주거용 태양열 하이브리드 이산화탄소 열펌프 시스템의 성능특성에 관한 해석적 연구 (Simulation Study on the Performance Characteristics in the Solar Hybrid R744 Heat Pump for Residential Applications)

  • 김원석;조홍현
    • 설비공학논문집
    • /
    • 제23권10호
    • /
    • pp.678-686
    • /
    • 2011
  • Simulation study on the operating characteristics in the solar hybrid R744 heat pump system for residential applications was carried out with heat pump operating temperature, outdoor temperature and solar radiation. As a result, collector operating time is decreased by 1.5 hours due to the increase of water temperature in the heat storage tank when the heat pump operating temperature rises. Heat pump operating time is reduced by 19.4% owing to the high temperature of a heat storage tank. Besides, indoor heating time is decreased from 10.3 to 5.5 hours as the indoor temperature increases from $3^{\circ}C$ to $11^{\circ}C$. In addition to, when the solar radiation rises from 10 to 20 MJ/$m^2$, the maximum outlet temperature of a solar collector is increased from $65^{\circ}C$ to $71^{\circ}C$.

초고속통신망을 위한 구내통신 설로설비의 브릿지 탭의 문제점과 개선 방안 (Issues and Improvement Methods of the Bridge Tab in Customer Premises Telecommunications Facilities for High-Speed Communication Network)

  • 민경주;홍재환;남상식;김정호
    • 정보처리학회논문지C
    • /
    • 제13C권7호
    • /
    • pp.881-888
    • /
    • 2006
  • 기존 공동주택의 구내통신 선로설비 중의 댁내배선은 대부분 버스 배선 형태의 구조로 아웃렛의 위치에 따라 브릿지 탭(Bridged Tap)이 존재하게 된다. 이 브릿지 탭은 높은 주파수 대역을 사용하는 고속멀티미디어 통신의 특정 주파수에서 반사손실의 특성이 저하되어 선로의 감쇠가 급격히 증가하여 전송성능을 저하시키고 있어 이에 대한 분석이 필요하다. 본 논문에서는 기존 주거용 공동주택의 대표적인 아파트의 구내선로 구조 및 댁내 배선환경을 파악하고, 현업의 구내통신설비를 모델링하여 시험모형을 제작하여 VDSL 서비스 성능을 측정하였다. VDSL 서비스 시 브릿지 탭에 의해 성능에 미치는 영향을 분석하여, 기존 구내통신 선로의 문제점을 파악하고, 향후 초고속 멀티미디어 서비스 수용에 적합한 구내통신 선로의 품질개선 방안을 제시하였다.

강제환기를 이용한 하절기 군 저장시설의 표면결로 방지에 관한 연구 (Forced Ventilation Method for Preventing Surface Condensation of Magazine of Igloo type in Summer)

  • 박선효;윤성도;손장열
    • KIEAE Journal
    • /
    • 제10권2호
    • /
    • pp.57-62
    • /
    • 2010
  • In case of earth-covered storage, the condensation occurs on surface of wall and stores in summer with high humidity because of low temperature of constructional mass. Therefore, the preventive plans should be considered to protect stores from the damage by corrosion in earth-covered storages. This study aims to suggest the methods of forced ventilation by the air, to solve the problems of construction's surface condensation at the Magazine of igloo type which is similar to earth-covered storages. A fan was installed at the air outlet for exhaust gas to conduct forced ventilation. The surface and indoor temperature were measured, and then the influence of those on condensation was analyzed. The results of this research are follows; 1) Forced ventilation by a fan affects the rise in surface temperature of walls and stores. 2) The condensation on surface of walls and stores was reduced after operating a fan.

부식된 철근을 사용한 모르타르의 환경에 따른 부식전위의 거동 (The behavior of corrosion potential in the mortar-embedded)

  • 이상호;한정섭;권순석
    • 한국해양공학회지
    • /
    • 제10권4호
    • /
    • pp.103-108
    • /
    • 1996
  • To syudy the change of prtential in the mortar-embedded precorroded rebar, a half cell method was adapted. The rebar was corroded by the salt spray and then the rebar embedded in the mortar. A saturated copper sulfate feference electrode was used. The corrosion potential of the rebar in the mortar specimen cured in air was increased, whereas that of the rebar cured in water was decreased with aging. The corrosion potential of the rebar in the mortar was decreased with corroded time by the salt spray. As the mortar thickness covered the rebar was increased, the corrosion potential of the rebar in the mortar was increased.

