• 제목/요약/키워드: infrared radiation

검색결과 487건 처리시간 0.024초

중위도 기상조건에서 함정의 연돌 방사율을 고려한 적외선 복사량 예측 및 감소방안 연구 (A Study on Prediction of Surface Temperature and Reduction of Infrared Emission from a Naval Ship by Considering Emissivity of Funnel in the Mid-Latitude Meterological Conditions)

  • 길태준;최준혁;조용진;김태국
    • 대한조선학회논문집
    • /
    • 제44권1호
    • /
    • pp.40-47
    • /
    • 2007
  • This study is focused on developing a software that predicts the temperature distribution and infrared Emission from 30 objects considering the solar radiation through the atmosphere. The solar radiation through the atmosphere is modeled by using the well-known LOWTRAN7 code. Surface temperature information is essential for generating the infrared scene of the object. Predictions of the transient surface temperature and the infrared emission from a naval ship by using the software developed here show fairly good results by representing the typical temperature and emitted radiance distributions expected for the naval ship considered in mid latitude. Emissivity of each material is appeared to be an important parameter for recognizing the target in Infrared band region. The numerical results also show that the low emissivity surface on the heat source can be helpful in reducing the IR image contrast as compared to the background sea.

적외선 복사에너지에 의한 시료의 물리적 손상 측정 (Measurement of Physical Demage of Samples by Infrared Radiation)

  • 정동선;김기훈;한종성;김훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.131-135
    • /
    • 2004
  • The molecules of the substance absorbing a light obtains the radiant energy to the wavelength of the light to make thermal reactions or photochemical reactions. Specially, thermal reactions by infrared radiation brings about physical damage by temperature rise process or temperature drop process of the material. In this study, a measuring system was set up to measure the temperature rise and temperature drop of each sample by infrared radiation from light source. And a physical demage of samples by infrared radiation were measured using the measuring system.

  • PDF

적외선 탐지소자의 내방사선화 연구 (A Study on Radiation Hardening of a Infrared Detector)

  • 이남호;김승호;김영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권11호
    • /
    • pp.490-492
    • /
    • 2005
  • A study on radiation hardening of infrared(IR) detector, the chief component of IR camera was performed. The radiation test on IR sensor passivated with the ZnS by Co$^{60}$ gamma-ray over 1 Mrads showed the reduction in Ro by 1/100 which was related to the noise level. This effect that was caused by carrier trapping in the ZnS passivation layer increased the leakage current and resulted in degradation in the device performance. For the radiation hardening of IR devices we suggested the ones with CdTe passivation layer which had a tendency to reluctant to carrier trapping in its layer and developed test patterns. Radiation test to the patterns showed that the our CdTe passivated device could survived over 1 Mrad gamma-ray dose.

알루미늄에 코팅된 SiO$_2$/Fe$_2$O$_3$막의 적외선 복사특성에 관한 연구 (A Study on the Infrared Radiation Properties for SiO$_2$/Fe$_2$O$_3$Films Coated on aluminum)

  • 강병철;김기호
    • 한국표면공학회지
    • /
    • 제36권5호
    • /
    • pp.406-412
    • /
    • 2003
  • FT-IR and thermography were used to investigate the infrared radiation characteristic of SiO$_2$ film and SiO$_2$/Fe$_2$O$_3$film coated on aluminum. Through FT-TR spectrum, SiO$_2$film showed high infrared absorption in accordance with the stretching vibration of Si-O-Si, and as$ Fe_2$$O_3$was mixed additional absorption band appeared resulting from the stretching vibration of Fe-O at $590cm^{-1}$ and the bond of Si-O-Fe at $900 cm^{-1}$ The two kinds of film measured by the integration method and the reflective method coincided with each other in the wavelength area of infrared absorption and radiation, and corresponded well with Kirchhoff's law as the infrared emissivity is high in wavelength where infrared absorption rate is high. The emissivity of $SiO_2$ film was 0.65 and that of $SiO_2$/Fe$_2$$O_3$film was 0.77, so the addition of$ Fe_2$$O_3$ raised the infrared emissivity by approximately 13%.$ SiO_2$$Fe_2$$O_3$ film is efficient as an infrared radiator at below $100^{\circ}C$. The temperature of heat radiation after 7 minutes was 117$^{\circ}C$ in aluminum plate and $155^{\circ}C$ in $SiO_2$$Fe_2$$O_3$ film, $38^{\circ}C$ higher than the former.

