• Title/Summary/Keyword: interval dimension

Search Result 104, Processing Time 0.036 seconds

Classification of Sizing System for Womens Lower Clothes According to Body Type and Age Group (성인 여성의 체형별 연령층별 하의 치수 체계)

  • 정명숙;김구자
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.4
    • /
    • pp.743-753
    • /
    • 2001
  • This paper proposed the sizing system for womens lower clothes. The sizing system was classified according to 4 body types and 5 age groups. The size intervals of waist girth, hip girth, stature, and slacks length were 3cm, 4cm, 8cm, and 5cm respectively. Frequency distribution analyzed with waist girth, hip girth, and stature showed that the most frequent sizes were 86-100-158 in the fattest-medium length H type, 77-92-158 in the fat-short M type, 68-92-158 in the balanced-long A type, and 65-88-158 in the balanced-medium length A type. The number of the sizes for lower clothes, which had frequencies more than 4∼5%, was 33 and each size was presented with slacks length, skirt length, thigh girth, and knee girth. Also frequency distribution analyzed with waist girth, hip girth, and slacks length showed that the most frequent sizes were 86-100-90 in the fattest-medium length H type, 74-96-90 in the fat-short M type, 68-92-90 in the balanced-long A type, and 65-88-90 in the balanced-medium length A type. The sizing system classified by age group had 21 cases in the early twenties, 21 cases in the late twenties, 18 cases in the early thirties, 16 cases in the late thirties, and 8 cases in the forties. This result will contribute to clothing fitness and efficient production.

  • PDF

Surgical Treatment of Primary Pulmonary Leiomyosarcoma; Two Cases Report (원발성 폐평활근육종의 외과적 치료;2례 보고)

  • 이문금
    • Journal of Chest Surgery
    • /
    • v.26 no.8
    • /
    • pp.654-660
    • /
    • 1993
  • The incidence of pulmonary leiomyosarcoma is very rare as a primary lung tumor. Usually, pulmonary leiomyosarcoma arise from the smooth muscle present in the bronchi or blood vessles. We had experienced two cases of primary pulmonary leiomyosarcoma. The first case was 28-year old male patient who had been in good health until admission, when he experienced an episode of dyspnea and sudden hemoptysis. The chest X-ray film revealed a large round tumor mass in left lower lobe measuring 6.5x9.5x5.3cm in dimension. On physical examination,the patient was friction rub and rales on the left lower chest and postoperative course was smooth and non-eventful. Emergency left lower lobectomy was performed due to repeated hemoptysis. Chemotheraphy was done postoperatively as an adjuvant therapy.The second case was 52-year-old man who had been well prior to admission, when recently he noticed a abrupt growing tendency of old pulmonary coin lesion in right lower lobe on routine physical examination. Since 1968, small round mass was gradually enlarged very slowly, during recent one year interval, the tumor mass was enlarged abruptly as twice in size on chest X-ray. Bronchoscopic examination revealed no specipic findings. Right lower lobectomy was performed and pathologic examination was answered as primary leiomyosarcoma without lymph node metastasis. Postoperative course was smooth, except local wound infection.

  • PDF

A Study on Ventricular Fibrillation Prediction through neurologic and multi-morphic analyze of intra-cardiac database and Implementation of Simulator (체내 심전도 데이터의 신경학적 분석 및 다형성 판별을 통한 심실세동 예측에 관한 연구 및 시뮬레이터 구현)

  • Shin, K.S.;Kim, J.K.;Park, H.C.;Lee, C.K.;Lee, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.489-490
    • /
    • 2008
  • 본 고에서는 체내 심실신호를 농하여 신경학적 분석 및 다형성의 측면에서 심실세동이 일어나는 것을 예측하는 분석 알고리즘을 설계하였다. 신경학적 측면에서는 시계열 신호의 Peak to Peak Interval을 예측법과 0.15Hz를 기준으로 HRV 신호의 AR Burg 모델링을 통하여 고주파성과 저주파성을 나누어 교감신경과 부교감신경의 활동성 통한 신경학적 예측법을 제시하였으며 또한 체내 심실신호의 비선형적 특성을 고려한 Fractal Dimension을 생성시킴으로서 주기성의 특성과 다형성 통한 예측법을 제시하였다. 체내 심전도를 기반으로 Simulation 하였으며 각 분석별 조합을 통하여 최적의 예측 구조를 찾고자 하였다. 의학적 의미가 있는 민감도와 특이도를 판별하였으며 예측을 위한 수행시간을 실험하였다. 이를 통하여 자율신경 활성도와 다형성 판별을 조합한 방법이 심실세동 예측을 위한 민감도의 측면에서 가장 우수함을 나타내었고 시뮬레이션을 위만 시뮬레이터(Simulator) UI(User Interface)를 제시하였다.