  • PDF

대학교 기숙사의 실내공기질 환경 개선에 관한 연구 (A Study on Environmental Improvement of Indoor Air Quality in University Dormitory)

  • 김호진;양정훈;석호태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1398-1405
    • /
    • 2008
  • As the structure, material and construction of building develop continuously, so the recent residential buildings are being large, high-rise and group. High-rise residential buildings consume a lot of energy on supplying cold and hot water. As well, high-rise residential buildings bring on discomfortable use and unexpected conditions on account of faucet outlet pressure rise and the difference of water supply pressure between top floor and bottom floor. Thus, the purpose of this study is to research on using conditions of cold and hot water supply system through survey and field measurement in high-rise residential buildings and to analyze problems.

  • PDF

실내 오염물질의 희석환기에관한 모델링 (Modelling for Dilution Ventilation of Indoor Contamination Materials)

  • 심성훈;조상준;김광영
    • 한국기계연구소 소보
    • /
    • 통권19호
    • /
    • pp.31-42
    • /
    • 1989
  • To investigate design factors of dilution ventilation system, numerical analysis of air contamination flow and concentration distribution have been made, by using the low Reynolds number turbulent model. And flow visualization and measurement of particle concentration for that model also have been made. By comparing of these results we have secured the essential data for the adequate counterplan of dilution ventilation system. The results of this study are as follows: 1) Inlet should be located near the wall for the prevention of the formation of the recircula¬tion zone. 2) In case of natural exhaust, air contamination flow is driven to the far outlet from the inlet. 3) It is favorable for dilution to make turbuence as much as possible.

  • PDF

공기조화기 장착용 축상유입식 싸이클론의 입자제거효율에 대한 실험적 연구 (Experimental Study on Particle Collection Efficiency of Axial-flow Cyclone in Air Handling Unit)

  • 김세영;권순박;박덕신;조영민;김진호;김명준;김태성
    • 한국대기환경학회지
    • /
    • 제27권3호
    • /
    • pp.272-280
    • /
    • 2011
  • A novel particle removal system for air handling unit (AHU) of subway station was evaluated experimentally. The novel system was designed in order to minimize the maintenance cost by applying axial-flow cyclones. The system consists of multiple cyclone units and dust trap. Based on our previous numerical study, it was found to be effective for removal $1\sim10{\mu}m$ sized dust particles. In this study, we manufactured the mock-up model and evaluated the model experimentally. Liquid and solid test particles were generated for evaluating collection efficiency of the system and the pressure drop was monitored. The collection efficiency was varied from 41.2% to 85.9% with increasing the sizes of particle from 1 to $6.5{\mu}m$ by particle count ratio of inlet and outlet. The pressure drop was maintained constant less than $20mmH_2O$. In addition, the collection efficiency was estimated by total mass for solid test particles. It was found that the collection efficiency was 65.7% by particle mass ratio of inlet and outlet. It shows that present system can replace current pre-filters used in subway HVAC system for removing particulate matters with minimal operational cost.

빌딩 地下商街의 空氣性狀 및 분자의 變異原性 (Air Contamination in an Underground Commercial Floor assayed by GAseous Pollutants, Dusts and Mutagenicity)

