• 제목/요약/키워드: joint stability

검색결과 889건 처리시간 0.046초

임상가를 위한 특집 2 - 인공 턱관절 전치환술 (Alloplastic total temporomandibular joint replacement)

  • 허종기
    • 대한치과의사협회지
    • /
    • 제50권5호
    • /
    • pp.256-261
    • /
    • 2012
  • Temporomandibular joint (TMJ) prosthesis have been hesitated to use because of bitter memories about Proplast-Teflon interpositional TMJ implants. Many clinicians, however, are trying to use total TMJ prosthesis with getting continuous long-term follow-up results. Alloplastic total TMJ replacement have been applied to much more patients who have failed previous TMJ prostheses or TMJ implants, fibrous/bony ankylosis, severe osteoarthritis, degenerative joint disease, idiopathic condylar resorption, condyle loss by trauma or tumor resection, and other bony destructive diseases. Nowadays three types of total TMJ prosthesis are widely used. In this article, indications, types of prosthesis, safety and stability would be demonstrated with a case report.

Torque Sensorless Decentralized Position/Force Control for Constrained Reconfigurable Manipulator via Non-fragile H Dynamic Output Feedback

  • Zhou, Fan;Dong, Bo;Li, Yuanchun
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.418-429
    • /
    • 2018
  • This paper studies the decentralized position/force control problem for constrained reconfigurable manipulator without torque sensing. A novel joint torque estimation scheme that exploits the existing structural elasticity of the manipulator joint with harmonic drive model is applied for each joint module. Based on the estimated joint torque and dynamic output feedback technique, a decentralized position/force control strategy is presented. In order to solve the problem of controller parameter perturbation, the non-fragile robust technique is introduced into the dynamic output feedback controller. Subsequently, the stability of the closed-loop system is proved using the Lyapunov theory and linear matrix inequality (LMI) technique. Finally, two 2-DOF constrained reconfigurable manipulators with different configurations are applied to verify the effectiveness of the proposed control scheme in numerical simulation.

Stability Analysis of Visual Servoing with Sliding-mode Estimation and Neural Compensation

  • Yu Wen
    • International Journal of Control, Automation, and Systems
    • /
    • 제4권5호
    • /
    • pp.545-558
    • /
    • 2006
  • In this paper, PD-like visual servoing is modified in two ways: a sliding-mode observer is applied to estimate the joint velocities, and a RBF neural network is used to compensate the unknown gravity and friction. Based on Lyapunov method and input--to-state stability theory, we prove that PD-like visual servoing with the sliding mode observer and the neuro compensator is robust stable when the gain of the PD controller is bigger than the upper bounds of the uncertainties. Several simulations are presented to support the theory results.

Conflict Analysis of the Nanjing Yuhuan and A.O Smith Joint Venture Case

  • Yu, Yunxia;Wang, Ying
    • Asian Journal of Business Environment
    • /
    • 제8권1호
    • /
    • pp.7-15
    • /
    • 2018
  • Purpose -This paper is to study the process of the negative effects of Sino-foreign joint ventures, hoping to find out an effective path in which local enterprises can avoid the risks in the utilization of foreign capital, and ultimately achieve independent innovation. Research design, data, and methodology -The outflow of assets, the loss of local brands and the "technology hollowing-out" problem brought by joint ventures is becoming more and more serious. Based on conflict analysis graph model, this paper takes Yuhuan joint venture as an example to identify the conflict problem in Sino-foreign joint ventures. Results -The results of the stability analysis show that establishing joint venture cannot really realize the introduction of technology because the technology is fully controlled by the foreign part. So when introducing foreign capital, local enterprises should participate in R&D and master the initiative. Conclusions - Local enterprises should pay attention to patent containment and technology blockade of multinationals. Domestic enterprises should try to protect state-owned assets and local brands in Sino-foreign joint ventures. Independent innovation is the most effective strategy for the development of enterprises in China.

3DEC을 이용한 무등산국립공원 입석대 주상절리대의 안정성 평가 (Evaluation of the Stability of Ipseok-dae Columnar Joints in Mudeungsan National Park Using 3DEC)

  • 노정두;강성승
    • 지질공학
    • /
    • 제32권3호
    • /
    • pp.351-361
    • /
    • 2022
  • 본 연구에서는 무등산국립공원 입석대 주상절리대의 거동을 예측하고 안정성을 파악하기 위하여 수치해석을 실시하였다. 수치해석은 불연속체 해석이 가능한 개별요소법 기반인 3DEC을 사용하였다. 수치해석 시 사용한 지반 물성의 결과 평균 밀도는 2.68 kN/m3 평균 수직강성은 3.15 GPa/m, 평균 전단강성은 1.00 GPa/m, 평균 점착력은 0.51 MPa, 평균 마찰각은 33°으로 나타났다. 입석대 주상절리대 전망대와 등산로 사이 15개의 입석대 주상절리대에 대하여 현장조사 결과를 바탕으로 모델링을 실시하였다. 수치해석 시 주상절리 윗면과 밑면의 모서리의 변위를 분석하여 각 주상절리의 거동을 분석하였고, 최대 변위는 6번 주상절리에서 약 0.67 mm로 가장 크게 나타났고, 최소 변위는 11번 주상절리에서 0.21 mm로 가장 크게 나타났다. 수치해석 결과 최소변위가 가장 크게 발생한 11번 주상절리 내부의 분리면 5개 거동을 분석한 결과 2층에서 가장 큰 변위가 발생하였고, 그 다음으로 5층, 4층, 1층, 그리고 3층 순으로 나타났다. 이를 통해 입석대 주상절리 15개에서 발생한 변위의 총량을 고려하면 안정한 것으로 판단된다. 하지만 무등산국립공원의 문화적, 역사적 가치를 고려해볼 때 사면전체 안정성 뿐만 아니라 입석대 주상절리 개별 블록에 대한 모니터링도 실시하여 현재의 안정성을 유지해야할 것으로 사료된다.

