• Title/Summary/Keyword: instantaneous following control

Search Result 19, Processing Time 0.022 seconds

The Buck DC-DC Convener with Non-Linear Instantaneous Following PWM Control Method (비선형 순시추종형 PWM 제어기법을 적용한 강압형 DC-DC 컨버터)

  • 김상돈;라병훈;이현우;김광태
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.2
    • /
    • pp.73-80
    • /
    • 2003
  • This Paper Proposes instantaneous following control method to control pulse modulation switching converter by using principle that reset time of integrator is inverse proportion in size of integrator input voltage. proposed control method acts of fixed frequency and control switch calculates time of become turn on and turn off using analog integrator. Duty ratio that express switching time of converter is depended on mean value of switching variable and following time consists in one cycle. Follow to do order exactly stationary state as well as transition state, and controller corrects mean value of control variable and control reference value and control as control error gets into zero. Proposed control method could experimented and know that experiment result and theory are agreeing well through this using the buck converter.

The Buck DC-DC Converter with Non-Linear Instantaneous Following PWM Control Method (비선형 순시추종형 PWM 제어기법을 적용한 강압형 DC-DC 컨버터)

  • Kim Sang-Don;Ra Byung-Hun;Lee Hyun-Woo;Kim Kwang-Tae
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.470-475
    • /
    • 2002
  • Instantaneous following PWM control technique is pulsed nonlinear dynamic control method. This new control technique using analog integrator is proposed to control the duty ratio D of do-dc converter. In this control method, the duty ratio of a switch is exactly equal In or proportional to the control reference in the steady state or in a transient. Proposed control method compensates power source perturbation in one switching cycle, and the average value of the dynamic reference in one switching cycle. There is no steady state error nor dynamic error between the control reference and the average value of the switched variable. Experiments with buck converter have demonstrated the robustness of the control method and verified theoretical prediction. The control method is very general and applicable to all type PWM

  • PDF

Instantaneous Following PWM Control Strategy of Cuk Converter Using Integrator (적분기를 이용한 Cuk 컨버터의 순시추종형 PWM 제어)

  • Shon, Je-Bong;Jeong, Soon-Yang;Kim, Kwang-Tae;Lee, Woo-Seok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.103-105
    • /
    • 2002
  • Instantaneous following PWM control technique is pulsed nonlinear dynamic control method. This new control technique using analog integrator is proposed to control the duty ratio D of Cuk converter. In this control method, the duty ratio of a switch is exactly equal to or proportional to the control reference in the steady state or in a transient. Proposed control method compensates power source perturbation in one switching cycle, and the average value of the dynamic reference in one switching cycle. There is no steady state error nor dynamic error between the control reference and the average value of the switched variable. Experiments with Cuk converter have demonstrated the robustness of the control method and verified theoretical prediction. The control method is very general and applicable to all type PWM.

  • PDF

Characteristic Analysis of Buck Converter by using the Non-Linear Instantaneous Following PWM Controller (강압형 컨버터의 비선형 순시추종 PWM 제어기의 특성 분석)

  • Ra, Byung-Hun;Kim, Sang-Don;Kwon, Soon-Kurl;Lee, Hyun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.378-381
    • /
    • 2002
  • Instantaneous following PWM control technique is pulsed nonlinear dynamic control method. This new control technique using analog integrator is proposed to control the duty ratio D of DC-DC converter. In this control method, the duty ratio of a switch is exactly equal to or proportional to the control reference in the steady state or in a transient. Proposed control method compensates power source perturbation in one switching cycle, and the average value of the dynamic reference in one switching cycle. There is no steady state error nor dynamic error between the control reference and the average value of the switched variable. Experiments with buck converter have demonstrated the robustness of the control method and verified theoretical prediction. The control method is very general and applicable to all type PWM.

  • PDF

Instantaneous Following Control of Half-Bridge DC-DC Converter (하프브리지 DC-DC 컨버터의 순시추종제어)

  • Ra B.H.;Lee H.W.;Kim S.D.;Kim K.T.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.54-57
    • /
    • 2003
  • A new non linear, mean value, instantaneous following control technique to design half bridge converter is proposed in witch control principle uses characteristic that reset time of analog integrator is inverse proportion In input voltage. It is Important characteristic that compensation and follow-up control time are same with switching frequency. Is completed in one cycle that base control frequency. Have excellence characteristic that follow in order instruction value exactly stationary state as well as transient state. Half bridge converter that apply this control principle can know that have stabilize and excellence characteristic. This technique is verified through an experiment, and know that experiment result and theory agree well.

