• Title/Summary/Keyword: iso

Search Result 5,881, Processing Time 0.034 seconds

Design of Translator for generating Secure Java Bytecode from Thread code of Multithreaded Models (다중스레드 모델의 스레드 코드를 안전한 자바 바이트코드로 변환하기 위한 번역기 설계)

  • 김기태;유원희
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2002.06a
    • /
    • pp.148-155
    • /
    • 2002
  • Multithreaded models improve the efficiency of parallel systems by combining inner parallelism, asynchronous data availability and the locality of von Neumann model. This model executes thread code which is generated by compiler and of which quality is given by the method of generation. But multithreaded models have the demerit that execution model is restricted to a specific platform. On the contrary, Java has the platform independency, so if we can translate from threads code to Java bytecode, we can use the advantages of multithreaded models in many platforms. Java executes Java bytecode which is intermediate language format for Java virtual machine. Java bytecode plays a role of an intermediate language in translator and Java virtual machine work as back-end in translator. But, Java bytecode which is translated from multithreaded models have the demerit that it is not secure. This paper, multhithread code whose feature of platform independent can execute in java virtual machine. We design and implement translator which translate from thread code of multithreaded code to Java bytecode and which check secure problems from Java bytecode.

  • PDF

Comparison of screw-in effect of three NiTi file systems used by undergraduates (학생들이 사용한 세 종류 NiTi file systems의 screw-in effect 비교)

  • Oh, Seung-Hei;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.6
    • /
    • pp.477-484
    • /
    • 2006
  • The purposes of this study were to compare the apical terminus width of simulated curved root canal prepared with three NiTi file systems used by undergraduates for evaluation the effects of flute angle and pitch or radial land on reducing screw-in effect and to determine more safe NiTi file system for inexperienced operators. Fifty inexperienced undergraduate students prepared 150 simulated curved root canals in resin blocks with three NiTi file systems ; ProFile$^{(R)}$, Hero Shaper$^{(R)}$, K3$^{TM}$. The electric motor set at a speed of 300 rpm and torque of 30 in a 16 : 1 reduction handpiece was used. The simulated root canal was prepared to ISO #25 sizes with each file system. The scanned images of pre- and post-instrumented canal of resin block were superimposed. To evaluate the screw-in effect of three NiTi file systems, apical terminus width of root canal was measured from superimposed images and statistical analysis was performed. There were significant differences in three NiTi flle systems. ProFile$^{(R)}$ had significantly smaller width than Hero Shaper$^{(R)}$ and K3$^{TM}$"" (P < 0.05), but no significant difference was observed between K3$^{TM}$ and Hero Shaper$^{(R)}$. Under the condition of this study, active file system (Hero SHaper$^{(R)}$, K3$^{TM}$) with variable pitch and helical angle had more screw-in effect than passive file system (ProFile$^{(R)}$) with constant pitch and helical angle. It seems that the radial lands play more important role in reducing screw-in effect.

MICROLEAKAGE OF THE CLASS V CAVITY ACCORDING TO RESTORATION SITE AND CAVITY SIZE USING SEM AND THREE-DIMENSIONAL RECONSTRUCTION TECHNIQUES (SEM과 3차원 재구성법을 이용한 수복면의 위치와 와동 크기에 따른 미세누출도 분석)

  • Yang, In-Seo;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.2
    • /
    • pp.112-120
    • /
    • 2005
  • This study was done to evaluate whether there were any differences in microleakage of class V composite restorations according to restoration site and cavity size. Total sixty-four restorations were made in molar teeth using Esthet-X. Small ($2\;{\times}\;2\;{\times}\;1.5\;mm$) and large ($4{\times}2{\times}1.5\;mm$) restorations were made at the buccal/lingual surface and the proximal surface each. After 1,000 times of thermocycling ($5^{\circ}\;-\;55^{\circ}C$), resin replica was made and the percentage of marginal gap to the whole periphery of the restoration was estimated from SEM evaluation. Thermocycled tooth was dye penetrated with $50\%$ silver nitrate solution. After imbedding in an auto-curing resin, it was serially ground with a thickness of 0.25 mm. Volumetric microleakage was estimated after reconstructing three dimensionally. Two-way ANOVA and independent T-test for dye volume, Mann-Whitney U test for the percentage of marginal gap, Spearman's rho test for the relationship between two techniques were used, The results were as follows : 1. The site and size of the restoration affected on the microleakage of restoration. Namely, much more leakage was seen in the proximal and the large restorations rather than the buccal/lingual and the small restorations. 2. Close relationship was found between two techniques (Correlation coefficient = 0.614/ P = 0.000). Within the limits of this study, it was noted that proximal and the large restorations leaked more than buccal/lingual and the small restorations. Therefore, it should be strictly recommended large exposure of margins should be avoided by reducing unnecessary tooth reduction.

