• Title/Summary/Keyword: in-circuit test

Search Result 1,629, Processing Time 0.028 seconds

Basic bifurcation by intermittently coupled capacitors

  • Shimakawa, Junya;Saito, Toshimichi
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1614-1617
    • /
    • 2002
  • This paper studies basic phenomena of intermittently coupled capacitors circuits. As an analysis tool, we introduce Hybrid return map of real and binary variables, and analyze bifurcation phenomena for three parameters . Co-existence of synchronous phenomena is also shown. Using a simple test circuit, typical phenomena see verified in the laboratory.

  • PDF

Phase control of interleaved converters based on WTA

  • Tazaki, Shintaro;Saito, Toshimichi
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1386-1389
    • /
    • 2002
  • We consider interleaved buck converters using a switching rule based on Winner-Take-All (ab. WTA) nonlinearity. We clarify that this system exhibits various bifurcation phenomena. We also show that the switching phase of each converter is controlled by the WTA. Using a simple test circuit, ripple reduction and typical phenomena are verified in the laboratory.

  • PDF

A four-dimensional chaotic spiking oscillator

  • Takahashi, Yusuke;Nakano, Hidehiro;Saito, Toshimichi
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1992-1995
    • /
    • 2002
  • This paper presents a novel 4-D chaotic spiking oscillator. The oscillator can generate hyperchaos characterized by two positive Lyapunov exponents. Us-ing a simple test circuit, typical phenomena can be verified in the laboratory.

  • PDF

Calculation of Transformer Exciting Current by Finite Element Method (유한요소법을 이용한 변압기 여자전류 계산)

  • Kim, Ji-Hyun;Kim, Young-Man
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.52-54
    • /
    • 2005
  • This paper describes an exciting current calculation method for transformers by finite element method. In case of a special case such as air-gap presence, one can not calculate exciting current accurately using exciting power curves due to flinging effect, magnetic saturation and so on. Transient analysis with external circuit is performed with a 2D model and compared to a test result.

  • PDF

Design and Control of the Half-Bridge Type Switching Regulator (반브리지형 스위칭 전원의 설계 및 제어)

  • 고영길;이광원
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.2
    • /
    • pp.76-82
    • /
    • 1984
  • This paper presents the design and the optimal control method of current-fed half-brige switching regulator. To achieve fast response load current variation is fed to control input, and simple optimal control model has been derived with provision of current control loop in the control circuit. Test results show that the control system model is correct and 5ms response time has been obtained at 25 KHz switching frequency.

  • PDF

A New Synthetic Test Circuit for Testing Thyristor Valve in HVDC Converter (HVDC 컨버터의 Thyristor Valve 시험을 위한 새로운 합성시험회로)

  • Kim, Kyeong-Tae;Lee, Yoon-Seok;Han, Byung-Moon
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.236-237
    • /
    • 2012
  • 본 연구에서는 Thyristor로 구성되는 HVDC System의 Thyristor밸브를 시험하기위한 새로운 합성시험회로를 제안하고 그 성능과 동작을 분석한 내용에 대해 기술하고 있다. 제안하는 시스템의 동작 타당성을 체계적으로 분석하기 위해 PSCAD/EMTDC 소프트웨어를 이용한 시뮬레이션 모델을 개발하였으며 이를 기반으로 하드웨어 시스템을 제작하여 제안하는 시스템의 동작특성을 분석하였다.

  • PDF

An Analysis of the Frequency-Dependent Resultant Ground Impedance of Vertical Ground Electrodes Installed in Parallel (병렬로 시공된 수직 접지전극의 합성접지임피던스의 주파수의존성 분석)

  • Lee, Bok-Hee;Cho, Sung-Chul;Seong, Chang-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.2
    • /
    • pp.99-105
    • /
    • 2012
  • This paper deals with the experimental results of the frequency-dependent resultant ground impedance of vertical ground electrodes installed with a regular n-polygon. In order to propose an effective method of installing the vertically-driven multiple ground electrodes used to obtain the low ground impedance, the resultant ground impedance of ground electrodes installed with a regular n-polygon were measured as functions of the number of ground electrodes and the frequency of test currents and the results were discussed based on the potential interferences among ground electrodes. As a consequence, the effect of potential interference on the resultant ground impedance of vertical ground electrodes is frequency-dependent and it is significant in the low frequency of a few hundreds [Hz]. The resultant ground impedance of multiple vertical ground electrodes is not decreased in linearly proportion to the number of ground electrodes due to the overlapped potential interferences. Also the distributed-parameter circuit model considering the potential interference, the frequency-dependent relative permittivity and resistivity of soil was proposed. The simulated results of the frequency-dependent resultant ground impedance of multiple vertical ground electrodes are in good agreement with the measured data.

