• Title/Summary/Keyword: large source

Search Result 2,518, Processing Time 0.027 seconds

Schottky barrier polycrystalline silicon thin film transistor by using platinum-silicided source and drain (플레티늄-실리사이드를 이용한 쇼트키 장벽 다결정 박막 트랜지스터트랜지스터)

  • Shin, Jin-Wook;Choi, Chel-Jong;Chung, Hong-Bay;Jung, Jong-Wan;Cho, Won-Ju
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.80-81
    • /
    • 2008
  • Schottky barrier thin film transistors (SB-TFT) on polycrystalline silicon(poly-Si) are fabricated by platinum silicided source/drain for p-type SB-TFT. High quality poly-Si film were obtained by crystallizing the amorphous Si film with excimer laser annealing (ELA) or solid phase crystallization (SPC) method. The fabricated poly-Si SB-TFTs showed low leakage current level and a large on/off current ratio larger than $10^5$. Significant improvement of electrical characteristics were obtained by the additional forming gas annealing in 2% $H_2/N_2$ ambient, which is attributed to the termination of dangling bond at the poly-Si grain boundaries as well as the reduction of interface trap states at gate oxide/poly-Si channel.

  • PDF

OBSERVATIONAL TEST STUDY OF TRAO OUTER GALAXY SURVEY COMPARING TO FCRAO OUTER GALAXY SURVEY (대덕전파천문대와 FCRAO의 외은하탐사 비교관측연구)

  • Lee, Y.;Jung, J.H.;Kang, H.W.;Lee, C.H.;Kim, H.G.;Kim, I.S;Kim, B.G.
    • Publications of The Korean Astronomical Society
    • /
    • v.25 no.1
    • /
    • pp.23-28
    • /
    • 2010
  • We present results of a test-study of the large-scale survey using the multi-beam receiver system recently installed on the 14 m telescope at Taeduk Radio Astronomy Observatory (TRAO). We have tested several modes of mapping, and found suitable (time-saving) mapping parameters of 'ON-SOURCE' = 8, 'OFF-SOURCE' = 1 when using 'RPT' = 3 as a position-switching mode. We observed 504 spectra towards the NGC 7538, a star forming molecular cloud in the transition of J = 1 - 0 of $^{12}CO$. From the Outer Galaxy Survey database (Heyer et al., 1998) we obtained 504 spectra for the same region. We compared integrated intensities, line profiles of two databases, and found that they are consistent to each other. From the intensity ratio of these two databases we also found that the value of forward spillover scattering of the TRAO telescope system is 0.58.

Synthesis of Multi-Walled Carbon Nanotubes and Nanofibers on a Catalytic Metal Substrate Using an Ethylene Inverse Diffusion Flame as a Heat Source (에틸렌 역확산화염을 열원으로 사용하여 촉매금속 기판 상에 합성한 탄소나노튜브와 탄소나노섬유)

  • Lee, Gyo-Woo;Jurng, Jong-Soo;Kang, Kyung-Tae;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.9
    • /
    • pp.1081-1092
    • /
    • 2004
  • The synthesis of Ni-catalyzed multi-walled carbon nanotubes and nanofibers on a catalytic metal substrate, using an ethylene fueled inverse diffusion flame as a heat source, was investigated. When the gas temperature was varied from 1,400K to 900K, approximately, carbon nanotubes with diameters of 20∼60nm were formed on the substrate. In the regions where the gas temperature was higher than 1,400K or lower than 900K, iron nanorods or carbon nanofibers were synthesized, respectively. Based on the quantitative analyses of large amount of SEM and TEM images, the nanotubes formed closer to the flame had a tendency of having larger diameters. HR-TEM images and Raman spectra revealed that carbon nanotubes synthesized had multi-walled structures with some defective graphite layers at the wall. Based on the graphite mode of the Raman spectra, it was believed that the optimal synthesis could be obtained as the substrate was positioned at between 5.5mm and 5.0mm, from the flame axis.

Turbulence-induced noise of a submerged cylinder using a permeable FW-H method

  • Choi, Woen-Sug;Choi, Yoseb;Hong, Suk-Yoon;Song, Jee-Hun;Kwon, Hyun-Wung;Jung, Chul-Min
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.8 no.3
    • /
    • pp.235-242
    • /
    • 2016
  • Among underwater noise sources around submerged bodies, turbulence-induced noise has not been well investigated because of the difficulty of predicting it. In computational aeroacoustics, a number of studies has been conducted using the Ffowcs Williamse-Hawkings (FW-H) acoustic analogy without consideration of quadrupole source term due to the unacceptable calculation cost. In this paper, turbulence-induced noise is predicted, including that due to quadrupole sources, using a large eddy simulation (LES) turbulence model and a developed formulation of permeable FW-H method with an open source computational fluid dynamics (CFD) tool-kit. Noise around a circular cylinder is examined and the results of using the acoustic analogy method with and without quadrupole noise are compared, i.e. the FW-H method without quadrupole noise versus the permeable FW-H method that includes quadrupole sources. The usability of the permeable FW-H method for the prediction of turbulence-noise around submerged bodies is shown.

EA Study on the Operation Performance of Central Plant Equipment According to Part Load Characteristics (부분부하 특성을 고려한 열원기기의 운전성능 평가)

  • Lee, Wang-Je;Kang, Eun-Chul;Lee, Euy-Joon;Oh, Byung-Chil;Shin, U-Cheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.7
    • /
    • pp.392-397
    • /
    • 2013
  • To fulfill the demands concerning energy efficiency for zero energy buildings, various technologies of architects and engineers are required. This study aims to estimate the thermal performance of heat source equipment in which part load characteristics are considered in an office building. Overestimation of heat source equipment was reviewed through literature survey, and heating and cooling loads depending on the capacity and division of the equipment were analyzed through a simulation program (DOE-2.1E). The conclusions gained from this study are as follows; 1) The more the division of equipment, the less the heating and cooling energy consumption. 2) When a large item of equipment is divided into two small items of equipment, the optimum application rate showed as 5:5 for chiller, and 7:3 for boiler, respectively.

