A Study on Predication model for TVOC Emissions of Finishing material in Apartment House (공동주택 건축내장재의 TVOC 방출량에 관한 예측모델 연구)

  • Kim, Hyung-Soo;Lee, Kyung-Hoi
    • KIEAE Journal
    • /
    • v.2 no.3
    • /
    • pp.55-62
    • /
    • 2002
  • While cognition about an environment pollution becomes important recently, the intense pollution measures about an indoor air environment is required. In the case of building indoor environment, over 80% of modem people is living in building and these days an interest of building interior materials which becomes a reason for indoor environmental pollution in public house, office, is increasing. An experimental measurement method of this study is as follows. (1) American EPA TO-17, ASTMD5116-97, measurement method in VOCs experiment of Japanese closet industrial association (2) 2.4-DNPH cartridge method in HCHO experiment, based on American EPA TO-11 and measurement method of Japanese closet industrial association (3) standard compound is analyzed by using HPLC after solvent extraction process (4) paint and furniture are selected as measurement objects (5) we also made small chamber to grasp an emission characteristic of HCHO and VOCs and to get an environment-amicable forecast model through it, then we developed the model which can forecast emission rate by chamber experiment.

Indoor and outdoor pullout tests for retrofit anchors in low strength concrete

  • Cavunt, Derya;Cavunt, Yavuz S.;Ilki, Alper
    • Computers and Concrete
    • /
    • v.18 no.5
    • /
    • pp.951-968
    • /
    • 2016
  • In this study, pullout capacities of post-installed deformed bars anchored in low strength concrete using different bonding materials are investigated experimentally. The experimental study was conducted under outdoor and indoor conditions; on the beams of an actual reinforced concrete building and on concrete bases constructed at Istanbul Technical University (ITU). Ready-mixed cement based anchorage mortar with modified polymers (M1), ordinary cement with modified polymer admixture (M2), and epoxy based anchorage mortar with two components (E) were used as bonding material. Furthermore, test results are compared with the predictions of current analytical models. Findings of the study showed that properly designed cement based mortars can be efficiently used for anchoring deformed bars in low quality concrete. It is important to note that the cost of cement based mortar is much lower with respect to conventional epoxy based anchorage materials.

Measurement and Comparative Analysis of Propagation Characteristics in 3, 6, 10, and 17 GHz in Two Different Indoor Corridors (두 가지 서로 다른 실내 복도에서 3, 6, 10, 17 GHz의 전파 특성 측정 및 비교 분석)

  • Seong-Hun Lee;Byung-Lok Cho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.6
    • /
    • pp.1031-1040
    • /
    • 2023
  • Propagation characteristics in line-of-sight(LOS) paths in 3, 6, 10, and 17 GHz frequency bands were measured and analyzed in two different indoor corridors: second floors of Buildings D2 and E2. The measurement was designed to measure when the receiving antenna moved at 0.5 m intervals from 3 m to 30 m, while the transmission antenna was fixed. The analysis of the two indoor corridors was compared by applying basic transmission loss, root mean square (RMS) delay spread, and K-factor. For basic transmission loss, the loss coefficient of the floating intercept path loss model was higher in the indoor corridor of Building E2 than in that of Building D2. Similarly, the RMS delay spread in the time domain was greater in the indoor corridor of Building E2. However, the indoor corridor of Building D2 exhibited higher K-factor in the 3, 6, and 17 GHz bands with lower wave propagation in the 10 GHz band. Despite the 2 indoor corridors being identical, the propagation characteristics varied due to different internal structures and materials. The results provide measurement data for ITU-R Recommendations regarding various indoor environments.

