• 제목/요약/키워드: inductive loop

검색결과 56건 처리시간 0.026초

복합형GLVQ 신경망을 이용한 차종분류 모형개발 (The Development of a Model for Vehicle Type Classification with a Hybrid GLVQ Neural Network)

  • 조형기;오영태
    • 대한교통학회지
    • /
    • 제14권4호
    • /
    • pp.49-76
    • /
    • 1996
  • Until recently, the inductive loop detecters(ILD) have been used to collect a traffic information in a part of traffic manangment and control. The ILD is able to collect a various traffic data such as a occupancy time and non-occupancy time, traffic volume, etc. The occupancy time of these is very important information for traffic control algorithms, which is required a high accuracy. This accuracy may be improved by classifying a vehicle type with ILD. To classify a vehicle type based on a Analog Digital Converted data collect form ILD, this study used a typical and modifyed statistic method and General Learning Vector Quantization unsuperviser neural network model and a hybrid model of GLVQ and statistic method, As a result, the hybrid model of GLVQ neural network model is superior to the other methods.

  • PDF

MAGLEV 차량의 실시간 속도 및 위치 검출 (Real-time speed and position detection of MAGLEV vehicle system)

  • 윤여원;박석하;함상용;손영수;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.346-348
    • /
    • 1997
  • This paper presents microprocessor-based real-time speed and position detection by inductive radio loop in new transportation system, such as magnetically levitated train system, rubber tyred train, and linear-motor car. The constant elapsed time method is used in this study for high accurate detection over a wide speed range. And for reliability and safety of the system, it is duplicated and data-bus level comparison is performed by fail-safe comparator.

  • PDF

MAGLEV 정보 송수신상의 노이즈 억제에 관한 연구 (The Noise Suppression of Data Transmission in MAGLEV)

  • 김종범;이준구;박석하;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.362-364
    • /
    • 1998
  • The transmission of information by inductive loop is required for train-safety and fast running. FSK modulation has been used for transmission of information in fast running. Transmission channel between train and ground must be protected from interference of power line. To protect transmission data from noises, the analysis on the transmission line must be performed in advance. In this paper, transmission line is analyzed in view of reflection and time delay in both noise and signal.

  • PDF

Automatic Power Factor Correction Using a Harmonic-Suppressed TCR Equipped with a New Adaptive Current Controller

  • Obais, Abdulkareem Mokif;Pasupuleti, Jagadeesh
    • Journal of Power Electronics
    • /
    • 제14권4호
    • /
    • pp.742-753
    • /
    • 2014
  • In this paper, a new continuously and linearly controlled capacitive static VAR compensator is proposed for the automatic power factor correction of inductive single phase loads in 220V 50Hz power system networks. The compensator is constructed of a harmonic-suppressed TCR equipped with a new adaptive current controller. The harmonic-suppressed TCR is a new configuration that includes a thyristor controlled reactor (TCR) shunted by a passive third harmonic filter. In addition, the parallel configuration is connected to an AC source via a series first harmonic filter. The harmonic-suppressed TCR is designed so that negligible harmonic current components are injected into the AC source. The compensator is equipped with a new adaptive closed loop current controller, which responds linearly to reactive current demands. The no load operating losses of this compensator are negligible when compared to its capacitive reactive current rating. The proposed system is validated on PSpice which is very close in terms of performance to real hardware.

광대역 주입동기식 주파수 분주기 기반 40 GHz CMOS PLL 주파수 합성기 설계 (Design of a 40 GHz CMOS Phase-Locked Loop Frequency Synthesizer Using Wide-Band Injection-Locked Frequency Divider)

