• Title/Summary/Keyword: instantaneous parameters

Search Result 221, Processing Time 0.029 seconds

The Torque-current Observer Design for Speed.Torque Control of DC Motor (직류 전동기 속도.토크 제어에 대한 토크전류 관측기 설계)

  • Kim, Eun-Gi;Kim, Yong-Ju;Seo, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1091-1093
    • /
    • 2002
  • In this paper, the load torque observer is designed for speed and torque control of DC motor. Load torque is very sensitive to the variation and disturbance of the input parameters. The proposed system can accurately estimate the instantaneous speed even at the low speed range by using the load torque observer based on the torque component of DC motor. The system becomes robust against disturbances using a feed-forward control of the load torque estimated automatically at the speed observer.

  • PDF

A Continuous Review(s, S) Inventory Model in which Depletion is Due to Demand and Loss of Units

  • Choi, Jin-Yeong;Kim, Man-Sik
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.11 no.1
    • /
    • pp.33-39
    • /
    • 1985
  • A stochastic model for an inventory system in which depletion of stock takes place due to random demand as well as random loss of items is studied under the assumption that the intervals between successive unit demands, as well as those between successive unit losses are independently and identically distributed random variables having negative exponential distribution with respective parameters. We have derived the steady state probability distribution of the stock level assuming instantaneous delivery of order under (s, S) inventory policy. Also we have derived total expected cost expression and the necessary conditions to be satisfied for an optimal solution.

  • PDF

Estimation of Longitudinal Vibration Using Transverse Vibration of a String Subject to Parametric Oscillation (매개변수가진에 종속되는 현의 횡방향 진동을 이용한 종방향 진도의 추정)

  • 김도균;김광준
    • Journal of KSNVE
    • /
    • v.4 no.3
    • /
    • pp.365-375
    • /
    • 1994
  • Periodic longitudinal vibrations of a video and audio tape and the like used for transducing pictures and sounds may be induced by self-excited vibrations which are caused by frictions against the heads and guides, and their eccentricity, noncircularity or irregularity. It is important to analyze the longitudinal vibration of a tape because it causes distortions of a reproduced signal. It is difficult to measure directly the longitudinal vibration. In this paper a method estimating longitudinal vibration using impulse responses in the transverse direction is presented. And, the parameters boundary domain where the transverse and longitudinal vibration can be decoupled is introduced. In the domain where the both vibrations are decoupled, analytic methods using frequency characteristics and transient responses of the transverse vibration, respectively, are presented. The time domain method predicted more exactly the instantaneous phase of the longitudinal vibration than frequency domain method did.

  • PDF

Measurement of Flow Ripple Generated by Balanced Vane Pumps in Automotive Power Steering Systems (동력조향용 압력평형형 베인펌프의 유량맥동 계측)

  • Kim, Do-Tae;Kim, Jin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.6
    • /
    • pp.70-78
    • /
    • 2000
  • A balanced vane pump for the use of automotive power steering systems generates a flow ripple which is imposed upon the mean flow rate. The flow ripple interacts with the characteristics of the connected pipes, valves and steering gear in a complex manner to produce a pressure ripple, also known as fluid-borne noise. In order to reduce vibration level and produce quieter and more reliable power steering systems, it is important to measure the flow ripple produced by a pump with high accuracy and fast response. In this paper, the flow ripple generated by a vane pump in automotive power steering systems is measured by the remote instantaneous flow rate measurement method (RIFM) using hydraulic pipeline dynamics. In experiment, flow and pressure ripple wave forms are measured under various operating conditions. Also, the parameters affected upon the flow and pressure ripple are investigated by the frequency analysis.

  • PDF

Leakage Inductance Estimation of $Y-\triangle$ Transformer Using the Least Square Method (최소자승법을 이용한 $Y-\triangle$ 누설 인덕턴스 추정 방법)

  • Hwang, Tae-Keun;Lee, Byung-Eun;Jang, Sung-Il;Kim, Yong-Gyun;Kang, Yong-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.645-650
    • /
    • 2007
  • This paper proposes a parameter estimation technique of a power transformer. Based on the combined equation, it estimates separately the primary and secondary leakage inductances using the least square method from the instantaneous voltages and currents in the steady state. The performance of the proposed technique was investigated by varying the cut-off frequency of the filter and the number of samples per cycle. The estimated values are obtained based on the average value for 41 cycle.

