• 제목/요약/키워드: isotope measurement

검색결과 131건 처리시간 0.023초

Quantification of $Cu(In_xGa_{1-x})Se_2$ Solar Cell by SIMS

  • Jang, Jong-Shik;Hwang, Hye-Hyen;Kang, Hee-Jae;Min, Hyung-Sik;Han, Myung-Sub;Suh, Jung-Ki;Cho, Kyung-Haeng;Chung, Yong-Duck;Kim, Je-Ha;Kim, Kyung-Joong
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.275-275
    • /
    • 2012
  • The relative composition of $Cu(InGa)Se_2$ solar cells is one of the most important measurement issues. However, quantitative analysis of multi-component alloy films is difficult by surface analysis methods due to severe matrix effect. In this study, quantitative depth profiling analysis of CIGS films was investigated by secondary ion mass spectrometry (SIMS). The compositions were measured by SIMS using the alloy reference relative sensitivity factors derived from the certified compositions and the total counting numbers of each element. The compositions measured by SIMS were linearly proportional to those by inductively coupled plasma-mass spectrometry (ICP-MS) using isotope dilution method. In this study, the quantification measured by ICP-MS method is compared with the composition calculated by SIMS depth profiles with AR-RSFs obtained from the reference. The SIMS depth profile of CIGS thin films according to the manufacturing condition was converted into compositional depth profile.

  • PDF

DESIGN OF LSDS FOR ISOTOPIC FISSILE ASSAY IN SPENT FUEL

  • Lee, Yongdeok;Park, Chang Je;Kim, Ho-Dong;Song, Kee Chan
    • Nuclear Engineering and Technology
    • /
    • 제45권7호
    • /
    • pp.921-928
    • /
    • 2013
  • A future nuclear energy system is being developed at Korea Atomic Energy Research Institute (KAERI), the system involves a Sodium Fast Reactor (SFR) linked with the pyro-process. The pyro-process produces a source material to fabricate a SFR fuel rod. Therefore, an isotopic fissile content assay is very important for fuel rod safety and SFR economics. A new technology for an analysis of isotopic fissile content has been proposed using a lead slowing down spectrometer (LSDS). The new technology has several features for a fissile analysis from spent fuel: direct isotopic fissile assay, no background interference, and no requirement from burnup history information. Several calculations were done on the designed spectrometer geometry: detection sensitivity, neutron energy spectrum analysis, neutron fission characteristics, self shielding analysis, and neutron production mechanism. The spectrum was well organized even at low neutron energy and the threshold fission chamber was a proper choice to get prompt fast fission neutrons. The characteristic fission signature was obtained in slowing down neutron energy from each fissile isotope. Another application of LSDS is for an optimum design of the spent fuel storage, maximization of the burnup credit and provision of the burnup code correction factor. Additionally, an isotopic fissile content assay will contribute to an increase in transparency and credibility for the utilization of spent fuel nuclear material, as internationally demanded.

원전 내 사용후핵연료 연소도 측정을 위한 중성자 검출기의 성능 평가 연구 (A Study on Performance Characteristics of Neutron Detector to Measure the Burnup Profile of Spent Fuel in NPP)

  • 박혜민;김태영;이인호;장대헌;송양수;이운장;함철민
    • 방사선산업학회지
    • /
    • 제17권3호
    • /
    • pp.293-297
    • /
    • 2023
  • The burnup profile of spent fuel should be determined accurately for the safety storage of spent fuel. In this study, a neutron detection system was developed as a part of basic research to analyze the burnup profile of spent fuel, and a performance was evaluated using a radiation source. The prototype of the neutron detection system was based on a 3He proportional chamber. The 3He proportional chamber is often used for neutron measurement and analysis because of its high neutron detection efficiency and simplicity for gamma ray rejection. For quantitative evaluation, tests were conducted using calibrated 252Cf and 137Cs sources. In the performance evaluation, a field applicability was verified by analyzing the detection characteristics according to the nuclide.