A Hydroelastic Response Analysis of Barge Type Ships in Regular Waves (규칙파중의 바지형 선박의 유탄성응답해석)

  • Lee, Seung-Chul;Goo, Ja-Sam;Ha, Young-Rok;Doh, Daeog-Hee
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.2
    • /
    • pp.34-40
    • /
    • 2010
  • When a large ship is advancing in waves, it undergoes hydroelastic response, which affects the structural stability and the fatigue destruction of the ship. Therefore, to predict an accurate hydroelastic response, it is necessary to conduct a thorough analysis of hydroelastic response, including fluid-structure interactions. In this research, the ship is divided into many hull elements, to calculate the fluid forces and wave exciting forces on each element. Using the three-dimensional source distribution method, the calculated fluid forces and wave exciting forces are assigned to nodes of the hull elements. The neighbor nodes are connected with elastic beam elements. We analyzed hydroelastic responses, using the finite elements method.

Measurement and Analysis of Risk Voltages by Various Current Sources in Grounding System (다양한 전류원에 대한 접지시스템의 위험전압 측정과 분석)

  • Kil, Gyung-Suk;Moon, Byoung-Doo;Kim, Hwang-Kuk;Park, Dae-Won;Gil, Hyoung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.113-118
    • /
    • 2009
  • Grounding systems set the reference voltage level of electric circuits and suppress the Ground Potential Rise (GPR) by flowing fault currents to the ground safely. There are several parameters which evaluate the performance of grounding systems as ground resistance, touch voltage and step voltage. The touch and step voltages, which is called "risk voltage", are especially important to ensure the safety of human body. This paper dealt with the influence of current sources with the different frequency components on the touch and the step voltages. Three types of current sources as commercial frequency, square wave, and surge with the fast risetime of $50\;ns{\sim}500\;ns$ were used to analyze the risk voltages in a grounding system. The risk voltages showed remarkable difference in the same current amplitude depending on the current sources, and increased linearly with the current amplitude in the same current source. From the experimental results, it was confirmed that the risk voltages can be evaluated by a small current application in large-scale grounding systems and the possible largest risk voltage can be calculated by a surge current with the risetime of 200 ns or a current source with the same frequency component as the surge current.

A Study on the Effect of Resonant Coil Size and Load Resistance on the Transmission Efficiency of Magnetic Resonance Wireless Power Transfer System (공진 코일의 크기와 부하 저항이 자계 공명 무선 전력 전송 장치의 전달 효율에 주는 영향에 관한 연구)

  • Park, Jeong-Heum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.45-51
    • /
    • 2012
  • In this paper, the wireless power transfer system using the magnetic resonance was designed and the effect of resonant coil radius and load resistance to this system was analyzed by the circuit analysis method. As a result, the calculated transmitted-power is similar to measured one, and the coil size has a small effect to the coupling coefficients in the resonant frequency band. In addition, the fact that the calculated transmitted-power according to the source frequency is similar to measured one confirms that the circuit analysis methode in this paper is valid. The input side transmission efficiency ${\eta}_i$ including only the loss in the power transfer circuit is almost 90[%] with the large coil in the 10[cm] transfer distance, and 65[%] with the small coil in 1[cm]. The source side transmission efficiency ${\eta}_s$ is 30~40[%] at both coil when load resistance below 4.7[${\Omega}$] has been connected. Considering that the maximum ${\eta}_s$ is 50[%], this is valid in the practical applications.

Development of Evaluation Index for Foreign Weapon System Purchase using DEMATEL and ANP (DEMATEL과 ANP를 이용한 해외구매 무기체계의 평가지표 개발)

  • Cho, Hyun-Ki;Kim, Woo-Je
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.37 no.2
    • /
    • pp.73-88
    • /
    • 2012
  • Even though the final source selection of foreign weapon system purchase project in defense area is the most important phase, the standard evaluation index has not been developed. This paper provides an appropriate evaluation index using DEMATEL and ANP methods. First, the all possible evaluation criteria applied to the relevant previous literatures in domestic and overseas researches are derived and classified into groups. Second, DEMATEL method is used to determine the network structure representing the relations of cause and effect between groups and their sub-criteria. If isolated factors, not connected with other factors, are existed in the network structure, all factors except for the isolated ones are grouped as one large factor so that the independency between those ones is maintained. The weights of criteria are determined using AHP method if the criteria are independent relation and ANP method if the criteria are networked. The weights of higher and lower level criteria are then integrated and distributed as a point with respect to the decision making purpose. The developed evaluation index can be used as a standard one in various foreign weapon system purchase projects in defense area.

The accuracy of analyzing reverberation time (잔향 시간 분석의 정확도)

  • Kang, Seong-Hoon;Jung, Han-Kyo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.5
    • /
    • pp.349-355
    • /
    • 2018
  • A large number of parameters have been defined in order to describe and to evaluate the acoustical propeTies in rooms. Reverberation time is an impoTant characteristic of conceT halls, theaters and studios, etc. Over the years, a number of different methods for measuring the reverberation time have been developed, the most common being: the interrupted noise method, the integrated impulse response method, and the method of recording the room response to an impulsive source. However, the reverberation time can be changed by the measurement method, sound source and microphone. Therefore, it is difficult to accurately measure the reverberation time in a room. In this paper, it will be analyzed the interpretation method of the reverberation time and discussed the limitations.