Analysis of Hygrothermal Performance of Wood Frame Walls according to Position of Insulation and Climate Conditions

  • Kang, Yujin;Chang, Seong Jin;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.2
    • /
    • pp.264-273
    • /
    • 2016
  • The insulation of a building envelope influences the hygrothermal performance as well as the thermal performance of the building. While most of Korean wood frame houses have an interior insulation system, the exterior insulation system with high thermal performance has recently been applied. While it can be effective in energy savings for better insulation performance, without consideration of the moisture, condensation and mould growth can occur. Therefore, in this study, hygrothermal behaviour, water content, and mould growth were analyzed using hygrothermal simulation of an exterior wall of a wood frame house with which the interior insulation and exterior insulation systems were applied. The wall layer included Wall A (Interior insulation) and Wall B (Exterior insulation). The U-values were identified as 0.173 and $0.157W/m^2K$, respectively. The total water content and OSB absolute water content of Wall A were confirmed to be higher than those of Wall B, but the absolute water content did not exceed the reference value of 20%. The moisture content of the two walls was determined to be stable in the selected areas. However, mould growth risk analysis confirmed that both Wall A and Wall B were at risk of mould growth. It was confirmed that as the indoor setting temperature decreased, the mould index and growth rate in the same area increased. Therefore, the mould growth risk was affected more by indoor and outdoor climate conditions than by the position of the insulation. Consequently, the thermal performance of Wall B was superior to that of Wall A but the hygrothermal performances were confirmed to be similar.

Comparative Evaluation of Condensation by Type and Layer Around Built-in Furniture of Apartment Buildings (WUFI를 이용한 공동주택 붙박이가구의 층별·형태별 결로 생성 비교 평가)

  • Yoo, Jiwon;Chang, Seong Jin;Lee, Jongki;Wi, Seunghwan;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.29 no.1
    • /
    • pp.31-39
    • /
    • 2018
  • Recently, as the continuously increasing of the one-person households, builders were focusing on a built-in furniture development for efficiency. Through the dead space of the space can be reduced. Also, Condensation that occurs in a built-in furnitures installation space may result in different results depending on the room's direction, floor, finish, adjacent room effect, occupant's lifestyle. In this background, it can be considered in terms of functional aspect and morphological aspect by using WUFI2D simulation system. As a result, the tendency of occurrence of condensation was examined by comparing the water content and the growth potential of fungus graph which came from WUFI2D. Results of this study are as followings: Built-in furniture, both top & bottom open, is more stable to condensation than the built-in furniture with the top or bottom open. Also, Among from the top floor built-in furniture to the bottom of it, the bottom one is more stable to condensation.

  • PDF

Impact of Indoor Air Quality on the Eye Conditions of Occupants in Newly-built University Buildings (새 학교 건물 내 실내공기질이 재실자의 안구에 미치는 영향)

  • Kim, Woo-Jae;Kim, Sun-Duk;Kim, Hyojin;Kim, Ho-Hyun;Lee, Cheol-Min;Kim, Yoon-Shin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.201-207
    • /
    • 2011
  • Purpose: This study was to find out the influence on eyes of indoor air quality in college students taking course, such as Sick-building syndrome symptoms and effects on the eye in new-built university buildings. Methods: We selected a new building in a university located in Metro Seoul and college students in a department for the study. The number of total participants was 33, to whom questionnaire surveys were conducted in advance to check individual traits (gender, age, whether to smoke, whether to wear contact lenses, or whether to drink). The first questionnaire surveys and checking of ocular symptoms to first indoor hazardous materials were conducted in October and two months later the second surveys and checking were carried out in December. The indoor air quality was measured when conducting the first questionnaire surveys and the second questionnaire surveys; especially measurements of gaseous materials such as aldehydes and VOCs in the indoor air were conducted. Results: Indoor air quality of the new building was as follows: formaldehyde level was 22.90 ${\mu}g/m^3$ in the first measurement and 16.79 ${\mu}g/m^3$ in the second measurement. In addition, most materials showed higher value in the first measurement. The level of TVOC was statistically significant (p<0.05) decreased on 448.54 ${\mu}g/m^3$ in the first and 62.55 ${\mu}g/m^3$ in the second. In clinical assessments to check ocular symptoms caused by eye irritations, dry eye syndrome was found in the first and second exposures. When comparing the first and second assessments, dry eyes deteriorated in the morning of the second attempt compared to the first one. Conclusions: In the survey of ocular symptoms and the measurement of indoor air quality, the level of formaldehyde was measured higher in the second attempt than the first; thus, it was confirmed the influence of indoor air quality in a new building upon ocular symptoms of occupants.

