Analysis of loop impedance characteristic based on korea internal electrical environment (국내환경을 고려한 loop impedance 특성 분석)

  • Jung, Jin-Soo;Han, Woon-Ki;Kim, O-Huan;Ahn, Jae-Min;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2174_2175
    • /
    • 2009
  • This Paper present about loop impedance characteristic based on korea internal electrical environment. Analysis parameters were touch voltage, electrical shock current and human body resistance. Result, For protect of electrical shock must measuring of loop impedance. And current capacity & loop impedance are must important parameters.

  • PDF

A Signal Anti-reduction System for Power Line Communication

  • Ko Jong-Sun;Kim Hyun-Sik;Hong Soon-Chan
    • Journal of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.256-260
    • /
    • 2004
  • A new communication system is suggested using a single-phase full-bridge inverter with high efficiency ferrite core for power line communication (PLC). The conventional system has a decreasing signal voltage problem due to internal resistance. The proposed system has almost zero internal impedance and replaces a linear amplifier.

A Case of Continuous Ambulatory Peritonitis Dialysis Peritonitis Due to Stenotrophomonas maltophilia Using Antibiotic Combination (항생제 병용요법으로 치료한 Stenotrophomonas maltophilia 복막투석 복막염 1예)

  • Ko, Hee Sung;Choi, Ah Ran;Kim, Tae Hoon;Kyung, Chan Hee;Cho, Jang Ho;Kim, Yong Hoon;Lee, Jung Eun
    • Journal of Yeungnam Medical Science
    • /
    • v.30 no.2
    • /
    • pp.109-111
    • /
    • 2013
  • Continuous ambulatory peritoneal dialysis (CAPD) peritonitis is a major complication of peritoneal dialysis (PD) and leads to the discontinuation of PD. Despite its limited pathogenicity, CAPD peritonitis caused by Stenotrophomonas maltophilia (S. maltophilia), an important nosocomial pathogen that is present in nature and is usually associated with plastic indwelling devices. Infection of S. maltophilia is associated with a poor prognosis, including inability to maintain the CAPD catheter, because of its resistance to multiple antibiotics. We report a case of CAPD peritonitis due to S. maltophilia that was treated successfully using oral Trimethoprim-sulfamethoxazole and intraperitoneal Ticarcillin/clavulanate without removing the dialysis catheter.

The Mechanisms of Resistance to TNF in TNF-Sensitive Cancer Cells Transfected with TNF-$\alpha$ Gene Using Retroviral Vector (암세포에서 Retroviral Vector를 이용한 종양괴사인자 유전자 이입후 획득된 종양괴사인자 내성의 기전)

  • Lee, Hyuk-Pyo;Oh, Yeon-Mok;Yoo, Chul-Gyu;Kim, Young-Whan;Shim, Young-Soo;Han, Sung-Koo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.3
    • /
    • pp.547-558
    • /
    • 1997
  • Background : Tumor necrosis factor(TNF) has been considered as an important candidate for cancer gene therapy based on its potent anti-tumor activity. However, since the efficiency of current techniques of gene transfer is not satisfactory, the majorities of current protocols is aiming the in vitro gene transfer to cancer cells and re-introducing genetically modified cancer cells to hoot. In previous study, it was shown that TNF-sensitive cancer cells transfected with TNF-$\alpha$ cDNA would become highly resistant to TNF. Understanding the mechanisms of TNF-resistance in TNF-$\alpha$ gene transfected cancer cells would be an important step for improving the efficacy of cancer gene therapy as well as for better understandings of tumor biology. This study was designed to evaluate the role of new protective protein synthesis in the acquired resistance to TNF of TNF-$\alpha$ gene transfected cancer cells. Method : We transfected TNF-$\alpha$ c-DNA to WEHI164, a murine fibrosarcoma cell line, using retroviral vector(pLT12SN(TNF)) and confirm the expression of TNF with PCR, ELISA, MIT assay. Then we determined the TNF resistance of TNF gene transfected cells(WEHI164-TNF) and the changes of TNF sensitivities after treatments with actinomycin D(transcription inhibitor) and cycloheximide ( translation inhibitor). Results : WEHI164 which was sensitive to TNF became resistant to TNF after being transfected with TNF-$\alpha$ gene and the resistance to TNF was partially reversed after treatment with actinomycin D, but not with cycloheximide. Conclusion : The acquired resistance to TNF after TNF-$\alpha$ gene transfection may be associated with synthesis of some protective proteins.

  • PDF

A Case of Imported Falciparum Malaria Resistant to CHLOROQUINE (Chloroquine에 내성을 보인 수입성 열대열 말라리아 1예)

  • Lee, Jae-Gu;Kang, Jae-Hwang;Choi, Jin-Hyun;Choi, Jin-Hak
    • Journal of agricultural medicine and community health
    • /
    • v.15 no.2
    • /
    • pp.130-133
    • /
    • 1990
  • Indigenons malaria which was recognized as one of the unavoidable disease has almost eliminated from this country. Recently, we must attend to imported malaria cases because of an increase in overseas travelers and workers to tropical countries where malaria is endemic. Sometimes resistant to conventional drug therapy. So, imported malaria become a new health problem. We experienced a case of imported falciparum malaria. which is resistant to CHLOROQUINE and cured by QUINIE SULFATE and FANSIDAR.