  • PDF

Classification of Size Specifications for the Ready-made Jacket-from 28 years to 35 on the Korean adult male- (신사복 상의제작을 위한 사이즈스팩의 분류-28세에서 35세 우리나라 남성을 대상으로-)

  • 김구자
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.8
    • /
    • pp.1090-1098
    • /
    • 1998
  • The purpose of this study was to classify size specifications of the Korean adult male for the men's ready-made garments, especially jacket and dress shirts. By the stratified sampling method, data were collected by the real anthropometric measurement and by the photo-graphic sources. Sample size was 532 subjects as the sample and their age range was from 28 to 35 years old. 66 variables from the direct anthropometric data in total were applied to analyze. ANOVA in SPSS WIN package was applied to the data and the expected frequency distribution of 10.000 men was calculated by the extraction of density function. This study was performed to classify size specifications by the control dimensions and at the same interval of KS-K. The drop values of 15, 12 and 9 have the high coverage rate of 26.00%, 24.29% and 21.06% respectively and are composed of the majority of 71.35% of the subjects. According to the drop values, size specifications and distribution of control and reference dimensions are predicted. About 52.12% of the expected frequency distribution without stature were covered by 12 size specifications.

  • PDF

Development of Suit-tops Size-system for Abdomen-obese Adult Males (복부비만 성인 남성의 상의류 치수체계 제안)

  • Lim, Jiyoung
    • Fashion & Textile Research Journal
    • /
    • v.22 no.1
    • /
    • pp.94-101
    • /
    • 2020
  • This helps plus-size consumers purchase ready-made clothes and improves fitness by analyzing the upper body shapes of abdomen-obese adult males; in addition, it creates a size system based on each size interval of obesity shapes. The criteria for the 572 male subjects surveyed were over 25 kg/㎡ of the BMI, over 90 cm of waist, and over 0.85 waist hip ratio. The results were as follows. First, the higher the age group, the higher the degree of abdominal obesity in each age group. The degree of obesity decreases age increase; however, was the risk of abdominal obesity increased. Second, Compared to standard body types, the average body size of Abdomen-obese males is significantly larger, especially in the waist area than in the chest area. Third, to propose a size system for abdominal obese adult males, 16 sections with a final 2% rate of appearance were finally adopted as suit-tops size system for abdominal obese adult males by applying a 3 cm dimension gap between each designation as specified in the KS standard. The coverage ratio for the 16 sections was 72.6% and the coverage effienciency was 4.5%. The results of this study can be used in a various clothes; in addition, the activation and segmentation of the plus-size market are also believed to be significant.

The Analysis of a Wind Load on a Container Crane Using a Computation Fluid Dynamics

  • Kwon, Soon-Kyu;Lee, Seong-Wook;Han, Dong-Seop;Han, Geun-Jo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.325-328
    • /
    • 2006
  • This study analyzed the fluid state around a container crane according to a wind direction when a wind load was applied to a container crane. The container crane for this research is a model of a 50-ton class used broadly in the current ports. The dimension of an external fluid field is $500m{\times}200m$. This study considered the change of a wind velocity according to an altitude in a criterion of a wind velocity, 50m/s, applying a power series law. An incident angle applied to an interval of 30 degrees in $0^{\circ}C$ ${\sim}$ $180^{\circ}C$ and this study carried out a computation fluid dynamics using a CFX 10. In this study, we indicate the wind pressure and coefficient according to the height and section figure of each member. In addition, we suggest the wind load according to a wind direction.

  • PDF

Insulation Ageing Diagnosis Using HFPD Pattern Analysis (HFPD 패턴분석을 이용한 절연열화 진단)

  • Kim, Deok-Keun;Yeo, In-Sun;Lim, Jang-Seob;Lee, Jin
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1726-1728
    • /
    • 2003
  • The aging diagnosis method using partial discharge measurement detects discharge signals that critical cause of failure in insulation material operated a long time and can diagnose aging state of insulation materials with an aging analysis algorithm. The HFPD measurement method is a technique to analyze aging state of high voltage insulation materials and detect higher frequency signals than conventional PD measurement method therefore it takes less noise effect and could execute active line measurement. It is possible to analyze main discharge phenomena and obtain access to aging progress occurred in insulation materials through accumulation of HFPD signals during determined interval and expression of fractal dimension using statistical process of accumulated signals. The HFPD signals that occurred in each applied voltages are measured during 180 cycles and accumulated to the same phase of one cycle. These patterns that made by previous method are normalized with logarithm function and than inputted to neural networks. The aging diagnosis of insulation material was possible and the recognition ratio of neural network appeared very high.

