• Title/Summary/Keyword: installation/management

Search Result 1,166, Processing Time 0.031 seconds

Database PasS web service system using Docker

  • Hur, Tai-Sung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.11
    • /
    • pp.51-58
    • /
    • 2020
  • Most of the students in computer-related departments work on projects, and it is essential to use a database for project execution. To use such a database, it is necessary to install a Database Management System. However, it takes several minutes (hours) to install a DBMS, and some DBMS require a difficult installation process. Therefore, in order to solve this problem, this study proposed a system that can easily install DBMS using Docker. Docker is an open source project that automates the deployment of Linux applications into software containers. Docker Container is wrapped in a complete file system that includes everything necessary for the execution of software, and includes code, runtime, system tools, system libraries, and anything that is installed on the server. This guarantees that they will always run the same regardless of the environment in which they are running. After creating a database using this proposed system, you can check the database access information on the web and check the server status in minutes. As a result of of implementing this proposed system and applying it to the projects of 10 teams, the installation time was reduced by 94.5% for Maria DBMS and 98.3% for Oracle DBMS than individual installation, confirming improved efficiency.

Analysis of Water Cycle Effect by Plan of LID-decentralized Rainwater Management Using SWMM-LID Model in a Low-carbon Green Village (SWMM-LID를 이용한 저탄소 녹색마을의 LID-분산형 빗물관리 계획에 따른 물순환 효과 분석)

  • Lee, Jung-Min;Hyun, Kyoung-Hak;Lee, Yun-Sang;Kim, Jung-Gon;Park, Yong-Boo;Choi, Jong-Soo
    • Land and Housing Review
    • /
    • v.2 no.4
    • /
    • pp.503-507
    • /
    • 2011
  • There was a plan to develop a low-carbon green village(approximately $400,000m^2$) in A city, a new town. Restoration of water cycle is essential for creation of the low-carbon green village. Therefore, installation plan of LID-decentralized rainwater management facilities for natural water cycle was established for creation of the low-carbon green village. Analyses on effect of the water cycle were performed in conditions of before, after developing the low-carbon green village and after installing the LID facilities(rain garden, constructed wetland, rainwater harvesting facility, etc.) using SWMM-LID model developed by EPA. Due to the characteristic of permeable area before development and significant green spaces after development, installation plan of LID facilities to restore the water cycle did not show an obvious effect. However, potential of the hydrological cycle could be seen by the installation of the LID facilities.

Suggestion for Safety Improvement of Compressed Natural Gas Vehicle (압축천연가스 자동차의 안전성 향상을 위한 제언)

  • Kim, Young-Seob;Park, Kyo-Shik;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.4
    • /
    • pp.1-7
    • /
    • 2012
  • Systematic safety research by Korea Government has been made to enhance the safety of CNG (compressed natural gas) vehicles since the burst of compressed cylinder of an urban bus in August 9, 2010. This article summarizes some major activities to ensure the safety of CNG vehicles, which covers review of regulation, safety management system including standard of inspection and certification, and training program of inspectors and car mechanics. Specifically, the followings were reviewed; type of CNG cylinder, location of CNG cylinder, material and type of fuel line and vent line, modification of pipeline connection, installation of gas detector, installation of emergency shutdown valve, installation of protecting cover for cylinder, obligations for CNG vehicle filling station. improving periodical inspection, routine test on gas vehicles, training program for engaged in gas vehicles, and designation of safety manager for CNG bus company. This paper suggests how to improve safety of CNG vehicles as a result of review of above mentioned check items.

A Review on Potential Effects of Installation and Operation of Ground Source Heat Pumps on Soil and Groundwater Environment (지열히트펌프시스템의 설치 및 운영이 토양.지하수에 미치는 영향에 대한 고찰)

  • Jo, Yun-Ju;Lee, Jin-Yong;Lim, Soo-Young;Hong, Gyeong-Pyo
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.3
    • /
    • pp.22-31
    • /
    • 2009
  • Recently use of renewable energies such as geothermal energy for space heating and cooling is increasing in Korea due to energy crisis and global warming. Ground source heat pump (GSHP) is known as one of the most environment-friendly HVAC (heating, ventilation and air-conditioning) systems in the world. However, some potential effects caused installation and operation of the GSHP systems on soil and groundwater environment are reported. The potential effects are closely related with inappropriate installation, operation and closure of the GSHP systems. In this paper, possible effects of the GSHPs on soil and groundwater environments are reviewed.

Analysis of Installation Status and Application of GIS for Preliminary Risk Assessment of Underground Storage Tanks in Chuncheon City (춘천시의 지하 저장 탱크의 예비적 위해성 평가를 위한 설치 현황 분석 및 지리정보시스템의 적용)

  • Kim, Joon-Hyun;Han, Young-Han;Lee, Jong-Chun;Kwon, Young-Sung;Lee, Kwang-Yeon
    • Journal of Industrial Technology
    • /
    • v.22 no.A
    • /
    • pp.127-135
    • /
    • 2002
  • In this study, the preliminary risk assessment for the underground storage tanks(UST) in Chunchon city was implemented using the geographical information system(GIS). The estimation variables, such as the installation year, storage capacity, the distances from streams, and from groundwater pumping wells, were selected to estimate the relative risk levels. The weighting factors were given to all the estimation variables. Cumulative scores were induced by the combination of all the scores of the corresponding variables using the buffering technique and the overlay analysis in ArcView. Using the these process, the relative risk level of each UST was estimated. Some sites in this study are simplified and reduced because the number of useable data are limited or too enormous. Thus the selection of the comprehensive estimation variables and the proper weighting values are required for the future study. The methodology in this study could be served not only for the preliminary risk assessment of UST but also for the selection of the proper location of new and old UST. And, it can be used for the effective management system of UST.

