• 제목/요약/키워드: infinite delay

검색결과 62건 처리시간 0.026초

Thermo-mechanical response of size-dependent piezoelectric materials in thermo-viscoelasticity theory

  • Ezzat, Magdy A.;Al-Muhiameed, Zeid I.A.
    • Steel and Composite Structures
    • /
    • 제45권4호
    • /
    • pp.535-546
    • /
    • 2022
  • The memory response of nonlocal systematical formulation size-dependent coupling of viscoelastic deformation and thermal fields for piezoelectric materials with dual-phase lag heat conduction law is constructed. The method of the matrix exponential, which constitutes the basis of the state-space approach of modern control theory, is applied to the non-dimensional equations. The resulting formulation together with the Laplace transform technique is applied to solve a problem of a semi-infinite piezoelectric rod subjected to a continuous heat flux with constant time rates. The inversion of the Laplace transforms is carried out using a numerical approach. Some comparisons of the impacts of nonlocal parameters and time-delay constants for various forms of kernel functions on thermal spreads and thermo-viscoelastic response are illustrated graphically.

오존발생장치용 정출력 전원장치의 개발 (Development of Constant Output Power Supply System for Ozonizer)

  • 우정인;우성훈;노인배;박지호;김동완
    • 조명전기설비학회논문지
    • /
    • 제19권7호
    • /
    • pp.113-121
    • /
    • 2005
  • 본 논문에서는 오존발생장치의 전원측 파형에 포함되는 고주파수의 노이즈를 제거하고, 디지털 궤환 제어에 의해 오존 출력을 제어하기 위하여 전원장치의 출력측 LC 필터와 방전관 용량으로부터 커패시터 전압과 전류를 검출하여 2중의 제어루프를 설계하였다. 디지털 제어기의 연산지연시간을 보상하기 위하여 연산지연시간을 전원장치 플랜트의 고유한 파라미터로 가정하고, 플랜트 모델에 포함시켜 모델링 하였다. 오존발생장치의 부하변동에 따르는 과도상태 응답특성을 개선하고, 파라미터 변동에 강인한 특성을 얻기 위하여 내부 전류 모델 제어기를 제안하였다. 또한 오존발생장치용 전원장치에서 영 오차의 정상 상태를 얻기 위하여 외부 전압 제어루프를 구성하여 비례 제어기와 공진 제어기를 병렬로 연결한 비례-공진 전압제어기를 제안하였다.

UPS 인버터의 성능 개선을 위한 강인한 2중 디지털 제어기의 설계 (Design of Robust Double Digital Controller to Improve Performance for UPS Inverter)

  • 박지호;노태균;김춘삼;안인모;우정인
    • 전력전자학회논문지
    • /
    • 제8권2호
    • /
    • pp.116-127
    • /
    • 2003
  • 본 논문에서는 UPS 인버터의 성능 개선을 위하여 출력측 LC 필터의 커패시터 전압과 전류의 2중 제어루프를 구성하고, 2중 제어루프에 디지털 제어시스템을 채택하였다 또한, 디지털 제어기의 연산지연시간을 보상하기 위하여 이러한 연산지연시간을 인버터 플랜트의 고유한 파라미터로 가정하고, 플랜트 모델에 포함시켜 모델링 하였다. UPS 인버터 출련전압의 과도상태 응답특실을 개선하고, 파라미터 변동에 강인한 특성을 얻기 위하여 2중 제어루프에서 내부 전류 제어루프는 내부 모델 제어기를 제안하였다. UPS 인버터 출력전압의 0의 정상상태 오차를 얻기 위하여 외부 전압 제어루프는 비례 제어기와 공진 제어기를 병렬로 연결한 비례-공진 진압제어기를 제안하였다.

UPS 인버터의 디지털 제어기 및 모니터링 시스템의 개발 (Development of Digital Controller and Monitoring System for UPS Inverter)