  • 남웅태;손지훈;신현철
    • 한국전자파학회논문지
    • /
    • 제27권8호
    • /
    • pp.717-724
    • /
    • 2016
  • 본 논문은 60 GHz 슬라이딩-IF 구조 RF 송수신기를 위한 40 GHz CMOS PLL 주파수 합성기 설계를 다룬다. 광대역에서 안정적인 주입동기식 주파수 합성기 동작을 위하여 인덕티브 피킹 기법을 이용한 주파수 분주기가 설계되었다. 광대역 주파수 분주기는 PLL이 전압 제어 발진기의 전체 주파수 범위에서 안정적으로 동기되는 것을 보장한다. 또한, 전압 제어 발진기와 주입동기식 주파수 분주기 사이의 원치 않는 간섭을 없애기 위하여 주입동기식 버퍼를 설계하여 적용하였다. 설계된 PLL 주파수 합성기는 65 nm CMOS 공정을 이용하여 설계되었으며, 37.9~45.3 GHz 출력 주파수 범위를 갖는다. 1.2 V 전원 전압에서 버퍼 포함 74 mA의 전류를 소모한다.

자기장을 이용한 루프검지기 자동진단시스템 개발 (Development of an Automatic Comprehensive Condition Diagnosis System for Inductive Loop Detector Using Magnetic Field)

  • 김남선;이승환;오영태;이철기;강증식
    • 대한교통학회지
    • /
    • 제23권5호
    • /
    • pp.123-134
    • /
    • 2005
  • 본 연구는 기존의 루프검지기의 설치 및 유지보수를 위한 성능평가 방법으로서 사용해왔던 L-R-C(Inductance-Resistance-Capacitance) Test에 의한 Q Factor(질 계수)방법을 대체/보완할 수 있는 새로운 방법에 대한 연구이다. 기존의 Q Factor방법은 크게 세 가지 문제점을 수반하고 있다. 첫째, 현장의 루프검지기의 전기적 특성인 L-R-C값을 Q Factor를 기준으로 루프검지기의 현재 성능을 평가함으로써 인력에 의존하는 효율성에 문제를 안고 있으며 둘째, 루프검지시스템의 전체를 대상으로 하지 않고 일부의 측정치만으로 전체시스템을 추론하고 있다는 점과 셋째, 기존의 방법으로는 루프검지기의 검지영역, 즉 높이별 검지영역를 알 수 없다는 것이다. 따라서 본 연구에서는 이러한 문제점을 보완할 수 있는 방법으로서 루프검지기헤드에서 발생하는 자기장을 측정하여 루프검지기 전체시스템의 현재상태를 파악하고자 하였다. 이를 위하여 루프검지기에서 생성되는 자기장을 검출할 수 있는 센서와 자료수집방법, 분석방법 및 진단방법 등을 개발하였다.

Corrosion Inhibition Performance of Two Ketene Dithioacetal Derivatives for Stainless Steel in Hydrochloric Acid Solution

  • Lemallem, Salah Eddine;Fiala, Abdelali;Ladouani, Hayet Brahim;Allal, Hamza
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권2호
    • /
    • pp.237-253
    • /
    • 2022
  • The methyl 2-(1,3-dithietan -2- ylidene)-3-oxobutanoate (MDYO) and 2-(1,3-dithietan-2-ylidene) cyclohexane -1,3-dione (DYCD) were synthesized and tested at various concentrations as corrosion inhibitors for 316L stainless steel in 1 M HCl using weight loss, electrochemical impedance spectroscopy (EIS), potentiodynamic polarization (PDP), surface analysis techniques (SEM / EDX and Raman spectroscopy) and Functional Density Theory (DFT) was also used to calculate quantum parameters. The obtained results indicated that the inhibition efficiency of MDYO and DYCD increases with their concentration, and the highest value of corrosion inhibition efficiency was determined in the range of concentrations investigated (0.01 × 10-3 - 10-3 M). Polarization curves (Tafel extrapolation) showed that both compounds act as mixed-type inhibitors in 1M HCl solutions. Electrochemical impedance spectra (Nyquist plots) are characterized by a capacitive loop observed at high frequencies, and another small inductive loop near low frequencies. The thermodynamic data of adsorption of the two compounds on the stainless steel surface and the activation energies were determined and then discussed. Analysis of experimental results shows that MDYO and DYCD inhibitors adsorb to the metal surface according to the Langmuir model and the mechanism of adsorption of both inhibitors involves physisorption. SEM-EDX results confirm the existence of an inhibitor protective film on the stainless steel surface. The results derived from theoretical calculations supported the experimental observation.