  • PDF

A Research on the Actual Conditions of the Electric Shock Hazard of a Guard Lamp (보안등의 감전 위험성에 관한 실태조사)

  • Jang, Tae-Jun;Jung, Yeon-Ha;Roh, Young-Su;Kwak, Hee-Ro;Choi, Chung-Seog
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.4
    • /
    • pp.32-38
    • /
    • 2005
  • In this paper, guard lamps at three areas have been investigated to understand the actual conditions of the electric shock hazard of the guard lamps. Upon the basis of the obtained data, the actual conditions of the guard lamps were precisely analyzed in terms of the electric shock hazard. As a result of the investigation, it was turned out that many guard lamps were not installed in organized ways due to the lack of legal regulations, resulting in the increase of electric shock hazard. Therefore, it is necessary, from a point of electric shock protection view, to establish the regulations of equipment installation and management, which can be specifically applied to guard lamps.

Evaluating locational validity of anti-crime CCTV installation point in university campus : A KNU case study (대학 캠퍼스 방범용 CCTV 설치 지점의 적절성 평가 : 경북대학교를 사례로)

  • Choi, Jin-Ho;Kim, Jun-Hyun;Ryu, Taek-Hyoung
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2010.06a
    • /
    • pp.175-179
    • /
    • 2010
  • This study was to evaluate of installation location and management problem for a closed circuit television according to the present situation and installation environment when the CCTV doesn't take a location, surrounding environment, mechanical function in the campus. This methodology used network analysis, mechanical characterization and Streetlight illuminance. As a result, we confirmed in Kyung-Buk National University that was problem of unrelated location of walk pattern in students, a short of illuminance location, only 25 CCTV can be used to crime prevention of student in the night but, the other one is need to some improvement under 44 CCTV.

  • PDF

Feasibility Study on Installation of Individual Room Control Ventilation in Apartment House (공동주택의 실별 제어환기 도입 타당성 분석)

  • Kim, Jung-Yup;Shin, Hyun-Joon;Kwon, Yong-Il;Yun, Young-Woo;Cho, Chun-Sik
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.502-507
    • /
    • 2009
  • Trend of mechanical ventilation system applied to apartment house is introduced and feasibility study on installation of the individual room control ventilation as energy-saving method is carried out through field experiment. While initial cost of installation for the individual room control ventilation increases, the running cost is lower than the individual household control ventilation due to automatic flow rate control and reduction of fan power, and the management cost also decreases due to extension of use life of components. As the results of field experiment on $115m^2$-type apartment house, the individual room control ventilation could save the amount of 1,459.5Wh/day when compared with the individual room control ventilation

  • PDF

Study of the MSW landfill Facility of Installation and Consideration (폐기물 매립시설 설치방법 및 고려사항에 대한 고찰)

  • Kim, Sang-Keun;Kwon, Ki-Bum;Yu, Jun;Chung, Ha-Ik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.259-266
    • /
    • 2008
  • In the past, MSW (Municipal Solid Waste) disposal was typically done by recycling, incineration, or landfilling. In South Korea prior to the late 1950's, land burial was usually accomplished by disposal in an open dump. Currently, with increasing concerns and environmental recognition, MSW disposal and landfilling is more restricted. MSW landfill facilities have been developed with certain design and construction specifications. However, these methods have a space for improvement. MSW landfill facilities follow a step wise approach of design, construction, operation and closure management after use in agreement with established environmental and sanitary standards. This study intends to give a technical guidance for installation and consideration of newly established MSW landfill facilities, and also provide an establishment and regular inspection of MSW landfill facilities.

  • PDF

A Development and Performance Test of Voltage Measurement Accuracy Assessment System for Distribution Equipment (배전기기 전압계측 정밀도 평가시스템 개발 및 성능시험)

  • Cho, Jin-Tae;Kim, Ju-Yong;Lee, Hak-Ju;Kim, Jae-Han
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.83-89
    • /
    • 2013
  • Power distribution system has been changed from radial system to closed loop or mesh system due to connection of distributed generation growth. Data from distribution equipments which are installed at distribution line is required to be accurate for the performance of DMS(Distribution Management System). This paper analyzes the voltage measurement data from distribution equipment. However, the results of the analysis are confirmed to have some errors in voltage measurement data from distribution equipment. These errors come from aging of voltage sensor in distribution equipment and inaccurate data transfer to FRTU(feeder remote terminal unit) through the controller. The main problem is that the voltage measurement data of distribution equipment can not be assessed after it's first installation at the distribution line. The voltage measurement accuracy assessment system is to assess the voltage measurement data from distribution equipment on hot-line. This study had a field test to verify the performance of system.