• Title/Summary/Keyword: inlet surface

Search Result 508, Processing Time 0.027 seconds

The Distribution of Substance P and Calcitonin Gene-Related Peptides Immunoreactive Fibers in the Rat′s Larynx (흰쥐 후두에 분포된 신경에서 Substance P 및 Calcitonin Gene-Related Peptides의 발현양상)

  • 박정수;정광윤;최종욱
    • Korean Journal of Bronchoesophagology
    • /
    • v.2 no.1
    • /
    • pp.97-102
    • /
    • 1996
  • The larynx has three major functions such as protective reflex, respiration and phonation, and is richly innervated by sensory, sympathetic and parasympathetic nerves. The sensory innervation of the laryngeal mucosa, which is involved in the perception of pain, mechanical and chemical irritation, prtects the airway via various laryngeal reflexes. We studied the distribution of Substance P (SP) and Calcitonin Gene-Related Peptide (CGRP) sensory fibers in the rat's larynx using the immuno-histochemical methods. Many SP and CGRP immunoreactive fibers were found in all regions of the laryngeal mucosa except the vocal cords. SP immunoreactive fibers showed a very similar distribution to the CGRP fibers in the epithelium and submucosa. But SP immunoreactive fibers were sparser than CGRP immunoreactive fibers in distribution density. Both reactive fibers were denser in the supraglottic region than subglottic region. Especially, intraepithelial fibers displayed the densest innervation to the laryngeal surface of the epiglottis. h the subepithelium, SP and CGRP immunoreactive fibers were distributed along the wall of vessels and around the glands. The present results suggest that the regional distribution of SP and CGRP immunoreactivity may be responsible for the protective reflex function of the laryngeal inlet.

  • PDF

Evaluating Effective Volume and Hydrodynamic Behavior in a Full-Scale Ozone Contactor with CFD Simulation (전산유체역학을 이용한 실규모 오존 접촉에서의 수리거동과 유효 체적 평가에 관한 연구)

  • Park, No-Suk;Mizuno, Tadao;Tsuno, Hiroshi;Bea, Chul-Ho;Lee, Seon-Ju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.656-665
    • /
    • 2004
  • An Ozone reaction model combined with CFD(Computational Fluid Dynamics) technique was developed in this research, in the simulation of ozonation, hydrodynamic behavior as well as reaction model is important because ozone is supplied to treated water as gas ozone. In order to evaluate hydrodynamic behavior in an ozone contactor, CFD technique was applied. CFD technique elucidated hydrodynamic behavior in the selected ozone contactor, which consisted of three main chambers. Three back-mixing zones were found in the contactor. The higher velocities of water were observed in the second and third compartments than that in the first compartment. The flow of the opposite direction to the main flow was observed near the water surface. Based on the results of CFD simulation, the ozone contactor was divided into small compartments. Mass balance equations were established were established in each compartment with reaction terms. This reaction model was intended to predict dissolved ozone concentration, especially. We concluded that the model could predict favorably the mass balance of ozone, namely absorption efficiency of gaseous ozone, dissolved ozone concentration and ozone consumption. After establishing the model, we discussed the effect of concentration of gaseous ozone at inlet, temperature and organic compounds on dissolved ozone concentration.

The Effects of Staggered Rows of Rectangular Shaped Holes on Film Cooling (엇갈린 배열의 사각홀이 막냉각에 미치는 영향)

  • Kim, Young-Bong;Rhee, Dong-Ho;Lee, Youn-Seok;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.3
    • /
    • pp.304-314
    • /
    • 2004
  • An experimental study has been conducted to measure the temperature fields and the local film cooling effectiveness for two and three staggered rows of the rectangular shaped-holes with various blowing rates. The hydraulic diameter of rectangular-shaped hole is 10mm. To compare with the film cooling performance of rectangular-shaped hole, two kinds of circular holes are tested. One has the same hydraulic diameter as the rectangular hole and the other has the same cross sectional area. Also, rectangular holes with expanded exit with same inlet area as rectangular ones are tested. Temperature fields are measured using a thermocouple rake attached on three-axis traversing system. Adiabatic film cooling effectiveness on the surface are obtained based on experimental results of thermochromic liquid crystals. The film cooling effectiveness is measured for various blowing rates and compared with the results for the cylindrical holes. In case of 2 rows, the rectangular holes has better performance than circular holes due to its slot-like geometry. In case of 3 rows, the effecta of hole shape is not clear.

