• Title/Summary/Keyword: ion profile

Search Result 350, Processing Time 0.03 seconds

Evaluation on Chloride Attack by Colormetric Method in Marine Concrete Structures. (변색법을 활용한 해양 콘크리트 구조물의 염해평가)

  • Park, Jin-Ho;Kim, Myung-Yu;Kwak, Sang-Yun;Yang, Eun-Ik;Park, Hae-Geun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.181-184
    • /
    • 2005
  • When concrete structures are exposed under marine condition for a long time, the steel in concrete is corroded due to the ingression of chlorides in the seawater. Because the damages of corrosion resulting from the chloride ion are very serious, many researches have been performed. However evaluation on chloride attack of concrete structures are not fully examined, recently. Therefore, the objective of this paper is to study the applicability of colormetric method. For the purpose of this, reaction mechanism of colormetric method were investigated, and the colormetric method is applied for marine concrete structures. According to the test results, the diffusion coefficient by colormetric method is not so different to the value of chloride concentration profile test. It is confirmed that the colormetric method is useful tool for estimating the chloride of concrete structures in situ. The average chloride amount of colored parts indicates 0.9kg/$m^{3}$ per concrete unit weight.

  • PDF

Analysis of luminous efficacy of a PDP cell using a hybrid simulation with an electron-fluid and ion-particle model

  • Lee, Hae-June;Shim, Seung-Bo;Song, In-Cheol;Lee, Ho-Jun;Park, Chung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.24-27
    • /
    • 2009
  • A hybrid model has been developed which adopts a fluid model for electrons and a particle-in-cell (PIC) model for ions. Using the hybrid simulation, the discharge characteristics are investigated with the diagnostics for the electric field and the wall charge profile, density distributions of charged and excited particles, distributions of ultraviolet lights on phosphor, and the visible lights emitted from the PDP cell. Also, energy and angle distributions of the ions at the MgO protective layer are obtained for the analysis of material effect. The comparison of hybrid simulation results with experimental results as well as that with the conventional fluid simulation shows that the new model is more adequate for the simulation of PDP cells.

  • PDF

Beam Crossectional Monitor of Cyclotron using VXI Bus (VXI Bus를 이용한 싸이클로트론의 빔 단면 표시장치)

  • Cho, Young-Ho;Ahn, Doo-Soo;Lee, Han-Seok;Kim, Yu-Seok;Chai, Jong-Seo
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.442-444
    • /
    • 1998
  • We made the beam crosssectional monitor system which was possible to display the ion beam crosssection extracted from accelerator on personal computer monitor. Previous beam profile monitor system could detect the central beam position with limited low beam current, but this developed beam crosssectional monitor system could operate at the relatively higher beam current. In addition we realized the real time data taking system by adopting the VXI system for beam size, central position and crosssection.

  • PDF

Pharmacological and medical applications of Panax ginseng and ginsenosides: a review for use in cardiovascular diseases

  • Kim, Jong-Hoon
    • Journal of Ginseng Research
    • /
    • v.42 no.3
    • /
    • pp.264-269
    • /
    • 2018
  • Panax ginseng, also called Asian or Korean ginseng, has long been traditionally used in Korea and China to treat various diseases. The major active ingredients of P. ginseng are ginsenosides, which have been shown to have a variety of therapeutic effects, including antioxidation, anti-inflammatory, vasorelaxation, antiallergic, antidiabetic, and anticancer. To date, approximately 40 ginsenoside components have been reported. Current research is concentrating on using a single ginseng compound, one of the ginsenosides, instead of the total ginseng compounds, to determine the mechanisms of ginseng and ginsenosides. Recent in vitro and in vivo results show that ginseng has beneficial effects on cardiac and vascular diseases through efficacy, including antioxidation, control of vasomotor function, modulation of ion channels and signal transduction, improvement of lipid profiles, adjustment of blood pressure, improvement in cardiac function, and reduction in platelet adhesion. This review aims to provide valuable information on the traditional uses of ginseng and ginsenosides, their therapeutic applications in animal models and humans, and the pharmacological action of ginseng and ginsenosides.

Diffusion Model of Aluminium for the Formation of a Deep Junction in Silicon (실리콘에서 깊은 접합의 형성을 위한 알루미늄의 확산 모델)

  • Jung, Won-Chae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.4
    • /
    • pp.263-270
    • /
    • 2020
  • In this study, the physical mechanism and diffusion effects in aluminium implanted silicon was investigated. For fabricating power semiconductor devices, an aluminum implantation can be used as an emitter and a long drift region in a power diode, transistor, and thyristor. Thermal treatment with O2 gas exhibited to a remarkably deeper profile than inert gas with N2 in the depth of junction structure. The redistribution of aluminum implanted through via thermal annealing exhibited oxidation-enhanced diffusion in comparison with inert gas atmosphere. To investigate doping distribution for implantation and diffusion experiments, spreading resistance and secondary ion mass spectrometer tools were used for the measurements. For the deep-junction structure of these experiments, aluminum implantation and diffusion exhibited a junction depth around 20 ㎛ for the fabrication of power silicon devices.