  • 兪榮植
    • 한국대기환경학회지
    • /
    • 제3권2호
    • /
    • pp.46-52
    • /
    • 1987
  • There are many factors such as airtighteness and high density of merchandises or passengers that contaminate indoor air in underground commercial floor. So it is very important to know air quality and quantity of contamination in underground market increasing in number lately. It was from these viewpoints that gaseous pollutants, dusts and mutagenicity of organic compounds extracted from dusts in an underground market were investigatd. Organic ompounds (tar) were extracted by Soxhlet extractor with benzene as a solvent. Mutagenicities of these extracts were evaluated by the preincubation method using Salmonella typhimurium TA 100 and TA 98 strains with and without S9mix. The results obtained were as follows: It seemed to be under the influence of outdoor air that the concentrations of $CO, CO_2, NO, NO_2$ and dusts were higher in winter than summer. The concentration of $CO_2$ was higher in indoor than outdoor, but the concentration of NOx was similar in both sampling areas. Metal contents in dusts attached to the ventilation ducts were as follows showing in order of high concentration : Fe (9000-22000ppm), Zn(1200-2300ppm) and Pb (280-590ppm). The contents of tar were 6-33% of dusts, and higher than those from dusts collected by high volume air sampler. The extracts from dusts attached to the inlet duct exhibited lower mutagenicity than those from dusts attached to the outlet duct. This finding seemed to suggest that mutagenic substances were in creasing in underground. There was no seasonal difference of mutagenicity toward TA 98. Toward TA 100 in the presence of S9mix, the mutagenicity was about 3 fold higher in winter than summer. The mutagenicities of tar extracted from dusts collected by high volume air sampler were different from those attached to the ventilation ducts. The former showed 2-3 fold higher mutagenicity than the latter toward TA 100. However no difference showed between the former and the latter toward TA 98 in the absence of S9mix, but the former was 4-5 fold higher than the latter in the presence of S9mix.

  • PDF

예인 음탐기 콘솔의 냉각 배출 홴 소음 저감을 위한 소음기 개발 (Development of the Silencer for Reducing Noise from the Exhaust Cooling Fan of the TASS Console)

  • 한형석;박미유;조흥기;김중길;임동빈;손윤준
    • 한국소음진동공학회논문집
    • /
    • 제20권12호
    • /
    • pp.1139-1146
    • /
    • 2010
  • The indoor noise of the naval vessel is very important related to the optimum environmental conditions for crews as well as the ability of fighting power of antisubmarine. Especially, sonar equipment room is one of the rooms where require to be silent because the informations of the underwater noise are collected and analyzed in there. In this paper, the sound reduction of the TASS console, one of the main noise sources in a sonar equipment room for a typical naval vessel, is described. The noise source of this TASS console is the flowing noise of cooling fan. In order to reduce this kind of noise, the plenum chamber and acoustic elbow were developed. Related to the development of the plenum chamber, the area of the air-outlet and sound absorption of the inner lining were investigated experimentally with the evaluation system of the sound insertion loss. Acoustic elbow was also manufactured and evaluated with the evaluation system of the sound insertion loss. Finally, in order to evaluated the ability of noise reduction of the plenum chamber and acoustic elbow, the indoor noise of the sonar equipment was measured when they were appled to TASS console.

CFD 해석을 통한 후지 사과 CA 저장고 내의 적정 CO2 농도 조성 검토 (Evaluating Proper CO2 Concentrations in CA Storage of Fuji Apple using CFD Analysis)

  • 이상익;홍세운;최원;김락우;이인복
    • 한국농공학회논문집
    • /
    • 제60권3호
    • /
    • pp.71-81
    • /
    • 2018
  • $CO_2$ concentration has a significant effect on quality of cold-stored apples. High indoor $CO_2$ concentrations above 10,000 ppm cause the browning of apples and result in economic loss for farmers. The purpose of this study is to evaluate $CO_2$ concentrations and their distribution in a controlled atmosphere (CA) storage and provide better structural designs to improve the $CO_2$ environment using computational fluid dynamics (CFD) simulations. The CFD model was developed for a real CA storage for apples and applied to investigate the effect of changing the inlet and outlet locations and the aspect ratio of the floor of the CA storage on the spatial distributions of $CO_2$ concentration and the browning of the apples. The lowest $CO_2$ concentrations in existing CA storage with a high aspect ratio of the floor were achieved from the combination of the inlet located at the top of the right side and the outlet located at the bottom of the left side. In modified CA storage with a low aspect ratio, the combination of the inlet and outlet located at top and bottom of left side respectively achieved the lowest $CO_2$ concentrations. The proposed case enhanced the storage performance by reducing total browned apples by 3.6% in storage duration of 210 days. This study is expected to reduce the browning damages of apples in CA storage, and thus greatly prevent economic losses.