• 제목/요약/키워드: inaccuracy

검색결과 452건 처리시간 0.026초

A Case-Based New Financial Product Screening System

  • Lee, Hoon-Young
    • 한국경영과학회지
    • /
    • 제19권3호
    • /
    • pp.151-167
    • /
    • 1994
  • Initial screening is one of the most important and difficult processes in new product development. Many new product screening models have been developed in management and marketing. However practical applications of these models have been limited in part due to their complexity and inflexibility, and in part due to their excessive data requirements. Thus simple judgment models have been popular in practice. However, these models suffer from inaccuracy and inconsistency originating form human cognitive limitations. In light of the problem swith traditional screening methods, we propose a new approach for screening based on managers' past experience and intuitive judgments-screening by analogy, and develop a computerized case-based system for screening new financial service concepts. Using the system, managers can predict the potential performance of a new product concept based on the performance of past products that are similar to it in terms of product characteristics, firm's resources, and market conditions. Based on this prediction, managers make a screening decision.

  • PDF

몬테카를로 시뮬레이션을 이용한 LCI data 불활실성 처리 방법론 (A Methodology on Treating Uncertainty of LCI Data using Monte Carlo Simulation)

  • 박지형;서광규
    • 한국정밀공학회지
    • /
    • 제21권12호
    • /
    • pp.109-118
    • /
    • 2004
  • Life cycle assessment (LCA) usually involves some uncertainty. These uncertainties are generally divided in two categories such lack of data and data inaccuracy in life cycle inventory (LCI). This paper explo.es a methodology on dealing with uncertainty due to lack of data in LCI. In order to treat uncertainty of LCI data, a model for data uncertainty is proposed. The model works with probabilistic curves as inputs and with Monte Carlo Simulation techniques to propagate uncertainty. The probabilistic curves were derived from the results of survey in expert network and Monte Carlo Simulation was performed using the derived probabilistic curves. The results of Monte Carlo Simulation were verified by statistical test. The proposed approach should serve as a guide to improve data quality and deal with uncertainty of LCI data in LCA projects.

플라스틱 유동해석 프로그램을 이용한 자동차 도어 핸들의 유동예측 (Plastic Flow Prediction of Automobile Door-Handle Using Injection Molding Simulation Programs)

  • 한성렬;강철민;유호종;정영득
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.295-298
    • /
    • 2004
  • Automobile door-handle is assembled with three parts that are base, skin and cover. Over-molding processing makes assembly of the base and skin. The skin part that was made by PVC polymer has various thickness. Plastic injection molding simulation of part including significant changed thickness as skin is an inaccuracy comparing with real injection molding. To solve this problem, two commercial flow prediction software that are Moldflow MPI and MAPS 3D were used in this study. Simulations were conducted for three types mesh. Taguchi method was applied for simulation experiments. It will be need to compare with simulation results and real over-molding behavior in the near future.

  • PDF

연속용융도금라인에서 에어나이프 특성이 도금편차에 미치는 영향 (A Study on Coating Deviation Effect by Air Knife Characteristics in CGL)

  • Bae, Y.H.;Ahn, D.S.;Lee, S.H.
    • 한국정밀공학회지
    • /
    • 제10권3호
    • /
    • pp.57-68
    • /
    • 1993
  • Air Wiping technique is widely used because of easy and efficient coating control in present CGL. Coaring weight is decided by nozzle header pressure, strip line speed and distance between strip and nozzle. Coating defects are results from unbalance of these factors and coating equipment calibration inaccuracy. Therefore, this study is mainly dealing with the cause of coating defects such as edge overcoating and coating deviation. The coptimum working condition is suggested by formulated coating model using collected working data. We developed two demension analysis program for air flow in nozzle and calculated dynamic pressure and air velocity with this program. The productivity and coating guality are improved by applying the result of this reserach.

  • PDF

강인한 SLAM을 이용한 무한궤도형 이동로봇의 모션 추정 (The Motion Estimation of Caterpilla-type Mobile Robot Using Robust SLAM)

  • 변성재;이석규;박주현
    • 전기학회논문지
    • /
    • 제58권4호
    • /
    • pp.817-823
    • /
    • 2009
  • This paper proposes a robust method for mapping of a caterpillar-type mobile robot which inherently has uncertainty in its modeling by compensating for the estimated pose error of the robot. In general, a caterpillar type robot is difficult to model, which results in inaccuracy in Simultaneous Localization And Mapping(SLAM). To enhance the robustness of the SLAM for a caterpillar-type mobile robot, we factorize the SLAM posterior, where we used particle filter to estimate the position of the robot and Extended Kalman Filter(EKF) to map the environment. The simulation results show the effectiveness and robustness of the proposed method for mapping.