RADIO FREQUENCY INTERFERENCE FROM FDM-FM SIGNALS ON QAM SIGNAL - DATA IN VOICE CASE - (QAM 신호에 대한 FDM-FM 신호의 간섭 영향 - Data In Voice의 경우-)

  • Ko, Bong-Jin;Cho, Sung-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.864-868
    • /
    • 1987
  • In this paper we have Investigated the effects of two wideband FDM-FM signals on n-ary QAM signal allocated between FDM-FM signals (in DIV case). Here, we assumed that the instantaneous frequency distribution of wideband FDM-FM signal is Gaussian. The numerical results of symbol error rate are given in graphs as the parameters of carrier to noise ratio (CNR), carrier to interference ratio (CIR) and normalized carrier separation between QAM and FDM-FM carrier frequencies.

  • PDF

3D SIMULATION OF FLAPPING FLAGS IN A UNIFORM FLOW BY THE IMMERSED BOUNDARY METHOD

  • Huang, Wei-Xi;Sung, Hyung-Jin
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.10a
    • /
    • pp.141-148
    • /
    • 2007
  • We present an immersed boundary (IB) method for 3D simulation of flappingflags in a uniform flow. The proposed formulation is manipulated on the basis of an efficient Navier-Stokes solver adopting the fractional step method and a staggered Cartesian grid system. A direct numerical method is developed to calculate the flag motion, with the elastic force treated implicitly. The fluid motion defined on an Eulerian grid and the flag motion defined on a Lagrangian grid are independently solved and the mass of flag is handled in a natural way. An additional momentum forcing is formulated from the flag motion equation in a way similar with the direct-forcing IB formulation and acts as the interaction force between the flag and ambient fluid. A series of numerical tests are performed and the present results are compared qualitatively and quantitatively with previous studies. The instantaneous flag motion is analyzed under different conditions and surrounding vortical structures are identified. The effects of physical parameters on the flapping frequency are studied.

  • PDF

An experimental approach for estimating the porosity and effective porosity of porous media by permittivity methods

  • Nishigaki M.;Komatsu M.;Kim M.-I.
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.703-710
    • /
    • 2003
  • In the sub-surface environments, detection of the movement of contaminant substances and recharge of groundwater by rainfall are very important factors which contain porosity and effective porosity of porous media. In this paper, the applicability of permittivity methods and proposed dielectric mixing models (DDMs) are discussed. This study showed that the ratio of effective porosity to porosity of Toyoura and River sands were 0.856 and 0.843. From the relationships between the relative porosity and effective porosity, all measured values can be confirmed to outside the range to about 0.800 for Toyoura and River sands under all experiments by FDR and FDR-V systems. In the study, this permittivity equipment can be considered to be good enough to measure determining the physical parameters of saturated soils. Consequently, this permittivity method can be contributed to estimate a porosity and effective porosity of saturated porous media because it is easy and instantaneous than previous in-situ methods.

  • PDF

Experimental Study on Single Bubble Growth Under Subcooled, Saturated, and Superheated Nucleate Pool Boiling

  • Kim Jeong-Bae;Lee Jang-Ho;Kim Moo-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.692-709
    • /
    • 2006
  • Nucleate pool boiling experiments with constant wall temperature were performed using pure R1l3 for subcooled, saturated, and superheated pool conditions. A microscale heater array and Wheatstone bridge circuits were used to maintain the constant wall temperature and to measure the instantaneous heat flow rate accurately with high temporal and spatial resolutions. Images of bubble growth were taken at 5,000 frames per second using a high-speed CCD camera synchronized with the heat flow rate measurements. The bubble geometry was obtained from the captured bubble images. The effect of the pool conditions on the bubble growth behavior was analyzed using dimensionless parameters for the initial and thermal growth regions. The effect of the pool conditions on the heat flow rate behavior was also examined. This study will provide good experimental data with precise constant wall temperature boundary condition for such works.

A Nonlinear Observer Design for P-Cells Chopper

  • Benmansour, K.;Bouchhida, O.;Tlemcani, A.;Leon, J. De;Djemail, M.
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.4
    • /
    • pp.580-591
    • /
    • 2010
  • This paper deals with an observer design for a P-Cell Chopper. The goal is to reduce drastically the number of sensors in such system by using an observer in order to estimate all the capacitor voltages. Furthermore, considering an instantaneous model of a p-cell chopper, an interconnected observer is designed in order to estimate the capacitor voltages and some parameters of the model. This is realized by using only the load current measurement. Simulation results are given in order to illustrate the performance of such observer. To show the validity of our approach, experimental based a DSP results are presented.