Cause of Cavitation Instabilities in Three Dimensional Inducer

  • Kang, Dong-Hyuk;Yonezawa, Koichi;Horiguchi, Hironori;Kawata, Yutaka;Tsujimoto, Yoshinobu
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권3호
    • /
    • pp.206-214
    • /
    • 2009
  • Alternate blade cavitation, rotating cavitation and cavitation surge in rocket turbopump inducers were simulated by a three dimensional commercial CFD code. In order to clarify the cause of cavitation instabilities, the velocity disturbance caused by cavitation was obtained by subtracting the velocity vector under non-cavitating condition from that under cavitating condition. It was found that there exists a disturbance flow towards the trailing edge of the tip cavity. This flow has an axial flow component towards downstream which reduces the incidence angle to the next blade. It was found that all of the cavitation instabilities start to occur when this flow starts to interact with the leading edge of the next blade. The existence of the disturbance flow was validated by experiments.

터보펌프 인듀서의 흡입성능에 대한 직경과 회전속도의 영향 (The Effect of the Diameter and Rotational Velocity on the Cavitation Performance of a Turbopump Inducer)

  • 손동기;구현철;차봉준;양수석;이대성
    • 한국유체기계학회 논문집
    • /
    • 제5권1호
    • /
    • pp.27-32
    • /
    • 2002
  • The turbopump inducer cavitation is very important for the success of a liquid rocket engine. In this study, the performance test and cavitation performance test were carried out at various rotational speeds with two inducers of different diameter. The rotational speed was varied by 4000, 6000, and 8000 rpm, and the size effect was tested for the normal inducer and twice-enlarged one. The hydraulic performance results showed that the similarity was satisfied over the entire test range of the present study. The blade thickness effect was examined and showed that the increased blade thickness resulted in decreased efficiency and worse cavitation performance for the large tip clearance. The cavitation performance test results showed that the breakdown NPSH increased as the flow coefficient, and was not affected by the rotational speed.

터보펌프 인듀서의 흡입성능에 대한 직경과 회전속도의 영향 (The Effect of the Diameter and Rotational Velocity on the Cavitation Performance of a Turbopump Inducer)

  • 손동기;구현철;차봉준;양수석;이대성
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.229-234
    • /
    • 2001
  • The turbopump inducer cavitation is very important for the success of a Liquid rocket engine. In this study the performance test and cavitation performance test were carried out at various rotational speed with two different diameter inducers. The rotational speed were varied 4000, 6000, 8000 rpm and the variation to the diameter of an inducer were taken as design size and 2 times enlarged size. The major results of the present study were as follows. 1. The hydraulic performance results showed that the similarity was met over the entire test range of the present study. 2. The blade thickness effect was examined and showed that the increased blade thickness resulted in decreased efficiency and worse cavitation performance for large tip clearance. 3. The cavitation performance test results showed that the breakdown NPSH increases as the flow coefficient and does not affected by the rotational speed.

  • PDF

Cavitation Instabilities of Hydrofoils and Cascades

  • Tsujimoto, Yoshinobu;Watanabe, Satoshi;Horiguchi, Hironori
    • International Journal of Fluid Machinery and Systems
    • /
    • 제1권1호
    • /
    • pp.38-46
    • /
    • 2008
  • Studies on cavitation instabilities of hydrofoils and cascades are reviewed to obtain fundamental understandings of the instabilities observed in turbopump inducers. Most of them are based on the stability analysis of two-dimensional inviscid cavitating flow. The most important finding of the analysis is that the cavitation instabilities depend only on the mean cavity length. For a hydrofoil, the characteristic length is the chord length and partial/transitional cavity oscillation occurs with shorter/longer cavity than 75% of the chord length. For cascades, the characteristic length is the blade spacing and various modes of instabilities are predicted when the mean cavity is longer than 65% of the spacing. In the last part, rotating choke is shown to occur when the cavity becomes longer than the spacing.

The Cloning of MLS Antibiotics Inducible Resistance Gene

  • Choi, Eung-Chil;Woo, Kyung-Won;Kwak, Jong-Suk;Kim, Jin-Hwan;Byung-Kak
    • Archives of Pharmacal Research
    • /
    • 제12권3호
    • /
    • pp.176-180
    • /
    • 1989
  • Four bacterial strains having inducible resistance to erythromycin were isolated from soil samples in Korea and characterized. MLS inducibility was checked in each strain. Cloning of inducible resistance gene(s) has been tried. Four isolates were identified as B. anthracis, Micrococcus luteus, Streptococcus faecium and B. licheniformis, in which erythromycin, oleandomycin, cirramycin and carbomycin acted as resistance inducers respectively. The resistance gene cloned from B, licheniformis 597 strain using pBS 42 vector was found to have a 3.2 kb insert.

