• Title/Summary/Keyword: induced ground

Search Result 916, Processing Time 0.03 seconds

Application of Smart Isolation Platform for Microvibration Control of High-Tech Industry Facilities (첨단기술산업 시설물의 미진동제어를 위한 스마트 면진플랫폼의 적용)

  • Kim, Hyun-Su;Kang, Joo-Won;Kim, Young-Sik
    • Journal of Korean Association for Spatial Structures
    • /
    • v.14 no.2
    • /
    • pp.87-94
    • /
    • 2014
  • In this study, a smart isolation platform has been developed for control of microvibration of high-technology facilities, such as semi-conductor plants and TFT-LCD plants. Previously, microvibration control performance of a smart base isolation system has been investigated. This study compared microvibration control performance of a smart isolation platform with that of conventional base isolation and fixed base. For this purpose, train-induced ground acceleration is used for time history analysis. An MR damper was used to compose a smart isolation platform. A fuzzy logic controller was used as a control algorithm and it was optimized by a multi-objective genetic algorithm. Numerical analysis shows that a smart isolation platform can effectively control microvibration of a high-technology facility subjected to train-induced excitation compared with other models.

Environmental Effect Analysis of Electromagnetic Induction in Express Electric Railway (고속 전철구간에서의 전력유도 환경 영향 분석)

  • Lee, Sang-Mu;Choi, Mun-Hwan;Cho, Pyung-Dong
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.9 no.1
    • /
    • pp.19-23
    • /
    • 2010
  • The Electromagnetic Interference could occur due to power line on the telecommunication service. The Countermeasure is practised by legal law. Various affecting factors are described in the law. In this paper, an effect by pipeline especially in the ground, power feeding plant, and curved railway sector is analyzed as environmental factors which are not included in the law. By the practical measurement, it appears that the measured voltages on the spots with underground pipeline are grouped into lower voltage level, induced voltage tends to be high near power feeding plant, and also in the curved railway line. These analytical results can be meaningly considered in the application of countermeasure.

  • PDF

Analysis of the Magnetic Effect on the Tube Infrastructure for a Super Speed Tube Train

  • Lee, Hyung-Woo;Cho, Su-Yeon;Cho, Woo-Yeon;Lee, Ju;Kwon, Hyeok-Bin
    • International Journal of Railway
    • /
    • v.2 no.4
    • /
    • pp.170-174
    • /
    • 2009
  • Super speed tube train is introduced to increase the speed of ground transportation. The super speed tube train levitates magnetically and runs in a partial vacuum tube, which can reduce the air resistance significantly. However, the strong magnetic force enough to propel the massive train can affect to the tube infrastructure. In this paper, authors have analyzed the leakage flux patterns and induced eddy current on the tube by using 3-dimensional Finite Element Method. These effects are investigated, especially by varying the materials and diameters of the tube. From the simulation results, the aluminum tube with the diameter of 3[m] is needed to be concerned because the induced eddy current produces joule heat, raises the inside temperature of the tube, and might be able to lead to electro-chemical corrosion on the tube, consequently reduce the durability.

  • PDF

Vibronically Induced Two-Photon Transitions in Benzene

  • Chung, Gyu-Sung;Lee, Duck-Kwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.10 no.3
    • /
    • pp.298-302
    • /
    • 1989
  • The strengths of two-photon transitions from the ground state to excited vibronic states in benzene are calculated by using the CNDO/2-U wave functions. The role of vibronic coupling in two-photon absorption process is discussed. The $A_{1{\bar{g}}}-A_{2g}^+$ two-photon transitions, which are forbidden by the identity-forbidden selection rule in single frequency two-photon absorption, are too weak to be experimentally observed even when two photons of different energies are used. It is because the transitions are forbidden also by the pseudo-parity selection rule which are applicable for alternant hydrocarbons such as benzene. It is also shown that the vibronic coupling is not very effective in altering the pseudo-parity property of the electronic state. The strength of the vibronically induced two-photon absorption is strongly affected by the presence of an electronic state from which two-photon absorption can borrow the intensity. It is pointed out that the pseudo-parity selection rule may be violated in such cases.

