• Title/Summary/Keyword: laboratory measurement methods

Search Result 440, Processing Time 0.029 seconds

Effects of musical intervention on the fear and anxiety reduction during scaling (치석제거 시 음악중재가 공포 및 불안 감소에 미치는 영향)

  • Nam, Yong-Ok;Ju, On-Ju;Lee, Kwang-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.17 no.3
    • /
    • pp.395-404
    • /
    • 2017
  • Objectives: The purpose of this study was to identify the effects of music intervention on the patient's fear and anxiety during scaling. Methods: 360 patients who had visited W University dental hygiene laboratory were selected as study subjects and divided into experiment group and control group. Results: Study results showed that the control group (71.9%) and the experimental group (75.1%) had experiences avoiding dental treatment due to fear. In the control group (37.6%) and experimental group (40.6%), the highest influencing factor was the sound of machine and followed by pain. The experimental group preferred classical music, followed by pop songs, trot music and instrumental music. In the experimental group (83.3%), fear and anxiety were alleviated by music, and 77.9% of the patients mentioned they would recommend music for scaling to other patients. There was an interaction effect (p=0.014) between the groups before and after the measurement of the lowest blood pressure. There was a significant difference in pulse before and after pulse measurement (p=0.000). There was a significant difference in respiration between groups (p=0.042) and before and after respiration (p=0.030). Conclusions: Study results showed that music intervention that utilizes music during scaling showed significant effects on the alleviation of fear and anxiety, affecting Pulse number among vital signs. Therefore, more systematic program is to be required to alleviate dental fear and anxiety with music therapy not only for scaling, but also for dental clinic in the future.

Effects of Squat Exercise Using Balls on the Gap Interval between Knees, Q-angle, Muscle Activity in Women with Genu-Varum (안굽이무릎을 가진 여성에게 볼을 이용한 스쿼트 운동이 무릎사이 간격과 Q각, 근 활성도에 미치는 효과)

  • Lee, Keoncheol;Han, Jiwon;Bae, Wonsik
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.2
    • /
    • pp.97-107
    • /
    • 2020
  • Purpose : The purpose of this study is to investigate the effect of squat exercise using a ball on the gap between knees and Q angle of a subject with a genu-varum, and to prove the effect, to provide a clinical basis for developing into a knee correction exercise program. Methods : As a result of posture measurement through GPS, 26 female with genu-varum with a knee length of 5 cm or more were studied. The group was randomly assigned to 13 squat exercise group using ball (experimental group) and 13 general squat exercise groups (control group). The experimental group placed the ball between both knees in a position where the distance between both feet was slightly wider than the shoulder width on a flat support surface, and fixed the ball, and then squat with the start signal. The control group squats without a ball. Each group performed three sets of exercise three times a week for six weeks. Before their exercise, after three and six weeks, EMG, GPS, digital goniometer measurement, the vastus medialis (VM), the vastus lateralis (VL), and the Q-angle were measured in the squat exercise posture. EMG was measured in squat exercise posture. Results : The distance between the knees was reduced. EMG is activated in group A, the group B experimental results showed the high activity of the VL. Q-angle had increased. But the experimental group increased more than the control group. Conclusion : We have confirmed through our experiments that the distance interval between the knees during squat exercises using a ball can be reduced. Furthermore, it would also be helpful to ensure the treatment of genu-varum.

The Effect of the Core Stabilization Exercise and Thoracic Manipulation on the Respiratory Function of Chronic Low Back Pain Patients (척추 안정화 운동과 등뼈 가동성 운동이 만성 허리 통증 환자의 호흡 기능에 미치는 영향)

