• 제목/요약/키워드: laid

검색결과 1,175건 처리시간 0.022초

OCHP를 이용한 매스콘크리트 수화열 분산효과에 관한 실험적 연구 (An Experimental Study on the Dispersion Effect of Hydration Heat in the Mass Concrete Using OCHP)

  • 김명식;백동일;김강민;염치선;배원만
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.437-440
    • /
    • 2006
  • In process of the mass concrete structure, the heat of hydration may cause serious thermal cracking. In order to eliminate hydration heat of mass concrete, this paper results of hydration heat control of mass concrete using the Oscillating Capillary tube Heat Pipe(OCHP). There were the several molds which shows a difference as compared with each other. One was not equipped with OCHP. Other were laid with OCHP, and the other were laid in 100cm, and exposed out 50cm. All of them were cooled with natural air convection. The OCHP was composed of copper pipe(outer diameter : 4mm, inner diameter : 2.8mm) and heat type was non-looped type. The working fluid was R-22 and its charging ratio was 40% by volume. The core of the concrete temperature was approximately $53^{\circ}C$ without OCHP. But the concrete temperature with OCHP was reduced its difference in temperature with the outdoor temperature to $12{\sim}15^{\circ}C$. Finally we saw the index figure of the thermal crack of the structures were varied from 0.6 to 1.6.

  • PDF

현장측정을 통한 노후 레일의 피로수명 평가에 관한 연구 (A Study on Estimation of Fatigue Life of Aged Continuous Welded Rail using the Field Test)

  • 공선용;성덕룡;김준형;박용걸
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.352-364
    • /
    • 2007
  • It is essential to reduce track maintenance costs and to extend the periodic replacements of continuous welded rails based on accumulated passing tonnage. As recently train load decrease and rail joints wear down less, the periodic replacements of continuous welded rails can be extended. There are many kinds of rail damage like squat, head-check and corrugation. These can be taken nondestructive or naked eye test. So the periodic replacements of continuous welded rails based on accumulated passing tonnage were examine with focusing on a crack of rail bottom of continuous welded rail. Therefore, this study measure dynamic response of track by metro train load, it compute impact coefficient and track spring coefficient for estimating a condition of actual track system. Also, it is converted the measured stress waveform into stress frequency histogram by the rain-flow counting methods, and then the equivalence of stress is calculated. As apply s-n curve of a new welded rail, accumulated fatigue damage ratio of laid rail and remaining service lives is estimated. This study suggest a plan of the periodic replacements of continuous welded rails based on accumulated passing tonnage classified by the types of track system.

  • PDF

누적통과톤수에 의한 레일교체기준의 타당성 분석 (A Study on Logicality for the Periodic Replacements of Continuous Welded Rail based on Accumulated Passing Tonnage)

  • 성덕룡;공선용;김박진;신효정;박용걸
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1058-1070
    • /
    • 2007
  • Internal and external railway management corporations are using the periodic replacement criteria of rail by accumulated passing tonnage and wear to maintain rails for servicing. However, internal the periodic replacement criteria of continuous welded rail(CWR) by accumulated passing tonnage is the one(50kg/m-5 million gross tonnage, 60kg/m-6 million gross tonnage) presented in Japan before. It was estimated with the fatigue life about 50kg N rail joints applied diesel train load but it wasn't applied to current conditions of track; elimination of rail joint, using the concrete slab track and operation of light train load and effect of welding, manufacturing technique, grinding of rail. Therefore, in this study, it was investigated the types of damage and cause in welded rails and examined standards and information resources. Also, this study presents preliminary data to revise the periodic replacement criteria of CWR by current accumulated passing tonnage in bending test of laid welded rail and a survey of track maintenance history of Seoul metro.

