• Title/Summary/Keyword: joint stability

Search Result 889, Processing Time 0.027 seconds

Chronic Varus Instability of the Hallux Interphalangeal Joint in College Taekwondo Athelete - A Case Report - (대학 태권도 선수의 족무지 지간 관절의 만성 내반 불안정성 - 1례 보고-)

  • Jung, Hong-Geun;Park, Sin-Hyoung
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.7 no.2
    • /
    • pp.142-145
    • /
    • 2008
  • Forefoot injuries are common in runners or martial art athletes, but due to the anatomical stability, collateral ligament injury of the hallucal interphalangeal joint has been rarely reported. We report a college Taekwondo athlete with chronic varus instability of the hallucal interphalangeal joint due to chronic lateral collateral ligament rupture. The patient had been treated with lateral ligament reconstruction and achieved good clinical outcome.

  • PDF

Cyclic Oxidation Behavior of Fe-Cr-Al Joint Brazed with Nickel-Base Filler Metal (Ni계 합금으로 브레이징된 Fe-Cr-Al 합금 접합부의 주기산화거동)

  • Mun, Byeong-Gi;Choe, Cheol-Jin;Park, Won-Uk
    • 연구논문집
    • /
    • s.29
    • /
    • pp.141-149
    • /
    • 1999
  • Brazing of Fe-Cr-Al alloy was carried out at $1200^{\circ}C$ in vacuum furnace using nickel-based filler metals : BNi-5 powder(Ni-Cr-Si-Fe base alloy} and MBF-50 foil (Ni-Cr-Si-B). The effect of boron content on the stability of oxide scale on the brazed joint was investigated by means of cyclic oxidation test performed at $1050^{\circ}C$ and $1200^{\circ}C$. Apparently, the joints brazed with MBF-50 containing boron showed relatively stable oxidation rates compared to boron-free BNi-5 at both temperatures. However, it was considered that the slower weight loss of MBF-50 brazed specimen wasn’t resulted from the low oxidation rate but from the spallation of oxide layer. The oxide layer consisted of thick spinel oxide on the surface and $Al_2 O_3$ internal oxide layer along the interface between mother alloy and braze, the mother alloy was also eroded seriously by the formation of spinel oxides such as $FeCr_2 O_4$ and $NiCr_2 O_4$ on the surface, likely to be induced by the change of oxide forming mechanism due to diffusion of boron from the braze. On the contrary, the joint brazed with BNi-5 showed the good oxidation resistance during the cyclic oxidation test. It seems that the oxidation can be retarded by the formation of stable $Al_2 O_3$ layer at the surface.

  • PDF

Analysis of the DC Resistance of the Butt Joint using the Random Contact Patterns of Strands

  • Lee, Ho-Jin;Lee, Sang-Il;Lee, Bong-Sang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.4
    • /
    • pp.17-21
    • /
    • 2004
  • The butt joint was verified to satisfy the thermal stability of the ITER magnet system through the ITER CS model coil test. Since the contact area in the butt joint is limited to the cross section of the cable, it is necessary to analyze and control the joining parameters precisely for improving the DC resistance. It is difficult to simulate the cables, which are composed of a lot of strands, as three-dimensional models using the commercial code. The random numbers were used to simulate many kinds of contact patterns of the strands on the bonding surface for calculating the bonding area and the DC resistance of the butt joint. The calculated DC resistance decreases with an increase of cable filling factor in terminal. The calculated DC resistance of a 0.9 cable filling factor is about 0.48 n-Ohm, which is about one-tenth of that in the CS model coil test when not considering the electrical contact resistance. From this difference, the electrical contact resistance between the strands and copper sheet was calculated.

