• Title/Summary/Keyword: instantaneous frequency

Search Result 338, Processing Time 0.024 seconds

Control of Electrically Excited Synchronous Motors with a Low Switching Frequency

  • Yuan, Qing-Qing;Wu, Xiao-Jie;Dai, Peng;Fu, Xiao
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.615-622
    • /
    • 2012
  • The switching frequency of the power electronic devices used in large synchronous motor drives is usually kept low (less than 1 kHz) to reduce the switching losses and to improve the converter power capability. However, this results in a couple of problems, e.g. an increase in the harmonic components of the stator current, and an undesired cross-coupling between the magnetization current component ($i_m$) and the torque component ($i_t$). In this paper, a novel complex matrix model of electrically excited synchronous motors (EESM) was established with a new control scheme for coping with the low switching frequency issues. First, a hybrid observer was proposed to identify the instantaneous fundamental component of the stator current, which results in an obvious reduction of both the total harmonic distortion (THD) and the low order harmonics. Then, a novel complex current controller was designed to realize the decoupling between $i_m$ and $i_t$. Simulation and experimental results verify the effectiveness of this novel control system for EESM drives.

Active One-Way Ranging Method based on Post-Facto Wireless Synchronization in Wireless Sensor Networks (무선 센서망에서의 사후 무선동기 기반 능동형 단반향 거리추정 방식)

  • Nam, Yoon-Seok;Bae, Byoung-Chul
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.5 no.4
    • /
    • pp.234-242
    • /
    • 2010
  • Two-way ranging methods such as TWR and SDS-TWR have been considered for many ranging systems because these methods are useful in the absence of synchronization. To estimate the location of a mobile node, complicated ranging procedures consisting of ranging frames between an anchor node and the mobile node are performed. Supporting multiple mobile nodes such as a few hundreds or thousands and several anchor nodes, the ranging procedures have the fatal disadvantage of processing delay and inefficient traffic bandwidth. On the other hand, the one-way ranging method is simple and fast, but susceptible to network synchronization. In this paper, we propose a method to modify asynchronous ranging equations to establish exact frequency or frequency offset, a method to estimate frequencies or frequency offsets, and a method to establish post-facto synchronization with anchor nodes. The synchronization for a node pair is adapted using instantaneous time information and corresponding difference of distances can be determined. We evaluate the performance of TWR, SDS-TWR and proposed ranging algorithms.

3-Phase RMS Voltage Measurement Method of Virtual Frequence using Instantaneous Power Component Concept (순시전력 합성 개념을 이용한 가상주파수 3상 실효전압 계측기법)

  • Park, Seong-Mi;Yang, Ji-Hoon;Park, Sung-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.3
    • /
    • pp.251-257
    • /
    • 2019
  • This paper proposes a new measurement method using virtual power concept to measure the effective value of 3-phase voltage with variable frequency. The conventional effective value measurement method uses a method of integrating data sampled during one or half cycle of the power voltage and averaging it. In this method, since the effective voltage is calculated every cycle, a time delay occurs in the measured effective voltage and it is s a problem to measure the effective value of a device whose frequency varies from time to time, such as a generator. The proposed 3-phase voltage rms measurement method has an advantage that it can measure accurate voltage RMS value regardless of measurement frequency variation. In particular, there is an advantage in that it is possible to measure a 3-phase effective voltage rather than an average value of the effective voltage of each phase in a 3-phase unbalance voltage. In addition, the validity of the proposed method is verified by using the Psim simulation tool and the experimental results are analyzed by applying the proposed measurement algorithm to the actual three phase synchronous generator voltage measurement experiment.

A Characteristic Analysis of Instantaneous Voltage Resultant Control-Based Double Full-Bridge High Frequency Inverter (순시전압 합성제어형 2중 풀 브릿지 고주파 인버터 특성 해석)

  • Jung, Won-Young;Kim, Sung-Chul;Min, Byung-Jae;Nam, Seung-Sig;Ro, Chae-Cyun
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.492-494
    • /
    • 1996
  • This paper describes a study on the series resonant inverter using the double full-bridge, and the output voltage of the proposed inverter is controlled by phase shift angle of the outputs of two inverters. These control schemes can be reduce the switching loss and EMI, etc, which the inverter is drived by auto following control of output frequency, because it is impossible for switching devices to be always turned on and off at zero voltage or zero current. Theoretical characteristics of the proposed double inverter circuit are compared with Pspice simulation and experimental results.

  • PDF

A New Scheme for Maintaining Balanced DC Voltages in Static Var Compensator(SVC) Using Cascade Multilevel Inverter

  • Min, Wan-Ki;Min, Joon-Ki;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.561-565
    • /
    • 2001
  • This paper proposes a new switching scheme of a static var compensator(SVC) with cascade multilevel inverter which employs H-bridge inverter(HBI). To improve the un­balanced problem of the DC capacitor voltages, the rotated switching scheme of fundamental frequency is newly used. The optimized fundamental switching pattern with low switching frequency is adapted to be suitable for high application. The selective harmonic elimination method(SHEM) allows to keep the total harmonic distortion(THD) low in the output voltage of multilevel inverter. The SVC system is modeled using the d-q transform which calculates the instantaneous reactive power. This model is used to design a controller and analyze the SVC system. Simulated and experimental results are also presented and discussed to validate the proposed schemes.

