• Title/Summary/Keyword: intensity estimation

Search Result 619, Processing Time 0.029 seconds

Estimation of the GHG Intensity for Non-Manufacturing Plant : The Example of a University Campus (비 생산플랜트에서 온실가스배출 원단위 산정에 관한 연구 : 대학교 캠퍼스를 중심으로)

  • Park, Hyung-Joon;Rhee, Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.3
    • /
    • pp.46-52
    • /
    • 2012
  • During the past decades, energy and Green House Gas(GHG) emissions has risen as a global issue. This paper is about the energy intensity and the GHG intensity in a university campus using the weighting factor of total occupied time to the members of the university. Through this analysis, we could separately estimate GHG intensity per full-time and part-time members under the situation that the measuring data is not perfect. This analyzing procedure could be applied to other non-manufacturing institutions such as school, hospital, governmental institute, office building etc.

A Method to Estimate the Burnup Using Initial Enrichment, Cooling Time, Total Neutron Source Intensity and Gamma Source Activities in Spent Fuels

  • Sohee Cha;Kwangheon Park;Mun-Oh Kim;Jae-Hun Ko;Jin-Hyun Sung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.3
    • /
    • pp.303-313
    • /
    • 2023
  • Spent fuels (SFs) are stored in a storage pool after discharge from nuclear power plants. They can be transferred to for the further processes such as dry storage sites, processing plants, or disposal sites. One of important measures of SF is the burnup. Since the radioactivity of SF is strongly dependent on its burnup, the burnup of SF should be well estimated for the safe management, storage, and final disposal. Published papers about the methodology for the burnup estimation from the known activities of important radioactive sources are somewhat rare. In this study, we analyzed the dependency of the burnup on the important radiation source activities using ORIGEN-ARP, and suggested simple correlations that relate the burnup and the important source activities directly. A burnup estimation equation is suggested for PWR fuels relating burnup with total neutron source intensity (TNSI), initial enrichment, and cooling time. And three burnup estimation equations for major gamma sources, 137Cs, 134Cs, and 154Eu are also suggested.

Probeless Estimation of Electroluminescence Intensities Based on Photoluminescence Measurements of GaN-Based Light-Emitting Diodes

  • Kim, Jongseok;Jeong, Hoon;Choi, Won-Jin;Jung, Hyundon
    • Current Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.173-179
    • /
    • 2021
  • The electroluminescence (EL) intensities of GaN-based light-emitting diodes (LEDs) are estimated based on their photoluminescence (PL) properties. The PL intensity obtained under open-circuit conditions is divided into two parts: the PL intensity under a forward bias lower than the optical turn-on voltage, and the difference between the PL intensities under open-circuit conditions and under forward bias. The luminescence induced by photoexcitation under a constant forward bias lower than the optical turn-on voltage is primarily the PL from the excited area of the LED. In contrast the intensity difference, obtained by subtracting the PL intensity under the forward bias from that under open-circuit conditions, contains the EL induced by the photocarriers generated during photoexcitation. In addition, a reverse photocurrent is generated during photoexcitation under constant forward bias across the LED, and can be correlated with the PL-intensity difference. The relationship between the photocurrent and PL-intensity difference matches well the relationship between the injection current and EL intensity of LEDs. The ratio between the photocurrent generated under a bias and the short-circuit current is related to the ratio between the PL-intensity difference and the PL intensity under open-circuit conditions. A relational expression consisting of the ratios, short-circuit current, and PL under open-circuit conditions is proposed to estimate the EL intensity.

IVS using disparity estimation based on bidirectional quadtree (양방향 사진트리 기반 변이 추정을 이용한 중간 시점 영상 합성)

  • 김재환;임정은;손광훈
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.2295-2298
    • /
    • 2003
  • The correspondence problem for stereo image matching plays an important role in expanding view points as multi view video applications become more popular. The conventional disparity estimation algorithms have limitation to find exact disparities because they consider not image features but similiar intensity points. Thus we propose an efficient disparity estimation algorithm considering features of stereo image pairs. As simulation results, our proposed method confirms better intermediate views than the existing block-matching methods.

  • PDF

Land Cover Classification and SCS Runoff Estimation using Remotely Sensed Imaged (위성영상을 이용한 토지피복 분류 및 SCS 유출량 산정)

  • 이윤아;함종화;장석길;김성준
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.544-549
    • /
    • 1999
  • The objective of this study is to identify the applicability of land cover image classified by remotely sensed data ; Landsat TM merged by SPOT for hydrological applications such as SCS runoff estimation . By comparing the calssified land cover image with the statistical data, it was proved that hey are agreed well with little errors. As a simple application , SCS runoff estimation was tested by varying rainfall intensity and AMC with Soilmap classfied by hydrologica soil map.