  • PDF

Calculation of Unit Hydrograph from Discharge Curve, Determination of Sluice Dimension and Tidal Computation for Determination of the Closure curve (단위유량도와 비수갑문 단면 및 방조제 축조곡선 결정을 위한 조속계산)

  • 최귀열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.7 no.1
    • /
    • pp.861-876
    • /
    • 1965
  • During my stay in the Netherlands, I have studied the following, primarily in relation to the Mokpo Yong-san project which had been studied by the NEDECO for a feasibility report. 1. Unit hydrograph at Naju There are many ways to make unit hydrograph, but I want explain here to make unit hydrograph from the- actual run of curve at Naju. A discharge curve made from one rain storm depends on rainfall intensity per houre After finriing hydrograph every two hours, we will get two-hour unit hydrograph to devide each ordinate of the two-hour hydrograph by the rainfall intensity. I have used one storm from June 24 to June 26, 1963, recording a rainfall intensity of average 9. 4 mm per hour for 12 hours. If several rain gage stations had already been established in the catchment area. above Naju prior to this storm, I could have gathered accurate data on rainfall intensity throughout the catchment area. As it was, I used I the automatic rain gage record of the Mokpo I moteorological station to determine the rainfall lntensity. In order. to develop the unit ~Ydrograph at Naju, I subtracted the basic flow from the total runoff flow. I also tried to keed the difference between the calculated discharge amount and the measured discharge less than 1O~ The discharge period. of an unit graph depends on the length of the catchment area. 2. Determination of sluice dimension Acoording to principles of design presently used in our country, a one-day storm with a frequency of 20 years must be discharged in 8 hours. These design criteria are not adequate, and several dams have washed out in the past years. The design of the spillway and sluice dimensions must be based on the maximun peak discharge flowing into the reservoir to avoid crop and structure damages. The total flow into the reservoir is the summation of flow described by the Mokpo hydrograph, the basic flow from all the catchment areas and the rainfall on the reservoir area. To calculate the amount of water discharged through the sluiceCper half hour), the average head during that interval must be known. This can be calculated from the known water level outside the sluiceCdetermined by the tide) and from an estimated water level inside the reservoir at the end of each time interval. The total amount of water discharged through the sluice can be calculated from this average head, the time interval and the cross-sectional area of' the sluice. From the inflow into the .reservoir and the outflow through the sluice gates I calculated the change in the volume of water stored in the reservoir at half-hour intervals. From the stored volume of water and the known storage capacity of the reservoir, I was able to calculate the water level in the reservoir. The Calculated water level in the reservoir must be the same as the estimated water level. Mean stand tide will be adequate to use for determining the sluice dimension because spring tide is worse case and neap tide is best condition for the I result of the calculatio 3. Tidal computation for determination of the closure curve. During the construction of a dam, whether by building up of a succession of horizontael layers or by building in from both sides, the velocity of the water flowinii through the closing gapwill increase, because of the gradual decrease in the cross sectional area of the gap. 1 calculated the . velocities in the closing gap during flood and ebb for the first mentioned method of construction until the cross-sectional area has been reduced to about 25% of the original area, the change in tidal movement within the reservoir being negligible. Up to that point, the increase of the velocity is more or less hyperbolic. During the closing of the last 25 % of the gap, less water can flow out of the reservoir. This causes a rise of the mean water level of the reservoir. The difference in hydraulic head is then no longer negligible and must be taken into account. When, during the course of construction. the submerged weir become a free weir the critical flow occurs. The critical flow is that point, during either ebb or flood, at which the velocity reaches a maximum. When the dam is raised further. the velocity decreases because of the decrease\ulcorner in the height of the water above the weir. The calculation of the currents and velocities for a stage in the closure of the final gap is done in the following manner; Using an average tide with a neglible daily quantity, I estimated the water level on the pustream side of. the dam (inner water level). I determined the current through the gap for each hour by multiplying the storage area by the increment of the rise in water level. The velocity at a given moment can be determined from the calcalated current in m3/sec, and the cross-sectional area at that moment. At the same time from the difference between inner water level and tidal level (outer water level) the velocity can be calculated with the formula $h= \frac{V^2}{2g}$ and must be equal to the velocity detertnined from the current. If there is a difference in velocity, a new estimate of the inner water level must be made and entire procedure should be repeated. When the higher water level is equal to or more than 2/3 times the difference between the lower water level and the crest of the dam, we speak of a "free weir." The flow over the weir is then dependent upon the higher water level and not on the difference between high and low water levels. When the weir is "submerged", that is, the higher water level is less than 2/3 times the difference between the lower water and the crest of the dam, the difference between the high and low levels being decisive. The free weir normally occurs first during ebb, and is due to. the fact that mean level in the estuary is higher than the mean level of . the tide in building dams with barges the maximum velocity in the closing gap may not be more than 3m/sec. As the maximum velocities are higher than this limit we must use other construction methods in closing the gap. This can be done by dump-cars from each side or by using a cable way.e or by using a cable way.