  • PDF

An Effective x-dB Bandwidth Measurement Method of FM Signals using moving Average (동적 평균을 이용한 FM 신호의 효율적인 x-dB 대역폭 측정방법)

  • 김영수;유익한;조병모
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.7
    • /
    • pp.1233-1239
    • /
    • 2000
  • In this paper, a new approach is proposed for effectively estimating the occupied bandwidth of frequency modulation (FM) signals. The proposed method makes use of the smoothing niter for removing the perturbation of spectrum envelope, which frequently occurs in FM signals having the instantaneous frequency. An effective procedure is derived for finding the relatively accurate bandwidth of FM signals combined with x-dB bandwidth measurement method, which International Telecommunication Union-Radiocommunication (ITU-R) recommended. It was shown that the proposed approach provides superior performance relative to the one obtained with the x-dB bandwidth measurement method in terms of sample bias and mean squared error of bandwidth estimates.

  • PDF

Estimation of Longitudinal Vibration Using Transverse Vibration of a String Subject to Parametric Oscillation (매개변수가진에 종속되는 현의 횡방향 진동을 이용한 종방향 진도의 추정)

  • 김도균;김광준
    • Journal of KSNVE
    • /
    • v.4 no.3
    • /
    • pp.365-375
    • /
    • 1994
  • Periodic longitudinal vibrations of a video and audio tape and the like used for transducing pictures and sounds may be induced by self-excited vibrations which are caused by frictions against the heads and guides, and their eccentricity, noncircularity or irregularity. It is important to analyze the longitudinal vibration of a tape because it causes distortions of a reproduced signal. It is difficult to measure directly the longitudinal vibration. In this paper a method estimating longitudinal vibration using impulse responses in the transverse direction is presented. And, the parameters boundary domain where the transverse and longitudinal vibration can be decoupled is introduced. In the domain where the both vibrations are decoupled, analytic methods using frequency characteristics and transient responses of the transverse vibration, respectively, are presented. The time domain method predicted more exactly the instantaneous phase of the longitudinal vibration than frequency domain method did.

  • PDF

Effect of Adjustable Speed Pumped Storage Power Generator on the Frequency Control Against the Intermittence of Wind Turbine Output (풍력발전기 출력변동성에 대비한 가변속 양수발전기의 주파수 제어효과)

  • Park, Min-Su;Chun, Yeong-Han
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.338-342
    • /
    • 2014
  • Energy storage is a key issue when integrating large amounts of intermittent and non-dispatchable renewable energy sources into electric power systems. To maintain the instantaneous power balance and to compensate for the influence of power fluctuations from renewable sources, flexible capability for power control is needed. Adjustable Speed Pumped Storage Power Generator is pumped storage unit that is adjustable for pump output adjustments as well as the highest efficiency operations because it has fast response time. In this paper we address the adjustable speed pumped storage power generator for frequency control against the intermittence of wind turbine output and calculate the appropriate capacity of adjustable speed pumped storage power generator.

RADIO FREQUENCY INTERFERENCE FROM FDM-FM SIGNALS ON QAM SIGNAL - DATA IN VOICE CASE - (QAM 신호에 대한 FDM-FM 신호의 간섭 영향 - Data In Voice의 경우-)

  • Ko, Bong-Jin;Cho, Sung-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.864-868
    • /
    • 1987
  • In this paper we have Investigated the effects of two wideband FDM-FM signals on n-ary QAM signal allocated between FDM-FM signals (in DIV case). Here, we assumed that the instantaneous frequency distribution of wideband FDM-FM signal is Gaussian. The numerical results of symbol error rate are given in graphs as the parameters of carrier to noise ratio (CNR), carrier to interference ratio (CIR) and normalized carrier separation between QAM and FDM-FM carrier frequencies.

  • PDF

Frequency Dependent Equivalent System for Electromagnetic Transient Simulation (전자기 과도현상 시뮬레이션을 위한 주파수 의존 등가 시스템 개발)

  • Han, Hyeng-J.;Lee, Chul-Y.;Wang, Yong-P.;Chong, Hyeng-H.;Kim, Sang-H.;An, Byung-C.;Kim, Hae-J.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.202-204
    • /
    • 2005
  • This paper presents the formulation for developing 2 port Frequency Dependent AC System Equivalent(FDACSE) with the instantaneous term in 5-domain and illustrates its use. This 2 port FDNE have been applied to the New Zealand AC system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the 2 port (FDACSE) developed with Norton Equivalent network. The study results have indicated the robustness and accuracy of 2 port FDACSE for electromagnetic transient studies.

  • PDF