Prediction of earthquake-induced crest settlement of embankment dams using gene expression programming

  • Evren, Seyrek;Sadettin, Topcu
    • Geomechanics and Engineering
    • /
    • v.31 no.6
    • /
    • pp.637-651
    • /
    • 2022
  • The seismic design of embankment dams requires more comprehensive studies to understand the behaviour of dams. Deformations primarily control this behaviour occur during or after earthquake loading. Dam failures and incidents show that the impacts of deformations should be reviewed for existing and new embankment dams. Overtopping erosion failure can occur if crest deformations exceed the freeboard at the time of the deformations. Therefore, crest settlement is one of the most critical deformations. This study developed empirical formulas using Gene Expression Programming (GEP) based on 88 cases. In the analyses, dam height (Hd), alluvium thickness (Ha), the magnitude-acceleration-factor (MAF) values developed based on earthquake magnitude (Mw) and peak ground acceleration (PGA) within this study have been chosen as variables. Results show that GEP models developed in the paper are remarkably robust and accessible tools to predict earthquake-induced crest settlement of embankment dams and perform superior to the existing formulation. Also, dam engineering professionals can use them practically because the variables of prediction equations are easily accessible after the earthquake.

Characteristic and Propagation of Railroad Vibration in Kyoungbu Line (경부선 철도진동의 특성과 영향범위)

  • 유승도;신동석;설증민;강대준;박준철;이재인
    • Journal of KSNVE
    • /
    • v.7 no.4
    • /
    • pp.597-604
    • /
    • 1997
  • Ground vibrations induced from railroad were measured to get the basic data that can be usde to prepare countermeasures for solving environmental vibration problems. Vibration levels were measured simultaneously at three points in double distances from railroad. These data were analuzed with the kinds of trains, media to understand the magnitudes and characteristics of distance attenuation of railroad vibrations.

  • PDF

Effect of Vibration From Railroad by Distance using Questionare (설문에 의한 철도 진동의 거리별 영향 조사)

  • 유승도;신동석;설증민
    • Journal of KSNVE
    • /
    • v.7 no.3
    • /
    • pp.419-426
    • /
    • 1997
  • The psychological, physiological, and material effects of ground vibrations induced from railroad were surveyed with the magnitudes of vibration sensing using questionnaire on residents living near railroad. These magnitude of vibration sensing and effects were compared as rate or percent total based on double distances from railraod. Also overall effects of railraod vibrations were compared with vibration levels measured or predicted. The about 70% of residents living within 40m from railroad sense railroad vibration, 15% of residents are influenced phychologically. But physilogical and material effects disappeared beyond 40m.

  • PDF

Environmental Test of Avionics Equipment for Lightning Indirect Effect (낙뢰 간접영향에 대한 항공전자장비의 환경시험)

  • Jeong, Duck-young;Yang, Hyun-duck
    • Journal of Aerospace System Engineering
    • /
    • v.7 no.2
    • /
    • pp.55-59
    • /
    • 2013
  • Before avionics equipment are installed in aircraft, several environmental tests such as temperature, vibration, lightning, fire etc. must be conducted. One of the environmental tests is to substantiate protection designs of lightning indirect effect. It can be showed through RTCA DO-160G, section22 "Lightning Induced Transient Susceptibility" test. An additional test of aircraft level is required as well after installation of avionics equipment.

Prediction of Propagation of DSbway-Induced Ground Vibration using the Vibration Management System (진동관리시스템에 의한 지하철 지반진동 전파예측)

  • Huh, Young;Yi, Seoung-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.308-313
    • /
    • 1997
  • PC용 VMS의 한계점을 극복하기 위해 UNIX-ARC/INFO를 사용하여 WORKSTATION에서 구동되는 UNIX용 VMS를 개발하였다. 본 논문에서는 개발된 VMS의 적용가능성을 판단하기 위해 서울시를 대상으로 VMS시스템을 구현하였으며, 일부지역에서는 지하철운행시의 지반진동전파 예측을 하여 실측치와 비교를 통해 그 사용성을 평가하였다.

  • PDF

A Comparative Study on Construction Method for a Large Underground Station under Pile Supported Bridge (모형실험을 이용한 교량하부 통과 구간 굴착공법 비교 연구)

  • Yoo, Chung-Sik;Chung, Eun-Mok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.4
    • /
    • pp.177-190
    • /
    • 2017
  • This paper presents the results of an experimental study on the effect of large underground station construction method under an existing pile supported bridge using reduced-scale model tests. A series of tests were conducted on design alternatives using 1g models for different design options for which tunnel structures were created considering the similitude law. Deformation fields obtained using the PIV analysis and LVDTs together with strains in tunnel structures were used to investigate the effect of the construction methods on the pile supported bridge. The results of the tests demonstrated that the pipe roof structure is more efficient in limiting the ground deformation as well as the settlement of bridge foundation than a 2-Arch tunnel. It is also shown that the PIV analysis can be effectively used in analyzing ground tunneling induced ground movement for cases in which a construction sequence governs ground movement.