  • PDF

수직발사 유도탄의 진동시험에서 유도탄 장착방향의 영향에 대한 연구 (Study on the Effects of the Mounting Direction of Vertically-launched Missiles in Vibration Tests)

  • 이호준;김기언
    • 한국소음진동공학회논문집
    • /
    • 제23권3호
    • /
    • pp.218-225
    • /
    • 2013
  • Vertically-launched missiles are supported as erected vertically in the vertical launching system of warship, and they should be mounted in the same way when vibration-tested. However, mounting missiles vertically makes a fixture, which is a supporting structure, bulky and heavy so requiring a high-performance exciter. Mounting missiles as laid down horizontally in a vibration test is economical regarding fixture manufacturing and exciter performance, but it makes test results incorrect because the different mounting direction has effects on the test results. A bending moment due to missiles' weight happens to missiles, and resilient mounts, which support missiles in the vertical launch system, deflect differently from the real situation because of the static deflection of these mounts due to missiles' weight. If the resilient mounts supporting missiles have nonlinear force-deflection characteristics, vibration test results become more different from the true results. This paper proposes to support missiles with an additional resilient mount such as a bunge code in order to solve those problems coming from mounting vertically-launched missiles as laid down horizontally in vibration tests. The proposed approach enables to obtain the same test results as in their actual mounting condition even though vertically-launched missiles are mounted in a different direction.

Impact of Egg Laying Duration on the Occurrence of Fertilized and Unfertilized Eggs of the Newly Evolved Race of Bombyx mori, L.

  • Mathur, Vinod B.;Sarkar, Kunal
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제16권1호
    • /
    • pp.1-5
    • /
    • 2008
  • The present study was carried out with the aim to evaluate the viability of layings (delivery of fertilized and unfertilized eggs) with egg laying duration of elite bivoltine races. The temporal aspect of mating in terms of egg layings duration may also have impact on the number of eggs laid, pattern of egg laying and their viability. After different interval of egg laying duration, moth of Bombyx mori are removed from oviposition site after they have completed egg laying. Present investigation confirmed that there are no significant difference in relation to the occurrence of viable (fertilized) and non viable (unfertilized) eggs and duration of oviposition. Percentage of unfertilized eggs varied from 2.41 to 3.42% in case of CSR-3, 2.59 to 3.62% in case of CSR-6, 2.82 to 3.66% in case of CSR-16 and 2.58 to 3.40% in case of CSR-17 in different treatments. The occurrence of unfertilized eggs are also not significant in the different treatments specially in those eggs which were laid 24 hours after oviposition and kept for 4 months hibernation schedule.

내구성 부직포의 마찰 및 세탁에 의한 인장강도 및 강연도 변화 (Changes in Tensile Strength and Stiffness of Selected Durable Nonwoven Fabrics due to Abrasion and Laundering*)

  • 김철주;애브린 하게트
    • 한국의류학회지
    • /
    • 제9권3호
    • /
    • pp.35-44
    • /
    • 1985
  • This research explored the effects of abrasion, laundering, and abrasion/laundering interaction upon wear of 15 durable nonwoven fabrics. Wear was measured in terms of changes in tensile strength and stiffness. The test materials consisted of nine different dry-laid commercial interfacing fabrics of various fiber contents and six spunbonded poyester and polypropylene fabrics. Three fixed levels of abrasion and four fixed levels of laundering made up the 3$\times$4 factorial analysis used for the experiment and the analysis of variance. Findings revealed that abrasion had a greater effect than laundering on strength and stiffness of the tested fabrics. Laundering seemed related to the particular fibers used and to the fixation quality of fiber bonds. Spunbonded webs performed better than dry-laid webs in retaining tensile strength Stiffness change occurred more readily than strength change. Lighter, flexible, stretchable fabrics seemed less easily abraded than heavier, stiff, less stretchable fabrics. The interfacing fabrics of 70/20/$10\%$ nylon/polyester/rayon blends with high crosswise stretchability effectively resisted wear caused by abrasion and laundering. Further research is recommended to study the effects of longer abrasion periods and additional laundering cycles o,1 wear qualities of nonwoven fabrics. Additional factors such as amount and fixation methods of bonding agents, the effect of shear distortion, seam construction, and drycleaning solvents could also be studied.

