• Title/Summary/Keyword: installation/management

Search Result 1,166, Processing Time 0.023 seconds

The Case Study of CCTV Priority Installation Using BigData Standard Analysis Model (빅데이터 표준분석모델을 활용한 CCTV우선 설치지역 도출 사례연구)

  • Sung, Chang Soo;Park, Joo Y.;Ka, Hoi Kwang
    • Journal of Digital Convergence
    • /
    • v.15 no.5
    • /
    • pp.61-69
    • /
    • 2017
  • This study aims to investigate the public big data standard analysis model developed by Ministry of the Interior and examine its accuracy and reliability of prediction. To do this, big data standard analysis index were calculated to apply them to the real world case of CCTV monitoring system prior installation in K city. The result of this case study revealed that the areas to be installed CCTV consisted with the area where residences requested and complained to install CCTV monitoring systems, which indicated that the result of big data standard analysis model provided accurate and reliable outcomes. The result of this study suggested implications on effective exploitation of big data analysis.

Installation and Shipboard Tests of the Ballast Water Treatment System Electro-Cleen (Electro-Cleen 선박평형수 처리장치의 실선 설치 및 선상시험)

  • Kim, Eun-Chan;Cho, Jin-Suk;Park, Yong-Seok;Lee, Jong-Wook
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.3
    • /
    • pp.209-216
    • /
    • 2009
  • IMO has established International Convention for the Control and Management of Ships' Ballast Water and Sediment 2004 in February 2004 in order to prevent transfer of aquatic organisms through ballast water. According to the Convention, Each countries are preparing ratification and legislation process and encouraging the development of treatment system to satisfy the performance standard in the Convention. This Electro-$Cleen^{TM}$ treatment system was granted IMO basic approval in March 2006, and final approval in October 2008. The Type Approval Certificate was issued in December 2008 by the Government of Republic of Korea. This paper considers the matter of principle mechanism, overview of the system, installation on shipboard and shipboard test results for the Electro-$Cleen^{TM}$. Shipboard tests with the 8300 GT M/V Yokohama and 27,000 DWT M/V Greenwing have already been conducted. These tests confirmed that the Electro-$Cleen^{TM}$ system satisfies all of the IMO standards and is suitable for installation in new and existing ships.

  • PDF

A Study on the Application of SVR at the Distribution Line Interconnected with Wind Turbine (풍력발전이 연계된 배전선로의 SVR 적용연구)

  • Chae, Woo-Kyu;Lee, Hak-Ju;Jung, Won-Wook;Kim, Ju-Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.109-118
    • /
    • 2010
  • It is expected that distribution system, interconnected with wind turbines, would experience the voltage problem due to WT's output. But most papers just consider this problem using the simulation or the theory only. In this paper, we verify this problem through the measurement at the distribution system and wind turbine. We explain the method for voltage management at distribution system. And we verify that the voltage of D/L interconnected with WTs could not be maintained properly using pole transformer's tap only. We consider some method to solve this problem and we propose the installation of SVR(step voltage regulator). Finally we show this method's validity through the simulation.

Economy Analysis to Retrofit Ballast Water Treatment System for an Existing Vessel (선박 평형수 처리장치 선정을 위한 경제성 분석)

  • JEE, Jae-Hoon;PARK, Sang-Kyun;OH, Cheol
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.5
    • /
    • pp.1319-1328
    • /
    • 2016
  • Since Ballast Water Management Convention has been effected, BWTS, applied to new-building vessels and existing vessels, have been developed from many countries with various treatment methods. However, BWTS is mainly typed Electrolysis, Ozone and UV type. Approximately 70 products have been type approved by the Flag Administrations. For the new-building vessels, the vessels' design and construction have been considered for arrangements and installations for BWTS. However, existing vessels which already construction had finished have problem with selection of BWTS type for installation and arrangement. The selection of the most economized BWTS system is important though, CAPEX has not been made any significant differences. However, OPEX is more important factor. Consequently, detail analysis of OPEX is the key to the selection of the most economized BWTS system and also it can be the purpose of this study. The feasibility study on the main three type of BWTS (Electrolysis, Ozone and UV type) for 175K Bulk Carrier and 57K Cargo ship has been conducted for this study. Because, these three type of BWTS have been the most frequently installed and used and the two type of object vessels are consist of the 40% of the world merchant ship market. For this study, interest rate, project duration (operation time after installation), maintenance cost and fuel oil price are considered as major factor of feasibility study. In addition, expecting Interest rates to sensitivity analysis conducted for more accurate feasibility study. For 175K Bulk carrier, ozone treatment system is more economical than other types. For 57K cargo ship, UV type is considered more economical than other types. However, it is concluded that electrolysis type is more suitable compare to installation space, total weight and electrical power consumption.

