• Title/Summary/Keyword: large area x-ray detector

Search Result 27, Processing Time 0.031 seconds

The High Voltage Research of X-ray Detector Based on Amorphous Selenium (a-Se 기반의 X선 검출기에서의 고전장 간섭 연구)

  • Cha, Byung-Youl;Kang, Sang-Sik;Cho, Sung-Ho;Lee, Gyu-Hong;Kim, Jae-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.853-856
    • /
    • 2002
  • Present. direct method x-ray conversion detector is studied by abroad medical instrument and country with amorphous Selenium. And we search the method for large area x-ray detector. Amorphous-Selenium based photoreceptor is widely used on the X-ray conversion materials. But amorphous-selenium based x-ray conversion detector is broken by high voltage and leakage defect point. In this paper, We investigated top-electrode distance rate to improve defect point and high voltage broken. The result to appoint to made large area x-ray conversion detector with base data.

  • PDF

Digital Tomosynthesis using a Flat-panel Detector based Micro-CT

  • Mandai, Koushik Kanti;Choi, Jeong-Min;Cho, Min-Hyoung;Lee, Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.5
    • /
    • pp.364-370
    • /
    • 2008
  • Recent development in large area flat-panel x-ray detector technology enables clinical application of digital tomosyntesis. Unlike conventional motion tomography using x-ray films, flat-panel x-ray detectors provide projection images in digital formats so that tomographic images can be synthesized in a more flexible way. For the digital tomosynthesis, precise movements of the x-ray source and the x-ray detector with respect to a fulcrum point are necessary. In this study, we apply the digital tomosynthesis technique to the flat-panel detector based micro-CT in which the flat-panel detector and the x-ray source rotate together on a circular arc. The experimental results suggest that flat-panel detector based 3D CTs can be used for digital tomosynthesis in the clinical environment.

Seperate Driving System For Large Area X-ray Detector In Radiology (대면적 X-ray 검출기를 위한 분할 구동 시스템)

  • Lee, D.G.;Park, J.K.;Kim, D.H.;Nam, S.H.;Ahn, S.H.;Park, H.D.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.388-391
    • /
    • 2003
  • The properties of these detectors can be controlled by electronics and exposure conditions. Flat-panel detectors for digital diagnostic imaging convert incident x-ray images to charge images. Flat panel detectors gain more interest real time medical x-ray imaging. Active area of flat panel detector is $14{\times}17$ inch. Detector is based on a $2560{\times}3072$ away of photoconductor and TFT pixels. X-ray conversion layer is deposited upper TFT array flat panel with a 500m by thermal deposition technology. Thickness uniformity of this layer is made of thickness control technology(5%) of thermal deposition system. Each $139m{\times}139m$ pixel is made of thin film transistor technology, a storage capacitor and charge collection electrode having geometrical fill factor of 86%. Using the separate driving system of two dimensional mosaic modules for large area, that is able to 4.2 second per frame. Imaging performance is suited for digital radiography imaging substitute by conventional radiography film system..

  • PDF

The characteristic study of hybrid X-ray detector using ZnS:Ag phosphor (ZnS:Ag phosphor를 이용한 hybrid 형 X-ray detector 특성 연구)

  • Park, Ji-Koon;Gang, Sang-Sik;Lee, Dong-Gil;Cha, Byeong-Yeol;Nam, Sang-Hee;Choi, Heung-Kook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.27-30
    • /
    • 2002
  • Photoconductor for direct detection flat-panel imager present a great materials challenge, since their requirements include high X -ray absorption, ionization and charge collection, low leakage current and large area deposition. Selenium is practical material. But it needs high thickness and high voltage in selenium for high ionization rate. We report comparative studies of detector sensitivity. One is an a-Se with $70{\mu}m$ thickness on glass. The other has hybrid layer of depositting ZnS phosphor with $100{\mu}m$ on a-Se. The leakage current of hybrid is similar to it of a-Se, but photocurrent is lager than a-Se. Both of them have high spatial resolution, but hybrid has higher sensitivity than a-Se at comparable bias voltage.

