A Study on the Parameter Identification of a Brushless DC Motor (브러시리스 직류전동기의 파라미터 동정에 관한 연구)

  • 임영철;조경영;정영국;김영민;장영학
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.2
    • /
    • pp.41-50
    • /
    • 1993
  • This paper describes an effort to develop a microcomputer-based parameter identification system for three phase and two phase brushless DC motor. Back EMF equation is derived from back EMF waveform of three phase and two phase brushless DC motor. In this paper, a new identification algorithm for the brushless DC motor parameters by Pasek's technique is developed. It is found that Pasek's equation is valid for the brushless DC motor, too. The results obtained clearly shows that it is possible to implement the identification system for the determination of the brushless DC motor parameters. To minimize errors due to the ripple component in the measured armature current, digital averaging firis employed. The whole identification process of signal generation, measuring, parameter determination is fully automated. The use of the propod method in the parameter identifition system shows that the averaged current curve is in excellent agreement with the estimated current curve. Therefore, this close agreement confirms the validity of this technique.

  • PDF

A Study on the Application of Simple Sprinkler Facility at Single Housing (단독주택의 간이스프링클러설비 적용에 관한 연구)

  • Hong, Sung-Woo;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.33-41
    • /
    • 2008
  • Presently, there is no legal regulation pertaining to the installation, maintenance, management and operation of fire-fighting facilities in single housing in Korea, relying instead on the awareness of the residents which hopefully will prevent fire. Likewise, accident prevention effort is very limiting and weak. Accordingly, this research examines current situation in which fire results, identifies root causes and studies application of regulations and develop design measures centered on the single housing that is most afflicted with fire. As part of the measure to prevent fire that afflict housing, it is necessary to classify single housing as specific target for fire fighting just like the joint housing among the types of the building structures that are classified according to the usage on the "Appendix Chart I of the Enforcement Ordinance of the Construction Law" for management purpose. Moreover, it is necessary to make the installation of fire-fighting facilities such as simple sprinkler facility for residential area, fire extinguisher, warning system and others for the sake of the senior citizens and disabled people who reside in single housing, mandatory.

Assessment of Magnetic Field Mitigation and Electrical Environmental Effects for Commercially Operating 154kV Transmission Lines with Passive Loop

  • Lee, Byeong-Yoon;Myung, Sung-Ho;Ju, Mun-No;Cho, Yeun-Gyu;Lee, Dong-Il;Lim, Yun-Seog;Kim, Sang-Beom
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.991-996
    • /
    • 2014
  • Power frequency magnetic field is still a critical problem for new construction of overhead power transmission lines in Korea because most people have been concerned about possibly carcinogenic effects of it. Although reference level of power frequency(60Hz) magnetic field has been set to 200uT in ICNIRP guidelines published in 2010, Korean government has no intention of adjusting 83.3uT specified by law in 2006 to this new reference level in consideration of people's concerns for the time being. Regardless of the current regulated magnetic field value, electric utility company has been trying to reduce magnetic field in the residential area in the vicinity of overhead power transmission lines to take into account of public concerns on the long-term effect of magnetic fields. In an effort to reduce magnetic field, engineering side has made considerable efforts to develop passive loop based, cost-effective mitigation technique of power frequency magnetic field more than ten years. In order to verify developed power frequency magnetic field mitigation technique based on passive loop, a horizontal type of passive loop was designed and installed for commercially operating 154kV overhead power transmission line for the first time in Korea. The measurement results before and after the installation of passive loop showed that magnetic field could be reduced to about 20%. The electrical environmental effects such as AN, RI and TVI were assessed before and after the installation of passive loop and these values were complied with the requirements specified by electric utility. It has been confirmed from the field test results that passive loop could be commercially and cost-effectively utilized to mitigate power frequency magnetic field.