Registration and Description of Public Records in Korea : A Comparative Analysis of Korean Recordskeeping System with the International Standards (한국의 기록물 둥록 및 기술에 대한 기록관리적 접근)

  • Si, Kwi-Sun
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.3 no.1
    • /
    • pp.69-92
    • /
    • 2003
  • Registration and description of records are important elements of processing which provide with the background information of production of records and business-related information. They also enable to search and use the records. In this paper, I examined the Korean registration and description system defined in the Public Records Management Act which directs the records creating agency to register records in creating offices and directs the "professional archives" to make "basic registrations" and "detailed registrations" of the records. In the analysis and comparison of two different registration and description systems with the known international standards of records and archives management, such as ISO15489 and ISAD(G), I intended to evaluate the Korean records and archives management system and suggested recommendations for the renovation of the Korean recordskeeping system. Despite we have unique office business procedures and the culture of officialdom, and despite we have developed our system based on the established business procedures and office culture, it would be preferable to adopt or follow the international standards and established best practices. After the comparative analysis, I recommended some innovations in the filed of registration and description. For instance, in the basic registration. we would better to install an item of "simple contents summary." We may also need the multiple-level description. The fonds level description and the series level description should be introduced to our archival automated management system. We need to establish a Korean standard of description adopting the rules of the ISAD(G) and ISAAR(CPF). Essential requirements for electronic records management, such as contextual and structural information, should be incorporated in the new standard. Documentation of records disposition also should be reinforced to guarantee the authenticity of records and to ensure control of the records. To implement the recommendations for the standard, we need to amend the Public Records Management Act and its Regulations and Rules. Also it is imperative to redesign the GARS integrated archival automated management system.

Usefulness of Breath-hold T2-weighted MR Imaging in Patients with Myocardial Infarction: Comparison with Delayed Enhancement (심근경색을 가진 환자에서 호흡정지 T2강조 자기공명영상의 유용성: 지연 조영증강 영상과의 비교)

  • Choi Sang Il;Kang Sung-Kwon;Ryu Won Hee;Lim Cheong;Choh Joong Haeng;Lee Whal;Jeong Jin-Wook;Park Jae-Hyung;Lee Kyung Won
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.132-136
    • /
    • 2003
  • Purpose : To evaluate the usefulness of breath-hold T2-weighted MR imaging in patients with myocardial infarction. Materials and Methods : We investigated 11 patients with myocardial infarction who shown delayed enhancement on MR imaging. Infarcted myocardium on T2-weighted MR imaging was classified as high, iso, and low signal area comparing with normal myocardium. The intensity and transmural extent of infracted myocardium was also analyzed. On the basis of clinical information, the stage of infracted myocardium on T2-weighted MR imaging was assessed. Results : It was observed high signal area in 12 segments of 5 patients, low in 12 segments of 6 patients on T2-weighted MR imaging. The high signal intensity of infarcted myocardium was shown as $175{\pm}9\%$ comparing with that of the normal myocardium, low signal intensity as $73{\pm}5\%\;(p\;<\;0.05)$. In the evaluation of transmural extent, the high signal areas on T2-weighted MR imaging were larger than infarct area on delayed enhancement imaging $(100\%\;vs.49\%{\pm}17\%)$, whereas low signal areas on T2-weighted MR imaging correlated. High signal area was visualized on T2-weighted MR imaging within 11 days, whereas low-signal area was seen after 7 months. Conclusion : Breath-hold T2-weighted MR imaging is useful in the evaluation of stage as well as edema and fibrous scar in patients with myocardial infarction.