인솔의 아치높이 및 경도 선호도가 정적 아치 높이 및 발목 안정성에 미치는 영향 (Effects of Preferred Arch Height and Hardness of the Insole on Static Arch Height and Ankle Stability)

  • Sihyun Ryu;Young-Seong Lee;Soo-Ji Han;Sang-Kyoon Park
    • 한국운동역학회지
    • /
    • 제33권1호
    • /
    • pp.25-33
    • /
    • 2023
  • Objective: The purpose of this study was to investigate the differences in static arch height and ankle stability according to the preference for insole height and hardness in the arch area. Method: The study participants were 20 adult males (age: 22.7 ± 1.8 yrs., height: 175.3 ± 4.3 cm, body weight: 72.5 ± 7.7 kg). First, the arch heights of all subjects were measured in static postures (sitting and standing). The inversion and eversion movements of the ankle joint were analyzed during walking (1.3 m/s & 1.7 m/s) and running (2.7 m/s & 3.3 m/s). The variables (static arch height, and inversion and eversion angle of ankle joint) were compared by classifying groups according to the preference for the height and hardness of the arch of the insole. First, it was divided into a high arch insole preference group (HAG, n=8) and a low arch insole preference group (LAG, n=12) according to the preference for the arch height of the insole. Second, it was divided into a high hardness insole preference group (HHG, n=7), medium hardness insole preference group (MHG, n=7), and low hardness insole preference group (LHG, n=6), according to the preference for the arch hardness of the insole. Results: First, the range of motion (ROM) of inversion-eversion at the ankle joint during walking was statistically smaller in HAG than in LAG (p<.05). Second, the arch height change of HHG was statistically greater than that of MHG and LHG (p<.05). Conclusion: In the case of flexible flat feet with a large change in arch height, providing a high hardness arch insole that can disperse foot pressure can improve comfort. It was found that people with high medial and lateral sway of the ankle joint preferred a low arch insole, but it is necessary to differentiate and compare the insole heights of the arch part in detail. In addition, in the case of fast motion such as running, the preference for the arch height and hardness of the insole was not related to the static arch height and ankle stability.

조임회전력이 임플랜트-지대주 나사 연결부의 안정성에 미치는 영향 (Influence of Tightening Torque on Implant-Abutment Screw Joint Stability)

  • 신현모;정창모;전영찬;윤미정;윤지훈
    • 대한치과보철학회지
    • /
    • 제46권4호
    • /
    • pp.396-408
    • /
    • 2008
  • 연구목적: 임플랜트 치료에서 가장 흔히 발생하는 기계적 문제점 중 하나는 나사의 풀림이다. 지대주 나사에 조임회전력을 가하는 목적은 나사를 신장시켜, 신장된 나사의 인장력에 의한 지대주와 고정체간의 압축력을 통해 연결부의 안정성을 부여하는 데 있다. 조임 회전력의 결과로 나타나는 전하중의 크기는 다양한 요소에 의해 영향을 받기 때문에, 동일한 조임회전력을 적용하였다 할지라도 임플랜트 시스템의 종류에 따라 전하중의 크기가 달라질 수 있다. 따라서 지대주 나사 연결부의 안정성을 위한 다양한 임플랜트 시스템의 적정 조임회전력 크기에 관한 연구가 필요하다. 본 연구에서는 external butt joint와 두 가지 internal cone 연결형태를 갖는 임플랜트 시스템들에서 지대주 나사의 조임회전력이 임플랜트-지대주 나사 연결부의 안정성에 미치는 영향을 하중 전후의 풀림회전력 측정을 통해 알아보고자 하였다. 연구재료 및 방법: External butt joint 형태를 가지는 US II 시스템과 $8^{\circ}$ internal cone 연결형태의 SS II 및 $11^{\circ}$ internal cone 연결형태의 GS II 시스템에서 20 Ncm, 30 Ncm, 그리고 40 Ncm의 각기 다른 조임회전력을 적용한 후 초기 풀림회전력 및 상실률과 $10^5$회의 반복하중 후의 풀림회전력 및 상실률을 비교 분석하였다. 연구결과 및 결론: 1. 초기 풀림회전력과 하중 후 풀림회전력은 조임회전력의 크기가 증가할수록 크게 나타났다 (P < .05). 2. 초기 풀림회전력 상실률은 SS II 시스템에서는 조임회전력 크기에 따른 차이가 없었으나 (P > .05), GS II와 US II에서는 20 Ncm 보다 40Ncm의 조임회전력에서 더 낮게 나타났다 (P < .05). 3. 하중 후 풀림회전력 상실률은 세 시스템 모두 30 Ncm의 조임회전력을 가했을 때 가장 낮게 나타났다 (P < .05). 4. 하중 후 풀림회전력 상실률은 SS II, GS II, 그리고 US II 순으로 높아지는 경향을 보였다. 5. 초기 풀림회전력과 하중 후 풀림회전력 상실률 간에는 상관관계가 없었다 (P > .05). 이상의 결과로부터 임플랜트 시스템의 종류뿐만 아니라 조임회전력의 크기 또한 지대주 나사의 풀림회전력 상실에 영향을 준다는 것을 알 수 있다. 따라서 임플랜트-지대주 나사 연결부 안정성 유지를 위해서는 임플랜트 시스템마다 적정 조임회전력이 제시되어야 하고, 또한 임상에서 이를 준수하는 것이 매우 중요하다고 생각된다.