A Study on the Joint Performance Change of Self-Admixed Waterproofing Sheet by Induced Bonding of Asphalt Compound (아스팔트 컴파운드 간 접합을 유도한 자착식 방수 시트의 시트 간 접합부 성능 변화 연구)

  • Kim, Dong-Bum;Kim, Sun-Do;Park, Jin-Sang;Ko, Sam Seog;Kim, Byoung-Il;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.234-235
    • /
    • 2017
  • The bonding of the asphalt-based waterproof sheet is carried out in such a manner that the sheet and the sheet are adhered together and the lower adhesive layer of one sheet is adhered to the upper film layer of the other sheet, and the asphalt layer and the PE or HDPE film layer are bonded. When the joints are formed in the form of junctions between heterogeneous materials and exposed to the concrete joint movements and other deteriorating factors, the integrity of the joints can deteriorate and problems such as lifting and peeling off of the joints can occur. Therefore, this study was carried out to prevent unstable joint adhesion of the asphalt compound and film layer and to prevent defects in the adhesion between self - adhesive waterproof sheets. The self-adhesive waterproof sheet of this study can maximize bond stability by inducing bond between asphalt compounds during sheet-to-sheet bonding, thereby improving bonding strength.

  • PDF

Change and Development of the Orthopaedic Manual Therapy (정형물리치료의 변화와 발전)

  • Ju Mu-Yeol;Kim Seung-Joon;Park Seung-Kyu;Jung Yeon-Woo;Bae Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.4
    • /
    • pp.475-486
    • /
    • 2002
  • Orthopaedic manual therapy(OMT) includes knowledge in arthokinematic, biological, behavioral, biomechanical, patholology, anatomy, and clinical science. it allows proper approach to patient evaluation and program development and relieves joint and soft tissue lesions. The OMT has sports injurys, traumatic, developmental, and neuromusculoskeletal disorders of acute and chronic states, and prevention of dysfunction as well as the development, improvement, restoration, or maintenance of joint and muscular mobility, stability, relaxation, strenth, endurance, balance, and functional skills. The purpose of this article has to define and clarify the change and development of basic concepts of orthopaedic manual therapy. OMT is ancient in origin. The book of ' Manipulation Past and Present ' contains pictures recording various types of joint mobilization by Hippocrates. Recently, there are many kinds of manual therapeutic maneuvers to assess and relieve joint and soft tissue lesions developed by James Cyriax, John McM Mennell, Brian R Mullign, Robin McKenzie, Freddy Kaltenborn, Geoffrey Maitland, and Ola Grimsby.

  • PDF

Surgical Treatment of the Acute Acromioclavicular Joint Dislocation with a LIGASTIC Artificial Ligament (LIGASTIC 인공인대를 이용한 급성 견봉 쇄골 탈구의 수술적 치료)

  • Choi Sun-Jin;Kim Sang-Hyo;Park Han-Sung
    • Clinics in Shoulder and Elbow
    • /
    • v.8 no.2
    • /
    • pp.135-140
    • /
    • 2005
  • Purpose: To find out the early results after surgical treatment of the acute acromioclavicular dislocation with LIGASTIC artificial ligament. Material and Method: 6 patients who were diagnosed as acute acomioclavicular joint dislocation and treated with LIGASTIC artifical ligament through March 2005 to July 2005. The radiologic and clinical results using Imatani evaluation system were analyzed. Results: By clinical evaluation, 4 cases(67%) were excellent and 2 cases(33%) were good. By radiologic evaluation, 3 cases(50%) were excellent and 3 cases(50%) were good. All cases showed satisfactory results. Till the final follow up, there were no complication. Conclusion: Surgical treatment of the acute acromioclavicular dislocation with LIGASTIC articifial ligament is simple, but provides enough stability for early postoperative rehabilitation, decreases arthritis of acomioclavicular joint and there is no burden of removal of the fixture, so it is thought as a very effective surgery.

