• 제목/요약/키워드: infusion

검색결과 1,316건 처리시간 0.025초

의료용 Infusion Pump 개발에 관한 연구 (A Study on the Microcomputer Based Infusion Pump)

  • 이경중;이윤선
    • 대한의용생체공학회:의공학회지
    • /
    • 제5권1호
    • /
    • pp.63-68
    • /
    • 1984
  • The Infusion pump that is widely used in hospital has been designed. This system consists of microcomputer system, stepping motor control part and mechanical part for syringe driving. It has 450mmHg maximum pressure and $\pm$0.5% accuracy, and and especially keep the accent on the electrical and functional safety.

  • PDF

Effects of VFAs and Glucose Infusions on Ruminating Behavior of the Fasted-Goats

  • Oshiro, S.;Kawamura, T.;Hirayama, T.;Hirakawa, M.;Higoshi, H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제11권2호
    • /
    • pp.171-175
    • /
    • 1998
  • To test their roles in rumination behavior, metabolites (acetic acid, propionic acid, butyric acid and glucose) were intravenously infused into the jugular vein of goats during fasting. The heads of four female goats tested were locked in a stanchion of cages in an experimental room. Ruminating behaviors with regard to number of ruminations, ruminating time, number of remastications and remasticating time were significantly decreased by acetic acid infusion (p < 0.05), and tended to be depressed more on values in butyric acid infusion or glucose infusion than those in pre-infusions, but propionic acid infusion decreased a little. Those data suggest that rumination receptors sensitive to VFAs and glucose are more likely to be situated in the area, where they would respond too blood levels.

단독 경막외 통증자가조절법과 지속주입을 병용한 경막외 통증자가조절법의 비교 (Comparison of Patient Controlled Epidural Analgesia Alone and Patient Controlled Epidural Analgesia with Continuous Infusion)

  • 김동희;이태수
    • The Korean Journal of Pain
    • /
    • 제9권2호
    • /
    • pp.368-373
    • /
    • 1996
  • Background: The purpose of this study was to determine whether there is any advantage for a continuous background infusion during patient controlled epidural analgesia(PCEA) for postoperative pain control. Methods: 60 patients scheduled for elective cesarean section under epidural anesthesia were assigned randomly in a double-blind fashion to receive fentanyl and bupivacaine by PCEA with or without background infusion for 48 hours postoperatively. Results: Total amount of fentanyl and bupivacaine consumption and degree of sedation were not significantly different between the two groups. Visual analogue scale(VAS) pain scores at 24, 36, and 48h and sleep disturbance were significantly lower in background infusion group. Conclusion: Administration of fentanyl with bupivacaine by continuous background infusion is appropriate for PCEA for postcesarean section pain control.

  • PDF

정보기술구현 내부확산단계에서 지식창조과정에 관한 질적 연구 (A Qualitative Study on the Process of Knowledge Creation at the Infusion Stage in IT Implementation)

  • 백상용;박경수
    • 한국정보시스템학회지:정보시스템연구
    • /
    • 제15권2호
    • /
    • pp.125-152
    • /
    • 2006
  • The purpose of this study is to explore the process of knowledge creation at the infusion stage in IT adoption. Because of the lack of the prior research on the infusion and the process of individual knowledge creation we employed Grounded Theory Method which is a qualitative method for building a theory inductively. Collecting and analyzing data from 13 knowledge workers including medical doctors, project managers, and bankers, a process model is developed through the serial process of open, axial and selective coding. We conceptualized the knlowledge creation at the infusion stage as a social process where knowledge is expressed through private and public justifications. This study also found that organizational politics, top management supports, and organization strategy are important factors facilitating the knowledge creation process.

  • PDF

인퓨전 펌프 모니터링 시스템 개발에 관한 연구 (Monitoring System of The Infusion Pump)

  • 박준범;구본재;이우주;이상빈
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2016년도 춘계학술발표대회
    • /
    • pp.129-132
    • /
    • 2016
  • The importance of the infusion pump monitoring system has become amplified in accordance with the growth of IoT(Internet of Things) technology and medical devices. A monitoring system can be described as an essential part of infusion pump system because the patient must be observed all the time. Infusion pump monitoring system is significant to have better safety and efficiency. In this paper, we propose an efficient algorithm and scheme in the infusion monitoring system. In particular, the proposed algorithm based on the time of the database interlocking part was found to have a 30% higher efficiency than the conventional method.

링거액 주입시의 부피팽창 효과에 대한 모델링 (Modeling of Volume Expansion Effects During Infusion of Ringer's Solution)

  • 이은호;최규택;여영구
    • 제어로봇시스템학회논문지
    • /
    • 제12권12호
    • /
    • pp.1191-1196
    • /
    • 2006
  • In this work the kinetics of volume changes of fluid spaces associated with infusion of Ringer's solution are analyzed using the body fluid space model. During infusion of Ringer's solution, the human body is assumed to be characterized by the fluid space model into which fluid is fed and from which fluid is left. Various infusion types were tested to accommodate different medical situations. Volunteers were given Ringer's solution and the changes in blood hemoglobin were detected. From the comparison with experimental data, the single- and two-fluid space models were found to represent adequately the kinetics of human volume expansion during infusion of Ringer's solution.

