• Title/Summary/Keyword: initial line current

Search Result 83, Processing Time 0.032 seconds

Measurements of Load Current of XLPE Cables Installed at the Load Terminal of Turbine Generator in Operation at Thermoelectric Power Station (화력 발전소의 터빈 발전기 부하단에 설치된 XLPE 케이블의 부하전류 측정)

  • Um, Kee-Hong;Kim, Bo-Kyeong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.1
    • /
    • pp.207-212
    • /
    • 2017
  • The cables installed to deliver high electric power from a generator at a thermoelectric power station are XLPE (or CV) cables. Depending on the installation and usage conditions, the cables in operation start deteriorating from the time of initial operation. Some cables can cause accidents due to faulty construction or other environmental factors. In order to prevent cable accidents, regular auditing of power cables is required. We have invented a measuring device for systematic surveillance and prevention of accidents, and installed the device at Korean Western Power Co. Ltd. which measures load currents through the cables. In this paper, we present the load current measured using our device, analyze the load characteristics by measures current, compare the ampacity defined by IEC standard, and present a basic data to obtain the temperature of cable conductors.

A Study on the Use of Communication Functions in Mobile Messenger Emoticons - Focus on Line Messenger - (모바일 메신저에서 이모티콘 캐릭터를 통한 플랫폼 비즈니스 확장에 관한 연구 - 카카오 프렌즈와 라인 프렌즈를 중심으로 -)

  • Kim, Ho
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.4
    • /
    • pp.151-158
    • /
    • 2020
  • SNS on the mobile platform is an essential element and tool for communication and has become a part of life for many people. Having been accustomed to non-face-to-face communication, people today have chosen to use emoticons instead of text to express their feelings and the use of emoticons is constantly growing. This is because the emoticons in various styles of drawings and movements can evoke emotional and sentimental reactions in users and express their tastes in addition to feelings. The current study was conducted to analyze the use of initial emoticon characters released by two most leading SNS platforms in Korea--Kakao for Kakao Talk and Naver for Line--and their expansion to various platform businesses. Based on the cases of the two companies, it discussed the development and goals of Korea-made emoticons in the future as cultural contents.

Relationship between Sea Surface Temperature derived from NOAA Satellites and Cochlodinium polykrikoides Red Tide occurrence in Korean Coastal Waters (NOAA 위성자료에 의한 해수표면 수온분포와 Cochlodinium polykrikoides 적조 발생의 상관성)

  • Suh, Young-Sang;Kim, Jeong-Hee;Kim, Hak-Gyoon
    • Journal of Environmental Science International
    • /
    • v.9 no.3
    • /
    • pp.215-221
    • /
    • 2000
  • The relationship between the distribution of sea surface temperature(SST) and dinoflagellate(Cochlodinium polykrikoides) bloom areas were studied. The SST data were derived from the infrared channels of AVHRR(Advanced Very High Resolution Radiometer) sensor on NOAA(National Oceanic and Atmospheric Administration) 12 and 14 satellites during 1995-1998. The initial water temperature at C. polykrikoides bloom was about 21${\circ}C$ at the coastal areas of the South Sea and along the shore of the East Sea of Korea during the summer season of 1995. The northern limit of red tides was coincident with that of 21${\circ}C$ isothermal line in the East Sea. The red tides that initially bloomed at the coast of Pohang on September 21, 1995 moved to the coast of Uljin on September 26, 1995. The skipped appearance of the red tides in the areas between Pohang and Uljin was due to the East Korean Warm Current, which was moving offshore from Pohang to approach to Uljin. The cold water which was formed by tidal front in the western coast of the South Sea and by upwelling water from deep layer in the southeastern coast of the Korean peninsula played a role in blocking the spreading of red tides during summer season in 1997 and 1998. In conclusion, the distribution of red tides appeared to be dependent on the initial water temperature at red tides bloom. The SST at the red tides varied from 21${\circ}C$ to 25${\circ}C$; 21${\circ}C$, 23${\circ}C$, 24 and 24-25${\circ}C$ in 1995, 1996, 1997 and 1998, respectively.

