• Title/Summary/Keyword: laser device

Search Result 824, Processing Time 0.027 seconds

Effects of Various Laser Wavelengths and Power Densities on the Ocular Damage in Pigmented Rats

  • Chung, Phil-Sang;Shin, Jang-In;Chang, Moo-Hwan;Chang, So-Young;Kang, Jung-Wook;Hwang, Hee-Jun;Ahn, Jin-Chul
    • Biomedical Science Letters
    • /
    • v.14 no.3
    • /
    • pp.173-178
    • /
    • 2008
  • With the widespread use of laser in medical and industrial settings, the incidence of laser injury to the ocular continues to grow among workers involved in handling lasers. The aim of this study is to compare ocular damages after irradiation with various laser wavelengths and power density. Ocular of pigmented rats was irradiated with $CO_2$ laser, 1064 nm Nd:YAG laser, and 532 nm diode laser. We observed damage of cornea, lens, and retina using slit lamp microscope and funduscopy. H&E staining of histopathology were applied to study the specimens. The higher exposure ($200mW/cm^2$, 10 sec) with $CO_2$ laser resulted in severe damage at the cornea. For the 1064 nm Nd:YAG laser, the higher exposure than $10mW/cm^2$ (10 sec) resulted in damage at the cornea and lens. Further, with the 532 nm diode laser, retinal lesions were induced when $10mW/cm^2$ (0.25 sec) was delivered to the eye. Theses results suggest that the ocular damages are different from various laser wavelength and power density.

  • PDF

Study of clean laser decapsulation process (친환경 레이저 디캡슐레이션에 관한 연구)

  • Hong, Yun-Seok;Mun, Seong-Uk;Nam, Gi-Jung;Choe, Ji-Hun;Yun, Myeon-Geun
    • Proceedings of the Korean Society of Laser Processing Conference
    • /
    • 2006.11a
    • /
    • pp.103-107
    • /
    • 2006
  • Decapsulation of EMC(Epoxy Molding Compound) in package device is a method used to inspect inside of device by removing plastic molding. So far, chemical etching and mechanical grinding methods have been used widely. Recently, several works using laser have been carried out. This method has advantages with fast process time and precision than conventional methods because of noncontact process. Also, laser process is a clean process because of removing EMC directly without using toxic chemicals. The wavelength of laser used in this study is 355nm. Key parameters of removing EMC are laser power, scan speed, and number of scans of laser. It if confirmed that laser decapsulation is a useful process to inspect inside a device with a small thermal damage to chip surface.

  • PDF

Visualization of Temperature Distribution Deep Inside the Agar Gel Tissue Phantom Heated Using Moxibustion and 1064 nm Infrared Laser (쑥뜸과 1064 nm 파장의 근적외선 레이저로 가열된 아가젤 조직 팬텀 심부의 온도분포 가시화)

  • Cho, Ji-Yong;Kim, Jung-Kyung
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.4
    • /
    • pp.54-59
    • /
    • 2010
  • A laser moxibustion therapy device having effect similar to that of traditional moxibustion is being developed using 1064 nm infrared laser. The therapy device allows direct interaction of laser light with the tissue rendering temperature distribution both on the skin surface and deep under the skin. We made a device that could measure temperature of deep under the surface of agar gel tissue phantom using thermocouples. A thermal imaging camera was used to verify results from the temperature measurement device. We compared the characteristics of heat transfer inside the tissue phantom during moxibustion and laser irradiation. The temperature distribution measured by thermocouples was found to be similar to that of distribution given by thermal imaging camera.

