• 제목/요약/키워드: infrared lamp

Search Result 118, Processing Time 0.024 seconds

Development and Performance Property Investigation of Lighting System using Plastic Optical Fiber (플라스틱 광섬유를 이용한 조명시스템 개발과 특성 분석)

  • Shin, Sang-Uk;Yi, Chin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.25-32
    • /
    • 2010
  • Compared to general lighting method, the lighting system that uses optic fiber can provide only the visible light of good quality to subject by eliminating ultraviolet ray and infrared ray. Thanks to this merit, it is possible to prevent the hard phenomenon of subject caused by ultraviolet ray and infrared ray and to provide the agreeable light environment. This study developed indoors illumination system of high color rendering on the basis of plastic optic fiber with excellent optical property and processing to substitute halogen lamp which has been used for excellent color rendering in spite of low efficiency and short life. Producing pilot product of the designed illumination system and evaluating the property of electric and optical property, ultraviolet ray radiation quantity and temperature property, this study verified the excellence of suggested lighting system of plastic optic fiber.

A Study on the Development of a pub level Silica Measuring Technology by the Split-beam Type System (스플리트빔 형태의 고정도 단위 실리카 측정기술 개발에 관한 연구)

  • 정경열;류길수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.382-388
    • /
    • 2002
  • Dissolved silica is one of fatal components at a boiler facility Therefore, a dissolved silica measurement system should be equipped for managing efficiently the boiler facility. Most of silica measurement systems are composed of a sensor module of single-beam type structure, and silica density is measured with a infrared spectrometry using the Lambert-beer method. However, such a system occurs measuring error of large range and inconsistency of a light source, because of measuring a standard sample and a measuring sample alternatively. This paper introduces a method that the sensor module has a split-beam type structure and a tungsten lamp. The proposed system can measure silica density quickly and precisely more than those composing of a single-beam type structure, because of measuring and comparing with two samples at a same time. And examination results are shown to compare efficiencies of the system and existing commercial products, and for an ammonia influence.

Electrical Property Evaluation of Printed Copper Nano-Ink Annealed with Infrared-Lamp Rapid Thermal Process (적외선 램프를 이용하여 소결한 구리 나노잉크의 전기적 특성 평가에 관한 연구)

  • Han, Hyun-Suk;Kim, Changkyu;Yang, Seung-Jin;Kim, Yoon-Hyun
    • Korean Journal of Materials Research
    • /
    • v.26 no.4
    • /
    • pp.216-221
    • /
    • 2016
  • A sintering process for copper based films using a rapid thermal process with infrared lamps is proposed to improve the electrical properties. Compared with films produced by conventional thermal sintering, the microstructure of the copper based films contained fewer internal and interfacial pores and larger grains after the rapid thermal process. This high-density microstructure is due to the high heating rate, which causes the abrupt decomposition of the organic shell at higher temperatures than is the case for the low heating rate; the high heating rate also induces densification of the copper based films. In order to confirm the effect of the rapid thermal process on copper nanoink, copper based films were prepared under varying of conditions such as the sintering temperature, time, and heating rate. As a result, the resistivity of the copper based films showed no significant changes at high temperature ($300^{\circ}C$) according to the sintering conditions. On the other hand, at low temperatures, the resistivity of the copper based films depended on the heating rate of the rapid thermal process.

Development of preheating technology on energy-saving extrusion dies applying infrared lamp (근적외선 램프를 적용한 에너지 절감형 압출금형 예열기술 개발)

  • Min, Kyung-Ho;Bae, Seong-Hwan;Choi, Ho-Joon;Shin, Young-Chul
    • Design & Manufacturing
    • /
    • v.11 no.1
    • /
    • pp.7-13
    • /
    • 2017
  • The aim of this study is to develop the dies oven for energy-saving during the pre-heated process of extrusion dies. Applying high-efficiency near-infrared heater, single cell type dies oven was developed as a substitute for traditional chest type oven. Therefore the dies is individually heated uniformly to operation temperature so rapidly. By using the developed dies oven, electric-energy consumption of preheating extrusion dies reduced up to 30% and the waiting time in the oven also minimized up to 90min. In addition, the results have shown that it is possible to accurately control the dies temperature for improving the quality of extruded profile and to minimize die bearing oxidation and nitride layer degradation responsible for surface defects on the profile and shorter die life.

Application Angle of Defects Detection in the Pipe Using Lock-in Infrared Thermography (위상잠금 적외선 열화상 기법을 이용한 각도별 원전 감육 배관의 결함 검출)

  • Yun, Kyung-Won;Go, Gyeong-Uk;Kim, Jin-Weon;Jung, Hyun-Chul;Kim, Kyung-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.4
    • /
    • pp.323-329
    • /
    • 2013
  • This perform research of angle rated defect detection conditions and nuclear power plant piping defect detection by lock-In infrared thermography technique. Defects were processed according to change for wall-thinning length, Circumference orientation angle and wall-thinning depth. In the used equipment IR camera and two halogen lamps, whose full power capacitany is 1 kW, halogen lamps and target pipe's distance fixed 2 m. To analysis of the experimental results ensure for the temperature distribution data, by this data measure for defect length. Reliability of lock-In infrared thermography data is higher than Infrared thermography data. This through research, Shape of angle rated defect is identified industry place. It help various angles defect detection in the nuclear power plant in operation.