  • Park, Sunja;Kim, Youngmi;Han, Jiwon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.3
    • /
    • pp.43-52
    • /
    • 2020
  • Purpose : The aim of this study was to investigate the change of the respiratory function of chronic low back pain patients after the thoracic manipulation and the trunk stability exercise on chronic low back pain patients. Methods : For this study, the group of the experiment was consisted of 44 patients suffering from the low back pain chronically. The participants were divided into two groups: the control group, which was assigned for core stabilization exercise (CSE), and the experimental group, which was randomly assigned for core stabilization exercise after thoracic manipulation (CSE+TM). Both groups carried out each assigned treatment on three times a week for 8 weeks. To study the change related to measurement variable from each test groups before and after intervention, paired t-test was performed. Further, the statistics for an intergroup comparison was analyzed by covariance analysis, ANCOVA. The measurement was conducted by the respiratory function, the respiratory function was measured by forced vital capacity (FVC) and forced expiratory volume in one second (FEV1). Results : As a result, forced vital capacity (FVC) and forced expiratory volume in one second (FEV1) showed significant differences not only by each groups but also between those groups before and after the test. Conclusion : In conclusion, both experiments, the core stabilization exercise and the core stabilization exercise conducted after thoracic manipulation, on chronic low back pain patients resulted in the significant level of difference in the respiratory function. This result indicates that the thoracic manipulation is an efficient treatment for improving the respiratory function for chronic low back pain patients.

The Antioxidation Effect of Mutimo cylindricus Extract and Its Influence on Cell Bioactivity (회초리말(Mutimo cylindricus)의 항산화, 항염 및 미백 활성)

  • Park, Sang-Nam;Lee, Ok-Hee
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.11
    • /
    • pp.279-287
    • /
    • 2020
  • The objective of this study was to evaluate functionality of Mutimo cylindricus as a cosmetic ingredient, one of the brown algae. The M. cylindricus 70% ethanol extract was manufactured for antioxidant measurement. DPPH and ABTS methods were used to measure antioxidants, and its EC50 values were 2.040 and 2.182 mg/mL in each experiment. The measurement of total polyphenol contents and reducing power showed total polyphenol content of 103 mg gallic acid/g extract and reducing power of 134 mg ascorbic acid/g extract. To measure cell toxicity, MTT method was used, and its result showed that the extract was not cytotoxic. And it has anti-inflammatory and whitening activity at concentrations of 100 ㎍/mL. The result confirmed that M. cylindricus extract is available as a cosmetic material with whitening and anti-inflammatory properties.

Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions

  • Jiang, Tingting;Lee, Sang-Mi;Hou, Yanan;Chang, Xin;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.46 no.3
    • /
    • pp.129-136
    • /
    • 2016
  • Objective: To investigate the dimensional accuracy of digital dental models obtained from the dental cone-beam computed tomography (CBCT) scan of alginate impressions according to the time elapse when the impressions are stored under ambient conditions. Methods: Alginate impressions were obtained from 20 adults using 3 different alginate materials, 2 traditional alginate materials (Alginoplast and Cavex Impressional) and 1 extended-pour alginate material (Cavex ColorChange). The impressions were stored under ambient conditions, and scanned by CBCT immediately after the impressions were taken, and then at 1 hour intervals for 6 hours. After reconstructing three-dimensional digital dental models, the models were measured and the data were analyzed to determine dimensional changes according to the elapsed time. The changes within the measurement error were regarded as clinically acceptable in this study. Results: All measurements showed a decreasing tendency with an increase in the elapsed time after the impressions. Although the extended-pour alginate exhibited a less decreasing tendency than the other 2 materials, there were no statistically significant differences between the materials. Changes above the measurement error occurred between the time points of 3 and 4 hours after the impressions. Conclusions: The results of this study indicate that digital dental models can be obtained simply from a CBCT scan of alginate impressions without sending them to a remote laboratory. However, when the impressions are not stored under special conditions, they should be scanned immediately, or at least within 2 to 3 hours after the impressions are taken.