고속도로변 폐쇄회로 카메라 영상에서 트래킹에 의한 교통정보수집 알고리즘 (An Algorithm for Collecting Traffic Information by Vehicle Tracking Method from CCTV Camera Images on the Highway)

  • 이인정;민준영;장영상
    • Journal of Information Technology Applications and Management
    • /
    • 제11권4호
    • /
    • pp.169-179
    • /
    • 2004
  • There are many inductive loop detectors under the highways in Korea. Among the other detectors, some are image detectors. Almost all image detectors are focused one or two lane of the road and are measuring traffic information. This paper proposes to an algorithm for detecting traffic information automatically from CCTV camera images installed on the highway. The information which is counted in one lane or two contains some critical errors by occlusion frequently in case of passing larger vehicles. In this paper, we use a tracking algorithm in which the detection area include all lanes, then the traffic informations are collected from the vehicles individually using difference images in this detection area. This tracking algorithm is better than lane by lane detecting algorithm. The experiment have been conducted two different real road scenes for 20 minutes. For the experiments, the images are provided with CCTV camera which was installed at Kiheung Interchange upstream of Kyongbu highway, and video recording images at Chungkye Tunnel. For image processing, images captured by frame-grabber board 30 frames per second, 640${\times}$480 pixels resolution and 256 gray-levels to reduce the total amount of data to be Interpreted.

  • PDF

Flexible Voltage Support Control with Imbalance Mitigation Capability for Inverter-Based Distributed Generation Power Plants under Grid Faults

  • Wang, Yuewu;Yang, Ping;Xu, Zhirong
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1551-1564
    • /
    • 2016
  • The high penetration level of inverter-based distributed generation (DG) power plants is challenging the low-voltage ride-through requirements, especially under unbalanced voltage sags. Recently, a flexible injection of both positive- (PS) and negative-sequence (NS) reactive currents has been suggested for the next generation of grid codes. This can enhance the ancillary services for voltage support at the point of common coupling (PCC). In light of this, considering distant grid faults that occur in a mainly inductive grid, this paper proposes a complete voltage support control scheme for the interface inverters of medium or high-rated DG power plants. The first contribution is the development of a reactive current reference generator combining PS and NS, with a feature to increase the PS voltage and simultaneously decrease the NS voltage, to mitigate voltage imbalance. The second contribution is the design of a voltage support control loop with two flexible PCC voltage set points, which can ensure continuous operation within the limits required in grid codes. In addition, a current saturation strategy is also considered for deep voltage sags to avoid overcurrent protection. Finally, simulation and experimental results are presented to validate the effectiveness of the proposed control scheme.

Design Methodology of Passive Damped LCL Filter Using Current Controller for Grid-Connected Three-Phase Voltage-Source Inverters

  • Lee, Jun-Young;Cho, Young-Pyo;Kim, Ho-Sung;Jung, Jee-Hoon
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1178-1189
    • /
    • 2018
  • In grid-connected voltage-source inverters (VSIs), when compared with a simple inductive L filter, the LCL filter has a better performance in attenuating the high frequency harmonics caused by the pulse-width modulation of power switches. However, the resonance peaks generated by the filter inductors and capacitors can make a system unstable. In terms of simplicity and filter design cost, a passive damping method is generally preferred. However, its high power loss and degradation in high frequency harmonic attenuation are significant demerits. In this paper, a mathematical design solution for a passive LCL filter to derive filter parameters suppressing the high frequency current harmonics to 0.3% is proposed. The minimum filter inductance can be obtained to reduce the size of the filter. Furthermore, a minimum damping resistance design considering a current controller is analyzed for a stable closed-loop system. The proposed design method is verified by experimental results using a 5-kW three-phase prototype inverter.