  • 박지호;황기현;김동완
    • 전자공학회논문지SC
    • /
    • 제44권1호
    • /
    • pp.1-11
    • /
    • 2007
  • 본 논문에서는 UPS 인버터의 성능 개선을 위하여 출력측 LC 필터의 커패시터 전압과 전류의 2중 제어루프를 구성하고, 2중 제어루프에 디지털 제어시스템을 설계하였다. 또한, 디지털 제어기의 연산지연시간을 보상하기 위하여 이러한 연산지연시간을 인버터 플랜트의 고유한 파라미터로 가정하고, 플랜트 모델에 포함시켜 모델링 하였다. UPS 인버터 출력전압의 과도상태 응답특성을 개선하고, 파라미터 변동에 강인한 특성을 얻기 위하여 2중 제어루프에서 내부 전류 제어루프는 내부 모델 제어기를 제안하였다. UPS 인버터 출력전압의 0의 정상상태 오차를 얻기 위하여 외부 전압 제어루프는 비례 제어기와 공진 제어기를 병렬로 연결한 비례-공진 전압제어기를 제안하였다. 또한, 사용자에게 쉽게 UPS의 동작 상태를 표시하기 위하여 그래픽 사용자 인터페이스를 이용한 UPS의 모니터링 시스템을 구현하였다.

위성탑재 CICQ Crossbar Switch에서 COS 지원을 위한 프리미엄기반 우선순위 Scheduler 기법 (A Scheduling Scheme based on Premium to Support COS(Class of Service) for Satellite On-Board CICQ(Combined Input-Crosspoint Queueing) Crossbar Switch)

  • 공남수;류근호;이규호
    • 한국정보통신학회논문지
    • /
    • 제13권6호
    • /
    • pp.1065-1071
    • /
    • 2009
  • 위성을 통한 통신 서비스는 음성 통신 서비스와 같은 실시간 응용 서비스와 데이터 통신과 같은 비실시간 응용 서비스가 함께 제공되는 것이 일반적이다. 위성을 통하여 특성을 달리하는 여러 개의 응용 서비스를 함께 제공하기 위해서는 서비스의 클래스(COS : Class of Service)에 따라 우선순위를 달리하는 우선순위 스케줄링이 필요하다. 그러나 기존의 우선순위 스케줄링 기법은 우선순위가 낮을 경우, 서비스를 받지 못하는 굶주림(Starvation) 현상이 발생하는 문제점이 있었다. 본 논문에서는 COS에 따라 각기 다른 프리미엄을 주고, 스케줄링을 받지 못한 패킷은 Age를 증가시켜 가면서, Age와 프리미엄의 합이 가장 큰 패킷을 선택하는 프리미엄 기반 우선순위 스케줄링 기법을 제안한다. 제안한 스케줄링 기법은 고정 우선순위 스케줄링 기법에 비하여 우선순위가 낮은 서비스에 있어서 평균지연시간이 개선되었고, 지연시간에 대한 표준편차에 있어서도 기존의 고정 우선순위 기법에 비하여 개선되었음을 보여 주였다. 제안한 프리미엄 기반 우선순위 스케줄링 기법에서는 기존의 고정 우선순위 스케줄링 기법에서와 같은 무한정 굶주림 상태가 되지 않는다.

양자화 입력을 고려한 연속시간 T-S 퍼지 시스템을 위한 이벤트 트리거 모델예측제어 (Event-Triggered Model Predictive Control for Continuous T-S fuzzy Systems with Input Quantization)

  • 권우경;이상문
    • 전기학회논문지
    • /
    • 제66권9호
    • /
    • pp.1364-1372
    • /
    • 2017
  • In this paper, a problem of event-triggered model predictive control is investigated for continuous-time Takagi-Sugeno (T-S) fuzzy systems with input quantization. To efficiently utilize network resources, event-trigger is employed, which transmits limited signals satisfying the condition that the measurement of errors is over the ratio of a certain level. Considering sampling and quantization, continuous Takagi-Sugeno (T-S) fuzzy systems are regarded as a sector bounded continuous-time T-S fuzzy systems with input delay. Then, a model predictive controller (MPC) based on parallel distributed compensation (PDC) is designed to optimally stabilize the closed loop systems. The proposed MPC optimize the objective function over infinite horizon, which can be easily calculated and implemented solving linear matrix inequalities (LMIs) for every event-triggered time. The validity and effectiveness are shown that the event triggered MPC can stabilize well the systems with even smaller average sampling rate and limited actuator signal guaranteeing optimal performances through the numerical example.

