• Title/Summary/Keyword: insulation performance experiment

Search Result 118, Processing Time 0.025 seconds

Partial Discharge Characteristics on Protrusion Defects in SF6-N2 Mixture Gases (SF6-N2 혼합가스 중 돌출 결함의 부분방전 특성)

  • Jo, Hyang-Eun;Wang, Guoming;Kim, Sun-Jae;Park, Kyoung-Soo;Kil, and Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.1
    • /
    • pp.44-49
    • /
    • 2016
  • Studies on a $SF_6$-mixture and -alternative gas has been in progress to reduce the use of $SF_6$ gas as an insulation material of GIS (gas insulated switchgears). In this paper, we dealt with PD (partial discharge) characteristics in pure $SF_6$ and $N_2$, and their mixtures on aspects of insulation design and risk assessment for GIS. A POC (protrusion on conductor) and a POE (protrusion on enclosure) as the major defects were fabricated to simulate PD. We analyzed the DIV (discharge inception voltage), DEV (discharge extinction voltage), pulse magnitude, counts and phase distribution of PD pulse in $SF_6-N_2$ mixtures ($SF_6$ 100%, $SF_6$ 80%-$N_2$ 20%, $SF_6$ 50%-$N_2$ 50%, $SF_6$ 20%-$N_2$ 80%, and $N_2$ 100%) according to the IEC60270. The DIV, DEV as well as magnitude of PD pulse decreased on the POC as increase of $N_2$ ratio. For the POE, the DIV and DEV in $N_2$ ratio below 50% were the same voltages as those in $SF_6$ 100%. In this experiment, $SF_6$ 80%-$N_2$ 20% mixture could be considered with the equivalent insulation performance to a GIS.

Properties of Foamed Concrete According to Types and Concentrations of Foam Agent (기포제 종류 및 희석 농도에 따른 기포 콘크리트의 특성)

  • Kim, Jin-Man;Jeong, Ji-Yong;Hwang, Eui-Hwan;Shin, Sang-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.1
    • /
    • pp.61-70
    • /
    • 2012
  • Recently, the government has been working feverously to save energy and reduce greenhouse gas emission by enacting Basic Act on Low Carbon Green Growth at the national level. Improving the insulation performance of building exterior and insulator can reduce the energy in the building sector. This study is about developing light-weight foamed concrete insulation panel that can be applied to buildings to save energy and to find the optimal condition for the development of insulation materials that can save energy by enhancing its physical, kinetic and thermal characteristics. Various experimental factors and conditions were considered in the study such as foam agent types (AES=Alcohol Ethoxy Sulfate, AOS=Alpha-Olefin Sulfonate, VS=Vegetable Soap, FP=Fe-Protein), foam agent dilution concentration (1, 3, 5%), and foam percentage (30, 50, 70%). Experiment results indicated that the surface tension of aqueous solution including foam agent, was lower when AOS was used over other foam agents. FP produced relatively stable foams in 3% or more, which produced unstable foams containing high water content and low surface tension when diluted at low concentration. Depending on foam agent types, compressive strength and thermal conductivity were similar at low density range but showed some differences at high concentration range. In addition, when concentrations of foam agent and foaming ratio increased, pore size increased and open pores are formed. In all types of foam agent, thermal conductivity were excellent, satisfying KS standards. The most outstanding performance for insulation panel was obtained when FP 3% was used.

Characterization of Insulation Finish Material Using Inorganic Wet Treatment Fly Ash (무기성 습식 처리 플라이애시를 활용한 단열 외피 마감재의 특성 평가)

  • Ryu, Hwa-Sung;Shin, Sang-Heon;Song, Sung-Young;Kim, Deuak-Mo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.4
    • /
    • pp.389-394
    • /
    • 2019
  • In this study, a functional inorganic insulation as TiO2 and inorganic wet fly ash were used to evaluate the physical performance and thermal environment of an exterior finish that can improve the thermal environment of a building. The performance evaluation of the finish was based on the KS F 4715 thin coating material and the thermal environment. When TiO2 was added, the physical performance was lowered at 10% or more, and the inorganic wet-treated fly ash increased the physical performance by 10%. In the thermal environmental evaluation, the surface temperature reduction effect of the inorganic wet-treated fly ash was low, but when used in combination with TiO2, it was effective to reduce the surface temperature and the internal temperature. As a result, the optimum combination of TiO2 and inorganic wet-treated fly ash for thermal environment control was found to be optimal when 5% of each mixture was used.

