• Title/Summary/Keyword: interval scanning

Search Result 104, Processing Time 0.028 seconds

Healing of the Bone around Hydroxyapatite-Coated Implants without Primary Bone Contact (초기 골 접촉이 없는 수산화 인회석 피복 임프란트 주위 골의 치유)

  • Cho, Hyung-Soo;Shin, Kwang-Yong;Kim, Heung-Joong;Park, Joo-Cheol;Han, Kyung-Yoon;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.2
    • /
    • pp.415-433
    • /
    • 1999
  • Implant stability is the key to long-term successful outcome for osseointegrated implants. To evaluate the initial healing response of bone around HA-coated implants without primary bone contact. 21 HA-coated thread type implants(STERI-OSS?) were placed in the femurs of 5 mongrel dogs, about 1-year old. Implants, 8 mm in length and 3.8mm(experimental 1group), 5.0mm(experimental 2group) and 6.0mm(control group) in diameter, were inserted after 3 holes of 6.0mm in diameter and 10mm in depth were prepared in the surgical sites each dog. Implants were supported by only nonresorbable membrane($Teflon^{(R)}$), in order to prevent the ingrowth of upper soft tissue into the gap between bone and implant, and to maintain each implant to be positioned in the center of the drilled hole. 9 implants with different diameters were inserted in 3 dogs for histologic observation, and 12 implants were inserted in 2 dogs for mobility test and removal torque test. Fluorescent dyes were injected for the observation of new bone formation in order of $Terramycin^{(R)}$, Arizarin $Red^{(R)}$, and $Calcein^{(R)}$ at an interval of 2 weeks. 3 dogs were sacrificed for histologic observation at 4, 8, and 12-week after placement. Light microscopy and confocal laser scanning microscopy were used to qualitatively characterize the bone around HA-coated implant. 2 dogs were sacrificed for mobility test($Periotest^{(R)}$, Simens AG, Bensheim, Germany) and removal torque test($Autograph^{(R)}$ AGS-1000D series, Japan) at 8 and 12-week after placement The results were as follows: 1. Histologic observation showed that osseointegration occurred to both control and experimental groups as time lapse, but delayed bone healing was revealed in 3.8mm group (experimental 1group), compared to contrtol group and 5.0mm group (experimental 2group). 2. The mobility test showed that the experimental groups had no distinguishable movement during experimental periods of 8 and 12-week, and there was no difference in mobility depending on the gap between bone and implant, and time lapse. 3. The removal torque forces were increased depended on the gaps decreasing between bone and implant, and time lapse. The results suggest that HA-coated implant without primary bone contact, based on guided bone regeneration could obtain its stability in all experimental groups as time lapse, but bone healing was delayed in experimental group of 3.8mm. And the results suggested that studies on correlationship between mobility test and removal torque test for implant stability would be necessary.

  • PDF

A whole genome sequence association study of muscle fiber traits in a White Duroc×Erhualian F2 resource population

  • Guo, Tianfu;Gao, Jun;Yang, Bin;Yan, Guorong;Xiao, Shijun;Zhang, Zhiyan;Huang, Lusheng
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.5
    • /
    • pp.704-711
    • /
    • 2020
  • Objective: Muscle fiber types, numbers and area are crucial aspects associated with meat production and quality. However, there are few studies of pig muscle fibre traits in terms of the detection power, false discovery rate and confidence interval precision of whole-genome quantitative trait loci (QTL). We had previously performed genome scanning for muscle fibre traits using 183 microsatellites and detected 8 significant QTLs in a White Duroc×Erhualian F2 population. The confidence intervals of these QTLs ranged between 11 and 127 centimorgan (cM), which contained hundreds of genes and hampered the identification of QTLs. A whole-genome sequence imputation of the population was used for fine mapping in this study. Methods: A whole-genome sequences association study was performed in the F2 population. Genotyping was performed for 1,020 individuals (19 F0, 68 F1, and 933 F2). The whole-genome variants were imputed and 21,624,800 single nucleotide polymorphisms (SNPs) were identified and examined for associations to 11 longissimus dorsi muscle fiber traits. Results: A total of 3,201 significant SNPs comprising 7 novel QTLs showing associations with the relative area of fiber type I (I_RA), the fiber number per square centimeter (FN) and the total fiber number (TFN). Moreover, one QTL on pig chromosome 14 was found to affect both FN and TFN. Furthermore, four plausible candidate genes associated with FN (kinase non-catalytic C-lobe domain containing [KNDC1]), TFN (KNDC1), and I_RA (solute carrier family 36 member 4, contactin associated protein like 5, and glutamate metabotropic receptor 8) were identified. Conclusion: An efficient and powerful imputation-based association approach was utilized to identify genes potentially associated with muscle fiber traits. These identified genes and SNPs could be explored to improve meat production and quality via marker-assisted selection in pigs.

