• Title/Summary/Keyword: joint resistance

Search Result 571, Processing Time 0.026 seconds

Limitation of Nitrogen ion Implantation and Ionplating Techniques Applied for Improvement of Wear Resistance of Metallic Implant Materials (금속 임플란트 소재의 내마모성 향상을 위하여 적용되는 질소 이온주입 및 이온도금법의 한계)

  • 김철생
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.157-163
    • /
    • 2004
  • Nitrogen ion implantation and ion plating techniques were applied for improvement of the wear resistance of metallic implant materials. In this work, the wear dissolution behaviour of a nitrogen ion implanted super stainless steel (S.S.S, 22Cr-20Ni-6Mo-0.25N) was compared with those of S.S.S, 316L SS and TiN coated 316L SS. The amounts of Cr and Ni ions worn-out from the specimens were Investigated using an electrothermal atomic absorption spectrometry. Furthermore, the Ti(Grade 2) disks were coated with TiN, ZrN and TiCN by use of low temperature arc vapor deposition and the wear resistance of the coating layers was compared with that of titanium. The chemical compositions of the nitrogen ion implanted and nitride coated layers were examined with a scanting auger electron spectroscopy. It wat observed that the metal ions released from the nitrogen ion implanted S.S.S surface were significantly reduced. From the results obtained, it was shown that the nitrogen ion implanted zone obtained with 100 KeV ion energy was easily removed within 200,000 revolutions from a wear dissolution testing under a similar load condition when applied to artificial hip joint. The remarkable improvement in wear resistance weir confirmed by the nitrides coated Ti materials and the wear properties differ greatly according to the chemical composition of the coating layers. for specimens with the same coating thickness of about 3$\mu\textrm{m}$, TiCN coated Ti showed the highest wear resistance. However, after removing the coating layers, the wear rates of all nitrides coated Ti reverted to their normal rates of below 10,000 revolutions from Ti-disk-on-disk wear testing under the same load condition. From the results obtained, it is suggested that the insufficient depth of the 100 Kel N$\^$+/ ion implanted zone and of the nitrides coated layers of 3$\mu\textrm{m}$ are subject to restriction when used as frictional parts of load bearing implants.

The Etiology and Clinical Features of Acute Osteoarthritis in Children; 2003-2009 (최근 6년간 소아청소년기 급성 화농성 골관절염의 원인균과 임상 양상; 2003-2009)

  • Choi, Jin Hyoung;Choe, Young June;Hong, Ki Bae;Lee, Jina;Yoo, Won Joon;Kim, Han Soo;Park, Moon Seok;Cho, Tae Joon;Chung, Chin Youb;Lee, Hoan Jong;Choi, In Ho;Choi, Eun Hwa
    • Pediatric Infection and Vaccine
    • /
    • v.18 no.1
    • /
    • pp.31-39
    • /
    • 2011
  • Purpose : This study was performed for the purpose of finding causative organisms and clinical features of septic arthritis or acute osteomyelitis in children. Methods : The study involved a retrospective review of the medical records of 63 microbiologically confirmed cases of acute pyogenic arthritis and osteomyelitis. All of the cases were brought about by community-associated infections and managed at the Seoul National University Children's Hospital or Seoul National University Bundang Hospital from June 2003 to July 2009. Results : The median age of all cases was 60 months and there were 35 males and 28 females. Major involved joints included the hip joint (15 cases), knee joint (7 cases), shoulder joint (4 cases), and elbow joint (4 cases). Also, major involved bones included the femur (20 cases), tibia (13 cases), humerus (7 cases), and radius (7 cases). Staphylococcus aureus was the most commonly identified causative organism, accounting for 49 cases (77.8%). Of the 49 isolates of S. aureus, methicillin-resistant S. aureus (MRSA) accounted for 8 cases (16.3%). Group B streptococcus spp. (GBS) and Salmonella spp. accounted for 3 cases, respectively. Nafcillin or cefazolin was often prescribed as an initial empirical antibiotic. There were 9 cases that were managed by a regimen that included vancomycin as the first choice. Fifty four cases (85.7%) recovered without any complications. Methicillin-sensitive S. aureus (MSSA), responsible for 41 cases, caused chronic complications in 3 cases. Of 8 cases caused by MRSA, 1 case showed chronic complication. There were no fatal cases. Conclusion : S. aureus remains the most common organism causing acute pyogenic arthritis and osteomyelitis of childhood acquired in the community. The high prevalence of methicillin resistance among S. aureus should be considered carefully in the selection of initial empirical antibiotics.