Analysis of the Effect of Dredging and Weirs on Bed Change in the Nakdong River and its Tributary using HEC-6 (HEC-6를 이용한 준설 및 보로 인한 낙동강 본류 및 지류 하상변화 분석)

  • Ahn, Jung Min;Kwak, Sunghyun;Lyu, Siwan
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.9
    • /
    • pp.743-756
    • /
    • 2015
  • It is necessary to evaluate the effect of dredging and weir operation on the flow and long-term bed change for river management. Especially, large scale river treatment project, with dredging or weir installation and operation, can increase the instability of riverbed in tributaries as well as mainstream. This study focuses on the effect of weir installation and dredging on the long-term bed change in Nakdong river (Gangjeong- Goryeong Weir~Dalseong Weir) and its tributary (Geumho river). HEC-6 model has been used to analyze the amount of long-term bed change and sediment transport resulted from the river treatment including dredging or weir installation. From the result, it was concluded that a large scale river treatment can accelerate and increase the long-term bed change both in mainstream and tributary.

An Experimental Study on the Dispersion Characteristics of Seawater Injection Nozzle for Hull Cooling (선체냉각을 위한 해수분사노즐의 산포특성에 관한 실험 연구)

  • Yoon, Seoktae;Jung, Hoseok;Cho, Yongjin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.767-773
    • /
    • 2017
  • Infrared stealth is an important technology for naval ships. This technology helps improve the anti-detection performance and survivability of naval ships. In general, the infrared signature of naval ships are categorized into internal and external heat source. External signature are generated by ship surface heating by solar flux as well as the complicated heat transfer process with the surrounding weather condition. Modern naval ships are equipped with seawater injection nozzles on the outside for nuclear, biological and, chemical, and these nozzles are used to control external signature. Wide nozzle placement intervals and insufficient injection pressure, however, have reduced seawater dispersion area. To address this problem, nozzle installation standards must be established. In this study, an actual-scale experimental system was implemented to provide the evidence for nozzle installation standards in order to reduce the infrared signature of naval ships. In addition, the environmental conditions of the experiment were set up through computational fluid dynamics considering the ocean climate data and naval ship management conditions of South Korea. The dispersion distance was measured using a high-resolution thermography system. The flow rate, pipe pressure, and dispersion distance were analyzed, and the evidence for the installation of seawater injection nozzles and operation performance standards was suggested.

Assessing Policy Priorities for Green Seaport Construction - The Case of Busan and Incheon Port - (그린항만 구축을 위한 정책우선순위 평가 -부산항과, 인천항을 중심으로-)

  • CHUNG, Tae-won;LEE, Yong-joo
    • The Journal of shipping and logistics
    • /
    • v.34 no.4
    • /
    • pp.657-675
    • /
    • 2018
  • This study examines various policy programs for the creation of green harbors in major ports in the Northwest of the United States and suggests ways to apply them to major ports in Korea. Based on the fuzzy analysis process, the importance of major policy programs for the development of green ports in Korea was compared and analyzed. As a result of importance analysis, the Green Ship Incentive Program and the Carbon Footprint Program were identified as the most important policies. The first policy programs that should be introduced to Incheon Port are the AMP installation operation program and a vessel slowing program around the seaport. In case of Busan Port, the AMP installation operation program, the vessel slowing program around the seaport, carbon footprint, and installation of DPF were found to be excellent policies. These results may provide practical implications for policy makers of port authorities which has conducted environmental projects.