TET2DICOM-GUI: Graphical User Interface Based TET2DICOM Program to Convert Tetrahedral-Mesh-Phantom to DICOM-RT Dataset

  • Se Hyung Lee;Bo-Wi Cheon;Chul Hee Min;Haegin Han;Chan Hyeong Kim;Min Cheol Han;Seonghoon Kim
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.172-179
    • /
    • 2022
  • Recently, tetrahedral phantoms have been newly adopted as international standard mesh-type reference computational phantoms (MRCPs) by the International Commission on Radiological Protection, and a program has been developed to convert them to computational tomography images and DICOM-RT structure files for application of radiotherapy. Through this program, the use of the tetrahedral standard phantom has become available in clinical practice, but utilization has been difficult due to various library dependencies requiring a lot of time and effort for installation. To overcome this limitation, in this study a newly developed TET2DICOM-GUI, a TET2DICOM program based on a graphical user interface (GUI), was programmed using only the MATLAB language so that it can be used without additional library installation and configuration. The program runs in the same order as TET2DICOM and has been optimized to run on a personal computer in a GUI environment. A tetrahedron-based male international standard human phantom, MRCP-AM, was used to evaluate TET2DICOM-GUI. Conversion into a DICOM-RT dataset applicable in clinical practice in about one hour with a personal computer as a basis was confirmed. Also, the generated DICOM-RT dataset was confirmed to be effectively implemented in the radiotherapy planning system. The program developed in this study is expected to replace actual patient data in future studies.

Design to Control Vibration for Stay Cable with Damper (댐퍼도입에 의한 사장 케이블의 제진설계)

  • Kim, Hyeon Kyeom;Hwang, Jae Woong;Lee, Myeong Jae;Seo, Ju Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.1A
    • /
    • pp.51-58
    • /
    • 2008
  • A cable element happens to vibration easily rather than other elements because a cable element has few rotational stiffness. Dynamic motion of stay cable is distinguished from vibration by wind and/or rain and excitation by support movement. Mostly a stay cable is vibrated by wind and/or rain except that when natural periods coincide between stiffening girder and stay cable. It happens to deterioration of serviceability and durability by vortex shedding, rainy-wind induced vibration, and galloping. Additional damping generated by installation of cable damper is well known good scheme against above phenomena. Researchers have lack of effort to develop the recommendations even if cable stayed bridges are designed and constructed in Korea. Therefore, development of the domestic recommendations should be achieved as soon as possible. This study suggests the consistent and systematic recommendations on vibration controlling design of stay cable by installation of damper. It gives readers two important methodologies that one evaluates required damping ratio, the other determines installing point considering efficiency.

A Proposition on Elevator Safety System using Expert's Decision (전문가의 의사결정을 이용한 안전한 엘리베이터 시스템 제안)

  • Park, Ju-Bong;Shin, Seung-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.4
    • /
    • pp.121-125
    • /
    • 2014
  • Recently, many of people concentrates on the importance of elevator safety system for the elevator accident of traction machine malfunction. Also, IT convergence has enlarged various field for the effort of enhanced traditional industry. In this paper, we define that the safety is to minimize the dangerous factor, then explain the rules of elevator installation. Through the expert's decision we could find out the dangerous factors are poor check, malfunction of amalgamative and user's mistake. We propose the IT convergence managing system for the effective alternative method of elevator safety system.

An Empirical Study on the Factors to Affect a BIS Use and Its Vitalization Plan : Busan Metropolitan City (버스정보안내기 이용요인 및 활성화 방안에 관한 실증연구 : 부산광역시를 중심으로)

  • Kim, Soon Ja;Hong, Soon Goo;Cha, Yoon Sook;Kim, Jong Weon
    • Journal of Information Technology Services
    • /
    • v.12 no.1
    • /
    • pp.1-14
    • /
    • 2013
  • The government has implemented operating the bus information terminal (hereinafter, 'BIT') to use by building it at a major bus station to solve the problem of traffic congestion. Busan Metropolitan City has been continuously expanding the installation of 'BIT' since 2003. However, there are few research on the factor to use and satisfaction survey on 'BIT' from the perspective of the users. This study, in an effort to inquire into the 'BIT' utilization factor and its vitalization plan, conducted a face to face survey of 172 citizens who had the experience in the 'BIT'. The result of the data analysis showed that usability, convenience, and availability were the critical factors for a BIT use. In addition, the general intention to use 'BIT' was found to be very high as much as 90.7%. The contributions of this study are as follows. The academic contributions is that it proved the relationship between usability, convenience and the intention to use suggested by the information technology acceptance model is supported even in case of 'BIT.' For the practitioners this study provides ground data for a local government to make a plan of a BIT extension.