Radioisotope identification using sparse representation with dictionary learning approach for an environmental radiation monitoring system

  • Kim, Junhyeok;Lee, Daehee;Kim, Jinhwan;Kim, Giyoon;Hwang, Jisung;Kim, Wonku;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • 제54권3호
    • /
    • pp.1037-1048
    • /
    • 2022
  • A radioactive isotope identification algorithm is a prerequisite for a low-resolution scintillation detector applied to an unmanned radiation monitoring system. In this paper, a sparse representation with dictionary learning approach is proposed and applied to plastic gamma-ray spectra. Label-consistent K-SVD was used to learn a discriminative dictionary for the spectra corresponding to a mixture of four isotopes (133Ba, 22Na, 137Cs, and 60Co). A Monte Carlo simulation was employed to produce the simulated data as learning samples. Experimental measurement was conducted to obtain practical spectra. After determining the hyper parameters, two dictionaries tailored to the learning samples were tested by varying with the source position and the measurement time. They achieved average accuracies of 97.6% and 98.0% for all testing spectra. The average accuracy of each dictionary was above 96% for spectra measured over 2 s. They also showed acceptable performance when the spectra were artificially shifted. Thus, the proposed method could be useful for identifying radioisotopes in gamma-ray spectra from a plastic scintillation detector even when a dictionary is adapted to only simulated data. Furthermore, owing to the outstanding properties of sparse representation, the proposed approach can easily be built into an insitu monitoring system.

고압 유체 시료의 pH 및 알칼리도 측정 방법 : 가상 시료를 활용한 실용성 평가 (Method for Measuring pH and Alkalinity of High-Pressure Fluid Samples : Evaluation through Artificial Samples)

  • 송민석;문수현;채기탁;방준환
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제29권1호
    • /
    • pp.1-9
    • /
    • 2024
  • As part of monitoring technology aimed at verifying the stability of CO2 geologic storage and mitigating concerns about leakage, a method for measuring the pH and alkalinity of high-pressure fluid samples was established to obtain practical technology. pH measurement for high-pressure samples utilized a high-pressure pH electrode, and alkalinity was measured using the Gran titration method for samples collected with a piston cylinder sampler (PCS). Experimental samples, referencing CO2-rich water and CO2 geologic storage studies, were prepared in the laboratory. The PCS controls the piston, preventing CO2 degassing and maintaining fluid pressure, allowing mixing with KOH to fix dissolved CO2. Results showed a 6.1% average error in high-pressure pH measurement. PCS use for sample collection maintained pressure, preventing CO2 degassing. However, PCS-collected sample alkalinity measurements had larger errors than non-PCS measurements, limiting PCS practicality in monitoring field settings. Nevertheless, PCS could find utility in preprocessing for carbon isotope analysis and other applications. This research not only contributes to the field of CCS monitoring but also suggests potential applications in studies related to natural analogs of CCS, CO2-rock interaction experiments, core flooding experiments, and beyond.

Effects of Non-protein Energy Intake on Whole Body Protein Synthesis, Nitrogen Retention and Glucose Turnover in Goats

  • Fujita, Tadahisa;Kajita, Masahiro;Sano, Hiroaki
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제20권4호
    • /
    • pp.536-542
    • /
    • 2007
  • The responses of whole body protein and glucose kinetics and of nitrogen (N) metabolism to non-protein energy intake (NPEI) were determined using an isotope dilution approach and measurement of N balance in three adult male goats. The diets containing 1.0, 1.5 and 2.0 times ME maintenance requirement, with fixed intake of CP (1.5 times maintenance) and percentage of hay (33%), were fed twice daily for each 21 d experimental period. After an adaptation period of 11 d, N balance was determined over 3 d. On day 17, whole body protein synthesis (WBPS) and glucose irreversible loss rate (ILR) were determined during the absorptive state by a primed-continuous infusion of [$^2H_5$]phenylalanine, [$^2H_2$]tyrosine, [$^2H_4$]tyrosine and [$^{13}C_6$]glucose, with simultaneous measurements of plasma concentrations of metabolites and insulin. Ruminal characteristics were also measured at 6 h after feeding over 3 d. Nitrogen retention tended to increase (p<0.10) with increasing NPEI, although digestible N decreased linearly (p<0.05). Increasing NPEI decreased (p<0.01) ammonia N concentration, but increased acetate (p<0.05) and propionate (p<0.05) concentrations in the rumen. Despite decreased plasma urea N concentration (p<0.01), increased plasma tyrosine concentration (p<0.05), and trends toward increased plasma total amino N (p<0.10) and phenylalanine concentrations (p<0.10) were found in response to increasing NPEI. Increasing NPEI increased ILR of both glucose (p<0.01) and phenylalanine (p<0.05), but did not affect ($p{\geq}0.10$) that of tyrosine. Whole body protein synthesis increased (p<0.05) in response to increasing NPEI, resulting from increased utilization rate for protein synthesis (p<0.05) and unchanged hydroxylation rate of phenylalanine ($p{\geq}0.10$). These results suggest that increasing NPEI may enhance WBPS and glucose turnover at the absorptive state and improve the efficiency of digestible N retention in goats, with possibly decreased ammonia and increased amino acid absorption. In addition, simultaneous increases in WBPS and glucose ILR suggest stimulatory effect of glucose availability on WBPS, especially when sufficient amino acid is supplied.