  • PDF

인듀서의 크기가 터보펌프의 흡입성능 상사에 미치는 영향에 관한 연구 (Put Effect of the inducer scale on the suction performance similarity of a turbopump)

  • 강병윤;강신형
    • 한국유체기계학회 논문집
    • /
    • 제17권4호
    • /
    • pp.47-52
    • /
    • 2014
  • An inducer is forward-attached to an impeller to improve the suction performance. This paper described the experimental and numerical investigations on the concept of NPSH similarity about the inducer scale. As Reynolds number decreased for the same scale inducer, the hydraulic performance is slightly reduced because of the viscosity. The suction performance similarity is in good agreement. For different scale inducers, the NPSH similarity did not follow the conventional rule which is proportional to the square of the inducer diameter. A cavity of two times scale inducer grows faster under cavitation inception, and the head is more drop as the fluid passes blades. Because of the simplified cavitation model and vapor pressure, the NPSH similarity dose not have an accuracy. This study suggested an empirical formula for the NPSH similarity.

Improvement of Amidase Production by a Newly Isolated Delftia tsuruhatensis ZJB-05174 Through Optimization of Culture Medium

  • Wang, Yuan-Shan;Xu, Jian-Miao;Zheng, Ren-Chao;Zheng, Yu-Guo;Shen, Yin-Chu
    • Journal of Microbiology and Biotechnology
    • /
    • 제18권12호
    • /
    • pp.1932-1937
    • /
    • 2008
  • The R-amidase production by a newly isolated strain of Delftia tsuruhatensis ZJB-05174 was optimized in this paper. Effects of factors such as carbon sources, nitrogen sources, and inducers on amidase production were investigated. The medium composition was optimized using central composite designs and response surface analysis. The optimal medium components for enhanced amidase production were found to be as follows: glucose, 8.23 g/l; yeast extract, 11.59 g/l; 2,2-(R,S)-dimethylcyclopropane carboxamide, 1.76 g/l; NaCl, 1 g/l; ${KH_2}{PO_4}$ 1 g/l; and ${K_2}{HPO_4}$ 1 g/l. A maximum enzyme production of 528.21 U/l was obtained under the optimized conditions, which was 4.7 times higher than that obtained under initial conditions.

Quinone reductase 유도활성 측정에 의한 약용식물의 항암활성 검색 (Induction of Quinone Reductase by Extracts of Traditional Medicinal Plants)

  • 김해홍;김동만;현창기
    • 생약학회지
    • /
    • 제32권2호통권125호
    • /
    • pp.168-174
    • /
    • 2001
  • Induction of phase II enzymes is a major mechanism of chemoprevention. The induction levels of quinone reductase (QR) activity in cultured murine hepatoma (Hepa 1c1c7) cells by 80%-methanol extracts of traditional medicinal plants were measured. Among the tested 81 plants, the extracts of Aralia continentalis, Magnolia obovata, and Viscum album were found to induce QR activities over 250%. The maximum induction levels obtained were 401.9%, 270.5%, and 301.8% by treatments of the extracts of A. continentalis $(318\;{\mu}g/ml)$, M. obovata $(53.8\;{\mu}g/ml)$ and V. album $(80.6\;{\mu}g/ml)$, respectively. These QR induction activities were more potent than those of the known QR inducers, t-butylhydroquinone (170.1%) and ${\beta}-naphthoflavone$ (320.0%).

  • PDF

The Cytotoxic Action of New Ag-Porphyrin as a Potential Chemotherapeutic Agent

  • Nelli, Babayan;Artak, Tovmasyan;Ani, Gevorkyan;Gennadi, Gasparyan;Rouben, Aroutiounian
    • 환경생물
    • /
    • 제26권2호
    • /
    • pp.115-120
    • /
    • 2008
  • Earlier we have described new water-soluble Ag- and Zn-derivatives of tetrachloride meso-tetra (4-N-oxiethylpyridyl) porphyrin (TOEtPyP) as potential anticancer drugs. In this work the effect of one of these metal porphyrins, TOEtPyP Ag, on the cell population kinetics was studied in vitro using morphological and biochemical techniques. The results suggested that TOEtPyP Ag action consisted in the simultaneous suppression of the cell growth and activation of the cell death. About 40% of the cells were shown to die via apoptotic pathway. So, the porphyrin studied may be attributed to inducers of both necrotic and apoptotic processes. The results obtained support our previous assertion that TOEtPyP Ag may be considered as a potential chemotherapeutic agent.

보조 인듀서가 터보펌프의 흡입성능에 미치는 영향 (Effect of a booster inducer on the suction performance of turbopumps)

  • 최창호;홍순삼;김진한
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.552-557
    • /
    • 2004
  • Effects of a booster inducer on the suction performance of turbopumps are investigated in this paper. To see the effect of the booster inducer, suction performance tests are conducted with and without the booster inducer for three turbopumps. It is shown that the booster inducer can enhance the suction performance of turbopumps when the tip clearance of the main inducers are relatively large. Numerical analysis are also carried out to see the effects of the booster inducer on the performance of the main inducer. The booster inducer is shown to increase the static pressure at the inlet of the main inducer and prevent growing of inlet back flows which are believed to have deleterious effects on the suction performance of the inducer.

  • PDF