The effect of chlorhexidine varnish application on the shear bond strength of orthodontic brackets (클로르헥시딘 바니쉬의 적용이 교정용 브라켓의 전단접착강도에 미치는 영향)

  • Im, Dong-Hyuk;Kim, Tae-Woo;Chang, Young-Il;Nahm, Dong-Suk;Yang, Won-Sik;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.30 no.2 s.79
    • /
    • pp.215-222
    • /
    • 2000
  • The purpose of this study was to determine whether the application of chlorhexidine varnish affects the shear bond strength and failure pattern of orthodontic brackets or not. The experimental group consisted of 22 human premolars which extracted after chlorhexidine varnish application (4 times for 1 week interval) in vivo, and the control group consisted of 22 human premolars which extracted without any pre-treatment. After all teeth were etched with $37\%$ phosphoric acid gel, metal orthodontic brackets (Q-3002, RMO, USA) were bonded to each tooth using auto-polymerizing orthodontic resin (Ortho-One, Bisco, USA) with the same bonding procedure. The shear bond strength was measured with Instron universal testing machine (model 4466, Instron Ltd., England), and the failure pattern of each bracket was examined with Scanning Electron Microscope (SM 840A, JEOL, Japan). The data were analysed statistically with t-test. The results were as follows : 1. Application of chlorhexidine varnish had no significant effect on the shear bond strength of the orthodontic bracket. 2. There was no significant difference in the failure pattern of orthodontic bracket between the experimental group and the control group.

  • PDF

Measurement of Quality Parameters of Honey by Reflectance Spectra

  • Park, Chang-Hyun;Yang, Won-Jun;Sohn, Jae-Hyung;Kim, Jong-Hoon
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1530-1530
    • /
    • 2001
  • The objectives of this study were to develop models to predict quality parameters of Korean bee-honeys by visible and NIR spectroscopic technique. Two kinds of bee-honey fronl acacia and polyflower sources were tested in this study. The honeys were harvested in the spring of 2000 and stored in the storage facility at 20$^{\circ}C$ during experiments. Total of 394 samples of honey were analyzed. Reflectance spectra, moisture contents, ash, invert sugar, sucrose, F/G (fructose/glucose) ratio, HMF (hydroxymethyl furfural), and C12/C13 ratio of honeys were measured. The average values for the tested honeys were 19.9% of moisture contents, 0.12% of ash, 68.4% of invert sugar, 5.7% of sucrose, 1.27 of F/G(fructose/glucose) ratio, 14.4 mg/kg of HMF, and -19.1 of C12/C13 ratio. A spectrophotometer, equipped with a single-beam scanning monochromator (NIR Systems, Model 6500, USA) and a horizontal setup module, was used to collect reflectance data from honey. The reflectance spectra were measured in wavelength ranges of 400∼2,498 nm. with 2 nm of interval. Thirty-two repetitive scans were averaged, transformed to log(1/Reflectance), and then were stored in a microcomputer file, forming one spectrum per measurement. A sample cell and reflectance plate were made to hold honey samples constantly. Spectra of honey samples were divided into a calibration set and a validation set. The calibration set was used during model development, and the validation set was used to predict quality parameters from unknown spectra. The PLS(Partial Least Square) models were developed to predict the quality parameters of honeys. The first and the second derivatives of raw spectra were also used to develop the models with proper smoothing gap. The MSC (multiplicative scatter correction) and the SNV & Dtr.(standard normal variate and detranding) preprocessing were applied to all spectra to minimize sample-to-sample light scatter differences. The PLS models showed good relationships between predicted and measured quality parameters of honeys in the wavelength range of 1100∼2200 nm. However, the PLS analysis was not good enough to predict HMF of honeys.

