• Title/Summary/Keyword: indoor air environment

Search Result 1,063, Processing Time 0.026 seconds

Measurement of Indoor Air Quality in a Kindergarten (유치원내 실내공기환경 측정)

  • Kim, Yun-Deok;Lim, Soo-Young
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.14 no.1
    • /
    • pp.52-57
    • /
    • 2007
  • Kindergarten children are engaged in the age of physical immaturity as well as the rapid growth. The indoor air contaminants that are proved to affect even the full grown adults are obvious to have no little influence to immature small children in a growth period. In May 2004, for the multi purpose facilities and newly constructed apartments, the Ministry of Environment announced "Indoor Air Quality Control Law for the Multi Purpose Facility," which made the interests to be focused in the urgent understanding of current condition and preparation of measures about the indoor air pollution. In Dec 2005, the law was revised to obligatorily notify the amount of Formaldehyde and Volatile Organic Compounds in the case of newly constructed apartments with more than 100 houses. However, since the kindergarten takes none of the classifications, even the current condition is not grasped although it is directly connected to the health of growing children. Therefore, the study aims to analyze indoor air pollution of one selected kindergarten in Incheon city.

A Study on the Characteristics of Heavy Metal Concentration and Indoor Atmospheric Environments ; Heavy Metal Concentration in School Environments (실내 대기환경과 중금속농도의 분포특성에 관한 연구 - 학교 환경의 중금속농도)

  • 박종길;장난심
    • Journal of Environmental Science International
    • /
    • v.6 no.5
    • /
    • pp.451-459
    • /
    • 1997
  • This paper alms to describe the indoor-outdoor air quality in school environment through the analyses of heavy metal concentration by inductively Coupled Plasma(ICPI, which were observed at some school environment, such as traffic area, industrial area seme-industrial area, and residence area. The results are as follows : (1) Regardless Indoor and outdoor, the area with the highest concentration of heavy metal is industrial area followed by traffic area, residence area and semi-industrial area in descending order of magnitude. And the heavy metal concentration of indoor is higher than that of outdoor. (2) The main heavy metal components with more high level concentration of Indoor than those of outdoor are Zn, Al, Ca and these heavy metal concentrations are higher in class than In corridor and outdoor.

  • PDF

A study on the construction technology for major building material to reduce indoor air pollution (실내오염물질방출저감을 위한 주요건축자재의 시공기술에 관한 연구)

  • Heo, Jung-Yong;Choi, Chang-Ho;Ann, Hyung-June;Lee, Yun-Gyu
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.143-148
    • /
    • 2007
  • Recently indoor air pollution caused by exposing hazardous chemicals (VOCs, formaldehyde) due to undiscriminated use of new construction materials and air-tightness to save energy is becoming a big issue. We have developed technologies to estimate the amounts of contaminants from constructions materials and method. We have further developed construction technologies to reduce and characterize these contaminants. The developed technologies were then refined to eliminate defects through considering field applicability.

  • PDF

A Numerical Investigation of Indoor Air Quality with CFD

  • Sin V. K;Sun H. I
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.207-208
    • /
    • 2003
  • Increasing interest in indoor air quality (IAQ) control has been found because of its serious effect on human health. To evaluate IAQ, thermal comfort in terms of temperature and velocity distributions of indoor air has to be analyzed in detail. Choice of location for installation of air-conditioner in a building will affect the performance of cooling effect and thermal comfort on the occupants, which in turn will affect the indoor air quality (IAQ) of the building. In this paper, we present a discussion on the proper location of the air-conditioner in order to obtain good thermal comfort for occupant of a typical bedroom in Macao. A set of carefully designed numerical experiments is run with the Computational Fluid Dynamics (CFD) software FLOVENT 3.2 [1]. Reynolds averaged Navier-Stokes equations are solved with finite volume technique and turbulence effects upon the mean flow characteristics is modeled with the k - & model. Assumption of steady state environment is made and only convective and conductive heat transfer from the occupant and air-conditioner are being concerned.

