• 제목/요약/키워드: intermittent inspection

검색결과 16건 처리시간 0.025초

단속적 검사에서 스트레스한계를 가지는 램프스트레스시험을 위한 비모수적 추정 (Nonparametric Estimation for Ramp Stress Tests with Stress Bound under Intermittent Inspection)

  • 이낙영;안웅환
    • 품질경영학회지
    • /
    • 제32권4호
    • /
    • pp.208-219
    • /
    • 2004
  • This paper considers a nonparametric estimation of lifetime distribution for ramp stress tests with stress bound under intermittent inspection. The test items are inspected only at specified time points an⊂1 so the collected observations are grouped data. Under the cumulative exposure model, two nonparametric estimation methods of estimating the lifetime distribution at use condition stress are proposed for the situation which the time transformation function relating stress to lifetime is a type of the inverse power law. Each of items is initially put on test under ramp stress and then survivors are put on test under constant stress, where all failures in the Inspection interval are assumed to occur at the midi)oint or the endpoint of that interval. Two proposed estimators of quantile from grouped data consisting of the number of items failed in each inspection interval are numerically compared with the maximum likelihood estimator(MLE) based on Weibull distribution.

지수고장분포(指數故障分布) 및 단속검사하(斷續檢査下)의 최적(最適) 가속수명시험(加速壽命侍險)의 설계(設計) (Design of Optimal Accelerated Life Tests for the Exponential Failure Distribution under Intermittent Inspection)

  • 서순근;최종덕
    • 대한산업공학회지
    • /
    • 제17권1호
    • /
    • pp.95-108
    • /
    • 1991
  • For the case where the lifetime at a constant stress level has exponential distribution, optimal accelerated life test plans are developed under the assumptions of intermittent inspection and Type I censoring. In a optimal plan, the low and high stress levels, the proportion of test units allocated and the inspection times at each stress are determined such that the asymptotic variance of the maximum likelihood estimator of logarithmic transformed mean at the use condition is minimized. In addition to the optimal plan in which numerical technique to solve the set of nonlinear equations must be employed to determine inspection times at each stress level, we also propose another plans which employ equally-spaced or equal probability inspection schemes at two overstress levels of corresponding optimal one. For both optimal and proposed plans, computational results indicate that the asymptotic variance of the estimated mean at the use stress is insensitive to number of inspections at overstress levels for the range of parameter values considered.

  • PDF

대수정규분포와 간헐적 검사하에서 가속수명시험방식의 설계 (Design of Accelerated Life Test Plans for the Lognormal Failure Distribution under Intermittent Inspection)

  • 서순근;조호성
    • 품질경영학회지
    • /
    • 제24권2호
    • /
    • pp.25-43
    • /
    • 1996
  • This paper presents the optimal and practical constant-stress accelerated life test plans for the lognormal lifetime distribution tinder assumptions of intermittent inspection and Type-I censoring. In an optimal plan, the low stress level and the proportions of test units allocated at each stress are determined under given inspection scheme and number of inspections such that the asymptotic variance of the maximum likelihood estimator of a certain quantile at use condition is minimized. Although the practical plan adopts the same design criterion, it involves three rather than two overstress levels in order to compromise the practical deficiencies of the optimal plan. Computational experiments are conducted to choose an allocation plan and a inspection scheme of the practical plan and to compare with test plans over a range of parameter values.

  • PDF

Sequential Design of Inspection Times in Optimally Spaced Inspection

  • Park San-Gun;Kim Hyun-Joong;Lim Jong-Gun
    • Communications for Statistical Applications and Methods
    • /
    • 제13권1호
    • /
    • pp.11-17
    • /
    • 2006
  • The spacing of inspection times in intermittent inspection is of great interest, and several ways for the determination of inspection times have been proposed. In most inspection schemes including equally spaced inspection and optimally spaced inspection, the best inspection times in each inspection scheme depend on the unknown parameter, and we need an initial guess of the unknown parameter for practical use. Thus it is evident that the efficiency of the resulting inspection scheme highly depends on the choice of the initial value. However, since we can obtain some information about the unknown parameter at each inspection, we may use the accumulated information and adjust the next inspection time. In this paper, we study this sequential determination of the inspection times in optimally spaced inspection.

Development of Optimal Accelerated Life Test Plans for Weibull Distribution Under Intermittent Inspection

  • Seo, Sun-Keun
    • 품질경영학회지
    • /
    • 제17권1호
    • /
    • pp.89-106
    • /
    • 1989
  • For Weibull distributed lifetimes, this paper presents asymptotically optimal accelerated life test plans for practical applications under intermittent inspection and type-I censoring. Computational results show that the asymptotic variance of a low quantile at the design stress as optimal criterion is insensitive to the number of inspections at overstress levels. Sensitivity analyses indicate that optimal plans are robust enough to moderate departures of estimated failure probabilities at the design and high stresses as input parameters to plan accelerated life tests from their true values. Monte Carlo simulation for small sample study on optimal accelerated life test plans developed by the asymptotic maximum likelihood theory is conducted. Simulation results suggest that optimal plans are satisfactory for sample size in practice.