  • PDF

Clinical Study of CT-diagnosed Olivopontocerebellar Atrophies (Olivopontocerebellar Atrophy의 임상상과 전산화단층뇌촬영 소견)

  • Park, Mee-Yeong;O, Khyoung-Yhun;Hah, Jung-Sang;Byun, Yeung-Ju;Park, Choong-Suh
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.2
    • /
    • pp.87-93
    • /
    • 1988
  • The diagnosis of OPCA could be made clinically with important aid of brain CT scanning, although the definite and conclusive diagnosis only by postmortem pathological determination. We reviewed, clinically and with brain CT examination, 12 cases of patients with OPCA who were admitted to the Yeungnam University Hospital for a recent 5 years. The result were as following. : 1. The distribution of age is from 49 to 72, mainly 50 to 60. Man is more frequent than women at the 4.5 times. 2. The interval period from Sx. onset to diagnosis is 1 year to 6 years. 3. The usual initial Sxs. were dizziness(58%), ataxia(33%), and other less frequent Sxs. were weakness of low extremities, dysarthria, headache and urinary incontinence. The clinical manifestations at the initial diagnosis were cerebellar disturbance(100%), dysarthria(83%), and increased deep tendon reflexes(58%). 4. The results of brain CT finding are like this : ${\cdot}$ the width of cerebellar sulci is more than 1mm, other 4 cases more than 2mm. ${\cdot}$ the width of cerebellar pontine cistern of the patient if usually 3 to 4mm, other 2 cases extended to the 5mm. ${\cdot}$ the A. P and lateral lengths of 4th. ventricle is 4mm and 4 to 8mm respectively. ${\cdot}$ 6 cases of whole patients show coincidentally cerebral atrophy.

  • PDF

A study for improving the surgical mess using palatal and buccal mucosal incisions in oral and maxillofacial area (구개점막과 협점막의 절개에 사용되는 칼의 개선을 위한 기초 연구)

  • Seo Byoung-Moo;Choi Jin-Young;Lee Jong-Ho;Kim Myung-Jin;Choung Pill-Hoon
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.4 no.1
    • /
    • pp.1-11
    • /
    • 2001
  • Disposable blade is widely used for palatal and oral mucosal incision in oral and maxillofadal surgery nowadays, But its design and durability need for improvement, Especially, there are so many hard tissues intraoral area, such as bone and tooth, therefor the sharpness of the surgical blade was easily destroyed, The purpose of this study was to make basic data for developing new design of surgical blade using in oral and maxillofacial area including for the patients who have cleft lip and palate deformities, Some questionnaires about the usefulness of currently used surgical blades were sent to 150 dentists, the 54 of them made a reply, Secondly, The used-once blade and fresh new blade were examined under the scanning electron microscope with the 4000-times magnification, Lastly, the tissue reaction following the surgical incision with a fresh-new and a used blade on rat buccal cheek mucosa and hard palate was evaluated with light microscope with hematoxilin-eosin staining, The time interval from the surgical trauma to taking a sample were 1 day, 3 days, 7 days, and 14 days, At each time schedule, 2 Sprague-Dawley rats were sacrificed, Many dentists were agreed to need for changing the design of the surgical blades and also demand to improve the durability of the blades, They were also eager to adopt the new design of blade if it was available, The blade used in surgical extraction procedure was heavily damaged in its sharpe edge of number 15 blade, The histological differences were not prominent, but the delayed healing was detected in buccal mucosal defects especially in the surgical group with used blade, There are slight different changes in hard palatal defects between a used and a new blade group, In this study, we could find that there are imperative demanding on improvement of surgical blade design and durability for oral and maxillofadal area, The blade currently using in surgical extraction was easily damaged, The animal model of this study was not perfect for the purpose of this study.

  • PDF

Control of Powdery Mildew on Solanaceous Crops by Using COY (Cooking Oil and Yolk Mixture) in the Greenhouse (난황유를 이용한 가지과 작물의 흰가루병 방제)

  • Kwon, Jin-Hyeuk;Shim, Chang-Ki;Jee, Hyeong-Jin;Park, Chang-Seuk
    • Research in Plant Disease
    • /
    • v.15 no.1
    • /
    • pp.23-29
    • /
    • 2009
  • Cooking oil and yolk mixture (COY), a environmentally acceptable plant protection agent, and COY+$CaCO_3$+neem oil mixture were studied to control the powdery mildew occurring on eggplant, paprika, cherry tomato and maturity tomato in glass houses and vinyl houses during 2005 to 2007. The morphological changes of the pathogenic fungi on the leaf surface before and after treatment of COY were observed. COY made of rape seed oil and COY+$CaCO_3$+neem oil mixture were sprayed three times with 5 days interval to foliar parts of eggplant, paprika and tomato and the disease development were examined 5 days after final spray. In eggplant, the control efficacy of COY to powdery mildew was 94.6%. In paprika, the control efficacy of COY to powdery mildew was 91.6% and that of COY+$CaCO_3$+neem oil mixture was 96.2% that revealed little higher than COY itself. In tomatoes(cherry or maturity tomato), the control efficacy of COY were about 91 %, however, when COY mixture were sprayed to tomato leaves and stems the powdery mildew was controlled completely. Typical and healthy mycelia, conidiophores and condia were observed through scanning electron microscope in COY unsprayed leaf surface, on the other hand destroyed and winkled mycelia and conidiophores were observed in COY treated leaves regardless host plants nor taxonomic differences of fungi.