  • PDF

Effects of chromium chloride addition on coloration and mechanical properties of 3Y-TZP (크롬염화물 첨가에 따른 지르코니아 색상 및 물리적 성질 변화에 관한 연구)

  • Oh, Gye-Jeong;Seo, Yoon-Jeong;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sang-Won;Lee, Kyung-Ku;Lim, Tae-Kwan;Lee, Doh-Jae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.120-127
    • /
    • 2011
  • Purpose: The purpose of this study was to examine the effects of chromium chloride addition on coloration, mechanical property and microstructure of 3Y-TZP. Materials and methods: Chromium chloride was weighed as 0.06, 0.12, and 0.25 wt% and each measured amount was dissolved in alcohol. $ZrO_2$ powder was mixed with each of the individual slurry to prepare chromium doped zirconia specimen. The color, physical properties and microstructure were observed after the zirconia specimen were sintered at $1450^{\circ}C$. In order to evaluate the color, spectrophotometer was used to analyze the value of $L^*$, $C^*$, $a^*$ and $b^*$, after placing the specimen on a white plate, and measured according to the International Commission on Illumination (CIE) standard, Illuminant D65 and SCE system. The density was measured in the Archimedes method, while microstructures were evaluated by using the scanning electron microscopy (SEM) and XRD. Fracture toughness was calculated Vickers indentation method and indentation size was measured by using the optical microscope. The data were analyzed with 1-way ANOVA test (${\alpha}$ = 0.05). The Tukey multiple comparison test was used for post hocanalysis. Results: 1. Chromium chloride rendered zirconia a brownish color. While chromium chloride content was increased, the color of zirconia was changed from brownish to brownish-red. 2. Chromium chloride content was increased; density of the specimen was decreased. 3. More chromium chloride in the ratio showed increase size of grains. 4. But the addition of chromium chloride did not affect the crystal phase of zirconia, and all specimens showed tetragonal phase. 5. The chromium chloride in zirconia did not showed statistically significant difference in fracture toughness, but addition of 0.25 wt% showed a statistically significant difference (P<.05). Conclusion: Based on the above results, this study suggests that chromium chlorides can make colored zirconia while adding in a liquid form. The new colored zirconia showed a slight difference in color to that of the natural tooth, nevertheless this material can be used as an all ceramic core material.

Evaluation of retrievability using a new soft resin based root canal filling material (레진 계통의 근관 충전재의 제거 용이성에 대한 평가)

  • Shin Su-Jung;Lee Yoon;Park Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.4
    • /
    • pp.323-329
    • /
    • 2006
  • The aim of this study was to evaluate the retrievability of Resilon as a root canal filling material Twenty-seven human single-rooted extracted teeth were instrumented utilizing a crown down technique with Gates-Glidden burs and ProFile system. In group1 (n = 12) canals were obturated with gutta percha and AH-26 plus sealer using a continuous wave technique and backfilled. In group 2 (n = 15) Resilon was used as a filling material. Then teeth were sealed and kept in $37^{\circ}C$ and 100% humidity for 7 days. For retreatment, the samples were re-accessed and filling material was removed using Gates-Glidden burs and ProFiles. Teeth were sectioned longitudinally to compare the general cleanliness and amount of debris $({\times}\;75)$ using SEM. Chi-square test was used $({\alpha}\;=\;0.05)$ to analyze the data. The total time required for removal of filling materials was expressed as mean ${\pm}SD$ (min) and analyzed by the Student t-test $({\alpha}\;=\;0.05)$, Required time for retreatment was $3.25\;{\pm}\;0.32$ minutes for gutta percha/ AH 26 plus sealer and $3.05\;{\pm}\;0.34$ minutes for Resilon. There was no statistically significant difference between the two experimental groups. There was no significant difference between the groups in the cleanliness of the root canal wall. This study showed that Resilon was effectively removed by Gates-Glidden burs and ProFiles.

Human Thermal Sensation and Comfort of Beach Areas in Summer - Woljeong-ri Beach, Gujwa-eup, Jeju-si, Jeju Special Self-Governing Province - (여름철 해변지역의 인간 열환경지수 및 열쾌적성 - 제주특별자치도 제주시 구좌읍 월정리 해변 -)