  • PDF

수명이 대수정규분포를 따를 때 연속 및 간헐적 검사하에서 가속수명시험의 설계와 소표본 연구 (Design of Accelerated Life Tests and Small Sample Study under Continuous and Intermittent Inspections for Lognormal Failure Distribution)

  • 서순근;정원기
    • 대한산업공학회지
    • /
    • 제23권1호
    • /
    • pp.177-196
    • /
    • 1997
  • In this paper, statistically optimal accelerated life test(ALT) plans considering statistical efficiency only and new compromise ALT plans to sacrifice some statistical efficiency in return for improved overall properties including estimobility probability and robustness for the model assumptions are developed under the assumptions of constant stress, intermittent inspection, Type I censoring and lognormal failure distribution which has been one of the popular choices of failure distributions in the extensive engineering applications of ALT. Computational experiments are conducted to compare with four ALT plans including two proposed ones under continuous and intermittent inspections over a range of parameter values in terms of asymptotic variance, sensitivities for guessed input values, and proportion of estimable samples, etc. The small and moderate sample properties for the proposed ALT plans designed under asymptotic criterion are also investigated by Monte Carlo simulation.

  • PDF

완전분해 점검을 통한 장기운영 전투기 전기배선시스템의 신뢰성분석 (EWIS Reliability Analysis of Aging Fighter Aircraft through Teardown Inspection)

  • 이호용
    • 한국항공운항학회지
    • /
    • 제26권4호
    • /
    • pp.116-121
    • /
    • 2018
  • According to the incresement of aging aircraft, Republic of Korea Air Force (RoKAF) conducted a teardown inspection of aircraft's EWIS (electrical wiring interconnection system) to determine the status of deterioration and the influence of failure occurrences due to it. The inspected aircraft were the retired fighter jets that had been used for more than 40 years. By analyzing defect type and the defect tendency, RoKAF can establish the necessary measures for the usage extension of their fleet and furthermore, the analysis results can be used as a basic data for the preparation of it's aircraft aging. EWIS inspection was done throughout careful visual inspection technique by removing all the ducts and pipes located in the fuselage and wings. For the aircraft wiring where no damage was found, the elongation tests were performed to determine the deterioration of wiring according to the location of the aircraft. The connectors, which is the main cause of intermittent failure, were completely disassembled and inspected for internal damage such as corrosion, abrasion, and traces of foreign objects. The detected defects were classified into 4 severity levels based on the type of damage, and the classified defects were weighted according to the criticality which may affects to it's system to establish the action plan.

Reasons for Variation in Sensitivity and Specificity of Visual Inspection with Acetic Acid (VIA) for the Detection of Pre-Cancer and Cancer Lesions of Uterine Cervix

  • Parashari, Aditya;Singh, Veena
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권12호
    • /
    • pp.7761-7762
    • /
    • 2013
  • Alternative strategies such as visual inspection of cervix with acetic acid, are real time, economical and easily implemented methods for cervical cancer screening. However, variable sensitivity and specificity have been observed in various community based studies. The possible reasons could include variation in man power training, light source used for visualization, and preparation of diluted (4-5%) acetic acid and its storage. A standardized protocol for training, teaching material (easy to understand in the local language) for trainees, supervision and reinforcement by intermittent and supplementary training to check the quality of their observation, a standard protocol for preparation dilute acetic acid and its storage and a standard good light source (equivalent to day light) are needed to minimize the variation in sensitivity and specificity of VIA in community settings.

병렬저항회로에 기반한 표면 전도성 균열감지패턴을 사용한 콘크리트 휨 부재의 균열 감지 (Crack Monitoring of RC beam using Surface Conductive Crack Detection Patterns based on Parallel Resistance Network )

  • 신경준;이도근;홍재헌;신동찬;채종현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권5호
    • /
    • pp.67-74
    • /
    • 2023
  • 세계적으로 많은 수의 콘크리트 구조물이 건설되어 사용되고 있다. 구조물을 안전하고 지속적으로 사용하기 위해서는 꾸준한 점검과 유지관리가 필요하다. 인력을 활용한 점검과 유지관리 기법은 효율적이긴 하지만, 현장 점검이 이루어지는 시점에 대한 단속적인 상태에 대한 점검만 가능하다. 이에 구조물의 상태를 연속적으로 모니터링 할 수 있는 시스템의 필요가 높아지고 있다. 따라서, 콘크리트 구조물의 표면에 전도성도막을 설치하여 균열 및 손상의 탐지하는 연구를 수행하였다. 콘크리트 구조물의 구조적 특성을 반영하여 균열의 발생과 진전을 모니터링 할 수 있는 병렬저항 형식의 균열감지패턴을 개발하였고, 이에 대한 실증연구를 수행하였다. 철근콘크리트 보부재를 제작하여 균열감지패턴을 설치하였고, 하중가력실험을 통해 균열 모니터링의 가능성을 검증하였다.