  • PDF

The Estimation of Sound Attenuation Caused by Duct Silencer Using Sound Intensity Method (음향인텐시티법을 이용한 공조 덕트소음기의 감음성능평가방법에 관한 연구)

  • Kim, Seok-Hong;Son, Jang-Yeol;O, Jae-Eung;Kim, Yeo-Sik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.6 no.2
    • /
    • pp.54-61
    • /
    • 1987
  • This paper is to suggest the test method of sound attenuation caused by absorptive duct silencer using sound intensity method in field. In order to estimate sound attenuation, sound power being radiated from sound power source and duct exhaust terminal was measured by the sound pressure method and sound intensity method in semianechoic and common room. The results of the measured sound attenuation values by sound intensity method are more similar to those of theoretical calculation than those by the sound pressure method. In addition, sound intensity method is much less influenced by sound field condition or continuous background noise than the sound pressure method.

  • PDF

Fast Estimation of Three-dimensional Spatial Light Intensity Distribution at the User Position of an Autostereoscopic 3D Display by Combining the Data of Two-dimensional Spatial Light Intensity Distributions

  • Hyungki Hong
    • Current Optics and Photonics
    • /
    • v.8 no.3
    • /
    • pp.307-312
    • /
    • 2024
  • Measuring the three-dimensional (3D) spatial light intensity distribution of an autostereoscopic multiview 3D display at the user position is time-consuming, as luminance has to be measured at different positions around the user position. This study investigates a method to quickly estimate the 3D distribution at the user position. For this purpose, a measurement setup using a white semitransparent diffusing screen or a two-dimensional (2D) spatial sensor was devised to measure the 2D light intensity distribution at the user position. Furthermore, the 3D spatial light intensity distribution at the user position was estimated from these 2D distributions at different viewing distances. From the estimated 3D distribution, the characteristics of autostereoscopic 3D display performance can be derived and the candidate positions for further accurate measurement can be quickly determined.

The Effect of Leverage, Earning Management, Capital Intensity, and Inventory Intensity on Tax Aggressiveness of Manufacturing Companies in Indonesia

  • OKTAVIANI, Rachmawati Meita;PRATIWI, Yayang Eka;SUNARTO, Sunarto;JANNAH, Afifatul
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.7
    • /
    • pp.501-508
    • /
    • 2021
  • The largest source of revenue in Indonesia comes from the taxation sector. Taxes increase the state revenue, which the government utilizes for building public facilities and infrastructures, providing subsidies to the public, financing public interests, and so on. In addition to producing revenue, taxes may be used to promote economic stability. Thus, this study aims to examine and analyze the financial aspects of tax aggressiveness. The financial aspects include leverage, capital intensity, inventory intensity, and earning management. The population used in this study was manufacturing companies listed on the Indonesia Stock Exchange (IDX) for the 2016-2019 period. Data analysis was carried out based on Eviews, with a selected sample of 32 companies of four observation years. Therefore, the number of samples was 128. The results of this study revealed that the best estimation model to use is the Fixed Effect Model (FEM). This study proved that leverage and earning management had a positive and significant effect on tax aggressiveness. In contrast, capital intensity and inventory intensity did not affect tax aggressiveness. In addition, the result of this study is still far from perfect. It is, therefore, hoped that further research can add other variables to find better results.

Safety Estimation Index of Infectious Disease (COVID-19) in Workplaces (사업장에 적용 가능한 감염병(COVID-19) 위험성평가 지표 개발)

  • Kim, Ha Kyeong;Lee, Myoung Ha;Song, Hyung-Jun
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.2
    • /
    • pp.88-96
    • /
    • 2022
  • Widespread infectious diseases are a concern for workers working in confined spaces. However, there is no risk assessment index for the risk of infectious disease in the workplace. Therefore, we propose a simple but effective index model to assess the risk of infectious diseases in the workplace. The proposed model identifies the risk of each workplace through an evaluation sheet comprising the frequency and intensity of the infectious disease. The intensity of an infectious disease is generally governed by the density of workers, whereas frequency is the sum of physical-e nvironmental and human management factors. By multiplying intensity and frequency, the risk of the workplace is derived. Through the proposed model, we evaluate the risks of workers at 15 different work sites. The proposed model clearly reveals what should be improved to keep workers safe from infectious diseases and will be helpful in assessing the risk of contagious disease at the work place.