  • PDF

신침로거리와 전타시점에 관한 연구 (A Study on the New Course Distance and the proper time to alter course)

  • 김민석
    • 수산해양교육연구
    • /
    • 제21권4호
    • /
    • pp.586-591
    • /
    • 2009
  • The marine traffic accidents go on increasing owing to the increment of marine traffic capacity, and the solutions about these matters are vigorously considering by many researchers. When the watch officer navigates to the narrow channel, bend or an area obscured by an intervening obstruction and around the harbour limit he must follow the planned track. The watch officer can safely navigate along the course laid down only when he alters his course in advance before the new course distance earlier than the course alternation point. If we call this point to be changed in advance a turning bearing, the turning bearing is decided according to the direction and the range from the clearing objects. The turning bearing helps the watch officer to determine whether the ship is at wheel-over position or not. The author in this paper suggest how to make and use a curve graph which is decided according to the direction and the distance from the clearing objects. If the watch officer utilize this curve graph he can judge swiftly and precisely whether his ship is at the wheel - over position or not.

아태지역항만국통제에 관한 양해각서의 개정과 비판 (Some Comments on Revision of Memorandum of Understanding on Port State Control in Asia-Pacific Region and Actualities of Korean PSC Regime)

  • 강동수
    • 해양환경안전학회지
    • /
    • 제7권3호
    • /
    • pp.93-106
    • /
    • 2001
  • Whether a ship is sub-standard or not shall be finally decided by the minimum standards laid down in international conventions or national standards having the same effects. The flag State is primarily responsible for implementing these standards as far as its own ships are concerned. And the port State shall, in the exercise of its rights under international law, take appropriate measures (including detention of ships identified as sub-standard), which are regarded as port State's supplementary role aiming at implementing these standards. The international standards are implemented by the regional co-operation in the form of the MOU(Memorandum of Understanding) on Port State Control in the Asia-Pacific Region on the ground that the PSC enforcement of only one country does not enable the eradication of sub-standard ships. Recently, EQUASIS which is an international database covering the whole world fleet change the regionalism of PSC into the globalization of PSC. However, there are many problems in Tokyo MOV and Korean PSC regime. In order to ensure the implementation of the standards laid down in international conventions and Tokyo MOU, the Korean and other country in Asia-Pacific shall settle the alienation from the actuality of the law, namely the problem of maritime administrative structure of non unifying PSC affairs.

  • PDF

다수의 부구간으로 나누어지는 트로프간 접수냉 전력케이불의 열해석에 관한 연구 (A Study on the Thermal Analysis of Indirect Water Cooled Power Cables Laid within Trough devided into Several Sub-Sections)

  • 문영현;김백;이태식
    • 대한전기학회논문지
    • /
    • 제41권7호
    • /
    • pp.703-711
    • /
    • 1992
  • As the underground area of the metropolitan becomes denser recently, an introduction of forced cooling system is under study to maximize the carrying capacity of existing cables in tunnels. Indirect water cooling system laid within trough will probably be adopted for the next 345KV class underground power cables in this country. The system covers a distance of 1.5-3.0Km for one water cooling interval and one water cooling interval is composed of several sub-sections that have different thermal analysis conditions. Thus the distribution of temperature in each sub-section is described by different conditions in general. In this paper a method that can accurately match the temperature of the coolant in the boundary between sub-sections has been suggested. An algorithm to find the temperature distributions effectively in the thermal system has also been presented. A computer program using this method has been tested in a smaple system and the results have shown the usefulness of this program.

  • PDF

A Study of Optimizing Cathodic Protection in Comparison of Design Methodologies

  • Choi, Young-Kwan;Choi, Sang-Yule;Shin, Myong-Chul
    • 조명전기설비학회논문지
    • /
    • 제24권11호
    • /
    • pp.23-29
    • /
    • 2010
  • The principal factor determining an optimum design method for cathodic protection is finding the protection current for preventing the corrosion of existing, already laid pipe. Some factors currently used to test designs include the sizes and lengths of pipes, soil resistivity, and the coating damage rate. We believe this method and current formulae are not optimum due to the uncertainty of determining the coating damage rate and the corrosion protection current's density. This paper analyzes the amount of protection current obtained by performing a temporary current test using data describing existing laid pipe. We then propose determining the corrosion protection current by using the temporary current test after modifying the formula. In addition, we suggest a way to choose optimized cathodic protection and the process of design by executing the design and taking account of such factors as a site condition of 34km-long non-protected water supply pipe lines (stages I and II) in ${\bigcirc}{\bigcirc}$ region, climate, interferences, and durability.