Comparison Study about Surface Mapping of Motor Points in Biceps Brachii Muscle Using Surface EMG and Electric Probe (표면 근전도와 전기 탐침기를 이용한 상완이두근의 운동점 표지 비교 연구)

  • Park, Jaewon;Keum, Dongho
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.28 no.1
    • /
    • pp.85-96
    • /
    • 2018
  • Objectives This study was performed to compare the electrical methods of motor points mapping using surface EMG and electric probe (Pointer Excel II). Methods 32 healthy adults (male 16, female 16) were selected. and classified into two groups; surface EMG group, electric probe (Pointer Excel II) group. In surface EMG group, motor points were searched by recoding the compound muscle potentials. In electric probe (Pointer Excel II) group, motor points were searched by scanning the skin with Pointer Excel II at low level stimulation. The locations of the motor points were expressed as X and Y values in relation to the reference line. The horizontal reference line was set as elbow crease and the vertical reference line was set as the line connecting coracoid process to the center of the horizontal reference line. The data was analyzed by 'Independent T-test' and 'equivalence test'. Results 1. The motor points of short head and long head of biceps brachii muscle were located at about 2/3 length of the vertical reference line from coracoid process and about 1/5~1/4 length of the half of the horizontal reference line from the vertical reference line in both group. 2. The motor points of the short head were located more distally and close to the vertical reference line (p<0.001). 3. In surface EMG group, the motor points of the long head were located more laterally in the female than male. And the motor points of the long head were located more distally in the left side than right side (p<0.05). In electric probe (Pointer Excel II) group, similar tendency was observed but there was no statistically significant difference (p>0.05). 4. As a result of the equivalence test between surface EMG group and electric probe (Pointer Excel II) group, the confidence intervals of the difference were within the equivalence limit. Therefore, the locations of the motor points searched by two ways are equa l (p>0.05, equivalence interval=3%). Conclusions The results indicate that electric probe (Pointer Excel II) can be used to search the motor points instead of surface EMG. This might improve the clinical efficiency when using the motor points to treat muscle dysfunction.

Factors Predicting the Interface Pressure Related to Pressure Injury in Intensive Care Unit Patients (중환자실 환자의 욕창 관련 경계압력 예측요인)

  • Shine, Ji Seon;Kim, Soo Jin;Lee, Ji Hyun;Yu, Mi
    • Journal of Korean Academy of Nursing
    • /
    • v.47 no.6
    • /
    • pp.794-805
    • /
    • 2017
  • Purpose: Interface pressure is a factor that contributes to the occurrence of pressure injuries. This study aimed to investigate interface pressure at common sites of pressure injury (occipital, gluteal and peritrochanteric areas), to explore the relationships among risk factors, skin condition and interface pressure, and to identify risk factors influencing interface pressure. Methods: A total of 100 patients admitted to the intensive care unit were enrolled at a tertiary teaching hospital in Korea. Interface pressure was recorded by a scanning aid device (PalmQ). Patient data regarding age, pulmonary disease, Braden Scale score, body mass index, serum albumin, hemoglobin, mean blood pressure, body temperature, and oxygen saturation were included as risk factors. Data collected from July to September 2016 were analyzed using binary logistic regression. Results: The mean interface pressure of the occipital, gluteal, and right and left peritrochanteric areas were 37.96 (${\pm}14.90$), 41.15 (${\pm}16.04$), 53.44(${\pm}24.67$), and 54.33 (${\pm}22.80$) mmHg, respectively. Predictive factors for pressure injuries in the occipital area were age ${\geq}70$ years (OR 3.45, 95% confidence interval [CI]: 1.19~9.98), serum albumin deficit (OR 2.88, 95% CI: 1.00~8.26) and body temperature ${\geq}36.5^{\circ}C$ (OR 3.12, 95% CI: 1.17~8.17); age ${\geq}70$ years (OR 2.81, 95% CI: 1.10~7.15) in the right peritrochanteric area; and body temperature ${\geq}36.5^{\circ}C$ (OR 2.86, 95% CI: 1.17~6.98) in the left peritrochanteric area. Conclusion: Our findings suggest that old age, hypoalbuminemia, and high body temperature may be contributory factors to increasing interface pressure; therefore, careful assessment and nursing care of these patients are needed to prevent pressure injury. Further studies are needed to establish cutoff values of interface pressure for patients with pressure ulcers.