절리 지반에서 2단계로 굴착되는 터널의 거동특성에 대한 실험적연구 (An experimental study on the behavior of tunnel excavated in a jointed mass by two-stage excavation)

  • 박승준;김동갑;이상덕
    • 한국터널지하공간학회 논문집
    • /
    • 제6권4호
    • /
    • pp.303-314
    • /
    • 2004
  • 본 연구에서는 터널을 굴착할 때 절리가 있는 암반의 역학적 거동특성을 실험적으로 규명하고자 하였다. 절리와 터널의 이격거리, 측압계수를 변화시키며 실험을 수행하였다. 터널주변에 수직절리가 있는 경우 천단부와 수직절리 반대편의 어깨부에서 가장 큰 영향이 발생되며 측압이 작을 경우에는 천단부 보다 절리 반대편 측벽부에서 접선 방향의 응력이 크게 증가된다. 반면 $45^{\circ}$의 경사절리가 있는 경우 발생하는 압축응력은 절리면 방향의 터널 좌측부가 무절리 상태의 3배정도로 터널의 안정성에 큰 영향을 미치는 것으로 나타났다.

  • PDF

외상 후 파괴된 주관절 또는 진구성 탈구에서의 주관절 전치환술 (Total elbow arthroplasty for posttraumatic destroyed or unreduced elbow joint)

  • 김영규;정이혁
    • Clinics in Shoulder and Elbow
    • /
    • 제6권1호
    • /
    • pp.37-43
    • /
    • 2003
  • Purpose: To evaluate the results in patients who received total elbow replacement for posttraumatic destroyed or unreduced elbow joint. Materials and Methods: Six patients with posttraumatic destroyed, or unreduced elbow joint, who were nearly impossible to move actively and had pain and grossly unstable joint, were followed up average 42 months. 3 cases were soft tissue injuries and bone defects which were caused by severe comminuted fracture, 1 was a nonunion with comminuted fracture, and 2 were unreduced elbow joint. Total elbow replacement was performed average 10 months after the injury. All the cases were used by semiconstrained prosthesis, and the results were estimated by Mayo elbow perfomance score. Results: Pain was decreased in all the cases postoperatively. Average ranges of motion were improved with active extension 20° and flexion 120°. Mayo elbow performance scores were pain 42.5 points, range of motion 17.5 points, stability 8.3 points, function 19.2 points and totally 87.5 points, and final results were 3 excellent and 3 good. Loosening of prosthesis was not found in all the cases by final follow-up radiograph. Conclusicon: Semiconstrained TER can be used as a effective treatment improving pain and active ranges of motion caused by posttraumatic destroyed or unreduced elbow joint, however, long term follow-up is needed because early loosening of TER can be occurred due to severe bone defects.

태권도 주춤서기 후 앞꼬아서기 옆차기의 운동학적 분석 (A Kinematic Analysis of Taekwondo Juchumseogi hu Apkkoaseogi yeopchagi)

  • 허보섭;이효택;이정기;김용재
    • 수산해양교육연구
    • /
    • 제26권3호
    • /
    • pp.535-542
    • /
    • 2014
  • The purpose of this study was to analyze the movements of the lower extremity joints during a taekwondo kick motion called 'Juchumseogi hu Apkkoaseogi yeopchagi', which was administered to players to improve their balance, stability, and range of motion for the prevention of injuries. Eight professional players and amateur players were recruited as the subjects. Kinematic data were collected by four real-time infrared cameras. The hip joint, knee joint, and ankle joint angles were measured using instruments. During the 'Juchumseogi hu Apkkoaseogi yeopchagi' kick motion, there were small and inconsistent effects on each joint. This study processed the data using the Windows SPSS Ver. 18.0 to get an independent t-test, with the setting, p< .05. Results indicated that hip joint, knee joint, and ankle joint angles were almost significantly different between professional and amateur player during 'Juchumseogi hu apgeule Apkkoaseogi' kick motion.