피에조마이크로펌프를 이용한 클라우드기반 수액주입기 (A Cloud-based Infusion Injector using Piezoelectric Micropump)

  • 송영진;강정구;송근산
    • 반도체디스플레이기술학회지
    • /
    • 제17권4호
    • /
    • pp.62-65
    • /
    • 2018
  • We will provides a micro-pump infusion injector with the cloud networking for remote control. The existing infusion injector with controlled manually have an uncomfortable to use it inconveniently. The proposed remote control infusion, infusion system enables the identification and control of injected amount through the IOT function on th WEB. The micro-pump used is a piezo electric pump manufactured by using MEMS technology, and the amount of charge is varied depending on the frequency magnitude through the micro-controller. The micro-pump can adjust the speed of the fluid depending on the frequency and can be from 0.1ml / min to 7ml / min when the frequency is from 3 to 110Hz.

제왕절개술후 통증치료로 지속적 정주방법과 고식적 근주방법의 비교 (A Comparison of Continuous Intravenous Infusion and Traditional Intramuscular Injection for Postoperative Pain following Cesarean Section)

  • 조영례
    • The Korean Journal of Pain
    • /
    • 제9권2호
    • /
    • pp.374-379
    • /
    • 1996
  • Background: Recently, improvements in drug administration technology have intensified interest in the treatment of postoperative pain. this has resulted in increased use of continuous intravenous infusion of opioid and epidural opioid as alternative to traditional intramuscular administration of opioid. The goal of this study, therefore, was to document the effects of pain control and side effects following continuous intravenous infusion of morphine or meperidine and intramuscular meperidine following cesarean section. Methods: The vital signs, pain score, oxygen saturation and side effects were compared in 150 patients receiving continuous intravenous infusion of morphine, 30 ${\mu}g/kg/hr$ (n=50, group 1); continuous intravenous infusion of meperidine, 150 ${\mu}g/kg/hr$ (n=50, group 2); or intramuscular meperidine, 50mg/every 6hrs (n=50, group 3). Results: VAS (Visual Analogue Scale) was significantly decreased after 30 minutes of administration in all three groups and was significantly lower at 1 hour, but higher at 6 hours in group 3 than two other groups. Severe desaturation episode, defined as $SpO_2$<90%, occurred in the group 3(0.2%). Moderate desaturation episodes, defined as $SpO_2$ 91~95%, occurred more in group 3 than in group 1 and 2 (17.4% vs. 10.4%, 8.2%). The incidence of side effects were similar among three groups. Conclusion: The continuous infusion of opioid was more effective and safe method of postoperative pain control than traditional intramuscular injection.

  • PDF

Comparison of Single-Dose Toxicity by Intravenous Infusion or Bolus Injection with CKD-602, a Camptothecin Anticancer Agent in Rats (II): Hematological and Serum Biochemical, and Histopathological Changes

  • Kim, Choong-Yong;Yang, Byung-Chul;Kim, Joon-Kyum;Kim, Jong-Choon;Kim, Yong-Beom;Kang, Boo-Hyon;Han, Sang-Seop
    • Toxicological Research
    • /
    • 제20권4호
    • /
    • pp.381-389
    • /
    • 2004
  • The toxicity of CKD-602 was investigated at doses of 3, 9, and 27 mg/kg in rats, when the same total dose of CKD-602 was administered over 24 hr-continuous infusion or bolus injection. At 3 and 9 mg/kg, the 24-hr infusion group showed a more decreased WBC count on day 3, compared with the bolus group. Administration of CKD-602 caused more toxic effects such as the significant decreases of RBC counts, hematocrit, hemoglobin, and platelet count on day 7 post-administarion in the 24-hr infusion group than in the bolus group. Administration of CKD-602 also caused histopathological changes such as extramedullary hemopoiesis of liver and spleen, hyperplasia of femoral bone marrow, and caecal dilation. These toxic effects were more severe in the 24-hr infusion group than in the bolus injection group, indicating that the toxicity of CKD-602 may be dependant upon the duration of administration.

Compatibility of Diazepam with Polypropylene Multilayer Infusion Container

  • Noh, Dong-Il;Park, Kyu-Nam;Chun, Heung-Jae;Park, Chong-Won;Jang, Ju-Woong;Ahn, Yun-Gyong
    • Macromolecular Research
    • /
    • 제17권7호
    • /
    • pp.516-521
    • /
    • 2009
  • Techflex$^{(R)}$, a polypropylene-lined, multilayer infusion bag, was studied for its compatibility with diazepam, in comparison to the conventional infusion bag, Safeflex$^{(R)}$, which is comprised of poly(vinyl chloride) (PVC). Diazepam was diluted in 0.9% sodium chloride isotonic solution and stored in the infusion bags for 24 h. To evaluate the sorption of diazepam into the infusion bags during storage, the concentration of the drug remaining in the bag was measured using gas chromatography-mass spectroscopy. The PVC bags exhibited a marked sorption of diazepam, with a drug loss reaching up to 90% of the initial concentration after 24 h of contact, whereas Techflex$^{(R)}$ inhibited the drug sorption, showing approximately 10%, under the same conditions. The differences in the sorption behaviors of the bags are discussed in terms of solubility parameters and crystallinities of the polymers.