Analysis Model for Approximate Evaluation of Stiffness for Semi-Rigid Connection of Wooden Structures (목조 구조물 접합부의 강성에 대한 근사평가를 위한 해석모델)

  • Cho, So-Hoon;Lee, Heon-Woo;Park, Moon-Jae;Kim, Taejin;Kim, Jong-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.1
    • /
    • pp.93-100
    • /
    • 2015
  • Modern wooden structures usually are connected with steel fastener type connectors. And joints using multiple connectors in wooden structures will form semi-rigid connection. If connection in wooden structure would be designed to be pinned joint, the underestimate for loads transmitted through connection, would result in the deficient capacity of resistance in connection. And if joints in wooden structures would be assumed to be fully-rigid joint, amount of fasteners needed at the connection could be excessively increased. It will give a bad effect in the view of beauty, constructability and economy. Estimate for the reasonable stiffness of connection might be essential in design of reasonable connection in wooden structure. This paper will suggest analysis modelling technique that can represent approximate stiffness of connections using a common analysis program for double shear connection in order to give help in performing easily the design of wooden structure. It is verified that the suggested approximate analysis modelling technique could represent the behavior in connection by comparing the analysis results with test results for tensile, bending moment.

The Effect of Exercise Intensity on Muscle Activity and Kinematic Variables of the Lower Extremity during Squat

  • Jung, Jae-Hu;Chae, Woen-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.3
    • /
    • pp.197-203
    • /
    • 2017
  • Objective: The purpose of this study was to determine how exercise intensity affects muscle activity and kinematic variables during squat. Method: Fifteen trainers with >5 years of experience were recruited. For the electromyography (EMG) measurements, four surface electrodes were attached to both sides of the lower extremity to monitor the rectus femoris (RF) and biceps femoris. Three digital camcorders were used to obtain three-dimensional kinematics of the body. Each subject performed a squat in different conditions (40% one-repetition maximum [40%1RM], 60%1RM, and 80%1RM). For each trial being analyzed, three critical instants and two phases were identified from the video recording. For each dependent variable, one-way analysis of variance with repeated measures was used to determine whether there were significant differences among the three different conditions (p<.05). When a significant difference was found, post hoc analyses were performed using the contrast procedure. Results: The results showed that the average integrated EMG values of the RF were significantly greater in 80%1RM than in 40%1RM during the extension phase. The temporal parameter was significantly longer in 80%1RM than in 40%1RM and 60%1RM during the extension phase. The joint angle of the knee was significantly greater in 80%1RM than in 40%1RM at flexion. The range of motion of the knee was significantly less in 80%1RM than in 40%1RM and 60%1RM during the flexion phase and the extension phase. The angular velocity was significantly less in 80%1RM than in 40%1RM and 60%1RM during the extension phase. Conclusion: Generally, the increase of muscle strength decreases the pace of motion based on the relation between the strength and speed of muscle. In this study, we also found that the increase of exercise intensity may contribute to the increase of the muscle activity of the RF and the running time in the extension phase during squat motion. We observed that increased exercise intensity may hinder the regulation of the range of motion and joint angle. It is suitable to perform consistent movements while controlling the proper range of motion to maximize the benefit of resistance training.