  • PDF

Ripple Voltage Compensation Instantaneous Follow Controller of Inverter by using Analog Integrator (아날로그 적분기를 이용한 맥동전압 보상형 순시추종 PWM 제어기를 적용한 인버터)

  • 라병훈;이현우;김광태
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.381-389
    • /
    • 2004
  • In this paper, it is suggested that instantaneous compensation PWM control for inverter without the smoothing capacitor Therefore, this inverter system has several advantages. It has small volume and low price to manufacture, decrease trouble rate of inverter, and has power factor correction effect because huge smoothing capacitor-less. And it has compact size control circuit to use analog integrator device. It could make the smoothing capacitor-less inverter for air-blower motor by using the instantaneous compensation PWM controller. This inverter system has small volume and value compare with the conventional VVVF control inverter.

Instantaneous Following PWM Control of Inverter for Blower Motor (브로워용 전동기 인버터의 순시추종 PWM 제어)

  • Ra B. H.;Kwon S. K.;Lee H. W.;Chun J. H.;Kim K. T.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.275-278
    • /
    • 2003
  • Conventional vector control inverter is usually used for blower of air-accord equipment. In this paper, it is proposed that inverter is controlled by instantaneous following PWM controller. This controller compensate and follow for output voltage of inverter within one switching cycle as an error that compared output voltage of rectifier included much ripples with reference voltage of sine wave. It has not speedy response like vector controller, but the circuit is very simple as using analog integer. And it has advantages that develop input power factor, built small-capacity and low-cost because huge capacitor of voltage type inverter removed.

  • PDF

A Characteristic Analysis of Instantaneous Voltage Resultant Control-Based Double Full-Bridge High Frequency Inverter (순시전압 합성제어형 2중 풀 브릿지 고주파 인버터 특성 해석)

  • Jung, Won-Young;Kim, Sung-Chul;Min, Byung-Jae;Nam, Seung-Sig;Ro, Chae-Cyun
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.492-494
    • /
    • 1996
  • This paper describes a study on the series resonant inverter using the double full-bridge, and the output voltage of the proposed inverter is controlled by phase shift angle of the outputs of two inverters. These control schemes can be reduce the switching loss and EMI, etc, which the inverter is drived by auto following control of output frequency, because it is impossible for switching devices to be always turned on and off at zero voltage or zero current. Theoretical characteristics of the proposed double inverter circuit are compared with Pspice simulation and experimental results.

  • PDF

A STUDY ON SIMULATION OF THE MANDIBULAR MOVEMENT OF THE PATIENTS WITH TEMPOROMANDIBULAR JOINT DISORDER (측두하악 장애환자의 하악 운동 Simulation에 관한 연구)

  • Park, Sang-Yoon;Kang, Dong-Wan;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.161-175
    • /
    • 1991
  • To understand the biomechanics of the mandibular movement of the patients with T.M.J. disorder, it is necessary to analyze the mandibular movement by the least moving points of instantaneous center of rotation on computer screen. In this study, two subjects without T.M.J. disorder and with normal occlusion and few patients with T.M.J. disorder were selected for obtaining the processing data. The habitual opening and dosing movements were recorded by image recognition system of video and computer and then the mandibular movement and the least moving point were analyzed using computer program for image anaysis of specialized points. The results obtained were as follows: 1. The least moving points of control group during opening and dosing were dose to the mandibular foramen, but in the test group there were differences between two positions of the least moving points during opening and closing. 2. The variations of the least moving point were in the range of $0.02\sim0.05cm$ of X-coordinate and $0.07\sim0.10cm$ of Y-coordinate for control group, whereas in the range of $0.05\sim0.30cm$ of X-coordinate and $0.08\sim1.65cm$ of Y-coordinate for test group. 3. The index of variation during opening and dosing movements was shown in $0.8\sim1.0$ for the control group and in $0.56\sim2.6$ for the test group. 4. After the treatment of the test group No. 4 by occlusal splint the least moving point was dose to the mandibular foramen and the index of variation was changed from 25 to 05. 5. The tracing shape of the least moving point in the test group represented the irregularities compared to the control group. 6. The mandibular opening and dosing movements were simulated on the computer screen following the movement of the least moving point of instantaneous center of rotation.

  • PDF

Analysis of Car Following Model of Adaptive Cruise Controlled Vehicle Considering the Road Conditions According to Weather Circumstance (기상상황에 따른 노면상태를 고려한 첨단차량 추종거동 모형의 분석)

  • Kim, Tae-Uk;Bae, Sang-Hoon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.3
    • /
    • pp.53-64
    • /
    • 2013
  • The car-following model is one of core models in Advanced Vehicle & Highway Systems (AVHS). The car-following model has been developed in aspects such as human factor and reduction error rates. However, the consideration of safety depending on weather condition has not been completed yet. In this paper, therefore, changes of driving condition for car-following due to different road condition were dealt with, and optimal safety distance corresponding to road condition such as dry, wet and snowy were computed. The GMIT(GM Model with Instantaneous T) model was picked over for simulation of adaptive cruise control applied the suggested optimal safety distance. As the results, the 1.7 times longer safety distance was required for wet road condition than dry road condition, and the 5.6 times longer safety distance was required for snowy road condition.