Fabrication and effect of different temperatures on the supported thin Anode for molten carbonate fuel cell (용융탄산염 연료전지에서 지지체를 사용한 얇은 연료극의 제작과 각기 다른 온도에서의 영향)

  • Park, Dongnyeok;Giulio, Nicola Di;Seo, Dongho;Yoon, Sungpil;Shul, Yonggun;Han, Jonghee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.82.1-82.1
    • /
    • 2010
  • Recently, Molten carbonate fuel cells(MCFCs) have been developing to get a good durability and economic feasibility for commercialization. To achieve these objectives, the cost of nickel based electrodes should be reduced. Regular anode thickness used in MCFCs is normally 0.7mm. Thus, in our study, the purpose was to reduce anode thickness up to 0.3 mm keeping MCFC performance on standard levels. In-situ sintering has been used, with 2 different fabrication methods (method A and B) and 2 different supports (support 1 and 2). Voltage losses at different temperature (600,620,640,$650^{\circ}C$) and after 1000 hours showed the higher performance that can be obtained using method B and support 2. After single cell test, an open-circuit voltage(OCV) of 1.075 V and a closed-circuit voltage(CCV) of 0.829V were obtained, at current density of $150mV/cm^2$. Also the voltage loss ratio at different cell temperature was lower in the case of method B and support 2. According to these results, the cost of anode fabrication can be reduced in the future, contributing for the economical feasibility of MCFCs.

  • PDF

Pattern recognition using AC treatment for semiconductor gas sensor array

  • Nguyen, Viet-Dung;Joo, Byung-Su;Huh, Jeung-Su;Lee, Duk-Dong
    • Proceedings of the IEEK Conference
    • /
    • 2003.07d
    • /
    • pp.1549-1552
    • /
    • 2003
  • Semiconductor gas sensor using tin oxide as sensing material has been used to detect gases based on the fact that impedance of the sensing material varies when the gas sensor is exposed to the gases. This variation comprises of two parts. The first one is variation in resistance of the sensing material and the other is expressed in terms of the sensor capacitance variation. Normally, only variation of the sensor resistance is considered. In this paper, using AC measurement with a capacitor-coupled inverting amplifier circuit, both changes in the sensor resistance and variations in the sensor capacitance were investigated. These characteristics were represented as magnitude gain and phase shift of AC signal at a specific frequency after passing it through the sensor and the designed circuit. A two-stage artificial neural network, which utilized the information above, was employed to identify and quantify three combustible gases: methane, propane and butane. The network outputs were approximately proportional to concentrations of test gases with reasonable level of error.

  • PDF

The Effect of Temperature on Corrosion of Absorption Refrigeration Systems Using LiBr-$H_2O$ Working Fluids (LiBr-$H_2O$계 흡수식냉동기의 부식에 미치는 온도의 영향)

  • 임우조;정기철;윤병두;강성수
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.92-97
    • /
    • 2001
  • This paper was studied on the effect of temperature on corrosion of absorption refrigeration systems using LiBr-$H_2O$ working fluids. In the fresh water and 62 %lithium bromide solution at $70^{\circ}C$, polarization test of SS 400, Cu(Cl220T-OL) and Ni-Al bronze was carried out. And Polarization behavior, polarization resistance characteristics, corrosion rate(mmpy) and corrosion sensitivity of materials forming absorption refrigeration systems was considered. The main results are as following: As the experimental temperature increase, the change of corrosion rate of Ni-Al bronze become duller than SS 400 and Cu in 62 % lithium bromide solution. Open circuit potential of SS 400 is less noble than that of Cu and Ni-Al bronze in fresh water, but that becomes noble than Cu and Ni-Al bronze in 62 % lithium bromide solution. The corrosion sensitivity of Ni-Al bronze was controlled than that of Cu and SS 400 in 62% LiBr solution.

  • PDF