A Wide Dynamic Range NUC Algorithm for IRCS Systems

  • Cai, Li-Hua;He, Feng-Yun;Chang, Song-Tao;Li, Zhou
    • Journal of the Korean Physical Society
    • /
    • 제73권12호
    • /
    • pp.1821-1826
    • /
    • 2018
  • Uniformity is a key feature of state-of-the-art infrared focal planed array (IRFPA) and infrared imaging system. Unlike traditional infrared telescope facility, a ground-based infrared radiant characteristics measurement system with an IRFPA not only provides a series of high signal-to-noise ratio (SNR) infrared image but also ensures the validity of radiant measurement data. Normally, a long integration time tends to produce a high SNR infrared image for infrared radiant characteristics radiometry system. In view of the variability of and uncertainty in the measured target's energy, the operation of switching the integration time and attenuators usually guarantees the guality of the infrared radiation measurement data obtainted during the infrared radiant characteristics radiometry process. Non-uniformity correction (NUC) coefficients in a given integration time are often applied to a specified integration time. If the integration time is switched, the SNR for the infrared imaging will degenerate rapidly. Considering the effect of the SNR for the infrared image and the infrared radiant characteristics radiometry above, we propose a-wide-dynamic-range NUC algorithm. In addition, this essasy derives and establishes the mathematical modal of the algorithm in detail. Then, we conduct verification experiments by using a ground-based MWIR(Mid-wave Infared) radiant characteristics radiometry system with an Ø400 mm aperture. The experimental results obtained using the proposed algorithm and the traditional algorithm for different integration time are compared. The statistical data shows that the average non-uniformity for the proposed algorithm decreased from 0.77% to 0.21% at 2.5 ms and from 1.33% to 0.26% at 5.5 ms. The testing results demonstrate that the usage of suggested algorithm can improve infrared imaging quality and radiation measurement accuracy.

성상신경절 부위의 직선편광 근적외선 조사 후 요골동맥에서의 혈류속도의 변화: 성상신경절 차단술과의 비교 (The Change of Blood Flow Velocity of Radial Artery after Linear Polarized Infrared Light Radiation near the Stellate Ganglion: Comparing with the Stellate Ganglion Block)

  • 한승문;이상철
    • The Korean Journal of Pain
    • /
    • 제14권1호
    • /
    • pp.37-40
    • /
    • 2001
  • Background: It had been reported by authors that linear polarized infrared light radiation (Superizer: SL) near the stellate ganglion had a similar effect on the change of skin temperature of hand compared with the stellate ganglion block (SGB). We hypothesized that this was due to dilatation of vessels and an increased blood flow. The aim of this study was to measure the velocity of blood flow in peripheral vessels after linear polarized infrared light radiation near the stellate ganglion and to compare the effect of SL with that of SGB using local anesthetics. Methods: Forty patients whose clinical criteria were matched for the symptoms of SGB were selected for study. We radiated the stellate ganglion by linear polarized infrared light radiation and measured the blood flow of radial artery using Ultrasound Doppler blood flow meter before and after 10, 20 and 30 minutes post-radiation. After 3 days, SGB was performed using 8 ml of 1% mepivacaine to the same patient, and the radial artery blood flow was measured in the same manner. Results: The blood flow velocity was increased by 40% and 27% at 10 min and 20 min after SL and by 42% and 41% at 10 min and 20 min after SGB. However, there was no statistically significant difference in blood flow velocity between SGL and SGB. Conclusions: We could conclude that linear polarized radiation is a clinically simple and useful noninvasive therapeutic tool in clinical area.

  • PDF

INFRARED SPECTRAL ENERGY DISTRIBUTION OF GALAXIES IN THE AKARI ALL SKY SURVEY: CORRELATIONS WITH GALAXY PROPERTIES AND THEIR PHYSICAL ORIGIN

  • Makiya, R.;Totani, T.;Takeuchi, T.T.;Nagashima, M.;Kobayashi, M.A.R.
    • 천문학논총
    • /
    • 제27권4호
    • /
    • pp.325-329
    • /
    • 2012
  • We will report our recent study on the properties of more than 1,600 galaxies detected by the AKARI All-Sky Survey with physical quantities based on optical and 21-cm observations, to understand the physics determining the infrared spectral energy distribution (Totani et al., 2011). We discover a tight linear correlation for normal star-forming galaxies between the radiation field strength of dust heating (corresponding to dust temperature) and the galactic-scale infrared radiation field, $L_{TIR}/R^2$. This is the tightest correlation of dust temperature ever known, and the dispersion along the mean relation is 13% in dust temperature. This relation can be explained physically by a thin layer of heating sources embedded in a thicker, optically-thick dust screen. We also find that the number of galaxies sharply drops when galaxies become optically thin against dust-heating radiation, indicating that a feedback process to galaxy formation (e.g., by the photoelectric heating) is working when dust-heating radiation is not self-shielded on a galactic scale. We discuss implications from these findings for the $M_{H_I}$ -size relation, the Kennicutt-Schmidt relation, and galaxy formation in the cosmological context.