  • Park, Sookuk;Sin, Jihwan;Jo, Sangman;Hyun, Cheolji;Kang, Hoon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.4
    • /
    • pp.100-108
    • /
    • 2016
  • The climatic index for tourism(CIT) has recently been advanced, which includes complete human energy balance models such as physiological equivalent temperature(PET) and universal thermal climate index(UTCI). This study investigated human thermal sensation and comfort at Woljung-ri Beach, Jeju, Republic of Korea, in spring and summer 2015 for landscape planning and design in beach areas. Microclimatic data measurements and human thermal sensation/comfort surveys from ISO 10551 were conducted together. There were 869 adults that participated. As a result, perceptual and thermal preference that consider only physiological aspects had high coefficients of determination($r^2$) with PET in linear regression analyses: 92.8% and 87.6%, respectively. However, affective evaluation, personal acceptability and personal tolerance, which consider both physiological and psychological aspects, had low $r^2s$: 60.0%, 21.1% and 46.4%, respectively. However, the correlations between them and PET were all significant at the 0.01 level. The neutral PET range in perceptual for human thermal sensation was $25{\sim}27^{\circ}C$, but a PET range less or equal to 20% dissatisfaction, which was recommended by ASHRAE Standard 55, could not be achieved in perceptual. Only PET ranges in affective evaluation and personal tolerance affected by both aspects were qualified for the recommendation as $21{\sim}32^{\circ}C$ and $17{\sim}37^{\circ}C$, respectively. Therefore, the PET range of $21{\sim}32^{\circ}C$ is recommended to be used for the human thermal comfort zone of beach areas in landscape planning and design as well as tourism and recreational planning. PET heat stress level ranges on the beach were $2{\sim}5^{\circ}C$ higher than those in inland urban areas of the Republic of Korea. Also, they were similar to high results of tropical areas such as Taiwan and Nigeria, and higher than those of western and middle Europe and Tel Aviv, Israel.

Measurement of Specific Radioactivity for Clearance of Waste Contaminated with Re-186 for Medical Application (의료용 Re-186 오염폐기물의 규제해제를 위한 방사능측정)

  • Kim, Chang-Bum;Lee, Sang-Kyung;Jang, Seong-Joo;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.633-638
    • /
    • 2017
  • The amount of radioactive waste has been rapidly increased with development of radiation treatment in medical field. Recently, it has been a common practice to use I-131 for thyroid cancer, F-18 for PET/CT and Tc-99m for diagnosis of nuclear medicine. All the wastes concerned have been disposed of by means of the self-disposal method, for example incineration, after storage enough to decay less than clearance level. IAEA proposed criteria for clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). In this study, specific radioactivity of radioactive waste contaminated with Re-186 was measured to confirm whether it meets the clearance level. Re-186 has long half life of 3.8 days relatively and emits beta and gamma radiation, therefore it can be applied in treatment and imaging purposes. The specific radioactivity of contaminated gloves weared by radiation workers was measured by MCA(Multi-channel Analyzer) which was calibrated by reference materials in accordance with the measuring procedure. As a result, comparison evaluation of decay storage period between the half-life which was calculated by attenuation curve based on real measurement and physical half-life was considered, and it is showed that the physical half-life is longer than induced half-life. Therefore, the storage period of radioactive waste for self-disposal may be curtailed in case of application of induced half-life. The result of this study will be proposed as ISO standard.

Properties of Organic Acids and Volatile Components in Brown Rice Vinegar Prepared Using Different Yeasts and Fermentation Methods (효모 종류 및 발효 방식에 따른 현미식초의 유기산과 휘발성분 특성)

  • Yoon, Sung-Ran;Kim, Gui-Ran;Lee, Ji-Hyun;Lee, Su-Won;Yeo, Soo-Hwan;Jeong, Yong-Jin;Kwon, Joong-Ho
    • Food Science and Preservation
    • /
    • v.17 no.5
    • /
    • pp.733-740
    • /
    • 2010
  • Brown rice vinegars were prepared by agitated or static acetic acid fermentation using different yeast strains (Saccharomyces kluyveri DJ97, Saccharomyces cerevisiae JK99, Saccharomyces cerevisiae GRJ, or Saccharomyces cerevisiae H9). Organic acid contents and levels of volatile compounds were compared in vinegars prepared by different methods. The chosen yeast strain did not significantly affect the organic acid content of vinegar. In vinegars prepared by agitated acetic acid fermentation, organic acid contents were, in the order of descending abundance, acetic acid, citric acid, lactic acid, oxalic acid, and tartaric acid. In vinegars prepared by static acetic acid fermentation, no citric acid was detected, and lactic acid content was higher than that in agitated acetic acid fermented vinegar. The volatile compounds of both vinegars, analyzed by GC-MS, did not significantly differ when various yeast strains were used. Eighteen volatile compounds were detected in vinegar prepared by agitated acetic acid fermentation and 11 in vinegar prepared by static fermentation. Volatile compounds that can affect vinegar quality, including ethyl acetate and phenethyl acetate, were present at high concentrations in static acetic acid fermented vinegar. Electronic nose analysis showed that volatile chemical patterns differed between the two types of vinegar, but there were no significant differences in sensory scores between vinegars prepared using various yeast strains or by either of the two methods of fermentation.