밀폐된 원통형 분무 연소기내의 자연발화 현상에 관한 수치적 연구 (A Numerical Study of Autoignition in a Confined Cylindrical Spray Combustor)

  • 최지훈;백승욱
    • 대한기계학회논문집B
    • /
    • 제23권6호
    • /
    • pp.778-787
    • /
    • 1999
  • In this study, the autoignition process of liquid fuel, injected into hot and stagnant air in a 2-D axisymmetric confined cylindrical combustor, has been investigated. Eulerian-Lagrangian scheme was adopted to analyze the two-phase flow and combustion. The unsteady conservation equations were used to solve the transition of the gas field. Interactions between two phases were accounted by using the particle source in cell (PSI-Cell) model, which was used for detailed consideration of the finite rates of transports between phases. And infinite conduction model was adopted for the vaporization of droplets. The results have shown that the process of the autoignition consists of heating up of droplets, vaporization, mixing and ignition. The ignition criteria could be determined by the temporal variations of temperature, reaction rate and species mass fraction. And the effects of various parameters on ignition phenomena are examined. These have shown that the increasing the reaction rate and/or the vaporization rate can reduce the ignition delay time.

IGNITION OF REACTIVE SOLIDS WITH ROUGH SURFACE BY CONSTANT HEAT FLUX

  • Chae, J.O.;Mokhin, G.N.;Moon, J.I.;Shmelev, V.M.
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 1995년도 제5회 학술강연회논문집
    • /
    • pp.11-30
    • /
    • 1995
  • The ignition characteristics of a reactive solid with rough surface by constant heat flux were studied. The geometry of surface was represented by a set of identical protrusions having a shape of wedge based on the block of reactive solid. Several regimes of ignition were found, depending on the ratio of the protrusion length and the depth of the heated layer, formed in course of ignition process: 1) when the substance is ignited as the massive block, and the effect of roughness is not pronounced; 2) when ignited are the individual protrusions; and 3) in the intermediate region between the first two. Critical ignition conditions: ignition time and ignition criterion, are determined for the three regimes. The results are compared with the results for the one-dimensional ignition of the semi-infinite body. It is shown, that the effect of geometry on ignition results in the considerable reduction of ignition delay, and the amount of energy required for the successful ignition is less compared to the one- dimensional case.

  • PDF

Hybrid 가드채널이 있는 이동통신시스템이 성능 평가 (Performance Analysis of a Cellular Mobile Communication System with Hybrid Guard Channels)

  • 홍성조;최진영
    • 산업경영시스템학회지
    • /
    • 제29권4호
    • /
    • pp.100-106
    • /
    • 2006
  • We analyze a voice/data integrated traffic model of the cellular mobile communication system with hybrid guard channels for voice and handoff calls. In a multi-service integrated wireless environment, quality of service guarantee is crucial for smooth transportation of real time information. Real time voice traffic requires a guaranteed upper bounded on both delay and packet error rate, whereas data traffic does not. Voice traffic has high transmission priority over data packets. Thus one of the important problems is the design of admission control schemes which can efficiently accommodate the differential quality of service requirements. In this paper, a hybrid guard channel scheme is considered in which arriving calls are assigned channels as long as the number of busy channels in the cell is below a predetermined first threshold. When the number of busy channels reaches the first threshold, new originating data calls are queued in the infinite data buffer. Then reaches second threshold, only handoff calls are assigned the remaining channels and new originating voice calls are blocked. We evaluate the system by a two-dimensional Markov chain approach and generating function method and obtain performance measures included blocking probability and forced termination probability.

Impact of playout buffer dynamics on the QoE of wireless adaptive HTTP progressive video

  • Xie, Guannan;Chen, Huifang;Yu, Fange;Xie, Lei
    • ETRI Journal
    • /
    • 제43권3호
    • /
    • pp.447-458
    • /
    • 2021
  • The quality of experience (QoE) of video streaming is degraded by playback interruptions, which can be mitigated by the playout buffers of end users. To analyze the impact of playout buffer dynamics on the QoE of wireless adaptive hypertext transfer protocol (HTTP) progressive video, we model the playout buffer as a G/D/1 queue with an arbitrary packet arrival rate and deterministic service time. Because all video packets within a block must be available in the playout buffer before that block is decoded, playback interruption can occur even when the playout buffer is non-empty. We analyze the queue length evolution of the playout buffer using diffusion approximation. Closed-form expressions for user-perceived video quality are derived in terms of the buffering delay, playback duration, and interruption probability for an infinite buffer size, the packet loss probability and re-buffering probability for a finite buffer size. Simulation results verify our theoretical analysis and reveal that the impact of playout buffer dynamics on QoE is content dependent, which can contribute to the design of QoE-driven wireless adaptive HTTP progressive video management.