Effects of Knee Joint Muscle Fatigue and Overweight on the Angular Displacement and Moment of the Lower Limb Joints during Landing (무릎 관절 근육 피로와 과체중이 착지 시 하지 관절의 각변위와 모멘트에 미치는 영향)

  • Kim, Tae-Hyeon;Youm, Chang-Hong
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.1
    • /
    • pp.63-76
    • /
    • 2013
  • The purpose of this study was to investigate the effects of knee joint muscle fatigue and overweight on the angular displacement and moments of the lower limb joints during landing. Written informed consent forms, which were approved by the human subject research and review committee at Dong-A University, were provided to all subjects. The subjects who participated in this study were divided into 2 groups: a normal weight group and an overweight group, consisting of 15 young women each. The knee joint muscle fatigue during landing was found to increase the dynamic stability by minimizing the movements of the coronal and horizontal planes and maintaining a more neutral position to protect the knee. The effect of body weight during landing was better in the normal weight group than in the overweight group, with the lower limbs performing their shock-absorbing function in an efficient manner through increased sagittal movement. Therefore, accumulated fatigue of knee joint muscles or overweight may be highly correlated with the increase in the incidence of injury during landing after jumping, descending stairs, and downhill walking.

Design Study on Waterproof 4-axis Manipulator (방수형 경량 로봇팔의 설계 연구)

  • Choi, Hyeung-Sik;Jo, Jong-Rae;Woo, Myoung-Man;Seo, Jung-Min;Ju, Young-Do;Kang, Jung-Suk
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.2
    • /
    • pp.100-106
    • /
    • 2013
  • This paper deals with the design method for a small waterproof 4-axis robot arm. An extensive analysis was performed on the torque applied to the robot joint as a result of the payload, as well as the design of the joint actuator capacity. In addition, a study was undertaken on the design of a waterproof joint actuator that works at depths greater than 10 m and the wiring design for a small waterproof connector to avoid obstructing the robot motion. Finally, a finite element method simulation was carried out to analyze the strength of the designed robot arm link, and its stability was verified through a simulation test.

Comparison of the Balancing Capacity and Strength of Taping for the Knee Joint and Repeated Measurements (무릎관절 멀리건 테이핑이 균형능력과 각근력에 미치는 효과와 측정의 반복에 의한 효과 비교)

  • Park, Bo-hyun;Choi, Su-hong;Kim, Sung-joong;Park, Su-hyung;Oh, Kang-o
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.24 no.2
    • /
    • pp.9-15
    • /
    • 2018
  • Background: The purpose of this study was to compare the effects of mulligan taping on knee joints on balance ability and strength with repeated measurements. Methods: Seventeen patients were randomly assigned to the 8 taping group and the 9 repeat measurement group. To measure the balance ability, fall risk assessment equipment was used, and the measurement of the muscle strength was performed by using the equipment of the same company. Results: Balanced abilities and muscle strength were increased in groups with taping only after Mulligan taping. Conclusions: The application of mulligan taping did not have the effect of stimulating the inherent receptive sensation. However, active grouping of the knee joint taping only, and muscle strength and muscle strength were increased. It increases the stability and activity of the muscles that operate on the balance of the active knee joint and muscle strength, thereby enhancing exercise prevention and prevention performance and exercise performance.

Experimental and numerical investigation on exposed RCFST column-base Joint

  • Ben, Mou;Xingchen, Yan;Qiyun, Qiao;Wanqiu, Zhou
    • Steel and Composite Structures
    • /
    • v.45 no.5
    • /
    • pp.749-766
    • /
    • 2022
  • This paper investigates the seismic performance of exposed RCFST column-base joints, in which the high-strength steel bars (USD 685) are set through the column and reinforced concrete foundation without any base plate and anchor bolts. Three specimens with different axial force ratios (n = 0, 0.25, and 0.5) were tested under cyclic loadings. Finite element analysis (FEA) models were validated in the basic indexes and failure mode. The hysteresis behavior of the exposed RCFST column-base joints was studied by the parametrical analysis including six parameters: width of column (D), width-thickness ratio (D/t), axial force ratio (n), shear-span ratio (L/D), steel tube strength (fy) and concrete strength (fc). The bending moment of the exposed RCFST column-base joint increased with D, fy and fc. But the D/t and L/D play a little effect on the bending capacity of the new column-base joint. Finally, the calculation formula is proposed to assess the bending moment capacities, and the accuracy and stability of the formula are verified.