• Title/Summary/Keyword: inner system

Search Result 2,156, Processing Time 0.032 seconds

Experimental investigation of the Rotating Cryogenic System (회전하는 극저온 시스템의 단열 특성에 관한 실험적 연구)

  • 이창규;정상권
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.63-66
    • /
    • 2000
  • A rotating cryogenic system was designed similar to the cooling system for the rotor of a superconducting generator. The experimental rotor has an inner vessel which simulates the winding space of an actual superconducting rotor, and a torque tube of comparable design. This paper describes the evaluation of the total heat leak into the inner vessel that leads to the study of the jheat transfer characteristic of the rotating cryogenic system.

  • PDF

ITERATING A SYSTEM OF SET-VALUED VARIATIONAL INCLUSION PROBLEMS IN SEMI-INNER PRODUCT SPACES

  • Shafi, Sumeera
    • The Pure and Applied Mathematics
    • /
    • v.29 no.4
    • /
    • pp.255-275
    • /
    • 2022
  • In this paper, we introduce a new system of set-valued variational inclusion problems in semi-inner product spaces. We use resolvent operator technique to propose an iterative algorithm for computing the approximate solution of the system of set-valued variational inclusion problems. The results presented in this paper generalize, improve and unify many previously known results in the literature.

A Study on the Locational Characteristics and Road System of Existing Old Settlements in Cheongju City (청주 원도심 내 현존하는 옛마을의 입지특성과 가로체계의 변화)

  • Kwon, Mi-Sun;Kim, Tai-Young
    • Journal of the Korean housing association
    • /
    • v.21 no.5
    • /
    • pp.137-144
    • /
    • 2010
  • The purpose of this study is to clarify locational characteristics and the road systems of existing 22 old settlements in Cheongju downtown of Korea. These old settlements are classified largely into two types by geographical feature; Hill type located in ridge and Valley type in the valley from the ridge. The Hill type is further categorized into San-rock located on ridge and Gogae located on hillside, and the Valley type into closed large and small valley, that is, Daegok and Sogok by the shape and size of the valley. The road systems are classified into outer road, approaching road, inner road, and side road. In San-rock type villages, Inner road is changed side roads by new arterial road, and new ones become inner road. The outer road are almost cut off, but side roads maintain. In the case of the Gogae type, main road becomes inner road, maintain old hierarchical road, and in other cases, villages are formed around side roads derived from main road, and outer road and inner road are cut off. Among the Valley type, Daegok type maintains old hierarchical road, while for Sogok type, outer roads are cut off, and new roads are outer road.

Performance Characteristics of Refrigerant R170(Ethane) Refrigeration System Using Liquid-gas Heat Exchanger (액-가스 열교환기를 이용한 R170(에탄)용 냉동시스템의 성능 특성)

  • Ku, Hak-Keun
    • Journal of Power System Engineering
    • /
    • v.20 no.5
    • /
    • pp.78-85
    • /
    • 2016
  • This paper considers the influence of internal heat exchangers to the efficiency of a refrigerating system using R170. These liquid-gas heat exchangers(internal or suction-line heat exchangers) can, in some cases, yield improved system performance while in other cases they degrade system performance. A steady state mathematical model is used to analysis the performance characteristics of refrigeration system with internal heat exchanger. The influence of operating conditions, such as the mass flowrate of R170, inner diameter tube and length of internal heat exchanger, to optimal dimensions of the heat exchanger is also analyzed in the paper. The main results were summarized as follows : the mass flowrate of R170, inner diameter tube and length of internal heat exchanger, and effectiveness have an effect on the cooling capacity, compressor work and RCI(Relative Capacity Index) of this system. Exception for the effect of inner diameter, the RCI of R170 with respect to refrigerant mass flowrate, the length and effectiveness of internal heat exchanger is about 2.1~3.3% higher than that of R13 at the same experimental conditions. With a thorough grasp of these effect, it is necessary to design the R170 compression refrigeration cycle using internal heat exchanger.

Design of Noninvasive Arterial Blood Pressure Measurement System by Using Double-Cuffs Oscillometric Method (이중 커프 오실로메트릭법을 이용한 비침습 동맥압 측정시스템의 설계)

  • Lee, Pil-Jae;Lee, Young-Jae;Kim, Dong-Jun;Lee, Jae-Ho;Lim, Min-Gyu;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.885-890
    • /
    • 2012
  • In this study, a new blood pressure measuring system was proposed and implemented. An additional small-cuff was placed on the center of a inner cuff to measure morphological signals and new oscillometric ratio. The proposed BP-measuring system is composed of an external cuff, an inner cuff and a small-cuff. Oscillation signal from small-cuff is interpolated with 7th-order fitting polynomials and SBP, DBP ratio were 22.2% and 87.7%. Experimental data were gathered from 20 volunteers ($25{\pm}4$ years) and arterial blood pressure values were compared with auscultation, sphygmomanometers, small-cuff and inner-cuff. As a result, the difference in systolic BP between auscultation and the small-cuff was 1.93(${\pm}1.28$) mmHg, and the inner-cuff was 4.53(${\pm}4.39$) mmHg, and sphygmomanometer was 6.68(${\pm}3.99$) mmHg, and the corresponding difference in diastolic BP was 2.50(${\pm}2.04$) mmHg, 3.50(${\pm}3.19$) mmHg, 7.35(${\pm}5.62$), respectively.