Development of Multi-rotational Prosthetic Foot for Lower Limb Amputee (하지 절단자를 위한 다축 회전이 가능한 인공발의 개발)

  • Shin, Hyunjun;Park, Jin-Kuk;Cho, Hyeon-Seok;Ryu, Jei-Cheong;Kim, Shin-Ki
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.4
    • /
    • pp.305-313
    • /
    • 2016
  • Movements of the lower limb are important for normal walking and smooth oscillation of the center of gravity. The ankle rotations such as dorsi-flexion, plantar-flexion, inversion and eversion allows the foot to accommodate to ground during level ground walking. Current below knee (B/K) prostheses are used for replacing amputated ankle, and make it possible for amputees to walk again. However, most of amputees with B/K prostheses often experience a loss of terrain adaptability as well as stability because of limited ankle rotation. This study is focused on the development of multi-rotational prosthetic foot for lower limb amputee. Our prosthesis is possible for amputees to easily walk in level ground by rotating ankle joint in sagittal plane and adapt to the abnormal terrain with ankle rotation in coronal plane. The resistance of ankle joint in the direction of dorsi/plantar-flexion can be manually regulated by hydraulic damper with controllable nozzle. Furthermore, double layered rubber induce the prosthesis adapt to irregular ground by tilting itself in direction of eversion and inversion. The experimental results highlights the potential that our prosthesis induce a normal gait for below knee amputee.

Experimental Study on the Behavior of Building Hardware with Joint Details (접합 방법에 따른 하지철물 구조물의 거동에 관한 실험적 연구)

  • Hong, Seonguk;Kim, Seunghun;Baek, Kiyoul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.190-198
    • /
    • 2018
  • In recent years, non-welded building hardware has been installed by bolt assembly is used. The non-welded building hardware method can reduce accidents caused by welding, and can be constructed by bolt assembly, which can reduce labor costs and shorten the construction period. However, there is a need for a method to compensate for the occurrence of buckling at the time of construction. The purpose of this study is to evaluate the behavior of joints between steel pipe and fastener and to evaluate the behavior of joints of non-welded and welded hardware frame. As a result, it was found that the foundation steel structure without welded joints was deformed to a rotation angle of member much larger than the allowable interlayer displacement angle 0.01 to 0.02 required according to the seismic load rating in the seismic load resistance system.

Effect of the Hip Joint Adduction on Walking During the Plank Exercise (엉덩관절모음과 플랭크운동이 보행에 미치는 영향)

  • Mun, Dal Ju;Park, Jae Cheol;Choi, Seck Joo
    • Korean Educational Research Journal
    • /
    • v.40 no.3
    • /
    • pp.67-84
    • /
    • 2019
  • The purpose of this study is to see how the stability of posture due to elastic band during plank movement affects walking. Thirty healthy men in their 20s were given a total of 30 minutes of 10 general plank exercises, 10 plank exercises with two hip joints adduction, and 10 plank exercises with one hip joint adduction. The plank movement was conducted three times a week for a total of six weeks, with a five-minute warm-up. The results of this study are as follows: There was a significant difference between period and group interactions on cadence (p<0.05), with significant difference between the period and group between the left foot on stride length of the left side foot (p<0.05), with significant difference between the period and the period of the interaction between the right foot and the period on stride length of the right side foot (p<0.05), and a one-step change between the right foot and the military interaction on Step time of the right side foot(p<0.05). The conclusion of this study is that the resistance movement on the adduction of both hips increases the instability of the trunk over the normal plank movement and adduction of one hip, thereby enhancing walking ability along with the stability of the trunk.

  • PDF

Study of Spectral Doppler Waveform Interpretation and Nomenclature in Peripheral Artery (말초 동맥 분광 도플러 파형 해석 및 명명법에 대한 고찰)