A STUDY ON THE GALVANIC CORROSION OF TITANIUM USING THE IMMERSION AND ELECTROCHEMICAL METHOD (침적법과 전기화학법을 이용한 티타늄의 갈바닉 부식에 관한 연구)

  • Kay, Kee-Sung;Chung, Chae-Heon;Kang, Dong-Wan;Kim, Byeong-Ok;Hwang, Ho-Gil;Ko, Yeong-Mu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.584-609
    • /
    • 1995
  • The purpose of this study was to evaluate the difference of the galvanic corrosion behaviour of the titanium in contact with gold alloy, silva-palladium alloy, and nickel-chromium alloy using the immersion and electrochemical method. And the effects of galvallit couples between titanium and the dental alloys were assessed for their usefulness as materials for superstructure. The immersion method was performed by measuring the amount of metal elementsreleased by Inductivey coupled plasma emission spectroscopy(ICPES) The specimen of fifteen titanium plates, the five gold alloy, five silver-palladium, five nickel-chromium plates, and twenty acrylic resin plates ware fabricated, and also the specimen of sixty titanium plugs, the thirty gold alloy, thirty silver-palladium, and nickelc-hromium plugs were made. Thereafter, each plug of gold alloy, silver-palladium, and nickel-chromium inserted into the the titanium and acrylic resin plate, and also titanium plug inserted into the acrylic resin plate. The combination specimens uf galvanic couples immersed in 70m1 artificial saliva solution, and also specimens of four type alloy(that is, titanium, gold, silver-palladium and nickel-chromium alloy) plugs were immersed solely in 70m1 artificial sativa solution. The amount of metal elements released was observed during 21 weeks in the interval of each seven week. The electrochemical method was performed using computer-controlled potentiosta(Autostat 251. Sycopel Sicentific Ltd., U.K). The wax patterns(diameter 11.0mm, thickness,in 1.5mm) of four dental casting alloys were casted by centrifugal method and embedded in self-curing acrylic resin to be about $1.0cm^2$ of exposed surface area. Embedded specimens were polished with silicone carbide paper to #2,000, and ultrasonically cleaned. The working electrode is the specimen of four dental casting alloys, the reference electrode is a saturated calmel electrode(SCE) and the ounter electrode is made of platinum plate. In the artificial saliva solution, the potential scanning was carried out starting from-700mV(SCE) TO +1,000mV(SCE) and the scan rate was 75mV/min. Each polarization curve of alloy was recorded automatically on a logrithmic graphic paper by XY recorder. From the polarization curves of each galvanic couple, corrosion potential and corrosion rates, that is, corrosion density were compared and order of corrosion tendency was determined. From the experiments, the following results were obtained : 1. In the case of immersing titanium, gold alloy, silver-palladium alloy, and nickel-chromium alloysolely in the artificial saliva solution(group 1, 2, 3, and 4), the total amount of metal elements released was that group 4 was greater about 2, 3 times than group 3, and about 7.8 times than group 2. In the case of group 1, the amount of titanium released was not found after 8 week(p<0.001). 2. In the case of galvanic couples of titanium in contact with alloy(group 5, 6), the total amount of metal elements released of group 5 and 6 was less than that of group 7, 8, 9, and 10(p<0.05). 3. In the case of galvanic couples of titanium in contact with silver-palladium alloy(group 7, 8), the total amount of metal elements released of group 7 was greater about twice than that of group 5, and that of group 8 was about 14 times than that of group 6(p<0.05). 4. In the case of galvanic couples of titanium in contact with nickel-chromium alloy(group 9, 10), the total amount of metal elements released of group 9 and 10 was greater about 1.8-3.2 times than that of group 7 and 8, and was greater about 4.3~25 times than that of group 5 and 6(p<0.05). 5. In the effect of galvanic corrosion according to the difference of the area ratio of cathode and anode, the total amount of metal elements released was that group 5 was greater about 4 times than group 6, group 8 was greater about twice than group 7, and group 10 was greater about 1.5 times than group 9(p<0.05). 6. In the effect of galvanic corrosion according to the elasped time during 21 week in the interval of each 7 week, the amount of metal elements released was decreased markedly in the case of galvanic couples of the titanium in contact with gold alloy and silver-palladium alloy but the total amount of nickel and beryllium released was not decreased markedly in the case of galvanic couples of the titanium in contact with nickel-chromium alloy(p<0.05). 7. In the case of galvanic couples of titanium in contact with gold alloy, galvanic current was lower than any other galvanic couple. 8. In the case of galvanic couples of titanium in contact with nickel-chromium alloy, galvanic current was highest among other galvanic couples.

  • PDF