• 제목/요약/키워드: integrated data analysis program

검색결과 297건 처리시간 0.03초

Analysis of Combined Yeast Cell Cycle Data by Using the Integrated Analysis Program for DNA chip (DNA chip 통합분석 프로그램을 이용한 효모의 세포주기 유전자 발현 통합 데이터의 분석)

  • 양영렬;허철구
    • KSBB Journal
    • /
    • 제16권6호
    • /
    • pp.538-546
    • /
    • 2001
  • An integrated data analysis program for DNA chip containing normalization, FDM analysis, various kinds of clustering methods, PCA, and SVD was applied to analyze combined yeast cell cycle data. This paper includes both comparisons of some clustering algorithms such as K-means, SOM and furry c-means and their results. For further analysis, clustering results from the integrated analysis program was used for function assignments to each cluster and for motif analysis. These results show an integrated analysis view on DNA chip data.

  • PDF

Program Development of Integrated Expression Profile Analysis System for DNA Chip Data Analysis (DNA칩 데이터 분석을 위한 유전자발연 통합분석 프로그램의 개발)

  • 양영렬;허철구
    • KSBB Journal
    • /
    • 제16권4호
    • /
    • pp.381-388
    • /
    • 2001
  • A program for integrated gene expression profile analysis such as hierarchical clustering, K-means, fuzzy c-means, self-organizing map(SOM), principal component analysis(PCA), and singular value decomposition(SVD) was made for DNA chip data anlysis by using Matlab. It also contained the normalization method of gene expression input data. The integrated data anlysis program could be effectively used in DNA chip data analysis and help researchers to get more comprehensive analysis view on gene expression data of their own.

  • PDF

Software Development on Power and Economic Analysis of Photovoltaic System for Building Application (건물용 태양광발전 시스템 성능 및 경제성 평가 프로그램 개발 연구)

  • Yoon, Jong-Ho;Shin, U-Cheul;Park, Jae-Wan
    • Journal of the Korean Solar Energy Society
    • /
    • 제28권1호
    • /
    • pp.1-8
    • /
    • 2008
  • The aim of this study is to develop the photovoltaic simulation program, called SimPV, which can Predict hourly based power generation of various PV modules and conduct an intensive economic analysis with Korean situation. To establish the reliability of the PV simulation results, we adopt the PV calculation algorithm of TRNSYS program of which verification has already well approved. Extensive database for hourly weather data of Korean 16 cities, engineering data for PV system and building load profiles are established. Case study on the 2.5kW roof integrated PV system and economic analysis are presented with the developed program.

The Basic Study on the Pre-Process Development of Integrated System for the Structural Analysis of Space Frame (스페이스 프레임 구조 해석을 위한 통합 시스템의 전처리 과정 개발을 위한 기초 연구)

  • 권영환;정환목;석창목;김선희
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 한국전산구조공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.378-386
    • /
    • 1999
  • The integrated system for the structural analysis of space frame is made up 4 modules ; pre-process module, structural analysis module, optimum member design module and post-process module. Re-process module of these 4 modules involves data input module and structure modeling module. This study is to develope an efficient modeling program as a basic for development of pre-process module. This modeling program generates geometric information of space frame and performs the input fie form for structure analysis only by input general data. User can mode1 space frame efficiently within shut time by using this program.

  • PDF

Development and Evaluation of Integrated Management Program for Hemodialysis Patients (혈액투석 환자를 위한 통합적 관리 프로그램의 개발 및 효과)

  • Kim, Bora;Yoo, Hana
    • Journal of Home Health Care Nursing
    • /
    • 제31권1호
    • /
    • pp.66-76
    • /
    • 2024
  • Purpose: This study aimed to develop and evaluate an integrated management program to enhance self-efficacy, compliance with sick-role behaviors, symptom management, and biomarker indication in hemodialysis patients. Methods: The integrated management program was developed through a systematic review of literature, analysis of relevant online data, and expert validation. It comprised 480 min of video-based education delivered eight times over four weeks, supplemented by weekly phone consultations and text message support from a nurse. To evaluate the program's effectiveness, it was administered to 44 patients with hemodialysis in a single group in a pre-post test experimental study. Changes in self-efficacy, sick-role behavior compliance, dialysis symptom index, and biomarkers were assessed. Results: The program yielded statistically significant improvements in self-efficacy (t=-7.13, p<.001), sick-role behavioral compliance (t=-7.35, p<.001), dialysis symptom index (t=4.32, p<.001), and blood urea nitrogen levels (t=2.55, p=.014) among the participants. Conclusion: The integrated management program is an effective intervention for improving hemodialysis patients' self-efficacy, compliance with sick-role behaviors, and experience of symptoms. Additionally, it is considered an intervention with high clinical applicability and efficiency through video reproducibility.

Speed Improvement of an FTICR Mass Spectra Analysis Program by Simple Modifications

  • Jeon, Sang-Hyun;Chang, Hyeong-Soo;Hur, Man-Hoi;Kwon, Kyung-Hoon;Kim, Hyun-Sik;Yoo, Jong-Shin;Kim, Sung-Hwan;Park, Soo-Jin;Oh, Han-Bin
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권9호
    • /
    • pp.2061-2065
    • /
    • 2009
  • Two simple algorithm modifications are made to the THRASH data retrieval program with the aim of improving analysis speed for complex Fourier transform ion cyclotron resonance (FTICR) mass spectra. Instead of calculating the least-squares fit for every charge state in the backup charge state determination algorithm, only some charge states are pre-selected based on the plausibility values obtained from the FT/Patterson analysis. Second, a modification is made to skip figure-of-merit (FOM) calculations in the central m/z region between two neighboring peaks in isotopic cluster distributions, in which signal intensities are negligible. These combined modifications result in a significant improvement in the analysis speed, which reduces analysis time as much as 50% for ubiquitin (8.6 kDa, 76 amino acids) FTICR MS and MS/MS spectra at the reliability (RL) value = 0.90 and five pre-selected charge states with minimal decreases in data analysis quality (Table 3).

