• Title/Summary/Keyword: intensity estimation

Search Result 619, Processing Time 0.025 seconds

A Study on the Implementation of Signal Transmission System Within Electric Culvert (지하 전력 구내에서 신호 전송 시스템의 실현에 관한 연구)

  • 진달복;오상기;최성주;나채동
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.3
    • /
    • pp.49-56
    • /
    • 1993
  • This paper describes design and implementation of signal transmission system using LCX as communication media, which has characteristics of high reliability easy for expansion and complex transmission of voice, data and video signal in Electric culvert. In this system, we estimated system performance as result of variable transmission characteristics test. In case of voice signal, transmission loss characteristics improved 5-10(dB] than designed Values in received signal level. In the test of speech quality estimation, we obtained satisfactory result as speech intensity = 3 (QSA value), speech atriculation = 4 (QRK value). As for data and video signal transmission, communication success rates were 981% 1 in monitoring and control functional test. As a result of transmission characteristics test in transmission line and system, transmission range by LCX communication system without repeater can reach in 6Km. This paper presents basic construction method using LCX communication system for total management in Electric culvert.

  • PDF

Fisheries resources management of crucian carp based on assessment of fish stock and potential yield in the mid-upper system of Seomjin River

  • Ryu, Hui Seong;Jang, Sung Hyun;Lee, Jung Ho;Lee, Jung Joon
    • Journal of Ecology and Environment
    • /
    • v.37 no.4
    • /
    • pp.209-216
    • /
    • 2014
  • This study was undertaken to suggest an effective fisheries resources management system by using stock assessment and potential yield analyses of crucian carp population in the mid-upper system of the Seomjin River. Fieldwork was conducted seasonally from 2008 to 2009 in the mid-upper system of the Seomjin River. The stock assessment was carried out by the swept area method and the potential yield was estimated by improved fisheries resource potential estimation system based on the Allowable Biological Catch. Also, the yield-per-recruit analysis was used to review the efficient management implication of the resource, Carassius auratus. As a result, the age at first capture ($t_c$) was estimated as 1.468 year, converted body length (BL) was 10.8 cm. Meaning the current fishing intensities, the instantaneous coefficient of fishing mortality (F) was $0.067year^{-1}$, and the yield-per-recruit analysis showed that the current yield per recruit was estimated to be 15.999 g with F and $t_c$. The instantaneous rate of fishing mortality that provides for Allowable Biological Catch ($F_{ABC}$) based on the current $t_c$ and F was estimated as $0.618year^{-1}$. Therefore, the optimum fishing intensities could be achieved at the higher fishing intensity for Carassius auratus. The calculated annual stock of C. auratus was estimated as 7,608 kg, and the potential yield was estimated as 343 kg with $t_c$ and F at the fixed current level. Using yield-per-recruit analysis, if F and $t_c$ were set at $0.618year^{-1}$ and 2 year, the yield per recruit and total allowable catch would be predicted to increase to 62 g and 2,531 kg by about 3.9 times and 7.3 times, respectively.

Development of Programs to Analyze Mechanical Load Data of Wind Turbine Generator Systems and Case Studies on Simulation Data (풍력발전시스템의 기계적 하중 데이터 분석 프로그램 개발과 시뮬레이션 데이터 적용 사례)

  • Bang, Je-Sung;Han, Jeong-Woo;Gil, Kyehwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.8
    • /
    • pp.789-798
    • /
    • 2013
  • The procedures and relevant programs developed for analyzing mechanical load data of wind turbine generator systems, which are obtained through type certification tests, are verified. The following issues according to IEC 61400-13 are covered in the developed programs: data validation, time series analysis, summary load statistics, generation of fatigue load spectra, and estimation of equivalent loads. A capture matrix for normal power production is generated to determine whether the collected data sets are sufficient to carry out fatigue analysis. Fatigue load spectra are obtained through the rainflow counting method using 50 load ranges; finally, equivalent loads are calculated using different S-N curve slopes, m, according to the relevant materials. Case studies are performed using aero-elastic simulation data of the NREL 5 MW baseline wind turbine with a monopile foundation.