Fundamentals and Research Trend of Laser Acupuncture (레이저침의 원리와 연구동향 분석)

  • Kim, Hyun-Ho;Nam, Dong-Woo;Lee, Sang-Hoon
    • Journal of Acupuncture Research
    • /
    • v.26 no.6
    • /
    • pp.21-30
    • /
    • 2009
  • Objectives : Being introduced in the 1980s, laser acupuncture studies have been steadily carried on such as its thermal effects on human body. However, the mechanisms of effect are not yet clearly explained. Generally, laser acupuncture could be favorable for pediatric patients or people under special conditions (hemophilia, needle-phobia, pathogen-carriers, etc.) because of lower risk of infection, bleeding, pain or fainting. But there are still problems for using laser acupuncture equivalently as the traditional metal needle. The goal of this study is to review the fundamentals, history and present trend of laser acupuncture study, and to suggest how to develop laser acupuncture as an oriental medical device. Method : We performed literature search using PubMed(http://www.ncbi.nlm.nih.gov/pubmed) and Scopus(http://www.scopus.com). Search conditions are laser acupuncture, laser needle, LLLT(as title or abstract) or Litscher G(as author). Main target studies are physical fundamentals, clinical trials, physiological results and device proposals. Results : Many research have shown the similarities of laser acupuncture and traditional metal acupuncture and have reported clinical and physiological effects of laser acupuncture. But, still laser acupuncture is not widely used in Korea due to high-cost of equipments and the lack of clear understanding of laser devices. Additionally, there are still challenges in standardization and device development. Conclusions : Frequencies, laser modes, waveguides, adaptor types, polarization and signal modulations are suggested as future study subjects on laser acupuncture. More various studies and efforts for device development have to be performed to provide oriental medical doctors with evidence based confidence about usage of laser acupuncture.

  • PDF

Histologic Evaluation of Collagen Generation in Mouse Subcutaneous Tissue Using 880 nm & 630 nm LED

  • Ahn, Jin-Chul;Chung, Phil-Sang;Chang, So-Young;Hwang, Hee-Jun;Shin, Jang-In;Rhee, Chung-Ku
    • Biomedical Science Letters
    • /
    • v.14 no.3
    • /
    • pp.167-172
    • /
    • 2008
  • We compared the clinical efficacy of LED therapy using 880 nm and 630 nm LED to test collagen accumulations in subcutaneous tissue of mouse after LED irradiation by measuring the quantity of collagen. 880 nm and 630 nm LED was irradiated on the back of ICR mouse given at $10.8J/cm^2$ followed for 30 minutes everyday for 5 weeks. Histological observation was performed by Hematoxylin & Eosin staining and Masson's Trichrome collagen staining. We also used Sircol soluble collagen assay kit for measuring the amounts of collagen in the mouse skin tissue after 1, 3, and 5 weeks post LED irradiation, respectively. Collagen generation was found at subcutaneous tissue, and the quantity of collagen in 880 nm LED group had grown more than that of 630 nm LED group at 5 weeks follow-up later. About 75% more efficacies for collagen generation were found in the group of 5th week of 880nm LED irradiation. The efficacy of 880nm LED could be more useful than 630 nm LED for synthesizing collagens in mouse subcutaneous tissue as time followed.

  • PDF

Histological Change and Collagen Formation on Laser Wounded Rat using 808 nm Diode Laser and $CO_2$ Laser

  • Chung, Phil-Sang;Shin, Jang-In;Chang, So-Young;Ahn, Jin-Chul
    • Biomedical Science Letters
    • /
    • v.15 no.1
    • /
    • pp.81-86
    • /
    • 2009
  • Lasers are necessity in our life related to the fields of medicine and cosmetic surgery. With 808 nm diode laser and $CO_2$ laser, we made some wounds on a dorsum of rat by laser irradiation. All of irradiations shows thermal effects on the whole region of skin tissues. They make wound damage depending on laser power and irradiation time. Because a collagen is plays an important role in tissue repair, we studied collagen accumulation in wound tissue. For wound healing, collagen accumulation was found in the near region of damage in epidermis and dermis layer of the rat skin. In case of the quantitative analysis of collagen in wound tissue, the amount of collagen in wound tissue by $CO_2$ laser irradiation is higher than that of 808 nm diode laser irradiation. And re-epithelialization was significantly faster in wound by $CO_2$ laser irradiation compared with that of 808 nm diode laser irradiation.