Improving cyclic behavior of multi-level pipe damper using infill or slit diaphragm inside inner pipe

  • Zahrai, Seyed Mehdi;Cheraghi, Abdullah
    • Structural Engineering and Mechanics
    • /
    • v.64 no.2
    • /
    • pp.195-204
    • /
    • 2017
  • Analytical and experimental studies of the innovative pipe in pipe damper have been recently investigated by the authors. In this paper, by adding lead or zinc infill or slit diaphragm inside the inner pipe, it is tried to increase the equivalent viscous damping ratio improving the cyclic performance of the recently proposed multi-level control system. The damper consists of three main parts including the outer pipe, inner pipe and added complementary damping part. At first plastic deformations of the external pipe, then the internal pipe and particularly the added core and friction between them make the excellent multi-level damper act as an improved energy dissipation system. Several kinds of added lead or zinc infill and also different shapes of slit diaphragms are modeled inside the inner pipe and their effectiveness on hysteresis curves are investigated with nonlinear static analyses using finite element method by ABAQUS software. Results show that adding lead infill has no major effect on the damper stiffness while zinc infill and slit diaphragm increase damper stiffness sharply up to more than 10 times depending on the plate thickness and pipe diameter. Besides, metal infill increases the viscous damping ratio of dual damper ranging 6-9%. In addition, obtained hysteresis curves show that the multi-level control system as expected can reliably dissipate energy in different imposed energy levels.

Thermal System Analysis to Optimize Torch Position in The Core Making Machine. (중자조형기의 토치위치 최적화를 위한 열계해석)

  • Han, Geun-Jo;Ahn, Sung-Chan;Shim, Jae-Joon;Han, Dong-Seop
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.1
    • /
    • pp.43-47
    • /
    • 2002
  • The new core making method economizing the amount of core sand has been requested. The new method is that a core box is heated until it reaches reasonable temperature and then core sand with core binder is sprayed into the core box. Since inner temperature distribution have to be uniform in order to form uniform thickness of core, we studied inner temperature distribution of core box. First, we determined proper number of torches and optimized torch positions to minimize the average of absolute deviation(AVEDEV) of inner temperature. The results are as fellowed: 1. The number of torches that enables uniform inner temperature distribution about $300^{\circ}C$ is 25. 2. When $S_H$ and $S_V$ is 0.7, the torch positions are optimized and AVEDEV is 5.85.

A Study on the Integrated Control and Safety Management System for 9% Ni Steel LNG Storage Tank (9% 니켈강재식 LNG 저장탱크용 통합제어안전관리시스템에 관한 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.5
    • /
    • pp.13-18
    • /
    • 2010
  • This paper presents the development of an integrated control and safety management system for 9% nickel steel LNG storage tank. The new system added the measuring equipment of pressure, displacement and force compared to the conventional measurement and control system. The measured data has simultaneously been processed by integrating and analyzing with new control equipments and safety management systems. The integrated control and safety management system, which may increase a safety and efficiency of a super-large full containment LNG storage tank, added additional pressure gauges and new displacement/force sensors at the outer side wall and a welding zone of a stiffener and top girder of an inner tank, and the inner side wall of a corner protection tank. The displacement and force sensors may provide failure clues of 9% nickel steel structures such as an inner tank and a corner protection, and a LNG leakage from the inner tank. The conventional leak sensor may not provide proper information on 9% nickel steel tank fracture even though LNG is leaked until the leak detector, which is placed at the insulation area between an inner tank and a corner protection tank, sends a warning signal. Thus, the new integrated control and safety management system is to collect and analyze the temperature, pressure, displacement, force, and LNG density, which are related to the tank system safety and leakage control from the inner tank. The digital data are also measured from control systems such as displacement and force of 9% nickel steel tank safety, LNG level and density, cool-down process, leakage, and pressure controls.

Automatic Measuring System Developement of Slab Inner Crack and Center Segregation (슬라브 내부 크랙 및 중심편석 자동 판정 시스템 개발)

  • Kim, Sung-Yong;Lee, Su-Hyun;Ahn, In-Seok
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.332-334
    • /
    • 2009
  • This thesis puts forward a suggestion of measuring inner crack and center segregation in steel processing by using scanner and image processing with sulfur printer. This is a system to scan according to the program, to choose the size of the specimen and to press the 'Measurement' button, come to a check result, to send the result to the server, and to save the data and check the measurement result in web. To sum up, there are three points in this system.

  • PDF

On the Leakage Analysis of a Full Containment Tank Using a FEM

  • Kim, Chung-Kyun
    • KSTLE International Journal
    • /
    • v.7 no.2
    • /
    • pp.45-50
    • /
    • 2006
  • In this paper, the leakage safety of prestressed concrete structure including the insulation panels has been analyzed using a finite element analysis just after a collapse of 9% nickel inner tank. This FEM study shows that the outer tank may contain the leaked cryogenic liquid for the time being until the primary pump in the inner tank transports stored cryogenic liquids to the nearest LNG storage tank before the outer tank is demolished. This means that the total tank thickness from the insulation panel to the outer tank system safely may retain the leaked cryogenic fluids. The FE computed results indicate that the current structure in a full containment tank is obviously enough to securing the leak-proof safety of the tank system with two primary pumps.