  • PDF

50-300 keV X-ray Transmission Ratios for Lead, Steel and Concrete

  • Tae Hwan Kim;Kum Bae Kim;Geun Beom Kim;Dong Wook Kim;Sang Rok Kim;Sang Hyoun Choi
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.164-171
    • /
    • 2022
  • The number of facilities using radiation generators increases and related regulations are strengthened, the establishment of a shielding management and evaluation technology has become important. The characteristics of the radiation generator used in previous report differ from those of currently available high-frequency radiation generators. This study aimed to manufacture lead, iron, and concrete shielding materials for the re-verification of half-value layers, tenth-value layers, and attenuation curve. For a comparison of attenuation ratio, iron, lead, and concrete shields were manufactured in this study. The initial dose was measured without shielding materials, and doses measured under different types and thicknesses of shielding material were compared with the initial dose to calculate the transmission rate on 50-300 kVp X-ray. All the three shielding materials showed a tendency to require greater shielding thickness for higher energy. The attenuation graph showed an exponential shape as the thickness decreased and a straight line as the thickness increased. The difference between the measurement results and the previous study, except in extrapolated parts, may be due to the differences in the radiation generation characteristics between the generators used in the two studies. The attenuated graph measured in this study better reflects the characteristics of current radiation generators, which would be more effective for shield designing.

Life Analysis and Reliability Prediction of Micro Switches based on Life Prediction Method (수명예측 방법에 따른 마이크로스위치의 수명분석 및 신뢰도 예측)

  • Ji, Jeoung-Geon;Shin, Kun-Young;Lee, Duk-Gyu;Son, Young-Jin;Lee, Hi-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.14-21
    • /
    • 2011
  • Reliability means that a product maintains its initial quality and performance at certain period of time(time, distance, cycle etc) under given condition without failure. Given conditions include both environmental condition and operating condition. Environmental condition means common natural environment such as temperature, humidity, vibration, and working condition means artificial environment such as voltage, current load, install place, hours of use, which occurs during using the product. In the field of railway vehicles, although components of railway vehicles with reliability are the trend of mandatory as persisting period of railway vehicles is extended, using components of railway vehicles is insufficient for the practical reliability assessment. but the meaning of the first railway operating agnecy to acquire the parts in the field, the data suggest the reliability of products if you can and can show the reliability of modular units and modular units can provide the reliability of if you can present reliability of the entire system is thought to be here. In this study, lifespan of micro-switch for master controller is analyzed and prediction is performed based on its field data considering the special circumstances of railway vehicles operating agency, such as a large number of trains operates on the same line.

  • PDF

Prediction of Influence of Polluted Water Discharged from Saemankeum Lake (새만금 간척지구 담수호 건설에 따른 담수배출의 영향범위 예측)

  • Kim, Dae-Geun;Seo, Il-Won;Baek, Gyeong-O
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.6
    • /
    • pp.649-659
    • /
    • 1997
  • The influence of polluted water discharged from the Saemankeum Lake is predicted by using two-dimensional finite element model. The simulation results show that influence of the Polluted water to the northern part of the Kckunsan Islands is small during flood time. The reason is because lock gates are located in the south of the Kokunsan Islands so that tidal current directing north is blocked by these Islands. However, during the ebb time, the influence of the polluted water is extended to the whole southern part of the Kokunsan Islands. When the amount of ten percent of the total volume of polluted water is discharged from the Saemankeum Lake, equi-concentration contour line of one tenth of initial discharge concentration includes the inner area surrounded by Sinsi Island, Munyeo Island, Bian Island, and Daehang-Li. In general, peak concentration near the lock gates is found out to be higher during the spring tide than the neap tide.

  • PDF

Current Status of an International Co-Operative Research Program, PARTRIDGE (Probabilistic Analysis as a Regulatory Tool for Risk-Informed Decision GuidancE) (국제공동연구 PARTRIDGE를 통한 확률론적 건전성 평가 기술 개발 현황)