  • Ji, Myeong-Hoon;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.649-660
    • /
    • 2022
  • In 1959, Satomura used spectral Doppler ultrasound to express the velocity of red blood cells according to time change, and Kato defined a zero-base line that could tell the direction of blood flow, making it possible to know the direction of blood flow. This became the basis for the widely used classifications of Triphasic, Biphasic, and Monophasic. However, the above classification has limitations that confuse users with the meaning and timing of use in a clinical environment. As a result, the American Society for Vascular Medicine (SVM) and the Society for Vascular Ultrasound (SVU) A consensus document on Doppler waveform analysis was declared by the joint committee. This study tried to review this consensus and to suggest nomenclature and modifiers that can be used in the domestic vascular ultrasound clinical field. The joint committee formed by SVM and SVU recommended that the use of the triphasic waveform and the biphasic waveform be used as a multiphasic waveform rather than being used due to the ambiguity of interpretation. In addition, it was agreed to name the hybrid-type waveform, which is a monophasic and high-resistance waveform, which has always been a problem of interpretation in a clinical environment, as an intermediate resistive waveform. In addition, in order to increase the communication efficiency between the interpreter and the sonographer, waveform analysis was classified into a main descriptor and a modifier, and it was recommended to use a single nomenclature by unifying various synonyms. It is expected that this literature review will provide accurate arterial spectral Doppler waveform interpretation and an agreed-upon nomenclature to radiologists performing vascular ultrasound examination in clinical practice, and will be utilized as basic data that can contribute to the improvement of public health.

A Study of Statistic Behavior of Segmental U-shaped Prestressed Concrete Girder Applied with Integrated Tensioning Systems (복합긴장방식이 적용된 세그멘탈 U형 거더 정적 거동 연구)

  • Hyunock Jang;Ilyoung Jang
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.2
    • /
    • pp.329-338
    • /
    • 2024
  • Purpose: This study verified the safety of the improved box-type girder behavior by comparing and evaluating the bending behavior results of a full-scale specimen based on the analytical behavior of the splice element PSC U-shaped girder with integrated tensioning systems. Method: Based on the results of the service and strength limit state design using the bridge design standard(limit state design method), the applied load of a 40m full-scale specimen was calculated and a static loading experiment using the four-point loading method was performed. Result: When the design load, crack load, and ultimate load were applied, the specimen deflection occurred at 97.1%, 98.5%, and 79.0% of the analytical deflection value. When the design load, crack load, and ultimate load were applied, the crack gauge was measured at 0.009~0.035mm, 0.014~0.050mm, and 6.383~5.522mm at each connection. Conclusion: The specimen behaved linear-elastically until the crack load was applied, and after cracks occurred, it showed strainhardening up to the ultimate load, and it was confirmed that the resistance of bending behavior was clearly displayed against the applied load. The cracks in the dry joints were less than 25% of grade B based on the evaluation of facility condition standard. The final residual deformation after removing the ultimate load was 0.114mm, confirming the stable behavior of the segment connection.

Moment Resistance Performance Evaluation of Larch Glulam Joints using GFRP-reinforced Laminated Plate and GFRP Rod (GFRP 보강적층판 및 GFRP rod를 이용한 낙엽송 집성재 접합부의 모멘트저항 성능평가)

  • Jung, Hong-Ju;Song, Yo-Jin;Lee, In-Hwan;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.1
    • /
    • pp.40-47
    • /
    • 2016
  • Instead of metal connector generally used on the structural glued laminated timber rahmen joints, the GFRP reinforced laminated plates combining veneer and GFRP (Glass Fiber Reinforced Plastic) and bonded type GFRP rod were used as the connectors. As a result of moment resistance performance evaluation on the joint part applied with these connectors, the yield moment of specimen using the GFRP reinforced laminated plates and GFRP rod pin was measured 4 % lower in comparison to the specimen (Type-1) using the metal connectors, but the initial rotational stiffness was measured 29% higher. Also, the yield moment and rotational stiffness of the specimen using the GFRP-reinforced laminated plates and wood (Eucalyptus marginata) pin showed were measured 11% and 56% higher in comparison to the Type-1 specimen, showing the best performance. It was also confirmed through the failure shape and perfect elasto-plasticity analysis that it showed ductility behavior, not brittle fracture, from the shear resisting force by the pin and the bonding strength increased and the unification of member was carried out. On the other hand, in case of the specimen bonded with GFRP rod, it was impossible to measure the bonding performance or it was measured very low due to poor bonding.