Proper Installation Distance for Heating Effect of Nano-Carbon Fiber Infrared Heating Lamp for Stable Production of Watermelon Grafted Seedlings in Winter Season (동절기 수박 접목묘의 안정적 생산을 위한 나노탄소섬유적외선 램프의 난방효과에 대한 적정 설치간격)

  • Kim, Hye Min;Jeong, Hyeon Woo;Hwang, Hee Sung;Hwang, Seung Jae
    • Journal of Bio-Environment Control
    • /
    • v.31 no.1
    • /
    • pp.8-13
    • /
    • 2022
  • This study was carried out to investigate the proper wattage and installation distance for the efficient use of nano-carbon fiber infrared heating lamp (NCFIHL), a heating device advantageous for heating energy saving, when the production of watermelon plug seedlings in the plug seedling nursery in winter season. Six small beds were divided into plastic film, and 700 W and 900 W nano-carbon fiber infrared heating lamps were installed at 100 cm above the bed. 1 lamp at central (control), 60 cm interval (2 lamps), and 40 cm interval (3 lamps) heating lamps were installed in each bed inside the greenhouse. All treatments, except the control, were set to keep the night air temperature at 20℃ after lighting the NCFIHL. The leaf temperature showed a tendency to increase fast as the install distance was narrow. The leaf length and leaf width tended to increase as the installation distance of the 700 W heating lamp was narrow. The compactness was high in 700 W heating lamp with 40 cm of installation distance. Therefore, in consideration of maintaining the set temperature at night, installing 700 W electric lamps at 40 cm was an efficient power and installation distance for watermelon grafted seedlings considering economic feasibility.

Electrical Characteristics of 28w class-Piezoelectric Transformer for Fluorescent Lamp Ballast as a function of Load Resistance (형광등 안정기용 고출력 (28W급)압전트랜스포머의 부하저항에 따른 전기적 특성)

  • Hwang, S.M.;Lee, J.S.;Yoo, J.H.;Park, C.Y.;Lee, S.H.;Lee, S.I.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.135-139
    • /
    • 2001
  • Contour vibration mode piezoelectric transformers were designed and fabricated to the square plate with size of $27.5{\times}27.5{\times}2.5(2.6,\;3.0)mm^3$ using PNW-PMN-PZT ceramics. Electrical characteristics of the piezoelectric transformer were investigated for fluorescent lamp ballast application. The electrical properties and characteristic temperature rise were measured using oscilloscope and infrared temperature sensor. A 28W fluorescent lamp was successfully driven by the fabricated transformers. After driving the lamp using Power Amplifier for 24 min, the output power, efficiency and characteristic temperature rise of PT2 piezoelectric transformer showed the appropriate values of 28.01 W, 99.43% and $11^{\circ}C$, respectively. The electronic ballast using PT2 piezoelectric transformer showed an excellent output power of 28.85 W and efficiency of 86.3%, respetively.

  • PDF

Analysis on IEC 62471 for The Introduction of Photobiological Safety of LED Lamp (LED조명의 광생물학적안전성 도입을 위한 IEC 62471 규격 분석)

  • Ko, Jae-Kyu;Cho, Mee-Ryoung;Lee, Min-Jin;Kim, Ju-Hyun
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2012.11a
    • /
    • pp.435-443
    • /
    • 2012
  • First introduced in 1962, LED(light-emitting diodes) emitted low-intensity red light, but modern versions are now available across the ultraviolet, visible, and infrared spectrum, many with very high luminance or brightness. As a result, growing importance of potential safety harzards for human. Now when certificated of CE provide that testing through IEC/EN 62471 for any lamp. Korea standard adopted as it IEC 62471:2006, Photobiological safety of lamps and lamp systems without change, but effectiveness is incomplete. In this paper, we introduce analysis and direction that urgently come into effectiveness of KS C IEC 62471 as a national standard specifications.

  • PDF

Development of New Cancer Therapy and Its Physics

  • Oh, Hung-Kuk;Jeong, Jin-Ha
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.05a
    • /
    • pp.147-155
    • /
    • 2001
  • Nasucon lamp and Russian ones, which are coated with some special materials on the glass bulb, gave good clinical results for a cancer therapy. They are experimentally studied with Automatic Bioelectric Response Recorder on the six placements of the electrodes (two feet, two hands and two foreheads). They reduced the current rather than the control (natural) state. However infrared lamp and Chinese God light did not reduced the value current. Hemoglobin in blood. Brown gas, Ti$_3$SiC$_2$ and Nasucon have planar crystallizing $\pi$-bonding bonding layer and covalent bonding one in sequence commonly and thus the alternating magnetic fields are protected. Nasucon lamp and Russian ones utilized electric bulbs in order to generate alternating magnetic fields and to produce absorbing force.

  • PDF

Electrical Characteristics of T5(28W) Fluorescent Lamp Ballast Circuit using Piezoelectric Transformer (압전트랜스포머를 이용한 T5(28W) 형광등 안정기 회로의 전기적 특성)

  • 황상모;류주현;황락훈;김주래;홍재일;박창엽;김종선
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.9
    • /
    • pp.736-743
    • /
    • 2001
  • Contour vibration mode piezoelectric transformers were designed and fabricated to the square plate with size of 27.5x27.5x2.6㎟ using PNW-PMN-PZT ceramics. Electrical characteristics of the piezoelectric transformer were investigated for fluorescent lap ballast application. The electrical properties and characteristic temperature rise were measured by oscilloscope and infrared temperature sensor. A 28W fluorescent lamp was successfully driven by the fabricated transformers. The electronic ballast using piezoelectric transformer showed an excellent output power of 28.85[W], efficiency of 86.3% and characteristic temperature rise of 15[$\^{C}$].

  • PDF