  • Kim, Sun Hye;Park, Jung Soon;Kim, Jin Su;Lee, Jin Ho;Yun, Eun Sub;Yang, Jun Seog;Lee, Jae Gon;Park, Hong Sun;Oh, Young Jin;Kang, Sun Yeh;Yoon, Ki Seok;Park, Jai Hak
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.9 no.1
    • /
    • pp.62-69
    • /
    • 2013
  • A probabilistic assessment code, PRO-LOCA ver. 3.7 which was developed in an international co-operative research program, PARTRIDGE was evaluated by conducting sensitivity analysis. The effect of some variables such as simulation methods (adaptive sampling, iteration numbers, weld residual stress model), crack features(Poisson's arrival rate, maximum numbers of cracks, initial flaw size, fabrication flaws), operating and loading conditions(temperature, primary bending stress, earthquake strength and frequency), and inspection model(inspection intervals, detectable leak rate) on the failure probabilities of a surge line nozzle was investigated. The results of sensitivity analysis shows the remaining problems of the PRO-LOCA code such as the instability of adaptive sampling and unexpected trend of failure probabilities at an early stage.

Life Analysis and Reliability Prediction of Micro-Switches based on Life Prediction Method (수명예측 방법에 따른 마이크로스위치의 수명분석 및 신뢰도 예측)

  • Ji, Jung-Geon;Shin, Kun-Young;Lee, Duk-Gyu;Lee, Hi Sung
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.7 no.1
    • /
    • pp.57-69
    • /
    • 2011
  • Reliability means that a product maintains its initial quality and performance at certain period of time(time, distance, cycle etc) under given condition without failure. Given conditions include both environmental condition and operating condition. Environmental condition means common natural environment such as temperature, humidity, vibration, and working condition means artificial environment such as voltage, current load, install place, hours of use, which occurs during using the product. In the field of railway vehicles, although components of railway vehicles with reliability are the trend of mandatory as persisting period of railway vehicles is extended, using components of railway vehicles is insufficient for the practical reliability assessment. but the meaning of the first railway operating agency to acquire the parts in the field, the data suggest the reliability of products if you can and can show the reliability of modular units and modular units can provide the reliability of if you can present reliability of the entire system is thought to be here In this study, lifespan of micro-switch for master controller is analyzed and prediction is performed based on its field data considering the special circumstances of railway vehicles operating agency, such as a large number of trains operates on the same line.

Development of Water Quality Modeling in the United States

  • Ambrose, Robert B;Wool, Tim A;Barnwell, Thomas O.
    • Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.200-210
    • /
    • 2009
  • The modern era of water quality modeling in the United States began in the 1960s. Pushed by advances in computer technology as well as environmental sciences, water quality modeling evolved through five broad periods: (1) initial model development with mainframe computers (1960s - mid 1970s), (2) model refinement and generalization with minicomputers (mid 1970s - mid 1980s), (3) model standardization and support with microcomputers (mid 1980s - mid 1990s), (4) better model access and performance with faster desktop computers running Windows and local area networks linked to the Internet (mid 1990s - early 2000s), and (5) model integration and widespread use of the Internet (early 2000s - present). Improved computer technology continues to drive improvements in water quality models, including more detailed environmental analysis (spatially and temporally), better user interfaces and GIS software, more accessibility to environmental data from on-line repositories, and more robust modeling frameworks linking hydrodynamics, water quality, watershed and atmospheric models. Driven by regulatory needs and advancing technology, water quality modeling will continue to improve to better address more complicated water bodies and pollutant types, and more complicated management questions. This manuscript describes historical trends in water quality model development in the United States, reviews current efforts, and projects promising future directions.

40nm InGaAs HEMT's with 65% Strained Channel Fabricated with Damage-Free $SiO_2/SiN_x$ Side-wall Gate Process

  • Kim, Dae-Hyun;Kim, Suk-Jin;Kim, Young-Ho;Kim, Sung-Wong;Seo, Kwang-Seok
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.3 no.1
    • /
    • pp.27-32
    • /
    • 2003
  • Highly reproducible side-wall process for the fabrication of the fine gate length as small as 40nm was developed. This process was utilized to fabricate 40nm InGaAs HEMTs with the 65% strained channel. With the usage of the dual $SiO_2$ and $SiN_x$ dielectric layers and the proper selection of the etching gas, the final gate length (Lg) was insensitive to the process conditions such as the dielectric over-etching time. From the microwave measurement up to 40GHz, extrapolated fT and fmax as high as 371 and 345 GHz were obtained, respectively. We believe that the developed side-wall process would be directly applicable to finer gate fabrication, if the initial line length is lessened below the l00nm range.