  • PDF

Evaluation of Conotruncal Anomalies by Electron Beam Tomography (Conotruncal 기형 평가에서 전자선 단층 촬영 (EBT)의 정확성)

  • 최병욱;박영환;최병인;최재영;김민정;유석종;이종균;설준희;이승규
    • Journal of Chest Surgery
    • /
    • v.33 no.4
    • /
    • pp.290-300
    • /
    • 2000
  • Background: To evaluate the diagnostic accuracy of EBT(Electron Beam Tomography) in the diagnosis of conotruncal anomaly and to determine whether it can be used as a substitute for cardiac angiography. Material and Method: 20 patients(11M & 9F) with TOF(n=7, pulmonary atresia 2), DORV(n=7), complete TGV(n=4), & corrected TGV(n=2) were included. The age ranged from 7 days to 26 years(median 60 days). We analyzed the sequential chamber localization, the main surgical concenrn in each disease category (PA size, LVED volume and coronary artery pattern for TOF & pulmonary atresia, the LV mass, LVOT obstruction, coronary artery pattern for complete TGV, and type of VSD and TV-PV distance for DORV, etc) and other associated anomalies(e.g., VSD, arch anomalies, tracheal stenosis, etc). Those were compared with the results of echocardiography(n=19), angiography (n=9), and surgery(n=11). The interval between EBT and echocardiography/angiography was within 20/11 days, respectively except for an angiography in a patient with corrected TGV (48 days). Result: EBT correctly diagnosed the basic components of conotruncal anomalies in all subjects, compared to echocardiography, angiography or surgery. These included the presence, type and size of VSD(n=20), pulmonic/LV outflow tract stenosis(n=15/2), relation of great arteries and the pattern of the proximal epicardial coronary arteries(16 out of 20). EBT proved to be accurate in quantitation of the intrapericardial and hilar pulmonary arterial dimension and showed high correlation and no difference compared with echocardiography, angiography, or surgery(p>0.05) except for left pulmonary arterial & ascending arterial dimension by echocardiography. LVED volume in seven TOF(no difference: p>0.05 & high correlation: r=0.996 with echocardiography), and LV mass in 4 complete TGV were obtained. Additionally, EBT enabled the cdiagnosis of subjlottic tracheal stenosis and tracheal bronchus in 1 respectively. Some peripheral PA stenosis were not detected by echocardiography, while echocardiography appeared to be slightly more accurate than EBT in detecing ASD or PDA. Conclusion: EBT can be a non-invasive and accurate modality of for the evaluation of most anatomical alteration including peripheral PS or interruption in patients with conotruncal anomalies. Combined with echocardiography, EBT study provides sufficient information for the palliative or total repair of anomalies.

  • PDF

Floc Property of Yeongsan Cohesive Bed Sediment with Respect to Salinity and Sediment Concentration (점착성 퇴적물의 염분과 퇴적물농도에 따른 플럭 특성: 플럭카메라를 이용한 실험연구)

  • Shin, Hyun-Jung;Smith, S. Jarrell;Lee, Guan-Hong
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.18 no.3
    • /
    • pp.122-130
    • /
    • 2013
  • To examine floc characteristics of cohesive bed sediment of the Yeongsan River estuary, a floc camera system has been developed and utilized to observe flocs under varying conditions. In order to validate the floc camera system, sand particles were passed through 88-125 and $63-88{\mu}m$ sieves and observed within the laboratory. Mean grain size and settling velocities were found to be 102 and $56.2{\mu}m$ and 6.7 and 5.9 mm/s, respectively. Artifacts of particles estimated outside of the sieve range are attributed to being imaged out of the depth of focus. However, as mean grain size and settling velocity of each size class were within the confidence interval, the floc camera system was confidently used to examine cohesive bed sediments of Yeongsan River estuary. The bed sediment sample was prepared with a concentration of 0.1 g/L in 0 psu deionized water. The mean grain size, settling velocity and fractal dimension of flocs were $40.6{\pm}0.66{\mu}m$, 14 mm/s, and 2.86, respectively. Experiments were also conducted using different salinities (10 and 34 psu) and sediment concentrations (0.1 and 0.3 g/L). Despite changing these parameters, the mean observed grain size and settling velocities were found to be the same within the error range of the system. The relatively higher values of settling velocity and fractal dimension are considered a result of the sediment containing relatively small concentrations of organic matter. Moreover, consistent floc size over various grain sizes and concentrations may be the result of insufficient turbulence to aggregate flocs.