Biogas-Microturbine Distributed Generation Developement at Gong-Ju Public Livestock Wastewater Treatment Facility (공주 축산폐수공공처리장에서의 바이오가스-마이크로터빈 분산발전시스템 개발)

  • Park, Jung-Keuk;Hur, Kwang-Beom;Lee, Ki-Chul;Kang, Ho;Rhim, Sang-Gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.229-234
    • /
    • 2008
  • Korea Electric Power Corporation (KEPCO) has started the nation's first biogas-microturbine project in the city of Gongju as an effort to encourage the utilization of wasted biogas containing useful energy source in the form of $CH_4$. The goal of the project is to set up the biogas microturbine co-generation system for utilizing biogas as an energy source and improving the economics of the wastewater treatment plant. Wastewater treatment processes were investigated in depth to find improvement possibility. Changes in internal recirculation ratio and pre-treatment degree are needed to optimize plant operation and biogas production. Biogas pre-treatment system satisfies Capstone's fuel condition requirement with the test result of 99.9% and 90.2% of hydrogen sulphide and ammonia is removal performance. Installation of microturbine and manufacture of heat exchanger to warm anaerobic digester has been done successfully. Expected economic profit produced by the system is coming from energy saving including electricity 115,871kWh/year and heat contained in exhaust gas 579GJ/year.

  • PDF

Improvement of effluent water quality by sludge aeration at the conventional drinking water treatment plant (정수장 슬러지 폭기를 통한 방류수 수질 개선)

  • Choi, Ilgyung;Shin, Changsoo;Beak, Inho;Lim, Jaecheol;Jeong, Chanwoo;Lee, Sungjin;Park, Jungwook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.2
    • /
    • pp.249-255
    • /
    • 2014
  • So many drinking water treatment plants are under various difficulties by new reinforced effluent standards. Since the target turbidity, much higher than annual average, for designing sludge thickener have to be set to confront high turbidity season, the sludge at thickener should be put up for a long time during usual days. So the soluble manganese and chloroform may be formed under the anaerobic environment in the sludge thickener when the sludge retention time is longer with low turbidity. This phenomenon results in difficulties to keep regulatory level of the discharged effluent. For an effort to overcome the problems, a sludge aeration was successfully implemented into the thickening process. As a result, the final effluent quality and sludge volume were much improved; 41 % of manganese, 62 % of chloroform and 35 % of sludge volume. Additionally, effluent quality was improved ; 61 % of Manganese on aeration with pH control and we could make sure of stability effluent quality despite a long sludge retention time. We recommended the standard of installation sludge aeration equipment to nationally supply water treatment plant under effluent water quality problem ; Manganese, Chloroform, etc.

A SENSITIVITY STUDY OF THE DISTORTED INLET FLOW IN AXIAL TURBOMACHINERY WITH NOVEL INTEGRAL SCHEME

  • Ng Eddie Yin-Kwee;Liu Ningyu;Lim Hong Ngiap;Tan Daniel
    • Journal of computational fluids engineering
    • /
    • v.10 no.1
    • /
    • pp.51-55
    • /
    • 2005
  • For proper installation, operation and performance of axial flow jet engines in aircrafts, the impacts and effects of inlet flow distortion in axial compressors have to be understood. Inlet distortion conditions may cause component-mismatch and instability problems known as rotating stall, and severe oscillations of mass flow rate called surge or a combination of both. Typical effects of this phenomenon include stresses and wear on the compressor blading, destruction of entire jet engines due to the failure of airfoil and mechanical failure or interruption of the combustion process. Therefore, it is important to study inlet flow distortion and its propagation effects to minimize and hence to prevent the occurrence of such calamity. The current novel integral method with parametric analysis signifies its validity to this field of research and offers much potential for further improvements. The present effort further indicates that this simple method may be flourishing in the problems of strongly distorted flow and propagating stall in axial compressor. It is therefore believe that using a more realistic and flexible velocity and pressure profiles could develop this approach further.