  • PDF

Study on Memristive Characteristics in Electronic Devices Based on Vanadium Dioxide Thin Films Using 966nm Laser Pulses (966nm 레이저 펄스를 이용한 바나듐 이산화물 박막 기반 전자 소자에서의 멤리스터 특성에 관한 연구)

  • Kim, Jihoon;Lee, Yong Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.59-65
    • /
    • 2015
  • By harnessing the thermal hysteresis behavior of vanadium dioxide($VO_2$), we demonstrated multi-resistance states in a two-terminal electronic device based on a $VO_2$ thin film by using a 966nm infrared laser diode as an excitation light source for resistance modulation. Before stimulating the device using 966nm laser pulses, the thermal hysteresis behavior of the device resistance was measured by using a temperature chamber. After that, the $VO_2$ device was thermally biased at ${\sim}71.6^{\circ}C$ so that its temperature fell into the thermal hysteresis region of the device resistance. Six multi-states of the device resistance could be obtained in the fabricated $VO_2$ device by five successive laser pulses with equal 10ms duration and increasing power. Each resistance states were maintained while the temperature bias was applied. And, the resistance fluctuation level was within 2.2% of the stabilized resistance and decreased down to less than 0.9% of the stabilized resistance 5s after the illumination.

Barrier Layers and Pulsed Laser Annealing Effects on TFEL Device with Cu and Ag co-doped SrS blue Phosphor Layer

  • Nam, Tae-Sung;Liew, Shan-Chun;Koutsogeorgis, Demosthenes C;Cranton, Wayne M
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.910-913
    • /
    • 2003
  • In order to enhance performance, stability, and brightness of inorganic blue-light emitting EL device, barrier layer structure and pulsed laser annealing(PLA) treatment were introduced. The barrier layer structure was utilized for improving brightness of the device and instead of thermal annealing, pulsed laser annealing process was used. From this study, optimum barrier layer thickness and number of pulsed laser irradiation are established.

  • PDF

Development of Laser Diode Test Device using Feedback Control with Machine Vision (비젼 피드백 제어를 이용한 광통신 Laser Diode Test Device 개발)

  • 유철우;송문상;김재희;박상민;유범상
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1663-1667
    • /
    • 2003
  • This thesis is on tile development of LD(Laser Diode) chip tester and the control system based on graphical programming language(LabVIEW) to control the equipment. The LD chip tester is used to test the optic power and the optic spectrum of the LD Chip. The emitter size of LD chip and the diameter of the receiver(optic fiber) are very small. Therefore, in order to test each chip precisely, this tester needs high accuracy. However each motion part of the tester could not accomplish hish accuracy due to the limit of the mechanical performance. Hence. an image processing with machine vision was carried out in order to compensate for the error. and also a load test was carried out so as to reduce tile impact of load on chip while the probing motion device is working. The obtained results were within ${\pm}$5$\mu\textrm{m}$ error.

  • PDF

A Study on Safety, Performance and Clinical effectiveness Test Guideline of Versatile Ophthalmic Laser System (다목적 안과용 레이저 시스템 안전성 성능평가 및 임상적 유효성평가 가이드라인 수립을 위한 연구)

  • Kim, You Rim;Yu, Woo Jin;Park, Ho Joon;Jang, Won Seuk
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.250-259
    • /
    • 2019
  • Ophthalmic Laser System is widely used in Selective Laser Trabeculoplasty of Open Angle Glaucoma and Ocular Hypertension. Versatile ophthalmic laser system is a medical device with technology that checks the condition of the treatment area by irradiating a continuous laser pulse on the treatment area, and monitoring the microbubble reaction caused by the temperature increase of the melanosome through the ultrasonic signal and the optical signal sensor. It performs selective laser treatment without damaging the photoreceptor by controlling the wavelength of the laser when microbubbles are detected. This study aims to suggest a guideline for evaluating safety, performance and clinical effectiveness of Versatile Ophthalmic Laser System in accordance with the growing technology. International Standards, Regulations, and Clinical Trial Protocols were investigated and analyzed for this study. As a result of this study, the safety, performance and clinical effectiveness test guideline for Versatile Ophthalmic Laser System were proposed. This guideline will ensure the safety and efficacy of Medical device, and furthermore it is expected to be able to promote the development of technology development by supporting a clinical trial plan.