• 제목/요약/키워드: interruption system

검색결과 386건 처리시간 0.024초

철도용 전기기기의 고장요인 및 절연열화 분석 (Analysis of faust cause & insulation degradation on the electrical equipments for railway)

  • 왕종배;전한준;박옥정;온정근
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.207-210
    • /
    • 2001
  • Electrical equipment for railway is always experiencing wear and degradation by mechanical, electrical and environmental stress in service and the fault or the accident of high voltage main circuit directly causes operation interruption. Particularly propulsion drive of high speed switching inverter takes the form of specific degradation mechanism such as fast rising transient surge, reflective overvoltage and harmonic stress, and it is known that it threatens the long life and the reliability of electrical equipment. In this paper, statistics of fault and accident on main electrical equipment for railway are presented and also insulation degradation mechanism, which governs end life of electrical device, is analyzed. Finally the method of fault respondence and reliability improvement on the main electrical equipments will be reviewed in order to prevent operation interruption.

  • PDF

Distribution System Reconfiguration Considering Customer and DG Reliability Cost

  • Cho, Sung-Min;Shin, Hee-Sang;Park, Jin-Hyun;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권4호
    • /
    • pp.486-492
    • /
    • 2012
  • This paper presents a novel objective function for distribution system reconfiguration for reliability enhancement. When islanding operations of distributed generators is prohibited, faults in the feeder interrupt the operation of distributed generators. For this reason, we include the customer interruption cost as well as the distributed generator interruption cost in the objective function in the network reconfiguration algorithm. The network reconfiguration in which genetic algorithms are used is implemented by MATLAB. The effect of the proposed objective function in the network reconfiguration is analyzed and compared with existing objective functions through case studies. The network reconfiguration considering the proposed objective function is suitable for a distribution system that has a high penetration of distributed generators.

비상발전기 통합제어 및 감시시스템 개발 (Development of an Integrated Control and Monitoring System for Emergency Power Generators)

  • 진강규;류길수;윤지근;유성호;김재환
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 춘계학술대회 논문집
    • /
    • pp.192-196
    • /
    • 2001
  • These days, most of electric power facilities need high stability. Therefore integrated system has been required to monitor and control electronic power distribution system in fields at all times when the interruption of electric power has occurred. To construct this system, unit that convert and process the input signal from fields needed. And for control and monitoring from remote place MMI software is required. Lastly network equipments are required for real-time communications. So, in this paper, units for control and monitoring of emergency power generator and for electric power monitoring in normal electric power and interruption of electric power are developed. Also integrated remote system for monitoring in remote is developed.

  • PDF

슬라이딩 접촉에 의한 집전시스템의 성능향상의 연구 (A study on the performance increasing of current collecting system with a sliding contact)

  • 정락교;김연수;윤용기;박성혁;정상기;이병송;목진용;최성규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.455-457
    • /
    • 1999
  • In this paper, the wearing characteristics of current collecting shoes, interruption phenomena and contact resistances between collecting shoes and conductor rails are established as design parameters for development of the third rail current collector. An experimental analysis for established design parameters is performed as the materials of current collector shoe, contact force, sliding velocity and contact condition(dry/wet condition) between current collectors shoe and conductor rails. As a result of this study, the magnitude of contact force is in proportion to the amount of wear in the collecting shoe, but is in inverse proportion to the interruption and contact resistance between the collecting shoe and the conductor rail. And optimal values of design parameters are pre sented through analyzing the experimental results of the amount of wear, interruption and contact resistance.

  • PDF

리눅스 운영체제에서 DLM을 이용한 USB 디바이스 커널 하드닝에 관한 연구 (A Study of USB Device Kernel Hardening Using DLM, in Linux Operating System)

  • 장승주;최은석
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2009년도 춘계 종합학술대회 논문집
    • /
    • pp.693-698
    • /
    • 2009
  • 컴퓨터 시스템을 중단 없이 정상적으로 동작 시키는 것은 중요한 문제 중의 하나이다. 이와 같이 컴퓨터 시스템이 중단 없이 동작하도록 하기 위하여 여러 가지 고장 감내 기법들이 개발 및 상용화되어 사용되고 있다. 대부분의 고장 감내 기법은 많은 경비가 소요된다. 본 논문은 리눅스 운영체제에서 동적 모듈(DLM)을 이용하여 USB 디바이스를 연결할 경우 USB 디바이스 사용에 대해 발생할 수 있는 커널 PANIC 현상을 줄이는 커널 하드닝 기법에 대해서 연구 한다.

  • PDF

72.5kV 20kA 전철용 가스차단기의 압력상승 측정 및 소전류 차단성능해석 (Pressure-Rise Measurement and Analysis of Low Current Interruption Capability of a 72.5kV 20kA Gas Circuit Breaker for Electrical Railway System)

  • 송기동;박경엽;정진교;오연호;민길식;박기엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.164-166
    • /
    • 1998
  • This paper presents the results of the measured pressure-rise and the analyzed results of the cold gas flow-field in a 72.5kV 20kA gas circuit breaker for the electrical railway system. The analysis of cold gas flow field and the calculation of electric field strength have been performed in 3 types of interrupters and the low current interruption capability has been estimated for each of the gas circuit breaker considering the opening speed, the nozzle shape and the stroke length.

