (Experimental analysis on effects of nozzle diameter on detection characteristics of an optical particle counter)

  • 송현우;김태욱;송순호
    • 한국입자에어로졸학회지
    • /
    • 제13권4호
    • /
    • pp.159-164
    • /
    • 2017
  • The detection efficiency and characteristics of an optical particle counter (OPC), with various sample nozzle outlet diameters, were experimentally investigated. The OPC system, which was built with original design, was made up of a diode laser, two photodetectors, and a variety of optics such as a beam splitter and a concave mirror. The cone-shaped sampling nozzle was designed to be changeable to alter the outlet diameter, within the range of 1 to 3 mm. For samples, sets of polystyrene latex (PSL) standard particle with various sizes of 1 to $3{\mu}m$, were used. As a result, detection efficiency of the OPC greatly decreased with larger nozzle outlet diameter. Moreover, increased nozzle outlet diameter means broader sample flow, thus caused light interference and multiple scattering which results in abnormal high peaks in scattered light signal. The ratio of abnormal peaks to regular signal of single particle increased with larger nozzle outlet diameter.

Construction of a Dynamic Laser Light Scattering System Using a Personal Computer$^\dag$

  • Kim, Myung-Joong;Lee, Sang-Yong;Chung, Koo-Soon;Lee, Hoo-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • 제8권5호
    • /
    • pp.403-405
    • /
    • 1987
  • A dynamic laser light scattering system has been constructed using a personal computer. The intensity of the scattered light was detected with a photomultiplier tube and a photon counter. The BCD output of the photon counter which is proportional to the intensity of scattered light is fed into a personal computer via an interface card. The personal computer was programmed as an autocorrelator in machine language. The data acquisition rate of the system was about 600 samples/s which is adequate for studies on the molecular dynamics of concentrated polymer solutions, polymer latices with large particle size, and polymer glass systems. The constructed system was tested with polystyrene latex and the measured diameter of the latex particle agrees well with the supplier's value.

대기환경에서 광산란 미세먼지 측정기의 PM2.5 보정계수 산정 (Estimation of PM2.5 Correction Factor for Optical Particle Counter in Ambient Air)

  • 김종범;김단비;노수진;윤관훈;박덕신;이정주;김정호
    • 한국입자에어로졸학회지
    • /
    • 제16권2호
    • /
    • pp.49-59
    • /
    • 2020
  • Various devices have been developed to the measurement of particulate matter pollutants, and Optical Particle Counter (OPC) that can be easily and quickly measured is widely used lately. The measured value by OPC is converted to weight concentration using the correction factor (CF). The calculation of CF is very important to improve the reliability and accuracy of OPC. In this study, the CF calculation study of light scattering laser photometer (model 8533, TSI) was carried out to measure in the atmospheric environment using 2 gravimetric devices and 3 light scattering laser photometer devices. Regression analysis and Tukey tests were used to significance the test of measurement devices. Measurements were carried out twice. There was a comparative analysis of measurement data between light scattering laser photometer and gravimetric devices in 1st measurement, and then the Evaluation of PM2.5 concentration corrected by CF performed in 2nd measurement. As a result of the significance analysis between light scattering laser photometer and gravimetric devices, the correlation between the same method was high, but the correlation between different methods was low. CF was calculated as 0.4258 based on the measurement results, and it is a similar level to previous studies at home and abroad. It is expected that these results can be used as basic data in the future study for air quality measurement research using light scattering laser photometer. Also, in order to improve the accuracy of the measurement techniques and the development of technology in the atmospheric environment, CF calculation research should be conducted continuously.

Dynamic Light Scattering Method를 이용한 수중유형 Microemulsion의 제조조건 평가 (Process Evaluation in Preparing Oil in Water Microemulsion by Dynamic Light Scattering Method)

  • 민신홍;양중익;권종원;정대식;정엽
    • Journal of Pharmaceutical Investigation
    • /
    • 제17권1호
    • /
    • pp.41-46
    • /
    • 1987
  • Oil in water microemulsion containing soybean oil and egg phosphatide was prepared by vacuum high shear mixing and high pressure homogenizing. The laser particle sizer, Coulter counter and photomicroscope were used to determine the particle size distribution at each cycle of homogenizing. Particularly, the laser particle sizer(dynamic light scattering method) was applied to the study of particle size distribution behavior below $1\;{\mu}m$. It was found that the particle size distribution below $1\;{\mu}m$ was shifted to lower size range as the number of passing cycle was increased. Beyond the 7th cycle, however, the particle size distribution was not varied.

  • PDF

부산 도심지에서 측정된 에어로졸 농도의 물리적 특성 (Physical Characteristics of Aerosol Concentrations Observed in an Urban Area, Busan)

  • 김연종;김철희
    • 한국환경과학회지
    • /
    • 제19권3호
    • /
    • pp.331-342
    • /
    • 2010
  • Aerosol physical properties have been measured at Pusan National University by using the 16-channel LPC(Laser Particle Counter), and particle characteristics have been examined for the period from Aug. 4 2007 to Dec. 30, 2008. Annual total average, seasonal average, and other averages of the meteorologically classified four categories such as Asian dust, precipitation, foggy, and clear days are respectively described here. Both annually and seasonally averaged number concentration show three peaks at the particle diameter of 0.3, 1.3, and $4{\mu}m$, respectively. However, the first peak for summer season tends to be shifted toward smaller size than other seasons, implying the strong fine particle generation. Meteorological condition shows strong contrast in aerosol concentrations. In Asian dust case, relatively lower number concentrations of fine particles (i.e., smaller than $0.5{\mu}m$) were predominant, while higher concentrations of coarse particles were found particularly for the size bigger than $0.5{\mu}m$. In precipitation day, number concentrations were decreased by approximately 30% due to the removal process of precipitation. Foggy day shows significantly higher concentrations for fine particles, implying the importance of the aerosol condensation process of micro-fine-particle growing to fine-particle. Finally the regressed particle size distribution function was fitted optimally with two log-normal distribution, and discussed the similarities and differences among four categorized cases of the Asian dust, precipitation, foggy, and clear days.