Study on the effective response method to reduce fire risk of wood fuel heating system (화목 연료 난방설비의 화재 위험 감소 방안에 관한 이론적 연구)

  • Park, Kyong-Jin;Lee, Bong-Woo;Lee, Guen-Cull;Nam, Ki-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.2
    • /
    • pp.163-171
    • /
    • 2019
  • Recently, rural housing in urban areas has been increasing due to the improvement of income level. With the increase of the construction of the power house, the installation of the heating system using the harmonious fuel for the purpose of heating and the beauty of the room is increasing rapidly. In addition to the increasing use of firewood heating equipment, the incidence of fire is also increasing. Analysis of the National Fire Data System of the Fire Department The result of the analysis of the National Fire Data System Many parts of the fire are incinerated by the accumulation of tar due to the incompleteness of periodic cleaning inside the cylinder. The distance between the fire extinguisher and the combustible materials such as ceiling, Resulting in fire. In addition, it was found that much of the fire of the firewood heating system in the time zone occurs during the sleeping and resting time and there is not enough time for the residents to cope. This, in turn, causes serious harm to the lives and property of the users of the pyrotechnic heating system. Therefore, in this study, domestic and foreign standards and laws related to fuel oil heating facilities were analyzed and 12 cases of fire accidents were analyzed. Through the revision of the fire prevention and firefighting facilities installation and maintenance law, the installation standards of the alarm and fire extinguishing facilities were presented.

Analysis of Allowable Settlement on Tracks of High Speed Railway (고속철도 궤도 종류에 따른 허용침하량 분석)

  • Kim, Young-Ho;Jeong, Sang-Seom;Seol, Hoon-Il;Han, Young-Ah
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.11
    • /
    • pp.25-34
    • /
    • 2008
  • An application of concrete track is being actively processed for the construction of Korean high speed railway. The concrete track has an advantage in decreasing the maintenance cost, whereas it has much difficulty controlling the long term settlement after settlement occurred. Therefore, the management and control of settlement are very important for the successful construction of concrete track. The purpose of this paper is to verify the allowable settlement between concrete track and ballast track, and piled raft foundation installation effects as settlement reducers for concrete track. Therefore, a series of 3D finite element analyses that take into account the allowable settlement were performed for major parameters such as soil condition, pile installation and loading type. Based on the analysis, it is shown that concrete track causes much smaller settlement than ballast track, and the effect of installation is necessary to effectively reduce the settlement of concrete track.

Aircraft Fuel Efficiency Improvement and Effect through APMS (APMS 활용을 통한 항공기 연비향상 및 기대효과 )

  • Jae Leame Yoo
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.31 no.2
    • /
    • pp.81-88
    • /
    • 2023
  • SHM (Structural Health Monitoring) technique for monitoring aircraft structural health and damage, EHM (Engine Health Monitoring) for monitoring aircraft engine performance, and APM (Application Performance Management) is used for each function. APMS (Airplane Performance Monitoring System) is a program that comprehensively applies these techniques to identify the difference between the performance manual provided by the manufacturer and the actual fuel mileage of the aircraft and reflect it in the flight plan. The main purpose of using APMS is to understand the performance of each aircraft, to plan and execute flights in an optimal way, and consequently to reduce fuel consumption. First, it is to check the fuel efficiency trend of each aircraft, check the correlation between the maintenance work performed and the fuel mileage, find the cause of the fuel mileage increase/decrease, and take appropriate measures in response. Second, it is to find the cause of fuel mileage degradation in detail by checking the trends by engine performance and fuselage drag effect. Third, the APMS is to be used in making maintenance work decisions. Through APMS, aircraft with below average fuel mileage are identified, the cause of fuel mileage degradation is identified, and appropriate corrective actions are determined. Fourth, APMS data is used to analyze the economic analysis of equipment installation investment. The cost can be easily calculated as the equipment installation cost, but the benefit is fuel efficiency improvement, and the only way to check this is the manufacturer's theory. Therefore, verifying the effect after installation and verifying the economic analysis is to secure the appropriateness of the investment. Through this, proper investment in fuel efficiency improvement equipment will be made, and fuel efficiency will be improved.