  • PDF

The Comparison of X-ray Response Characteristics of Vacuum Evaporated (진공증착된 CdTe와 $Cd_{0.85}Zn_{0.15}Te$ 필름의 X선 반응특성 비교)

  • Kang, S.S.;Choi, J.Y.;Cha, B.Y.;Moon, C.W.;Kim, J.H.;Nam, S.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.845-848
    • /
    • 2002
  • The study of photoconductor materials is demanded for development for flat-panel digital x-ray Imager. In this paper, We investigated the feasibility of application as x-ray image sensor using Cd(Zn)Te compound with high stopping power on high radiation. These Cd(Zn)Te samples were fabricated by vacuum thermal evaporation method to large area deposition and investigated I-V measurement as applied voltage. The experimental results show that the additional injection Zn in CdTe film reduced the leakage current, for the $Cd_{0.85}Zn_{0.15}Te$ detector, the net charge had the highest value as $144.58pC/cm^2$ at 30 V.

  • PDF

Optical Monte Carlo Simulation on Spatial Resolution of Phosphor Coupled X-ray Imaging Detector (형광체 결합형 X선 영상검출기의 공간 해상력 몬테카를로 시뮬레이션)

  • Kang, Sang-Sik;Kim, So-Yeong;Shin, Jung-Wook;Heo, Sung-Wook;Kim, Jae-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.328-328
    • /
    • 2007
  • Large area matrix-addressed image detectors are a recent technology for x-ray imaging with medical diagnostic and other applications. The imaging properties of x-ray pixel detectors depend on the quantum efficiency of x-rays, the generated signal of each x-ray photon and the distribution of the generated signal between pixels. In a phosphor coated detector the light signal is generated by electrons captured in the phosphor screen. In our study we simulated the lateral spread distributions for phosphor coupled detector by Monte Carlo simulations. Most simulations of such detectors simplify the setup by only taking the conversion layer into account neglecting behind. The Monte Carlo code MCNPX has been used to simulate the complete interaction and subsequent charge transport of x-ray radiation. This has allowed the analysis of charge sharing between pixel elements as an important limited factor of digital x-ray imaging system. The parameters are determined by lateral distribution of x-ray photons and x-ray induced electrons. The primary purpose of this study was to develop a design tool for the evaluation of geometry factor in the phosphor coupled optical imaging detector. In order to evaluate the spatial resolution for different phosphor material, phosphor geometry we have developed a simulation code. The developed code calculates the energy absorption and spatial distribution based on both the signal from the scintillating layer and the signal from direct detection of x-ray in the detector. We show that internal scattering contributes to the so-called spatial resolution drop of the image detector. Results from the simulation of spatial distribution in a phosphor pixel detector are presented. The spatial resolution can be increased by optimizing pixel size and phosphor thickness.

  • PDF

I-V Measurements of large area $HgI_2$ X-ray detector produced by PIB method (PIB법을 이용한 대면적 $HgI_2$ 검출기의 I-V 특성평가)

  • Kim, Kyung-Jin;Park, Ji-Koon;Kang, Sang-Sik;Cha, Byung-Youl;Cho, Sung-Ho;Sin, Jeong-Uk;Mun, Chi-Ung;Nam, Sang-Hee;Kim, Jin-Yung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.254-255
    • /
    • 2005
  • In this paper, we investigated electrical characteristics of the X-ray detector of mercuric iodide (HgI2) film fabricated by PIB(Particle-in-Binder) Method on ITO substrates 17cm$\times$20cm in size with thicknesses ranging from approximately 200${\mu}m$ to 240${\mu}m$. In the present study, using I-V measurements, their electrical properties such as leakage current, X-ray sensitivity, and signal-to-noise ratio (SNR),were investigated. The results of our study can be useful in the future design and optimization of direct active-matrix flat-panel detectors (AMFPD) for various digital X-ray imaging modalities.