초점 연산자의 최적화를 통한 세포영상의 삼차원 형상 복원 알고리즘 (Shape From Focus Algorithm with Optimization of Focus Measure for Cell Image)

  • 이익현;최태선
    • 한국정보전자통신기술학회논문지
    • /
    • 제3권3호
    • /
    • pp.8-13
    • /
    • 2010
  • Shape from focus (SFF) 방법은 이미지의 초점화된 영상을 이용하여 삼차원의 형상을 복원하는 방법이다. 그동안 많은 SFF 방법들이 연구되어 왔지만 노이즈에 대한 문제점과 영상특성으로 인한 최적화되지 못한 문제점이 남아있었다. 그러므로 노이즈를 제거하기 위한 필터링과 최적화 알고리즘을 제안한다. 성능 평가를 위하여 통계적인 판별기준인 평균제곱근오차 (RMSE)와 상관관계 (correlation) 수치를 이용한다.

  • PDF

Heart Rate Estimation Based on PPG signal and Histogram Filter for Mobile Healthcare

  • Lee, Ju-Won;Lee, Byeong-Ro
    • Journal of information and communication convergence engineering
    • /
    • 제8권1호
    • /
    • pp.112-115
    • /
    • 2010
  • The heart rate is the most important vital sign in diagnosing heart status. The simple method to measure the heart rate in the mobile healthcare device is using the PPG signal. In developing the mobile healthcare device using the PPG signal, the most important issue is the inaccuracy of the measured heart rate because the PPG signal is distorted from the user's motions. To improve the problem, this study proposed the new method that is to estimate the heart rate without an additional sensor in real life. The proposed method in this study is using the histogram filter. In order to evaluate the performance of the proposed method, the study compares its results with the moving average method in motion environment. According to the experimental results, the performance of the proposed method was more than 40% better than the performances of the MAF.

공정능력의 평가를 위한 개선된 비공정능력지수 (An Improved Process Incapability Index for the Evaluation of Process Capability)

  • 신경석;김성집;강창욱
    • 품질경영학회지
    • /
    • 제24권4호
    • /
    • pp.90-102
    • /
    • 1996
  • Process incapability index which is intended to evaluate the process capability by measuring process incapability provides more detailed information by dividing information about the process mean and variance. But when the target value is not consistent with the center of specification, it is very difficult to evaluate the process capability accurately. Thus it is necessary to improve the existing process incapability index. The improved process incapability index can identify the variation of the process faster than other process capability indices when applied firstly, to the precision process which can be affected sensitively by the change of the process, secondly, to the ordinary process where cost difference from the change of process is noticeable. By using subindices such as inaccuracy index and imprecision index, it is easier for quality manager to find where the cause of the variation of process is, and to take necessary action in advance.

  • PDF

최적설계를 위한 반응표면의 생성에 관한 연구 (A Study on the Construction of Response Surfaces for Design Optimization)

  • 홍경진;전광기;조영석;최동훈;이세정
    • 대한기계학회논문집A
    • /
    • 제24권6호
    • /
    • pp.1408-1418
    • /
    • 2000
  • Gradient-based optimization methods are inefficient in applications which require expensive function evaluations, and useless in applications where objective and/or constraint functions are 'noisy' due to modeling and cumulative numerical inaccuracy since gradient evaluation results cannot be reliable. Moreover, it is difficult to be integrated with commercial analysis software, and they cannot be employed when only experimental analysis results are available. In this research an optimization program based on a response surface method has been developed to overcome the aforementioned difficulties. Various methods for design of experiments and new proposed approximation models are implemented in the program. The effectiveness of the optimization program is tested on several test problems and results are discussed.

Improvement and Verification of the Wear Volume Calculation

  • 김형규;이용호
    • KSTLE International Journal
    • /
    • 제6권1호
    • /
    • pp.21-27
    • /
    • 2005
  • A technique for a wear volume calculation is improved and verified in this research. The wear profile data measured by a surface roughness tester is used. The present technique uses a data flattening, the FFT and the windowing procedure, which is used for a general signal processing. The measured value of an average roughness of an unworn surfnce is used for the baseline of the integration for the volume calculation. The improvements from the previous technique are the procedures of the data flattening and the determination of a baseline. It is found that the flattening procedure efnciently manipulates the raw data when the levels of it are not horizontal, which enables us to calculate the volume reasonably well and readily. By comparing it with the weight loss method by using artificial dents, the present method reveals more volume by aroung 3~10%. It is attributed to the protruded region of the specimen and the inaccuracy and data averaging during the weght loss measurement. From a thorough investigation, it is concluded that the present technique can provide an accurate wear volume.