Kinetic Studies on the Addition of Potassium Cyanide to α,N-Diphenylnitrone

  • 김태린;김영호;변상용
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.6
    • /
    • pp.712-714
    • /
    • 1999
  • The rate constants for the nucleophilic addition of potassium cyanide to α,N-diphenylnitrone and its derivatives (p-OCH3, p-CH3, p-Cl, and p-NO2) were determined by ultraviolet spectrophotometer at 25℃, and the rate equations which can be applied over a wide pH range were obtained. On the basis of pH-rate profile, adduct analysis, general base catalysis and substituent effect, a plausible mechanism of this addition reaction was proposed: At high pH, the cyanide ion to carbon-nitrogen double bond was rate controlling, however, in acidic media, the reaction proceeded by the addition of hydrogen cyanide molecule to carbon-nitrogen double bond after protonation at oxygen of a,N-diphenylnitrone. In the range of neutral pH, these two reactions occured competitively.

Dissociative Recombination Rates of O₂+ Ion with Low Energy Electrons

  • 성정희;선호성
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.11
    • /
    • pp.1065-1073
    • /
    • 1996
  • The dissociative recombination of O2+(v+)+e-→O(1S)+O(1D) has been theoretically investigated using the multichannel quantum defect theory (MQDT). Cross sections and rate coefficients at various electron energies are calculated. The resonant structures in cross section profile, which are hardly measurable in experiments, are also determined and the existence of Rydberg states is found to affect the rates. The theoretical rate coefficients are computed to be smaller than experimental ones. The reasons for this difference are explained. The two-step MQDT procedure is found to be very useful and promising in calculating the state-to-state rates of the dissociative recombination reaction which is a very important and frequently found phenomenon in Earth's ionosphere.

SOC Estimation of Li-ion Battery Using ANN Based on Electric Vehicle Running Profile (전기 자동차 주행 프로파일 기반 ANN을 이용한 리튬 배터리 SOC 추정 연구)

  • Han, Dongho;Kwon, Sanguk;Kim, Seungwoo;Kim, Jonghoon;Lee, Sungeun
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.129-130
    • /
    • 2018
  • 리튬 이온 배터리가 전기 자동차 및 다양한 어플리케이션에 적용됨에 따라 배터리 관리 시스템(BMS)의 중요도가 높아지고 있다. 리튬 이온 배터리의 SOC(State of Charge) 및 단자전압 추정은 BMS에서 필수적이며 다양한 알고리즘을 통해 연구되고 있다. 본 논문에서는 비지도 학습 알고리즘인 뉴럴 네트워크의 학습을 위해 특성 파라미터(Characterstic Parmeter)를 선정하였으며, 특성 파라미터의 학습을 통해 리튬 이온배터리의 단자 전압 및 SOC를 추정하였다.

  • PDF

EDTA-functionalized KCC-1 and KIT-6 mesoporous silicas for Nd3+ ion recovery from aqueous solutions

  • Ravi, Seenu;Zhang, Siqian;Lee, Yu-Ri;Kang, Kyoung-Ku;Kim, Ji-Man;Ahn, Ji-Whan;Ahn, Wha-Seung
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.67
    • /
    • pp.210-218
    • /
    • 2018
  • Ethylenediaminetetraacetic acid (EDTA)-functionalized KIT-6 and KCC-1 mesoporous silicas were prepared via post-synthesis grafting and examined for their ability to promote the recovery of rare earth metal ions such as $Nd^{3+}$ from an aqueous medium. The obtained adsorption isotherms were fitted to the Langmuir model, which gave a maximum adsorption of $Nd^{3+}$ ions of 109.8 and 96.5 mg/g for KIT-6-EDTA and KCC-1-EDTA, respectively, at $25^{\circ}C$ and pH 6. The adsorption kinetic profile of KIT-6 was faster than KCC-1. KIT-6 was also proved to be more stable against desorption under acidic regeneration conditions.

Study on the beam properties of small field sizes (소조사면 전량분포의 특성에 관한 고찰)

  • Cho JeongHee;Lee SangKyu;An SeungKwon;Park Jell
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.1-9
    • /
    • 2004
  • Purpose : The aim of this study is to investigate the properties of small field size and to measure the penumbra and central axis depth dose varying to the jaw setting and off axis distance for indicate this data to small field sizes radiation therapy. Material and methods : The percentage depth dose, beam profile and central axis output dose was measured by farmer type ion chamber and pinpoint chamber using Primart linac with 6MV energy. Beam quality and penumbra variations according to the central axis shift, from center to every 2cm outside increment, and field size, from $1{\times}1cm$ to $10{\times}10cm$ was investigated and compared with that of the standard geometrical condition's results Results : The differences of measured values between two ion chamber was about $37\%$ at 10cm depth with $1{\times}1cm$ field sizes but as field size increased this differences was diminished gradually. Measured data from various off axis distance with the different asymmetric collimations are not changed significantly but as size decreased the dose variation was increased and at $1{\times}1cm$ field size dose difference among off axis distance was as much as $13\%$, and as shallower the measured depth the central axis dose variations among the OAD was increased, penumbra was not changed noticeably depending on off axis distance but the percentage of penumbra from its initial field sizes was strongly dependant on field sizes and penumbra occupation rates of its own field sizes ranging from $6\%$ at $10{\times}10cm$ to $50\%$ at $1{\times}1cm$ field size. Conclusion : For imrt treatment, there are several numbers of different gentry angles with beams of nonuniform fluences are required and several complex factors involved. Among them the characteristics of beam output varying to the geometrical setting and design of collimators are of important to attaining a good treatment results. As mentioned in results the differences of measured values are changed significantly depends on ion chamber volume, depths and field size. For providing quality radiation treatment, especially at small field size, those factor's should have considering deliberately.

  • PDF