동위원소희석 ICP-MS분석법에 의한 남극 세종기지 주변 토양의 중금속 측정 (Measurement of heavy metals in antarctic soil at the king sejong station: application of isotope dilution inductively coupled plasma mass spectrometry)

  • 서정기;황의진;민형식
    • 분석과학
    • /
    • 제21권5호
    • /
    • pp.364-374
    • /
    • 2008
  • 2000년도에 COMNAP/SCAR에 의해 극지지역의 환경모니터링에 관한 표준기술지침서인 'Antarctic Environmental Monitoring Handbook'이 발간되었다. 이 지침서에 따라 남극세종기지주변지역의 토양시료중의 중금속을 분석하였다. 시료분해방법은 고압산분해 방법을 사용하였고, 분석방법으로는 동위원소희석 유도결합플라스마질량분석법을 사용하여 토양중의 Pb, Cu, Zn 성분을 분석하였다. 분석방법의 정확성을 확인하기 위해 표준시료인 NIST 2702를 분석한 결과 인증값의 99.5~100.8% 범위내에서 일치하였다. Chelex 100 이온교환수지를 사용하여 간섭이온을 제거하기 위해 매질을 분리하였다. 측정결과 인위적오염이 예상되는 기지주변지역의 중금속의 평균농도는 각각 Pb 332.9 mg/kg, Cu 95.6 mg/kg, Zn 115.3 mg/kg로 나타났으며, 기지에서 멀리 떨어진 지역의 평균농도는 각각 Pb 28.1 mg/kg, Cu 101.8 mg/kg, Zn 115.6 mg/kg로 나타났다. Pb 농도는 기지주변지역과 멀리 떨어진 지점에서 현저한 차이를 보였다.

열 이온화 질량분석기를 이용한 보론 동위원소 비 측정연구 (Study in the Measurement of Boron Isotopes by Thermal Ionization Mass Spectrometer)

  • 전영신;조기수;한선호;박용준;지광용
    • 분석과학
    • /
    • 제18권1호
    • /
    • pp.27-34
    • /
    • 2005
  • 보론 동위원소 표준물을 이용하여 $Li_2B_4O_7$$Na_2B_4O_7$를 합성하고 이로부터 $Li_2BO_2{^+}$ (질량 56, 57)와 $Na_2BO_2{^+}$ (질량 88, 89)를 열 이온화 질량분석기를 이용하여 양이온 질량분석법(PTIMS)으로 측정하였으며 또한 같은 시료를 음이온 질량분석법 (NTIMS)으로 $^{10}BO_2{^-}$$^{11}BO_2{^-}$ (질량 42와 43)를 보론 (질량 10, 11)대신 측정하였다. 이들 방법 간의 정밀도와 정확도를 비교하고, 각각의 방법에서 동중원소 영향이 있는지를 알아보았다. 세 가지 방법 중에 NTIMS 방법이 제일 좋은 결과를 보여주었으며 작은 시료 양으로도 안정된 피크를 얻을 수 있었다. NTIMS 방법으로 지하수 약 $5{\mu}L$(약 8 ng-B)를 직접시료로 사용하여 보론 동위원소 비를 측정하여 상대 표준편차 0.03%의 결과를 얻었다. 또한 NTIMS-IDMS로 보론을 정량한 결과 $1.65{\pm}0.003{\mu}g-B/mL$을 얻었으며 ICP-AES 결과에 비해 좋은 정밀도를 보였다.