  • PDF

배전계통 신뢰도를 고려한 전기설비투자 우선순위 결정 기법 (An Improved Investment Priority Decision Mettled for the Electrical Facilities Considering the Reliability of Distribution Networks)

  • 박창호;채우규;장성일;김광호;김재철;박종근;최정환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권4호
    • /
    • pp.177-184
    • /
    • 2005
  • This paper proposes a improved investment priority decision method of the facilities considering the reliability of distribution networks. The proposed method decides a investment order of the facilities combining, by fuzzy rules, the investment priority decision of KEPCO and the priority decision considering reliability evaluation indices. Where reliability evaluation indices are SAIFI(System Average Interruption Frequency Index) and SAIDI(System Average Interruption Duration Index), as referred to evaluation index for sustained interruption. The reliability analysis method of distribution networks applied in this paper utilizes analytic method, where the used reliability data is historical data of KEPCO. Particularly, we assumed that the failure rate increased as the equipment ages. To verify the performance of the proposed method, we applied it with the planned projects to reinforce the weak facility electrical facilities in KEPCO in 2004. The evaluation result showed that, under a limited budget, the reliability of the KEPCO in the Busan region using the proposed method can be enhanced than using the conventional KEPCO's method. Therefore, the results verify the proposed method can be efficiently used in the actual priorities method for investing the electrical facilities.

Clinical Uses of Diffusion Tensor Imaging Fiber Tracking Merged Neuronavigation with Lesions Adjacent to Corticospinal Tract : A Retrospective Cohort Study

  • Yu, Qi;Lin, Kun;Liu, Yunhui;Li, Xinxing
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권2호
    • /
    • pp.248-260
    • /
    • 2020
  • Objective : To investigate the efficiency of diffusion tensor imaging (DTI) fiber-tracking based neuronavigation and assess its usefulness in the preoperative surgical planning, prognostic prediction, intraoperative course and outcome improvement. Methods : Seventeen patients with cerebral masses adjacent to corticospinal tract (CST) were given standard magnetic resonance imaging and DTI examination. By incorporation of DTI data, the relation between tumor and adjacent white matter tracts was reconstructed and assessed in the neuronavigation system. Distance from tumor border to CST was measured. Results : The sub-portion of CST in closest proximity to tumor was found displaced in all patients. The chief disruptive changes were classified as follows : complete interruption, partial interruption, or simple displacement. Partial interruption was evident in seven patients (41.2%) whose lesions were close to cortex. In the other 10 patients (58.8%), delineated CSTs were intact but distorted. No complete CST interruption was identified. Overall, the mean distance from resection border to CST was 6.12 mm (range, 0-21), as opposed to 8.18 mm (range, 2-21) with simple displacement and 2.33 mm (range, 0-5) with partial interruption. The clinical outcomes were analyzed in groups stratified by intervening distances (close, <5 mm; moderated, 5-10 mm; far, >10 mm). For the primary brain tumor patients, the proportion of completely resected tumors increased progressively from close to far grouping (42.9%, 50%, and 100%, respectively). Five patients out of seven (71.4%) experienced new neurologic deficits postoperatively in the close group. At meantime, motor deterioration was found in six cases in the close group. All patients in the far and moderate groups received excellent (modified Rankin Scale [mRS] score, 0-1) or good (mRS score, 2-3) rankings, but only 57.1% of patients in the close group earned good outcome scores. Conclusion : DTI fiber tracking based neuronavigation has merit in assessing the relation between lesions and adjacent white matter tracts, allowing prediction of patient outcomes based on lesion-CST distance. It has also proven beneficial in formulating surgical strategies.

거시적 방법을 이용한 지역별 정전비용 평가 (Assessment of Customer Interruption Cost by Regional Groups for Macro Approach)

  • 박충열;허창수
    • 조명전기설비학회논문지
    • /
    • 제19권1호
    • /
    • pp.124-129
    • /
    • 2005
  • 최근의 전기사업은 전력산업 구조개편과 맞물려 전력계통의 공급신뢰도가 큰 문제로 대두되고 있다. 또한 에너지-산업 간의 경쟁 심화로 공급자 측에서의 공급신뢰도와 관련된 환경조건 변화가 고려되어야 한다. 즉 다른 에너지와의 요금 격차로 인해 수용가가 전력에너지를 타 에너지로 변환할 가능성이 있어 전력공급 신뢰도의 일률적 향상은 반드시 필수적인 전략이라고 말할 수 없기 때문에 이와 같은 문제점에 효율적으로 대처하기 위해서는 수용가의 공급신뢰도와 정전비용에 대한 반응을 감지할 필요가 있다. 따라서 본 논문에서는 이와 같은 대내외적인 환경에 대처하기 위해 매크로 접근방법을 이용하여 국내 각 지역별로 수용가 정전비용을 년도별로 평가하였다. 즉 각 시도별로 공공용, 서비스업, 농림${\cdot}$어업, 광업, 제조업, 주택용 수용가에 대해 수용가 정전비용과 전기요금 단가에 대한 비율을 평가하였다.