  • PDF

A study on university office worker's perception of indoor air quality (Focused on K university) (사무실 근로자들의 실내공기질 인식에 관한 기초 조사 (K대학교를 중심으로))

  • Shin, Eun-Young;Kim, Gwang-Hee
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.16 no.3
    • /
    • pp.69-76
    • /
    • 2017
  • Indoor Air Quality(IAQ) affects physical and mental state of person who is residing indoor. Also, it manages daily life condition of Indoor Air in the building. According to the study, office workers spend 23 hours and 12 minutes, about 97% of his/her day indoor. Therefore, Indoor air quality affects not only the health of the person whose staying inside for a long hours but also the productivity and efficiency of work. This study conduct investigations on employees' awareness of indoor air quality of office in university. By doing so, we are able to determine current situation and provide basic data of improvement for derived problems. As a result, most of the respondents were not satisfied with ventilation and moisture which are elements of Indoor Air Quality. These led people to struggle with symptoms of health. Therefore, to improve the indoor air quality of a university office, it is necessary to exchange the air six times an hour according to recommendation of Refrigeration and Air Conditioning Engineers (ASHRAE)in the United States. Also, plan for Ventilation system that consider temperature, humidity and air flow indoor shall be provided for high quality conformability. furthermore, It is necessary to consider the multilateral in factors of generation of revenue through health care savings of workers and improvement of productivity.

An Exploratory Research on Social Workers' Attitude and Related Factors about Indoor Air Quality Management of Social Welfare Facilities (사회복지시설 종사자의 실내공기질 관리에 대한 태도와 관련 요인에 관한 탐색적 연구)

  • Bae, Jin-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.5
    • /
    • pp.273-284
    • /
    • 2017
  • As these days people spend most of time at inner space, indoor air quality affect human life seriously. Government manage indoor air quality of various facilities based on different laws. Government released that they would try to protect environment for vulnerable people such children and seniors from indoor air pollutants in 2015. But social welfare facilities are exception under current legal systems. Clients of social welfare residential facilities are the disables, the elderly, homeless and children and they usually stay inner space very long time. The purpose of this study is explore workers' attitude and related factors about indoor air quality management of social welfare facilities. 69.5% of respondents agree to government's indoor air quality management, 80.9% of respondents think social welfare facilities must be included in legal system for indoor air quality management. Environmental awareness and law awareness were related with attitude to indoor air quality management. Based on the results of the analysis, I propose the amendment of law on indoor air quality of the Ministry of Environment, cost burden of central or local government and the necessity of education and research on indoor air quality management in social welfare facilities.

Efficiency of Removal for Indoor air pollutants by Air Cleaners in the Indoor Environments (공기청정기의 일부 실내공기 오염물질 제거효율에 관한 연구)

  • Lee Tae-Hyung;Kim Yoon-Shin;Hong Seung-Cheol;Lee Cheol-Min;Kim Jong-Cheol;Jeon Hyung-Jin;Kim Jung-Ho
    • Journal of Environmental Science International
    • /
    • v.14 no.5
    • /
    • pp.491-497
    • /
    • 2005
  • In this study, we investigated $PM_{10},\;NO_2$, and l-hydroxypyrene(1-OHP) in urine at indoor environments which are 35 houses and 20 hospitals for using air cleaner and non-using air cleaner in Seoul metropolitan area and Kyoung-gi province from April, 2003 to February, 2004. Moreover, we examined effect of improvement for indoor air quality and health effect by concentration of 1-OHP also we investigated removal efficiency by air cleaner for $PM_{10},\;NO_2$, and 1-OHP that were 28.5\%,\;27.4\%,\;and\;42.1\%$ respectively. Concentration of$PM_{10},\;NO_2$, and 1-OHP were $19.02\pm18.14{\mu}g/m^3,\;8.66\pm3.06ppb,\;and\;0.19\pm0.18{\mu}g/g$, creatinine when air cleaner was no worked. The concentration for $PM_{10},\;NO_2$. and 1-OHP were $13.60\pm10.79{\mu}g/m^3,\; 6.29\pm2.71ppb,\;and\;0.11\pm0.10{\mu}g/g$ creatinine, respectively. It was significant statistically. Therefore, it is considered using the air cleaner to remove the partial pollutants in indoor environment and is positive effect for health.