A Behavior of the Diffuser Rotating Stall in a Low Specific Speed Mixed-Flow Pump

  • Miyabe, Masahiro;Furukawa, Akinori;Maeda, Hideaki;Umeki, Isamu;Jittani, Yoshinori
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.1
    • /
    • pp.31-39
    • /
    • 2009
  • The flow instability in a low specific speed mixed-flow pump, having a positive slope of head-flow characteristics was investigated. Based on the static pressure measurements, it was found that a rotating stall in the vaned diffuser occurs at about 65% flow rate of best efficiency point (BEP). A dynamic Particle Image Velocimetry (DPIV) measurement and the numerical simulations were conducted in order to investigate the flow fields. As a result, the diffuser rotating stall was simulated even by Computational Fluid Dynamics (CFD) and the calculated periodic flow patterns agree well with the measured ones by DPIV. It is clarified that a periodical large scaled backflow, generated at the leading edge of the suction surface of the diffuser vane, causes the instability. Furthermore, the growth of the strong vortex at the leading edge of the diffuser vane induces the strong backflow from the diffuser outlet to the inlet. The scale of one stall cell is covered over four-passages in total thirteen vane-passages.

Computer Simulation of Coating Behavior Including Air for Various Coater Geometries and Operational Conditions (코팅 공정에서 공기를 고려한 코터형상 및 운전조건에 따른 코팅현상 해석)

  • Kim, H.Y.;Lyu, M.Y.;Choi, J.G.
    • Transactions of Materials Processing
    • /
    • v.18 no.2
    • /
    • pp.156-159
    • /
    • 2009
  • Slot coating has been wide spread in photo-resist coating on the glass for liquid crystal display. Die in slot coater consists of manifold and land. Material comes in inlet of the die and flow into the manifold and then flow out through the land. The coating thickness variations along the die length depend upon inside of die design such as manifold and die land. However the coating thickness variations along the moving direction(coating direction) of the coater depend upon the operational conditions of coater as well as die lip design. The coating behaviors including atmospheric air have been investigated in this study. Die geometries considered in this study were nozzle gap and length of the die lip. Coating gap and coating speed were the variables fur coating operational conditions. When the nozzle gap and length of die lip increased climbing effect of PR on the downstream die lip was reduced. Subsequently uniformity of coating thickness improved. Uniformity of coating thickness also enhanced as coating gap and coater speed increased. The uniformity of coating gap was related to the velocity vector distributions on the coating surface.

Analysis of Fluid-Structure Interaction for Development of Korean Inflatable Rubber Dams for Small Hydropower (소수력 발전용 한국형 공기주입식 고무댐 개발을 위한 유체-구조 연성 해석)

  • Hwang, Tae-Gyu;Kim, Jin-Gu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1221-1230
    • /
    • 2008
  • Inflatable rubber dams are used for controlling flood, impounding water for recreations, preventing beach erosions, diverting water for irrigations, and generating hydropower. They are long, flexible, inflated with air, cylindrical structures on a rigid horizontal foundation such as concrete. The dam is modeled as an elastic shell inflated with air. The mechanical behaviors of the inflated dam model were investigated by using the finite element method. The analysis process such as One Way Coupling Fluid-Structure Interaction consists of two steps. First, the influences of the fluid side were investigated, viz, the shape changes of the inflated rubber dam due to the fluid motions was captured when the height of the dam was 30cm with air pressure 0.01MPa, at which the pressure distributions over the surface of the dam were calculated. And next, the structural deformations were calculated using the pressure distributions. The initial inlet velocity for flow field was set to 0.1m/s. The structural deformation behaviors were investigated. The final research goal is to develop a Korean Inflatable Rubber Dam to be used for generating small hydropower.

