References
- Fleming PS, Marinho V, Johal A. Orthodontic measurements on digital study models compared with plaster models: a systematic review. Orthod Craniofac Res 2011;14:1-16. https://doi.org/10.1111/j.1601-6343.2010.01503.x
- Naidu D, Scott J, Ong D, Ho CT. Validity, reliability and reproducibility of three methods used to measure tooth widths for bolton analyses. Aust Orthod J 2009;25:97-103.
- White AJ, Fallis DW, Vandewalle KS. Analysis of intra-arch and interarch measurements from digital models with 2 impression materials and a modeling process based on cone-beam computed tomography. Am J Orthod Dentofacial Orthop 2010;137:456.e1-9.
- Wiranto MG, Engelbrecht WP, Tutein Nolthenius HE, van der Meer WJ, Ren Y. Validity, reliability, and reproducibility of linear measurements on digital models obtained from intraoral and cone-beam computed tomography scans of alginate impressions. Am J Orthod Dentofacial Orthop 2013;143:140-7. https://doi.org/10.1016/j.ajodo.2012.06.018
- Naidu D, Freer TJ. Validity, reliability, and reproducibility of the iOC intraoral scanner: a comparison of tooth widths and Bolton ratios. Am J Orthod Dentofacial Orthop 2013;144:304-10. https://doi.org/10.1016/j.ajodo.2013.04.011
- Bailey E, Nelson G, Miller AJ, Andrews L, Johnson E. Predicting tooth-size discrepancy: A new formula utilizing revised landmarks and 3-dimensional laser scanning technology. Am J Orthod Dentofacial Orthop 2013;143:574-85. https://doi.org/10.1016/j.ajodo.2012.09.022
- Hayashi K, Sachdeva AU, Saitoh S, Lee SP, Kubota T, Mizoguchi I. Assessment of the accuracy and reliability of new 3-dimensional scanning devices. Am J Orthod Dentofacial Orthop 2013;144:619-25. https://doi.org/10.1016/j.ajodo.2013.04.021
- Grunheid T, McCarthy SD, Larson BE. Clinical use of a direct chairside oral scanner: an assessment of accuracy, time, and patient acceptance. Am J Orthod Dentofacial Orthop 2014;146:673-82. https://doi.org/10.1016/j.ajodo.2014.07.023
- Flugge TV, Schlager S, Nelson K, Nahles S, Metzger MC. Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner. Am J Orthod Dentofacial Orthop 2013;144:471-8. https://doi.org/10.1016/j.ajodo.2013.04.017
- Patzelt SB, Lamprinos C, Stampf S, Att W. The time efficiency of intraoral scanners: an in vitro comparative study. J Am Dent Assoc 2014;145:542-51. https://doi.org/10.14219/jada.2014.23
- Torassian G, Kau CH, English JD, Powers J, Bussa HI, Marie Salas-Lopez A, et al. Digital models vs plaster models using alginate and alginate substitute materials. Angle Orthod 2010;80:662-9. https://doi.org/10.2319/072409-413.1
- Dahlberg G. Statistical methods for medical and biological students. London, United Kingdom: George Allen & Unwin; 1940.
- Rheude B, Sadowsky PL, Ferriera A, Jacobson A. An evaluation of the use of digital study models in orthodontic diagnosis and treatment planning. Angle Orthod 2005;75:300-4.
- Alcan T, Ceylanoglu C, Baysal B. The relationship between digital model accuracy and time-dependent deformation of alginate impressions. Angle Orthod 2009;79:30-6. https://doi.org/10.2319/100307-475.1
- Erbe C, Ruf S, Wostmann B, Balkenhol M. Dimensional stability of contemporary irreversible hydrocolloids: humidor versus wet tissue storage. J Prosthet Dent 2012;108:114-22. https://doi.org/10.1016/S0022-3913(12)60117-6
- Walker MP, Burckhard J, Mitts DA, Williams KB. Dimensional change over time of extended-storage alginate impression materials. Angle Orthod 2010;80:1110-5. https://doi.org/10.2319/031510-150.1
- Todd JA, Oesterle LJ, Newman SM, Shellhart WC. Dimensional changes of extended-pour alginate impression materials. Am J Orthod Dentofacial Orthop 2013;143(4 Suppl):S55-63. https://doi.org/10.1016/j.ajodo.2012.06.016
Cited by
- Assessment of the Accuracy of Orthodontic Digital Models in Dental Education vol.13, pp.None, 2016, https://doi.org/10.12973/eurasia.2017.00844a
- Chemical analysis and microstructure examination of extended-pour alginate impression versus conventional one (characterization of dental extended-pour alginate) vol.67, pp.10, 2018, https://doi.org/10.1080/00914037.2017.1362636
- Model Analysis of Digital Models in Moderate to Severe Crowding: In Vivo Validation and Clinical Application vol.2018, pp.None, 2016, https://doi.org/10.1155/2018/8414605
- 디지털 치과모형의 정확도 평가 방법에 대한 고찰 vol.35, pp.2, 2019, https://doi.org/10.14368/jdras.2019.35.2.55
- Linear Accuracy of Full-Arch Digital Models Using Four Different Scanning Methods: An In Vitro Study Using a Coordinate Measuring Machine vol.10, pp.8, 2020, https://doi.org/10.3390/app10082741