The Development of Performance Evaluation Program of Building Integrated Photovoltaic System (건물일체형 태양광발전 시스템 성능평가 프로그램 개발)

  • Kim, Beob-Jeon;Park, Jae-Wan;Yoon, Jong-Ho;Shin, U-Cheul
    • KIEAE Journal
    • /
    • 제15권4호
    • /
    • pp.85-90
    • /
    • 2015
  • Purpose: In design and planning Building Integrated Photovoltaic(BIPV) system can reduce cost by replacing building facade as construction material such as roofs, outer walls and windows as well as generating electricity. BIPV system should be applied at the early stage of architectural design. However, it is hard to decide whether using BIPV system or not for architects and builders who are not professional at BIPV system because performance of system is considerably influenced by types of module, installation position, installation methods and so on. It is also hard for experts because commercialized analytical program of photovoltaic systems is too complicated to use and domestic meteorological data is limited to partial areas. Therefore, we need evaluation program of BIPV system which can easily but accurately interpret generating performance and evaluate validity of BIPV system at the early stage of architectural design even for inexpert. Method: In this study, we collected meteorological data of domestic major region and analyzed generation characteristic of BIPV system by using PVsyst(commercialized software) in accordance with regions, types of solar module, place and methods of installation and so on. Based on this data, we developed performance evaluation program of BIPV system named BIPV-Pro, through multiple regression analysis and evaluated its validity. Result: When comparing predictive value of annual average PR and annual electricity production of BIPV-Pro an that of PVsyst, each of root mean square error was 0.01897 and 123.9.

XPERNATO-TOX: an Integrated Toxicogenomics Knowledgebase

  • Woo Jung-Hoon;Kim Hyeoun-Eui;Kong Gu;Kim Ju-Han
    • Genomics & Informatics
    • /
    • 제4권1호
    • /
    • pp.40-44
    • /
    • 2006
  • Toxicogenomics combines transcriptome, proteome and metabolome profiling with conventional toxicology to investigate the interaction between biological molecules and toxicant or environmental stress in disease caution. Toxicogenomics faces the problems of comparison and integration across different sources of data. Cause of unusual characteristics of toxicogenomic data, researcher should be assisted by data analysis and annotation for getting meaningful information. There are already existing repositories which claim to stand for toxicogenomics database. However, those just contain limited abilities for toxicogenomic research. For supporting toxicologist who comes up against toxicogenomic data flood, now we propose novel toxicogenomics knowledgebase system, XPERANTO-TOX. XPERANTO-TOX is an integrated system for toxicogenomic data management and analysis. It is composed of three distinct but closely connected parts. Firstly, Data Storage System is for reposit many kinds of '-omics' data and conventional toxicology data. Secondly, Data Analysis System consists of analytical modules for integrated toxicogenomics data. At last, Data Annotation System is for giving extensive insight of data to researcher.

A study on the Development of Structural Analysis Program using Visual Basic (Visual Basic을 이용한 구조해석 프로그램 개발에 관한 연구)

  • 이상갑;장승조
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 한국전산구조공학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.215-222
    • /
    • 1995
  • The objective of this paper is to develop a finite element structural analysis program using VB(Visual Basic) which has been recently getting popular as development tools of application program for Windows. VB provides several functions to develop an application program easily by supporting event-driven programming method and graphic object as control data type. This system is an integrated processor including preprocessor, solver and postprocessor. Automatic mesh generation is available at preprocess stage, and graphic presentation of deformation and stress is also represented at postprocess one.

  • PDF

Development of Web-based Off-site Consequence Analysis Program and its Application for ILRT Extension (격납건물종합누설률시험 주기연장을 위한 웹기반 소외결말분석 프로그램 개발 및 적용)

  • Na, Jang-Hwan;Hwang, Seok-Won;Oh, Ji-Yong
    • Journal of the Korean Society of Safety
    • /
    • 제27권5호
    • /
    • pp.219-223
    • /
    • 2012
  • For an off-site consequence analysis at nuclear power plant, MELCOR Accident Consequence Code System(MACCS) II code is widely used as a software tool. In this study, the algorithm of web-based off-site consequence analysis program(OSCAP) using the MACCS II code was developed for an Integrated Leak Rate Test (ILRT) interval extension and Level 3 probabilistic safety assessment(PSA), and verification and validation(V&V) of the program was performed. The main input data for the MACCS II code are meteorological, population distribution and source term information. However, it requires lots of time and efforts to generate the main input data for an off-site consequence analysis using the MACCS II code. For example, the meteorological data are collected from each nuclear power site in real time, but the formats of the raw data collected are different from each site. To reduce the efforts and time for risk assessments, the web-based OSCAP has an automatic processing module which converts the format of the raw data collected from each site to the input data format of the MACCS II code. The program also provides an automatic function of converting the latest population data from Statistics Korea, the National Statistical Office, to the population distribution input data format of the MACCS II code. For the source term data, the program includes the release fraction of each source term category resulting from modular accident analysis program(MAAP) code analysis and the core inventory data from ORIGEN. These analysis results of each plant in Korea are stored in a database module of the web-based OSCAP, so the user can select the defaulted source term data of each plant without handling source term input data.