의료용 방사성폐기물 자체처분을 위한 방사능 측정 및 평가 (Measurement and Estimation for the Clearance of Radioactive Waste Contaminated with Radioisotopes for Medical Application)

  • 김창범;박민석;김기섭;정해조;장성주
    • 한국의학물리학회지:의학물리
    • /
    • 제25권1호
    • /
    • pp.8-14
    • /
    • 2014
  • 의료분야에서 방사선 진료기술의 발전에 따라 방사성폐기물의 수량은 급속히 증가하고 있다. 방사성폐기물에는 주로 PET/CT에 사용하는 $^{18}F$을 비롯하여 핵의학검사에 사용하는 $^{99m}Tc$ 등과 같이 반감기가 매우 짧은 방사성동위원소가 함유되어 있다. 이를 처분하기 위하여 국제원자력기구(IAEA)는 개인선량($10{\mu}Sv/y$) 및 집단선량(1 man-Sv/y)과 핵종별 농도에 근거하여 각각 폐기물의 규제해제기준을 제시(IAEA Safety Series No 111-P-1.1, 1992 및 IAEA RS-G-1.7, 2004)하였다. 이 연구에서는 IAEA 기준에 따른 방사능농도를 측정하기 위하여, $^{18}F$, $^{99m}Tc$, $^{123}I$, $^{125}I$$^{201}TI$ 관련 방사성폐기물을 수집하고 측정용기를 준비하였다. 그리고 MCA를 이용한 감마방사능 측정, 감마계수기를 이용한 감마방사능 측정, 베타입자 방출 핵종의 방사능 측정방법 및 절차를 수립하고, 표준물질을 제작하여 교정하였다. 측정결과를 근거로 방사능 감쇠 유도식을 산출하였으며, 이를 이론식과 대비하여 고찰하였다. 이 연구 결과는 ISO 표준으로 추진할 예정이다.

열 이온화 질량분석기를 이용한 Ru 동위원소 측정 및 동중원소 영향 보정 (The isobaric effect correction and measurement of the Ru isotopes by thermal ionization mass spectrometry)

  • 전영신;김정석;한선호;송규석
    • 분석과학
    • /
    • 제23권5호
    • /
    • pp.498-504
    • /
    • 2010
  • 열 이온화 질량분석을 이용한 루테늄(Ru) 동위원소 비 측정은 루테늄의 이온화 포텐셜이 높고 산화상태로 휘발이 일어나 시료가 쉽게 소모되어 안정된 이온피크를 얻기가 어렵다. 따라서 이온화 효율을 높이고 안정적 이온생성을 위한 실험과 질량분석에 사용되는 레늄(Re) 필라멘트에 함유된 불순물들에 의한 동중원소 영향을 검토하였다. 질량분석에서 double filament를 사용하는 것 보다는 single filament를 사용하는 것이 더 안정적 이온 피크를 얻을 수 있었을 뿐만 아니라 몰리브데넘(Mo)에 의한 동중원소 영향도 작았다. 또한 필라멘트 온도를 필요이상 높이면 높일수록 동중원소 영향이 큼을 알 수 있었다. 즉, 불순물로 함유된 Mo이 Ru 동위원소 비 측정에 큰 영향을 주었다. 특히 필라멘트 온도를 일정한 시간 간격을 두고 서서히 올려주는 것이 안정된 피크를 얻는데 매우 중요함을 알 수 있었다. Mo으로부터 오는 동중원소 영향을 $^{94}Mo/^{99}Ru$ 비를 측정하여 보정함으로써 Ru 동위원소 비를 정확히 측정할 수 있었다.