A Study on the Sanitary Condition of Kitchens in Food Court/Cafeterias - An Observation on Seasonal Variations (휴게음식점 주방의 환경위생상태에 관한 조사연구 - 계절별 변화를 중심으로 -)

  • Kim, Jong-Gyu;Park, Jeong-Yeong;Kim, Joong-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.2
    • /
    • pp.118-127
    • /
    • 2012
  • Objectives: This study was undertaken to assess the sanitary conditions in the kitchens of food court/cafeterias and determine seasonal variations. Methods: We measured environmental factors (air temperature, relative humidity, illumination intensity, noise level), and dropping airborne microbes (bacteria and fungi) in the kitchens of eight food court/cafeterias in four seasons (January, April, July, and October). Air temperature and relative humidity were measured with in/out thermo-hygrometers at 1.2-1.5 m above floor level. Illuminance measurement was performed through the multiple point method of Korean Standards (KS). Noise level was measured by the standard methods for the examination of environmental pollution (noise and vibration) of Korea. The estimation of dropping airborne bacteria and fungi was performed through use of Koch's method. Results: The highest kitchen air temperature was in July, and the lowest in January. The average temperature surpassed $21^{\circ}C$ throughout the seasons, suggesting a higher temperature than required for the safe handling of food. Humidity in all the kitchens was measured in the range of 50-60%. Half of the kitchens showed illumination intensities below 300 Lux in April. It was found that the sound pressure level of noise in almost all of the kitchens was higher than 85 dB (A). The highest levels of dropping airborne bacteria and fungi were noted in July. The numbers of airborne bacteria were higher than those of fungi. The levels of dropping airborne bacteria and fungi were affected by air temperature, relative humidity, season, and place. Conclusions: This study indicates that the kitchen environments were unqualified to supply safe food. The hygiene level of the kitchens should be improved.

Efficient Estimation Method of Reception Rate for Terrestrial Digital TV Broadcasting Service (효율적인 지상파 디지털 TV방송 수신율 산정방안)

  • Kwon, Won-Hyun;Kim, Kwang-Ui
    • Journal of IKEEE
    • /
    • v.16 no.1
    • /
    • pp.7-14
    • /
    • 2012
  • In this paper, a reception rate of terrestrial digital TV broadcasting service is analyzed and a novel method which can estimate the broadcasting coverage rate more objectively and reliably than the existing method is proposed. Previous method measures the reception rate by means of electric field intensity measurement or subjective video quality assessment. Because of limited measuring points, it inherently has measurement error and cannot consider the viewer's receiving conditions in real-time. In order to consider the viewer's population and receiving environment, morphology which characterizes the viewer's receiving environment is extracted using household census data of National Statistical Office and the land cover map of Ministry of Environment. Using the extracted geographical morphology, the reception rate of terrestrial digital TV broadcasting service is calculated with Spectrum Management Intelligence System (SMIs). Proposed method can calculate the reception rate more objectively and reliably than the existing methods because it fully considers the viewer's receiving environments in real-time.

Improvement Measures of Wage Estimation System for Construction Skilled Workers (건설 기능인력의 임금 산정제도 개선방안)

  • Lee, Kun-Hyung;Son, Chang-Baek
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.3
    • /
    • pp.223-233
    • /
    • 2020
  • Problems related to wages in the construction industry, which directly affect the livelihood of workers, have caused other problems in maintaining skilled workers, such as decreasing the inflow of new laborers and increasing the outflow of the existing labor force, which has weakened the foundation of industrial production. Against this backdrop, this study aimed to improve the current wage calculation system in order to increase the inflow of new laborers and maintain the existing skilled workers. It is necessary to differentiate the minimum wage in the construction industry, which requires a high intensity of labor, by industry and occupation type. It is also necessary to establish standards for specifically calculating wages, such as holiday work and overtime pay. The standard of the current retirement mutual aid fund needs to be upwardly adjusted at the same time.

The effect of crack length on SIF and elastic COD for elbow with circumferential through wall crack

  • Kim, Min Kyu;Jeon, Jun Hyeok;Choi, Jae Boong;Kim, Moon Ki
    • Nuclear Engineering and Technology
    • /
    • v.52 no.9
    • /
    • pp.2092-2099
    • /
    • 2020
  • Many damages due to flow-accelerated corrosion and cracking have been observed during recent in-service inspections of nuclear power plants. To determine the operability or repair for damaged pipes, an integrity evaluation related to the damaged piping system should be performed by using already proven code and standards. One of them, the ASME Code Case is most popularly used to integrity assessment in nuclear power plants. However, the recent version of CC N-513 still recommends the simplified method which means a damaged elbow is assumed as an equivalent straight pipe. In addition, to enhance the accuracy integrity assessment in elbow, several previous studies recommend that the SIF and elastic COD values for an elbow with relatively large crack could be predicted by an interpolation technique. However, those estimates for elbow with relatively large crack might be derived to inaccurate results for crack growth analysis, such as for the allowable crack size and life estimation. Therefore, in this paper, the effect of crack length (0.3≤θ1/π≤0.5) on SIF and elastic COD for elbow is systematically investigated. Then, for large crack in elbow, accurate estimates for SIF and elastic COD, which are widely used to assess the integrity of elbows, are proposed. Those proposed solutions are expected to be the technical basis for revisions of CC N-513-4 through the validation.