Pain and Blood Volume with Different Sampling Sites and Puncture Depths in Vacuum Assisted Auto Lancing Technique for Blood Glucose Test (혈당검사를 위한 진공자동채혈기법사용시 채혈부위와 바늘침투깊이에 따른 통증과 채혈량 분석)

  • Park, Mi-Sook;Park, Kyung-Soon;Kim, Kyung-Ah;Cha, Young-Joo;Jun, Myung-Hee;Kim, Tae-Im;Lee, Tae-Soo;Cha, Eun-Jong
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.12 no.2
    • /
    • pp.265-271
    • /
    • 2006
  • Purpose: To analyze the newly developed vacuum assisted auto-lancing technique applied to the forearm for the purpose of obtaining an adequate blood sample for glucose test with minimal pain. Methods: Visual and facial pain measures were introduced to compare lancing pain between the forearm and fingertip in 58 normal females. Sampled blood volumes were accurately measured by computer scanning technique. Results: Visual pain measure demonstrated significant pain reduction effect of the forearm sampling compared with the traditional fingertip sampling, which was also consistent with facial pain measure results. Blood volume more than $0.5{\mu}L$, enough for blood glucose testing with modern glucometers, was collected in 399(86%) of 464 forearm samples. Conclusions: Capillary blood sampling could be performed with minimal pain on the forearm by the newly developed vacuum assisted auto-lancing technique. With some resampling when necessary, the forearm sampling seemed very useful, considering almost no pain felt by the patients.

  • PDF

Study of four weeks repeated-dose toxic test of Sweet Bee Venom in rats Original Articles (Sweet Bee Venom의 rat를 이용한 4주 반복 근육시술 독성시험)

  • Kwon, Hae-Yon;Kwon, Ki-Rok
    • Journal of Pharmacopuncture
    • /
    • v.14 no.1
    • /
    • pp.5-24
    • /
    • 2011
  • Objective: This study was performed to analyse four weeks repeated -dose toxicity of Sweet Bee Venom (SBV-pure melittin, the major component of honey bee venom) in rats. Methods: All experiments were conducted under the regulations of Good Laboratory Practice (GLP) at Biotoxtech Company, a non-clinical study authorized institution. Male and female rats of 5 weeks old were chosen for the pilot study of four weeks repeated-dose toxicity and was injected at the level of 0.56 mg/kg body weight (eighty times higher than the clinical application dosage as the high dosage), followed by 0.28 and 0.14 mg/kg as midium and low dosage, respectively. Equal amount of normal saline was injected as the control group every day for four weeks. Results: 1. No mortality was witnessed in all of the experiment groups. 2. All experiment groups appealed pain sense in the treating time compared to the control group, and side effects such as hyperemia and movement disorder were observed around the area of injection in all experiment groups, and the higher dosage in treatment, the higher occurrence in side effects. 3. Concerning weight measurement, neither male nor female groups showed significant changes compared to the control group. 4. Concerning to the CBC and biochemistry, all experiment groups didn't show any significant changes compared to the control group. 5. Concerning weight measurement of organs, experiment groups didn't show any significant changes compared to the control group. 6. To verify abnormalities of organs and tissues, those such as cerebellum, cerebrum, liver, lung, kidney, and spinal cords were removed and we conducted histologocal observation with H-E staining. Concerning the histologocal observation of liver tissues, some fatty changes were observed around portal vein in 0.56 mg/kg experiment group. But another organs were not detected in any abnormalities. 7. The proper high dosage of SBV for the thirteen weeks repeated test in rats may be 0.28 mg/kg in one time. Conclusion: Above findings suggest that SBV is relatively safe treatment medium. Further studies on the subject should be conducted to yield more concrete evidences.

Estimation of liquid limit of cohesive soil using video-based vibration measurement

  • Matthew Sands;Evan Hayes;Soonkie Nam;Jinki Kim
    • Geomechanics and Engineering
    • /
    • v.33 no.2
    • /
    • pp.175-182
    • /
    • 2023
  • In general, the design of structures and its construction processes are fundamentally dependent on their foundation and supporting ground. Thus, it is imperative to understand the behavior of the soil under certain stress and drainage conditions. As it is well known that certain characteristics and behaviors of soils with fines are highly dependent on water content, it is critical to accurately measure and identify the status of the soils in terms of water contents. Liquid limit is one of the important soil index properties to define such characteristics. However, liquid limit measurement can be affected by the proficiency of the operator. On the other hand, dynamic properties of soils are also necessary in many different applications and current testing methods often require special equipment in the laboratory, which is often expensive and sensitive to test conditions. In order to address these concerns and advance the state of the art, this study explores a novel method to determine the liquid limit of cohesive soil by employing video-based vibration analysis. In this research, the modal characteristics of cohesive soil columns are extracted from videos by utilizing phase-based motion estimation. By utilizing the proposed method that analyzes the optical flow in every pixel of the series of frames that effectively represents the motion of corresponding points of the soil specimen, the vibration characteristics of the entire soil specimen could be assessed in a non-contact and non-destructive manner. The experimental investigation results compared with the liquid limit determined by the standard method verify that the proposed method reliably and straightforwardly identifies the liquid limit of clay. It is envisioned that the proposed approach could be applied to measuring liquid limit of soil in practical field, entertaining its simple implementation that only requires a digital camera or even a smartphone without the need for special equipment that may be subject to the proficiency of the operator.