  • PDF

X-ray properties measurement of Flat panel Digital X-ray gas detector (평판형 디지털 엑스레이 가스 검출기의 엑스선 특성 측정기술에 관한 연구)

  • Yoon, Min-Seok;Cho, Sung-Ho;Oh, Kyung-Min;Jung, Suk-Hee;Nam, Sang-Hee;Park, Ji-Goon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.17-21
    • /
    • 2009
  • The Recently, large area matrix-addressed image detectors are investigated for X-ray imaging with medical diagnostic and other applications. In this paper, a new flat panel gas detector for diagnostic X-ray imaging is proposed, and its characteristics are investigated. The research of flat panel gas detector is not exist at all. Because of difficulty to inject gas against to atmospheric pressure. So almost gas detector made by chamber shape. We made flat panel sample by display technique. (ex: PDP, Fed, etc.) The experimental measurements, the transparent electrodes, dielectric layer, and the MgO protection layer were formed in front glass. And, the X-ray phosphor layer and address electrodes are formed in the rare glass. The dark current, the x-ray sensitivity and linearity as a function of electric field were measured to investigate the electrical properties. From the results, the stabilized dark current density and the significant x-ray sensitivity were obtained. And the good linearity as a function of exposure dose was showed in wide diagnostic energy range. These results means that the passive matrix-addressed flat panel gas detector can be used for digital x-ray imaging.

  • PDF

입자침전법을 이용한 광도전체 필름의 X선 반응 특성에 관한 연구

  • Choe, Chi-Won;Gang, Sang-Sik;Jo, Seong-Ho;Gwon, Cheol;Nam, Sang-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.176-176
    • /
    • 2007
  • Flat-panel direct conversion detectors used in compound substance of semiconductor are being studied for digital x-ray imaging. Recently, such detectors are deposited by physical vapor deposition(PVD) generally. But, most of materials (HgI2, PbI2, TlBr, PbO) deposited by PVD have shown difficult fabrication and instability for large area x-ray imaging. Consequently, in this paper, we propose applicable potentialities for screen printing method that is coated on a substrate easily. It is compared to electrical properties among semiconductors such as $HgI_2$, $PbI_2$, PbO, HgBrI, InI, and $TlPbI_3$ under investigation for direct conversion detectors. Each film detector consists of an ~25 to $35\;{\mu}m$ thick layer of semiconductor and was coated onto the substrate. Substrates of $2cm{\times}2cm$ have been used to evaluate performance of semiconductor radiation detectors. Dark current, sensitivity and physics properties were measured. Leakage current of $HgI_2$ as low as $9pA/mm^2$ at the operation bias voltage of ${\sim}1V/{\mu}m$ was observed. Such a value is not better than PVD process, but it is easy to be fabricated in high quality for large area x-ray Imaging. Our future efforts will concentrate on optimization of growth of film thickness that is coated onto a-Si TFT array.

  • PDF

Study for X-ray detector using liquid crystal modulator (Liquid crystal modulator를 이용한 엑스선 검출기에 관한 연구)

  • Heo, Seung-Uk;Cho, Sung-Ho;Kim, Yoon-Seok;Kim, Young-Bin;Nam, Sang-Hee;Park, Ji-Goon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.5-9
    • /
    • 2009
  • The trend of Digital x-ray Detector research is to improve resolution of image and to embody large area imaging as well as dynamic moving imaging, etc. This research is divided with indirect conversion method and direct conversion method by radiation conversion process. Each conversion method has problems such as decrease of resolution from light scattering in indirect method case and not only low system stability but also difficult in dynamic moving imaging in direct method case. X-ray detector using liquid crystal has been researching to solve these problems, but it is difficulty in uniform injection of liquid crystal because of its structural properties. Therefore, this study suggests the structure which solves present problem. Also the possibility of suggested structure was investigated using simulation.

  • PDF