A Study on the Four-Season Cooling Performance by Color of Water Proofing Membrane Materials Considering the View of Area (지역의 경관을 고려한 도막방수재의 색채별 사계절 차열 및 축열 성능에 관한 연구)

  • Ko, Jin-Soo;Kim, Byung-Yun
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.17 no.2
    • /
    • pp.9-16
    • /
    • 2015
  • This study comparatively analyzed thermal characteristics of the green color, which is currently used the most, and other various colors of a rooftop urethane water proofing sheet. This study also analyzed the cooling performance by color of the water proofing sheet that fused cooling paints, and presented the effective water proofing sheet color for building energy savings. The experimental results are as follows: (1) The value of L (brightness) diminished, and brilliance also became lower from the white color to the black color, and thus, it was confirmed that relatively more heat was absorbed. In a and b chromaticity, which is the color attribute that ignores brightness, no special relationship was identified. (2) Considering that the cooling performance effect is bigger in summer than winter, due to heat reflection, the white water proofing sheet is more effective in building energy savings than the green water proofing sheet that is currently used the most. (3) The water proofing sheet's color has an impact more on cooling performance than the color of the background side of a structure on which water proofing sheet is installed. The experiment object of gray, of which background side is similar to cement mortar, was lower by $5.7^{\circ}C$ than the white background side.

Development of Small Distillation Column for Performance Evaluation of Distillation Column (증류탑 성능평가에 적합한 소형 증류탑 개발)

  • Kim, Byoung Chul;Cho, Tae Je;Kim, Young Han
    • Korean Chemical Engineering Research
    • /
    • v.48 no.5
    • /
    • pp.668-671
    • /
    • 2010
  • A lab scale distillation experiment is conducted with small size packing used in lab scale multi-tray distillation equipment for the performance evaluation of distillation system. A sufficient surface are yielded with 6.7 mm cylindrical packings made of stainless steel, and a good liquid holdup and residence time are resulted. The comparison between the theoretical tray from the HYSYS and the experimental distillation outcome indicates that a 7 cm HETP from 27 cm packing height and a 8 cm HETP from 45 cm packing height are obtained. Comparing with the 8 cm HETP of commercial structured packing shows a similar experimental results obtained here. The 7 cm HETP is available with a complete insulation, and the importance of the insulation is proved. The results of this study indicates that a practical distillation column used in field can be tested in lab.

A Study of Dry-Wall Performance Evaluation - An Alternative to Korean Traditional Mud Walling - (전통주택 흙벽을 대신할 수 있는 건식벽체 성능평가에 관한 연구)

  • Hwang, Yong-Woon
    • Journal of the Korean housing association
    • /
    • v.22 no.6
    • /
    • pp.61-69
    • /
    • 2011
  • Korea's traditional house type, the Hanok, has been the essence of Korean domestic culture for hundreds of years. However, Hanok, have begun to disappear as result of urbanization. Because mud walls are crude and weak in water walls are also easily broken by impact. There are further problems in that construction cost is expensive and takes more time than modern house construction, and that the maintenance of Hanok is more difficult than people sometimes predict. Despite much interest in Hanok construction, there is a lack of in younger generation. Thus seeking new ways of maintaining Korea's traditional housing culture and extending Korean traditional houses is important. This study proposes directions for creating new residential environments for the future generation of Korea. A Dry-wall alternative to the Korean traditional mud wall is particularly needed. Dry-walling, made by sustainable materials such as mud board and wood, can strengthen the advantages and make up for the weaknesses of the Korea traditional mud wall. In this study, both wall types underwent various evaluations in terms of their performance in insulation testing, freezing and thawing testing, impacting testing and weight measuring (the size of material in this experiment was $69cm{\times}105cm$). On all of these tests, findings revealed that the dry-wall alternative performed better than traditional mud wall.