  • PDF

A Study on the Physical Characteristics of the Low-voltage Circuit Breaker Based on the Accelerated Degradation Test (가속 열화 시험에 따른 저압용 차단기의 물리적 특성에 관한 연구)

  • Sin dong, Kang;Jae-Ho, Kim
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.6
    • /
    • pp.1-8
    • /
    • 2022
  • This study analyzed the characteristics of insulation resistance and operating time based on an accelerated degradation test of a low-voltage circuit breaker. The experimental sample used a molded case circuit breaker (MCCB) and an earth leakage circuit breaker (ELCB). After measuring the insulation resistance of the circuit breakers, the leakage current was affected by an external rather than an internal structure. Furthermore, the insulation resistance of the circuit breakers with accelerated degradation was measured using a Megger insulation tester. In the accelerated degradation test, aging times of five, ten, 15, and 20 years were applied according to a temperature derived using the Arrhenius equation. Circuit breakers with an equivalent life of ten, 15, and 20 years had increased insulation resistance compared to those with less degradation time. In particular, the circuit breaker with an equivalent life of ten years had the highest insulation resistance. Component analysis of the circuit breaker manufactured through an accelerated degradation test confirmed that the timing of the increase in insulation resistance and the time of additive loss were the same. Finally, after analyzing the operating time of the circuit breakers with degradation, it was confirmed that the MCCB did not change, but the ELCB breaker failed.

Detection of Pyrazinamide Resistance in Mycobacterium Tuberculosis by Sequencing of pncA Gene (pncA 유전자의 염기 서열 결정에 의한 결핵균의 Pyrazinamide 내성 진단)

  • Hwang, Jee-Yoon;Kwak, Kyung-Rok;Park, Hye-Kyung;Lee, Ji-Seok;Park, Sam-Seok;Kim, Yun-Seong;Lee, Jung-Yoo;Chang, Chul-Hun;Lee, Min-Ki;Park, Soon-Kew
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.1
    • /
    • pp.94-105
    • /
    • 2001
  • Background : Examining the biological susceptibility of Mycobacterium tuberculosis to pyrazinamide (PZA) in vitro is very difficult as PZA is inactive under normal culture conditions. The biological susceptibility test, an enzyme assay for Pzase activity, and a genetic test for pncA gene mutations, were performed in order to predict PZA resistance. Methods : 28 cultured clinical isolates of Mycobacterium tuberculosis were tested. The biological susceptibility was performed by the absolute concentration method using Lowenstein-Jensen media. The PZase activity was tested by means of Wayne's method. A 710-bp region includes the entire open reading frame of pncA was amplified and sequenced. Results : All six strains with positive PZase activity exhibited no pncA mutations with one strain showing a false resistance in the biological susceptibility test. Among the 22 strains with no PZase activity, 21 exhibited showed pncA mutations. In the biological susceptibility test, 20 strains were resistant, and one was susceptible, and the other flied to test. The mutation types varied with ten missense, one silent and one nonsense mutation 1 slipped-strand mispairing, and 6 frameshift mutations. Three strains had an adenine to guanine mutation at position -11 upstream of the start codon. Conclusion : The mutation at the pncA promotor region is frequent at -11 upstream position. Automatic sequencing of pncA is a useful tool for rapid and accurate detection of PZA resistant M. tuberculosis, and for demonstrating the epidemiological relatedness of the PZA resistant M. tuberculosis strains.

  • PDF

Effects of Combined Resistance Training Program of Concentric and Eccentric Contraction Using Theraband on Shoulder Rotation Torque Max and Peak Power (Thera-Band를 이용한 단축성 & 신장성 수축 저항 훈련 프로그램이 어깨의 최대 토크와 최대 파워에 미치는 영향)

  • Han, Dong-Wook;Ahn, Yi-Rae;Lee, Na-Jung;Lee, Eun-Ju
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.1
    • /
    • pp.139-148
    • /
    • 2009
  • D. W. HAN. Y. R. AHN., N. J. LEE and E. J. LEE. Effects of Combined Restistance Training Program of Concentric and Eccentric Contraction Using Theraband on Shoulder Rotation Torque Max and Peak Power. Korean Joumal of Sport Biomechanics, Vol. 19, No. 1, pp. 139-148, 2009. The purpose of this study was to find out that combined concentric with eccentric resistance training program using Thera-Band was more effective than only concentric resistance training program on shoulder rotation torque max and peak power. 30 female students were randomly assigned to 3 equal group; concentric and eccentric, concentric, non training group. Subjects were tested in concentric and eccentric torque max and peak power of internal and external rotation using a CON-TERX isokinetic dynamometer. Subjects in training group participated in their regular five times a week for 4 weeks. After exercise, in concentric and eccentric training group, concentric and eccentric torque max, and peak power of internal rotator at 60 deg/sec were increased significantly. concentric peak power at 120 deg/sec were increased significantly. In concentric training group, only concentric peak power of internal rotator at 60 and 120 deg/sec was increased. In conclusion, we found out that combined concentric with eccentric resistance training program using Thera-Band was more effective than only concentric resistance training program on shoulder rotation torque max and peak power.

Fire Resistance Performance for Hybrid Fiber Reinforced High Strength Concrete Column Member (하이브리드 섬유보강 고강도콘크리트 기둥부재의 내화성능)

  • Won, Jong-Pil;Jang, Chang-Il;Lee, Sang-Woo;Kim, Heung-Youl;Kim, Wan-Young
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.6
    • /
    • pp.827-832
    • /
    • 2008
  • This study evaluated fire resistance performance for hybrid (polypropylene+steel) fiber reinforced high strength concrete column. Full-size columns were constructed and tested with or without fibers using ISO-834 fire curve. As the result of test, Control specimen occurred serious spalling and indicated rapidly internal temperature increasing. Specimen with polypropylene fiber occurred not spalling but steady internal temperature increasing. Specimen with hybrid fiber occurred not spalling as well as does not propagated temperature distribution. Therefore, hybrid fiber reinforced column specimen indicated a good fire resistance performance than other cases.