Simultaneous Removal of H2S, NH3 and Toluene in a Biofilter Packed with Zeocarbon Carrier

  • Park, Byoung-Gi;Shin, Won-Sik;Jeong, Yong-Shik;Chung, Jong-Shik
    • Journal of Environmental Science International
    • /
    • v.17 no.1
    • /
    • pp.7-17
    • /
    • 2008
  • Simultaneous removal of $NH_3,\;H_2S$ and toluene in a contaminated air stream was investigated over 185 days in a biofilter packed with Zeocarbon granule as microbial support. In this study, multi-microorganisms including Nitrosomonas and Nitrobacter for nitrogen removal, Thiobacillus thioparus (ATCC 23645) for $H_2S$ removal, and Pseudomonas aeruginosa (ATCC 15692), Pseudomonas putida (ATCC 17484) and Pseudomonas putida (ATCC 23973) for toluene removal were used simultaneously. The empty bed residence time (EBRT) was 40-120 seconds and the feed (inlet) concentrations of $NH_3,\;H_2S$ and toluene were 0.02-0.11, 0.05-0.23 and 0.15-0.21 ppmv, respectively. The observed removal efficiency was 85%-99% for $NH_3$, 100% for $H_2S$, and 20-90% for toluene, respectively. The maximum elimination capacities were 9.3, 20.6 and $17g/m^3/hr\;for\;NH_3,\;H_2S$ and toluene, respectively. The results of kinetic model analysis showed that there were no particular evidences of interactions or inhibitions among the microorganisms, and that the three bio degradation reactions took place independently within a finite area of biofilm developed on the surface of the Zeocarbon carrier.

Study on Calorimeteric Chamber for Heat Flux Measurement in Liquid Rocket Engine (액체로켓 추력실에서 heat flux측정을 위한 calorimeteric chamber의 연구)

  • Kim, Byeong Hun;Park, Hui Ho;Hwang, Su Gwon;Kim, Yu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.4
    • /
    • pp.76-81
    • /
    • 2003
  • To investigate the convective heat transfer phenomena inside the Lox/Kerosene liquid rocket combustion chamber, hot fire tests were performed by using a water-cooled calorimetric chamber. The calorimetric chamber consists of one cylindrical section and nozzle section with independent cooling passage. To measure the heat flux, thermocouples were installed inlet and outlet of cooling passage of each section. The investigated range of combustion chamber pressure is from 100 psi to 300psi at fixed O/F ratio of 2.0 and radiation heat transfer from the hot gas to the surface is not considered. The measured heat flux was almost linearly depended on the chamber pressure.

Paint Spray Mass Spectrometry for the Detection of Additives from Polymers on Conducting Surfaces

  • Paine, Martin R.L.;Barker, Philip J.;Blanksby, Stephen J.
    • Mass Spectrometry Letters
    • /
    • v.3 no.1
    • /
    • pp.25-28
    • /
    • 2012
  • Paint Spray is developed as a direct sampling ionisation method for mass spectrometric analysis of additives in polymer-based surface coatings. The technique simply involves applying an external high voltage (5 kV) to the wetted sample placed in front of the mass spectrometer inlet and represents a much simpler ionisation technique compared to those currently available. The capabilities of Paint Spray are demonstrated herein with the detection of four commercially available hindered amine light stabilisers; TINUVIN${(R)}$770, TINUVIN${(R)}$292, TINUVIN${(R)}$123 and TINUVIN${(R)}$152 directly from thermoset polyester-based coil coatings. Paint Spray requires no sample preparation or pre-treatment and combined with its simplicity requiring no specialised equipment makes it ideal for use by non-specialists. The application of Paint Spray for industrial use has significant potential as sample collection from a coil coating production line and Paint Spray ionisation could enable fast quality control screening at high sensitivity.

Experimental Study on the Optimal Heat Exchanger of Thermoelectric Generation System for Industrial and Automobile Waste Heat Recovery (차량 및 산업설비 폐열회수용 열전발전시스템의 최적 열교환 시스템에 관한 실험적 연구)

  • Chung, Jae-Hoon;Kim, Woo-Chul;Lee, Jin-Ho;Yu, Tae-U.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.460-463
    • /
    • 2008
  • A large part of the overall industrial energy is dissipated as waste heat despite of much development in the utilization of thermal energy. A mean efficiency is reported to be only around 30 to 35%. The existing waste heat recovery technology has reached its limit and consequently, the development of a new technology is necessary. Improving efficiency using thermoelectric technology has recently come into the spotlight because of its unique way to recover thermal energy. In fact, thermoelectric generator directly converts thermal energy into electric energy by a solid state without any moving parts. Futhermore remarkable improvement in the thermoelectric energy conversion efficiency has been achieved. In this study, a thermoelectric generator was made using commercialized thermoelectric modules. With thermoelectric modules attached on a duct surface, hot air was blown into the duct using a hot air blower. On the other side of the module, a water jacket was attached to cool the module. With different air inlet temperatures and water flowrates, the electrical power of the thermoelectric generator was measured.

  • PDF