Measurement of Individuals' Emotional Stress Responses to Construction Noise through Analysis of Human Brain Waves

  • Hwang, Sungjoo;Jebelli, Houtan;Lee, Sungchan;Chung, Sehwan;Lee, SangHyun
    • International conference on construction engineering and project management
    • /
    • 2020.12a
    • /
    • pp.237-242
    • /
    • 2020
  • Construction noise is among the most critical stressors that adversely affect the quality of life of the people residing near construction sites. Many countries strictly regulate construction noise based on sound pressure levels, as well as timeslots and type of construction equipment. However, individuals react differently to noise, and their tolerance to noise levels varies, which should be considered when regulating construction noise. Although studies have attempted to analyze individuals' stress responses to construction noise, the lack of quantitative methods to measure stress has limited our understanding of individuals' stress responses to noise. Therefore, the authors proposed a quantitative stress measurement framework with a wearable electroencephalogram (EEG) sensor to decipher human brain wave patterns caused by diverse construction stressors (e.g., worksite hazards). This present study extends this framework to investigate the feasibility of using the wearable EEG sensor to measure individuals' emotional stress responses to construction noise in a laboratory setting. EEG data were collected from three subjects exposed to different construction noises (e.g., tonal vs. impulsive noises, different sound pressure levels) recorded at real construction sites. Simultaneously, the subjects' perceived stress levels against these noises were measured. The results indicate that the wearable EEG sensor can help understand diverse individuals' stress responses to nearby construction noises. This research provides a more quantitative means for measuring the impact of the noise generated at a construction site on neighboring communities, which can help frame more reasonable construction noise regulations that consider various types of residents in urban areas.

  • PDF

Marginal fit of three different nanocomposite inlays fabricated with computer-aided design/computer-aided manufacturing (CAD/CAM) technology: a comparative study

  • Hyunsuk Choi;Jae-Young Jo;Min-Ho Hong
    • Journal of Yeungnam Medical Science
    • /
    • v.41 no.2
    • /
    • pp.80-85
    • /
    • 2024
  • Background: This study aimed to compare and evaluate the marginal fit of nanocomposite computer-aided design/computer-aided manufacturing (CAD/CAM) inlays. Three types of nanocomposite CAD/CAM blocks (HASEM, VITA Enamic, and Lava Ultimate) were used as materials. Methods: Class II disto-occlusal inlay restorations were prepared on a typodont mandibular right first molar using diamond rotary instruments. The inlays were fabricated using CAD/CAM technology and evaluated using the silicone replica technique to measure marginal gaps at five locations on each inlay. The data were analyzed by two-way analysis of variance and Tukey post hoc tests (α=0.05). Results: There were no significant differences in the marginal gaps based on the type of nanocomposite CAD/CAM inlay used (p=0.209). However, there was a significant difference in the marginal gaps between the measurement regions. The gingival region consistently exhibited a larger marginal gap than the axial and occlusal regions (p<0.001). Conclusion: Within the limitations of this in vitro study, the measurement location significantly influenced the marginal fit of class II disto-occlusal inlay restorations. However, there were no significant differences in the marginal gaps among the different types of CAD/CAM blocks. Furthermore, the overall mean marginal fits of the class II disto-occlusal inlay restorations made with the three types of nanocomposite CAD/CAM blocks were within the clinically acceptable range.