The Analysis of VOCs by GC/MS with Whole Column Coldtrapping on a Fused Silica Capillary Column in Indoor Environment

  • Dai, Shugui;Zhang, Lin;Bai, Zhipeng
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.829-834
    • /
    • 1995
  • Whole column coldtrapping(WCC) on a fused silica capillary (FSCC)combined with GC/MS analysis was evaluated for use in the investigation of volatile organic compounds(VOCs) in indoor air. Research had indicated that a temperature of $-80^{\circ}C$ is optimal for WCC. Samples were analyzed on a $50m{\times}0.2mm$ cross-linked 5% phenylmethylsilicone fused silica column. Liquid nitrogen was used as the coolant for the peak resolution significantly. The analysis can be performed quickly and conveniently. More than 112 of VOCs were determined in the samples from three typical indoor environment including: (1) a room which had just been decorated involving building materials and paints; (2)a kitchen used for Chinese cooking, and (3) a room had tobacco smoke. The method is could be readily applied to rapid sample screening for VOCs contamination surveys or initial investigations with its valid and simple sampling and analytical technique.

  • PDF

The Impact of Bake-Out Method on the Reduction of Pollutant Concentration in New Apartments (Bake-Out에 의한 신축 아파트의 실내 오염물질농도 저감효과 평가)

  • Pang Seung-Ki;Park Byung-Yoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.4
    • /
    • pp.335-343
    • /
    • 2006
  • Indoor air pollution has been significantly aggravated due to hazardous pollutants emitted from petrochemical finishing materials in new apartments. Pollutants emitted into indoor environment have significant effects on the health of occupants, causing undesirable symptoms related to sick building syndrome such as headache, dizziness, difficulty in concentration, etc. Therefore, this paper attempted to investigate the reduction effect of bake out on VOCs emission in new apartments. Experiments were carried out in three households, one of which was naturally ventilated. The naturally ventilated showed the lowest indoor pollutant concentration and also showed the highest reduction rate by the use of bake out. The most desirable result was observed when the household was naturally ventilated after bake out. More detailed experiments are expected to be carried out afterwards on the prediction of reduction rate of each pollutant.

Properties of lightweight matrix for inorganic insulation by cement types (시멘트 종류별 무기단열재용 경량 경화체의 특성)

  • Lim, Jeong-Jun;Pyeon, Su-Jeong;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.222-223
    • /
    • 2018
  • Recent government policies are increasing interest in zero-energy housing, a building that minimizes energy consumption (90% reduction). As the importance of building passive performance is emphasized, the role of insulation is increasing as a way to reduce indoor heat loss in order to minimize the use of cooling and heating energy. There are two main types of insulation. Organic insulation is widely used for various construction structures such as construction and industrial due to some merits such as the convenience of construction and construction cost. However, it has been pointed out as a main cause every time a fire accident occurs, Jecheon Sports Center', the fire damage of buildings caused by the use of organic insulation materials is expanding to social problems, so it is urgent to research on nonflammable inorganic insulation materials.

  • PDF

Indoor Radon Levels and Effective Dose Estimation in Learning and Common Living Space of University (대학 내 학습공간과 공동 생활공간에 대한 실내 라돈 농도 측정과 유효선량 산출)

  • Kim, Jung-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.329-334
    • /
    • 2018
  • Radon which is natural component of air is a colorless and odorless radioactive gas. Radon exposure can also occur from some building materials if they are made from radon-containing substances by breathing. In this study, The radiation dose of radon concentration was detected at 8 buildings of the A university during 3-month from June. 2017 to August. 2017. We detected indoor radon exposure at 8 building of the university and estimated annual effective dose. The radon concentration of Hall G and Hall F of the A university represented 81 and $14Bq/m^3$ respectively and average indoor radon concentration represented $41.63Bq/m^3$. Average effective dose was estimated 0.40 mSv/y, maximum effective dose was 0.78 mSv/y and minimum effective dose was 0.13 mSv/y respectively. University is the place that students spend the almost whole time. We suggest ventilation and appropriate management of a building, which could reduce the natural radiation exposure by radon concentration.