복사 차폐막이 극저온 용기의 부하에 미치는 영향에 관한 실험적 연극 (An Experimental Study on the Effects of a Radiation Shield on the Thermal Load of a Cryochamber)

  • 김영민;박성제;강병하
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.365-370
    • /
    • 2005
  • Infrared (lR) detectors are widely used for such applications as thermoelstic stress analysis, medical diagnostics and temperature measurement. Infrared detectors commonly need to be refrigerated below 80 K, and thus a cooling system should be equipped together with the detector system. The cooling load, which should be removed by the cooling system to maintain the nominal operating temperature of the detector, critically depends on the insulation efficiency of the cryochamber housing the detector. Cryochamber considers the conduction heat transfer through a cold finger, the gases conduction and radiation heat transfer. The thermal loads of an infrared detector Cryochamber with radiation shield are investigated experimentally in present study. Since the effect of radiation heat transfer on thermal loads is significant, radiation shields is installed in the cold finger part to protect heat input through radiation. It is found that the thermal load can be substantially reduced by increasing the number of radiation shield.

  • PDF

직선 편광 근적외선 조사가 건강인의 실험적 통증역치에 미치는 영향 (Effect of Linear Polarized Near-Infrared Ray Radiation on the Experimental Pain Threshold in Healthy Subjects)

  • 이재형;송인영;최은영
    • 대한물리치료과학회지
    • /
    • 제2권4호
    • /
    • pp.771-778
    • /
    • 1995
  • 편광 근적외선 조사가 실험적 통증역치에 영향을 미치는지를 규명하기 위해서 건강한 성인의 합곡혈에 여러 단계의 출력량으로 편광 근적외선을 30초간 조사하고 시간 경과에 따라 실험적 통증역치를 측정하여 분석하였다. 실험 결과 출력량 0 %인 대조군과 10 % 및 20 %의 출력량에서는 실험적 통증역치의 유의한 변화가 없었다. 그러나 출력량 40 %군의 실험적 통증역치는 편광 근적외선 조사전 $3.85{\pm}0.51mA$에서 조사 직후 $4.77{\pm}0.87mA$, 조사 후 30분 $5.57{\pm}0.98mA$, 조사 후 1시간 $5.68{\pm}1.06mA$, 조사 후 2시간 $5.34{\pm}0.96mA$로 증가되었고, 출력량 80 %군에서도 실험적 통증역치가 조사전 $3.87{\pm}0.92mA$에서 조사 직후 $4.45{\pm}0.62mA$, 조사 후 30분 $4.91{\pm}0.51mA$, 조사 후 1시간 $4.93{\pm}0.62mA$, 조사 후 2시간 $5.55{\pm}1.11mA$로 증가하였다. 실험적 통증역치는 편광 근적외선 조사 직후부터 2시간까지 유의하게 증가하였다. 40 % 출력량과 80 % 출력량의 실험적 통증역치는 유의한 차이가 없었고, 출력량과 시간의 상호작용효과는 없었다. 건강인의 실험적 통증역치를 대상으로 한 본 연구 결과를 통증이 있는 환자에게 직접 적용하기는 어렵다고 생각하며 앞으로 환자를 대상으로한 연구가 수행되기를 기대한다.

  • PDF

Photoimmunological and Photobiological Action of Infrared Radiation

  • Danno, Kiichiro
    • Journal of Photoscience
    • /
    • 제9권2호
    • /
    • pp.194-196
    • /
    • 2002
  • While ultraviolet radiation alters various cutaneous cell functions, little is known about photo-immunological and photobiological effects of infrared radiation (IR) on the skin except its local thermal effects. The fIrst part of this study demonstrated that single exposure of mouse skin to near IR (0.7 - 1.3 $\mu$m) reversibly suppressed the proliferating activity of the epidermis, the density of Langerhans cells, and the ability of skin to induce contact hypersensitivity reaction. The second part demonstrated that the rate of wound closure was significantly accelerated by repeated exposures in animal models. The production of transforming growth factor-$\beta$l and matrix metalloproteinase-2, which are responsible for the wound healing processes, was significantly upregulated by irradiation, as shown by enzyme immunoassay, zymography, and reverse transcription polymerase chain reaction. Thermal controls were negative. The results suggest that near-IR irradiation can modulate the epidermal proliferation and part of the skin immune system, and stimulate the wound healing processes, presumably by non-thermal effects.

  • PDF