The Development of Exposure Assessment Tools for Risk Assessment of Volatile Organic Compounds (VOCs의 위해성 평가를 위한 노출분석 방법 연구)

  • Jo, Seong-Joon;Shin, Dong-Chun;Chung, Yong;Lee, Duck-Hee;Breysse, Patrick N.
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.2
    • /
    • pp.147-160
    • /
    • 2002
  • Volatile organic compounds (VOCs) are an important public health issue in Korea and many important questions remain to be addressed with respect to assessing exposure to these compounds. Because they are ubiquitous and highly volatile, special techniques must be applied in their analytic determination Valid Personal exposure assessment methods are needed to evaluate exposure frequency, duration and intensity, as well as their relationship to personal exposure characteristics. Biological monitoring is also important since it may contribute significantly in risk assessment by allowing the estimation of effective absorbed doses. This study was on ducted to establish the environmental measurement, personal dosimetry and biological monitoring methods for VOCs. These methods are needed to compare blood, urinary and exhalation breath VOC levels and to provide tools for risk assessment of VOC exposure. Passive monitors (badge type) and a active samplers (trap) for the VOCs collection were used for air sampling. Methods development included determining the minimum detectable amounts of VOCs in each media, as well as evaluating collection methods and developing analytical procedures. Method reliability was assessed by determining breakthrough volumes and comparing results between laboratories and with other methods. A total capacity of trap used in this study was 60ι. Although variable by compound, the average breakthrough was 20%. Also, there was no loss of compounds in trap even if keep for 45 day in -7$0^{\circ}C$. The recovery of active and passive methods was 69% ~ 126% and method detection limit was 0.24 $\mu\textrm{g}$/trap and 0.07 $\mu\textrm{g}$/badge. There was no statistical difference (P > 0.05) between active and passive methods.

Failure Probability Estimation of Flaw in CANDU Pressure Tube Considering the Dimensional Change (가동중 중수로 압력관의 외경과 두꼐 변화를 고려한 결함의 파손확률 예측)

  • Kwak, Sang-Log;Lee, Joon-Seong;Kim, Young-Jin;Park, Youn-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.11
    • /
    • pp.2305-2311
    • /
    • 2002
  • The pressure tube is a major component of the CANDU reactor, which supports nuclear fuel bundle and heavy water coolant. Pressure tubes are installed horizontally inside the reactor and only selected samples are periodically examined during in-service inspection. In this respect, a probabilistic safety assessment method is more appropriate fur the assessment of overall pressure tube safety. The failure behavior of CANDU pressure tubes, however, is governed by delayed hydride cracking which is the major difference from pipings and reactor pressure vessels. Since the delayed hydride cracking has more widely distributed governing parameters, it is impossible to apply a general PFM methodology directly. In this paper, a PFM methodology for the safety assessment of CANDU pressure tubes is introduced by applying Monte Carlo simulation in determining failure probability Initial hydrogen concentration, flaw shape and depth, axial and radial crack growth rate and fracture toughness were considered as probabilistic variables. Parametric study has been done under the base of pressure tube dimension and hydride precipitation temperature in calculating failure probability. Unstable fracture and plastic collapse are used for the failure assessment. The estimated failure probability showed about three-order difference with changing dimensions of pressure tube.

Inundating Disaster Assessment in Coastal Areas Using Urban Flood Model (도시홍수모델을 이용한 해안지역의 침수재해평가)

  • Yoo Hwan-Hee;Kim Weon-Seok;Kim Seong-Sam
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.24 no.3
    • /
    • pp.299-309
    • /
    • 2006
  • In recent years, a large natural disasters have occurred due to worldwide abnormal weather and the amount of damage has been increased more resulting from high density population and a large-sized buildings of the urbanized area. In this study. we estimate the flooded area according to rainfall probability intensify and sea level in Woreong dong, Masan occurred flood damages by typhoon Maemi using SWMM, a dynamic rainfall-runoff simulation model in urban area, and then analyze the damage of flood expected area through connecting with GIS database. In result, we can predict accurately expected area of inundation according to the rainfall intensity and sea level rise through dividing the study area into sub-area and estimating a flooded area and height using SWMM. We provide also the shelter information available for urban planning and flood risk estimation by landuse in expected flood area. Further research for hazard management system construction linked with web or wireless communication technology expects to increase its application.