Box Model Approach for Indoor Air Quality (IAQ) Management in a Subway Station Environment

  • Song, Jihan;Pokhrel, Rajib;Lee, Heekwan;Kim, Shin-Do
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.4
    • /
    • pp.184-191
    • /
    • 2014
  • Air quality in a subway tunnel has been crucial in most of the subway environments where IAQ could be affected by many factors such as the number of passengers, the amount and types of ventilation, train operation factors and other facilities. A modeling approach has been introduced to manage the general IAQ in a subway station. Field surveys and $CO_2$ measurements were initially conducted to analyze and understand the relationship between indoor and outdoor air quality while considering internal pollution sources, such as passengers and subway trains, etc. The measurement data were then employed for the model development with other statistical information. For the model development, the algorithm of simple continuity was set up and applied to model the subway IAQ concerned, while considering the major air transport through staircases and tunnels. Monitored $CO_2$ concentration on the concourse and platform were correlated with modeling results where the correlation values for the concourse and platform were $R^2=0.96$ and $R^2=0.75$, respectively. It implies that the box modeling approach introduced in this study would be beneficial to predict and control the indoor air quality in subway environments.

Health effects on workers and actual exposure of VOCs in the nail shops (네일샵 종사자의 휘발성유기화합물 노출실태와 건강에 미치는 영향)

  • Kim, Nan-Hee;Min, Kyoung-Woo;Cho, Gwang-Woon;Seo, Dong-Ju;Im, Kyeong-Hun;Jeung, Won-Sam;Cho, Young-Gwan;Yang, Jin-Seok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.1
    • /
    • pp.59-69
    • /
    • 2017
  • Objectives: The objective of this study is to evaluate the exposure of VOCs and effects of the chemicals on the nail technicians whose works in a nail shop. Methods: For four month from May to August in 2016, we measured twenty-two kinds of VOCs in ten nail shops and carried out health examinations on thirty-four workers in there. Results: The TVOC concentration in indoor air of nail shops is $0.487mg/m^3$ at a minimum and $33.236mg/m^3$ at a maximum where it consists of 70.5% of Ketones, 25.4% of Alcohols, 2.6% of Esters, 0.8% of Aldehydes and 0.7% of Aromatics. The VOCs concentration during nail art works shows an increase in average ratio 1.8 compared to the concentration of indoor air quality and also the concentration of Isopropanol rose with 3.2 of the highest ratio. The results of Spearman correlation between TVOC concentration in indoor air and environmental factor was like that has significance level of correlation(${\rho}$<0.05, r=0.682) in case of number of customers per day, but the other factors were not meaningful in correlation. Correlation between VOCs and medical check-up items was like that has positive significance level(${\rho}$<0.01, r=0.638) between isopropanol and GPT, but the others have not meaningful. The exposure level of VOCs was not exceed the criteria exposure level 1 of working environment measuring method which announced by labor ministry in all ten nail shop indoor air quality. Conclusions: In this study although it was not significant correlation between harmful substances and medical check-up items in the nail shop indoor air quality, it is necessary to do more ventilation and to install exhaust facilities because of existing high VOCs concentration in the nail shop indoor air.

A Study on Indoor Environment of Interior with Ventilation

  • Kang, Tae-Wook;Koh, Jae-Yoon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.267-274
    • /
    • 2006
  • There are no solar loads through windows and heat transfer from outer walls of the building to the interior This study analyzes indoor air temperature and air flow distribution for the interior of buildings or vessels occupying space. Numerical method is adopted to visualize the indoor side environmental situation. that is without heat transmission to outside the building in various cooling load conditions; supply ventilation lighting. occupancy and infiltration in conditioned spaces. Reaching time of an air conditioner is predicted theoretically by cooling load variations. Theoretical modelling of the reaching time shows good agreement with experimental results.