Estimation of Heat Insulation and Light Transmission Performance According to Covering Methods of Plastic Greenhouses (플라스틱온실의 피복방식에 따른 보온 및 광투과 성능 평가)

  • Lee, Hyun-Woo;Kim, Young-Shik;Sim, Sang-Youn;Lee, Jong-Won;Diop, Souleymane
    • Journal of Bio-Environment Control
    • /
    • v.22 no.3
    • /
    • pp.270-278
    • /
    • 2013
  • The objective of the present study is to provide data needed to decide covering method to be able to increase the thermal insulation and light transmittance efficiency of commercial greenhouse. The thermal insulation effect, PPF transmittance and quantity of condensation water were estimated in experimental tomato greenhouses covered with three types of coverings of single layer, air inflated and conventional double layers covering. The overall heat flow of air inflated double layers greenhouse was similar to that of conventional double layers greenhouse, but the temperature between covering material and thermal screen in air inflated double layers greenhouse was lower than that in conventional double layers greenhouse at the same outside temperature condition due to air leakage through the gap of roof vent. The overall heat transfer coefficients acquired by experiment that was performed in single layer and conventional double layers greenhouses were close to those obtained from model experiment. Even though the PPF transmittance of air inflated double layers greenhouse was lower than that of single layer greenhouse, which was greater than that of conventional double layers greenhouse. The quantity of condensation water on covering surface of single layer greenhouse was greater than that of air inflated double layers greenhouse due to lower covering surface temperature.

The Design and Experiment of a Planar Patch Sensor for Partial Discharge Diagnostics in 6.6 kV Rotating Machine Stator Windings

  • Yang, Sang-Hyun;Park, Noh-Joon;Park, Dae-Hee;Kim, Hee-Dong;Lim, Kwang-Jin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.5
    • /
    • pp.173-176
    • /
    • 2009
  • In the stator windings of a 6.6 kV rotating machine, internal discharges, slot discharges, and surface discharges are mainly caused by internal voids and insulation degradation. If a partial discharge(PD) occurs in an inner-part of the stator windings, it will cause electromagnetic pulses with wide frequency ranges. Discharge sparks and electromagnetic pulses generated from a discharge source, can be detected using various RF resonators like an EM sensor. In order to detect these types of electromagnetic sources, a planar patch sensor was designed and fabricated using a CST-MWS simulation, and PD signals from an artificially defected stator winding were also measured by the sensor proposed in this study. Furthermore, an HFCT was used as a reference sensor and compared with the proposed new planar patch sensor. In the results of the experiment, the planar patch sensor showed a similar performance to the HFCT sensor.

회전기 고정자권선의 부분방전 진단용 평면 패치센서의 설계 및 실험

  • Yang, Sang-Hyeon;Park, No-Jun;Kim, Chung-Sik;Park, Dae-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.228-228
    • /
    • 2009
  • In stator windings of a 6.6kV rotating machine, internal discharge, corona discharge, and surface discharge are mainly caused by internal voids and insulation degradation. In the case of the discharge spark and electromagnetic pulse generated from a discharge source, we can detect it using various RF resonators like an EM sensor. In order to detect these types of electromagnetic sources, we designed and fabricated a planar patch sensor using a CST-MWS simulation, and PD signals from artificial defected stator windings were also measured by the sensor proposed in this study. Furthermore, In the results of the experiment, it showed similar performance to the HFCT sensor.

  • PDF

Acoustic Modal Property of a Vehicle Passenger Compartment including Head Liner (헤드라이너를 포함한 승용차의 차실의 음향모드 특성)

  • Kim, Seock-Hyun;Lee, Jin-Woo
    • Journal of Industrial Technology
    • /
    • v.22 no.A
    • /
    • pp.43-48
    • /
    • 2002
  • Acoustic modes of a vehicle compartment dominate the noise characteristics of the vehicle system in the low frequency range. Vehicle compartments have head liner and air gap of proper thickness to mount a interior lamp, as well as to have a good sound insulation and absorption performance. This study estimates the acoustic modal property of the medium size passenger car by experiment and by finite element analysis and also, investigates the effect of the head liner on the acoustic mode of the passenger compartment to obtain useful information for low noise compartment design.

  • PDF